  • Hello! I am an AI chatbot trained to assist you with the Promax Digital To TV (DTTV) User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
MANUAL DE CONTROL WEB
WEB CONTROL MANUAL
MANUEL DU CONTRÔLE WEB
DIGITAL To TV
- 0 MI2013 -
MANUAL DE CONTROL WEB
MANUAL DE CONTROL WEB
Página 2 Julio 2016
WEB CONTROL MANUAL
USER'S MANUAL VERSION
Version Date Software Version
2.0 July 2016 2.24
WEB CONTROL MANUAL
TABLE OF CONTENTS
1 Introduction................................................................................................................ 1
2 Installation Instructions .............................................................................................. 3
2.1 Installation
Requirements.................................................................................... 3
2.1.1
System Requirements................................................................................... 3
2.1.2
Software Requirements ................................................................................3
2.1.3
Communication Requirements...................................................................... 3
2.2 Installation
...........................................................................................................4
3 Oper
ation................................................................................................................... 6
3.1 Starting
................................................................................................................ 6
3.2 Menu
Options ...................................................................................................... 7
3.3 Equipment
VIEW ............................................................................................... 10
3.3.1
Module Detail ..............................................................................................12
3.4 Conflicts
.............................................................................................................15
3.5
DVB-S/S2 Reception View................................................................................ 15
3.6 DVB-T
Reception View...................................................................................... 16
3.7
IP TV Reception ................................................................................................ 17
3.8
IP TV Transmission........................................................................................... 18
3.9 DVB-T
Transmission View ................................................................................ 19
3.10
Services View....................................................................................................21
3.11
LCNs View......................................................................................................... 22
3.12
Transport Stream IDs ........................................................................................ 23
3.13
Conditional Access View................................................................................... 24
3.14
Read file ............................................................................................................ 25
3.15
Saving XML file ................................................................................................. 26
3.16
Logout ...............................................................................................................26
4 Troublesh
ooting....................................................................................................... 27
WEB CONTROL MANUAL
WEB CONTROL MANUAL
July 2016 Page 1
WEB CONTROL MANUAL
1 Introduction
This WEB application provides access to the “Digital to TV” headend (short
DTTV) from a computer, via Ethernet. This way you can configure and control remotely
all the modules that make up the headend.
This web application to control DTTV, should be installed on a Web server on the
PC client. Once it is installed, the headend can be set using a compatible web browser.
You must install the JAVA software.
The remote control allows you to work on the headend from a computer in a more
comfortable way, whether to check the status of signal output, to change the selected
services or for general maintenance. Although some of the parameters are configurable
only from the headend itself, as the IP address or the password.
You can download the latest version of the program from PROMAX website.
WEB CONTROL MANUAL
Page 2 July 2016
WEB CONTROL MANUAL
July 2016 Page 3
2 Installation Instructions
2.1 Installation Requirements
2.1.1 System Requirements
- Pentium compatible or higher.
- 10 MB of available hard disk space.
- 1 CD-ROM Unit.
- 1 Ethernet Port.
2.1.2 Software Requirements
- The application has been validated on the following systems:
- Windows XP 32 bits.
- Windows 8 64 bits.
- Windows 8 32 bits.
- Windows 7 32 bits.
- Windows 7 64 bits.
- Windows Vista 32 / 64 bits (in this case the JRE7 is not automatically
installed and should be downloaded from the web).
- Web browser (Internet Explorer 8 or higher; Firefox 3 or higher).
- Java SE Runtime Environment 1.7 (also called JRE7). If not the program will
install JR7 Update 40. You can download the last version from
http://www.java.com.
2.1.3 Communication Requirements
- Configure IP Headend (See Manual to configure DT-80x headend).
- Connection between client computer and headend through ports TCP 80 and
10001.
WEB CONTROL MANUAL
Page 4 July 2016
2.2 Installation
The DTTV Control software installation is supplied on a memory drive (flash drive
or CD-ROM) or can be downloaded from the page "Firmware and Software" from the
"Downloads" area at the PROMAX web page (www.promaxelectronics.com).
Locate the file (DttvControl-va.b.ccc.exe) and proceed to the installation by
following next steps:
1. Run the file by double clicking on it.
2. Follow the installation wizard that will guide you during the process.
Figure 1.-
3. During installation the program checks if the JAVA software is installed and
the version available. If the configuration is correct you should press any key
to continue the process. In case the configuration is not correct, then the
program installed or updates automatically the JAVA software on your
computer (for the case of Windows Vista 32-bits and 64-bits, the JRE7 is not
automatically installed and the system will pop up a window with the option to
download and install from the JAVA web).
WEB CONTROL MANUAL
July 2016 Page 5
Figure 2.-
4. After installation the program creates a shortcut icon on the desktop and in
"Start \ All Programs \ PROMAX \ DTTV Control va.b.ccc \". At this address
you can find also access to the uninstall icon (Unistall) and to the reconfigure
icon (Reconfigure).
For Windows 8 the "Start \ Programs" menu is on the "Search" option from
the menu that appears when you bring the mouse to the upper right corner of
the screen. Here you should select "Applications".
NOTE:
If you uninstall the JAVA after installing the program it will appear a JAVA searching
screen. The program should be uninstalled and reinstalled.
When running the program appears a window with the message “Reconfigure if
application does not work”, you should reconfigure the application by using the
"Reconfigure (admin only)". The problem may be due to an automatic update of
JAVA. In any case, if the program gives an operation problem, you should use this
option to reconfigure the system.
In the case of Windows 8 32-bit is necessary to restart the PC after finishing the
installation.
WEB CONTROL MANUAL
Page 6 July 2016
3 Operation
3.1 Starting
1. Double-click on the icon DTTV Control at your desktop or go to the shortcut
icon in "Start \ All Programs \ PROMAX \ DTTV va.b.ccc Control \".
2. The starting window is:
Figure 3. — Starting Window.
At the upper part shows the control application version.
Below this you can select the program language by clicking on the
corresponding flag.
Then a box appears where you must enter the IP address to access the
headend.
Below there is a box where you should enter the access code or password.
The password is defined in local mode directly via headend (see your
manual DT-8xx).
3. After entering your password, click on the Login button. You will access the
control application.
WEB CONTROL MANUAL
July 2016 Page 7
4. When starting, the browser may display a window in which it requests
permission to run the program (Figure 4.-). Click on Accept. If you do not
want that window to reappear each time you run the program, tick the
checkbox. Security alerts should be respond positively in order to allow to run
the program without restriction.
Figure 4.-
3.2 Menu Options
The menu bar appears at the top of the screen (Figure 5.-) with all the available
options. This menu bar stays in all the screens, so it is always possible to access it very
quickly.
Figure 5.- Menu bar.
WEB CONTROL MANUAL
Page 8 July 2016
The equipment view affect the whole headend and individual modules.
The view options affect the modules with a specific functionality.
The equipment view are:
Equipment: It is a graphical representation of the set of modules that
make up the headend. It allows you to configure each one of
the modules.
Conflicts: It shows conflicts on the modules configuration.
Read File: It reads a XML file with data about the headend.
Save File: It records the present data from the headend in a XML file.
Logout: It exits the program.
The view options are:
DVB-S/S2
Reception: It shows common characteristics to all the receiving modules
of the satellite.
DVB-T
Reception: It shows common characteristics to all the terrestrial receiving
modules.
DVB-T
Transmission: It shows common characteristics to all the terrestrial
transmitting modules.
IP TV
Reception: It shows common characteristics to all the IP receiving
modules.
IP TV
Transmission: It shows common characteristics to all the IP transmitting
modules.
Services: It shows all detected services and it allows them to be
selected.
LCNs: It shows the channel numbers assigned to the first services.
IDs Transport
Stream: It shows the input identifiers and allows you to edit them at
the output.
Conditional Access
View: It shows all modules that support a CAM card.
WEB CONTROL MANUAL
July 2016 Page 9
The following sections describe in detail each one of the screens.
At the top right of the menu bar there is the status field. This field reports on what
the program is doing at each time.
The possible status are the following ones:
Refreshing fields Takes place when the program is updating the screen with
data from the headend.
Reading fields Takes place when accessing for the first time to a module and
its data is shown on screen.
Writing fields Takes place when the configuration of a module changes and
the new data is sent to the volatile memory of the headend.
Undoing fields Takes place when undoing actions done previously.
Storing
Configuration When it is stored on the non-volatile memory of the headend.
Sometimes it can appear on the menu a symbol of a red floppy-disk (see Fig. 5.-).
This signal indicates that some information has been sent to the head-end and it is in
the volatile memory of the head-end, so if you turn it off, that information sent will be
lost. In addition to this symbol, the program will notify by a message on screen, if you
exit the program without saving the information on the head-end.
ATTENTION: When the program is reading or undoing fields, buttons do not
respond.
In order to edit a value you have to click in a textbox or to choose from the
available options by displaying the menu. The background colour of the textbox
indicates the update status of data, according to the following:
White: The data shown on screen matches de data in the headend.
Orange: The data has been validated and accepted by the program
but it has not been sent to the headend and therefore it does
not match with the headend data.
Gray: The data is only to read and cannot be edited.
Red: The data is in conflict with other data. Only for the View
Options.
WEB CONTROL MANUAL
Page 10 July 2016
3.3 Equipment VIEW
This screen shows a graphical representation of the headend configuration.
Figure 6.-
At the top, the text box shows the Kbps bitrate at the output.
Below this it appears a percentage referred to the busy bandwidth of the output
channel. This percentage it is accompanied by a colour that indicates the state of the
signal. Green when the signal is correct, yellow when it is possible that a peak of the
input signal saturates the channel or red if the signal is too big or small.
A red point above a module indicates that exists an error in the process, and
therefore some of the LEDs of warning at the module are ON.
The signal status is at the top of the module (terrestrial or satellite). The icons that
identify each state are:
Locked.
Not locked.
Unknown state.
Process failure.
In the case of a IP module:
: Ethernet network disconnected.
WEB CONTROL MANUAL
July 2016 Page 11
Acquiring services.
The CAM card state is displayed above the module. The icons that identify each
state are:
: Card connected and working.
: Card inserted but not working properly.
No icon: Card not detected.
For satellite receiving modules:
: LNB shortcut.
In the central part of the screen is displayed the configuration of the headend.
Each slot is occupied by a module. An Slot is defined as a physical hole where you can
place a module. A module can be single or double type. A double module has two
independent modules, module 1 and module 2. Both modules are identical and have
the same features although they are set independently. Double modules are
represented on screen as a module divided by a vertical line at the top. The left part
shows the state of the module 1 and the right part the state of the module 2.
When a module is not recognised or there is a hole between two modules, it is
represented by a module marked with a red cross as show in the figure
.
If you place the cursor on a module and wait for a while, then it appears a tag with
the firmware version of the module.
If it appears a module with orange background colour it means that module data
at the program do not match with module data at the headend.
If you can not complete the operation to load or save the configuration
(Figure 7.-), you should do it again and if the problem persists, you should check the
head-end configuration and the content of the xml file (if the problem is when loading)
or permissions (if the problem is when saving).
Figura 7.-
WEB CONTROL MANUAL
Page 12 July 2016
When there is an internal failure in the module, it appears a message like the
following figure. To see failure details click on the word "Details".
Figure 8.-
You can access the configuration of the module by clicking on it. Once inside you
can change its parameters (see "Module Details"). If you have any doubt about a
parameter, consult the specific manual of the module.
At the bottom of the headend graphical representation appears the links between
module, receivers and transmitters.
At the bottom there are 4 buttons for the following functions:
Undo All: It undoes all the changes not send to the headend.
Update PC: It consults the fields data from the headend and refreshes them
on screen. If there is some change without accepting, the data
disappears when superposing data from the headend.
Reconfigure
equipment: It sends the changes to the volatile memory of the headend. After
the reconfiguration, all modules should be with a white
background. If any module has an orange background, it means
that some errors have occurred, usually happens when the
module unlocks.
Store equipment
configuration: It saves the data in the non-volatile memory of the headend.
3.3.1 Module Detail
To access the details of a module that appears in the equipment view just click on
it. Next there is a detailed window of the module that is divided into two areas: a header
and field editing area.
WEB CONTROL MANUAL
July 2016 Page 13
Figure 9.- Example of a module detail for DT-324.
The header shows the module identification name (DT-324). Then a drop-down
menu allows you to select the module (if double, you have two modules, if simple only
one). Next to it, there are two buttons, which are common to all modules. These are:
- Update PC:
It updates the fields that the user has NOT modified with the headend
value.
- Reconfigure module:
It saves the changes on the volatile memory of the headend.
Next to these two buttons are others depending on the module you are. These
buttons provide access to editable fields related to the parameters of the module. These
are:
Transmission fields: For transmodulators modules/slots and audio/video
encoders.
Reception fields: For transmodulators modules/slots and modules / slots with
services balancing functionalities connected to two
modulators.
WEB CONTROL MANUAL
Page 14 July 2016
Balancing fields
and LCNs: For modules/slots with services balancing functionalities
connected to two modulators.
Services fields: For encoders modules/slots video / audio and IP TV
slots/modules.
IPTV fields: For IP TV modules/slots.
FEC fields: For modules/slots IP TV.
They only work with the RTP protocol. The LFEC x DFEC
value must be equal or less than 100.
Streams fields: For modules/slots IP TV.
TS and transmission
fields: For encoders modules/slots video/audio
Encoder and services
fields: For encoders modules/slots video / audio.
LCNs: For the case of receiver modules. You can edit the LCNs
for services received by the module (see figure below).
operation is the same as LCNs general view, but only
shows module services.
Figure 10.- Example of a module detail for DT-212.
/