Wincor Nixdorf PSA /go Rack Operating instructions

Type
Operating instructions
PSA /go Rack
User Manual
We would like to know
your opinion on this publication.
Please send us a copy of this page
if you have any constructive criticism on:
- the contents
- the layout
- the product
We would like to thank you in advance
for your comments.
With kind regards,
Wincor Nixdorf International GmbH
Documentation, RD HWD 01
Rohrdamm 7
D-13629 Berlin
Email: retail.documentation@wincor-nixdorf.com
_____________________________________________________________________________
Your Opinion:
PSA /go Rack (Order No: 01750198428A)
Published by:
Wincor Nixdorf International GmbH
D-33094 Paderborn
Order No.: 01750198428A
PSA /go
Rack
Edition July 2010
User Manual
All product names mentioned in this document are registered trademarks of the
respective owners.
All rights reserved, particularly (in whole or in part) those of translation, reprint,
reproduction by copying or similar means. We reserve the right to seek damages for all
infringements. All rights, including rights created by patent grant or registration of a
utility model or design, are reserved. We reserve the right to determine delivery
options or make technical modifications.
Copyright © Wincor Nixdorf International GmbH, 2010
Contents
Manufactures Certification 1
Warranty 1
Safety Instructions 2
Overview 3
Rack Versions 4
Scope of Delivery 5
Mounting Guide 6
Prerequisites 6
Procedure 9
Exchanging the Station Module 11
Fuse Exchange 13
Maintenance and Support 14
PSA /go Rack
_____________________________________________________________________
1
Manufacturer´s Certification
The device complies with the requirements of the directive 2004/108/EC
with regard toElectromagnetic compatibility" and 2006/95/EC “Low
Voltage Directive”.
Therefore, you will find the CE mark on the device or packaging.
Warranty
Wincor Nixdorf generally guarantees a limited warranty engagement for
12 months beginning with the date of delivery. This warranty egagement
covers all those damages which occur despite a normal use of the
product.
Damages because of
- Improper or insufficient maintenance,
- Improper use of the product or unauthorized modifications of the
product,
- Inadequate location or surroundings
will not be covered by the warranty.
All parts of the product which are subject to wear and tear are not
included in the warranty engagement.
PSA /go Rack
_____________________________________________________________________
2
Safety Instructions
Please read the information in this manual carefully before you start
running your PSA /go series product.
Included in delivery is the booklet Important Notes/Safety
Information. Observe the instructions and information given therein!
For a quick consultation keep this manual safe and ready to
hand.
PSA /go Rack
_____________________________________________________________________
3
Overview
PSA /go Rack
_____________________________________________________________________
4
Rack Versions
PSA /go Rack 28
Dimensions: W 940, H 750, D 80 mm
Weight: 20 Kg
PSA /go Rack 49
Dimensions: W 940, H 1140, D 80 mm
Weight: 30 Kg
PSA /go Rack 70
Dimensions: W 940, H 1540, D 80 mm
Weight: 40 Kg
PSA /go Rack
_____________________________________________________________________
5
Scope of Delivery
- 1 Power cable, length 2.5 m
- Wall mount, 4 screws, 6x70 DIN18182
- Wall mount, 4 wall plugs, type s10
- Panel mount, 4 screws, M6x70, DIN965
- Panel mount, 8 hexagon nuts, M6, DIN 9021
- Panel mount, 8 plain washers, M6, DIN9021
- 1 Install jig for wall and panel mount
PSA /go Rack
_____________________________________________________________________
6
Mounting Guide
Prerequisites
Mounting tools not included in the package.
You need:
- for wall mount
Masonry bit 10 mm
Screwdriver-Phillips Bit #3
- for panel mount
Metal drill bit 7 mm
Screwdriver-Phillips Bit #3
- Wrench # 10
PSA /go Rack
_____________________________________________________________________
7
Minimal distance of PSA /go rack from the objects and floor
floor
PSA /go Rack
_____________________________________________________________________
8
Spacing of mounting holes
S = PSA /go Rack 28
M = PSA /go Rack 49
L = PSA /go Rack 70
PSA /go Rack
_____________________________________________________________________
9
Procedure
Wall mount - drill the hole (Ø 10 mm) and insert wall plug. Use install jig
to adjust position of the screw.
Panel mount - drill the hole7 mm). Use install jig to adjust position of
the screw.
Plug in main power cable into the PSA /go rack.
PSA /go Rack
_____________________________________________________________________
10
Hang the PSA /go rack onto screws.
1. Plug the power cable into wall outlet.
2. Switch on main switch through opening at the PSA /go rack
PSA /go Rack
_____________________________________________________________________
11
Exchanging the Station Module
Wrench off cover (with slotted screwdriver).
Remove the cover.
Open the lock with a Hex L-Key #8.
PSA /go Rack
_____________________________________________________________________
12
Remove the station module.
Insert a new station module
Plug in the cover
PSA /go Rack
_____________________________________________________________________
13
Fuse Exchange
Fuses may only be replaced with identical types or other types
recommended by the manufacturer.
Fuse: T10AL250V
Procedure
1. Switch off Main Switch
2. Unplug the power cable
from the wall
3. Unplug the power
- Remove fuse
- Insert new fuse
PSA /go Rack
_____________________________________________________________________
14
Maintenance and Support
1. Switch off the unit before cleaning
2. Remove the dust from aluminium and plastic surfaces with a non-
electrostatic dust cleaner
3. Remove the dust from contacts in station module with antistatic brush
4. Do not use any abrasive material.
5. Switch on the unit only when it is completely dry.
6. Recommended interval of contacts cleaning: 1 week
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21

Wincor Nixdorf PSA /go Rack Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI