RDLED4 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
CEILING CUT OUT MUST BE FREE OF ANY DEBRIS AND BURRS.
FIXTURE MOUNTING
This xture can be installed with ceiling temperature not
exceeding of 40°C and with minimum plenum height of 5/”.
The xture can be used to replace an existing unit or for new
construction with non-accessible ceiling in place.
1. Prepare the mounting surface with cut out diameter 5”
for RDLED4R and 5”x5” for RDLED4S. Cut-out must be
accurate not undersized.
2. Remove the dust protector.
3. Loosen the Junction Box Screw and open the Junction
Box (Fig.1). Attach Supply Wires into Junction Box and
connect to the xture. See wiring section for details.
4. Push up and slide the Junction Box section into the
ceiling. Be sure the Mounting Flag is folded in as the
xture slides through ceiling hole. (Fig. 3)
5. For the Wallwash Model, orient the xture such that the
Reector is in correct orientation. Wall Wash xtures are
provided with swivel arm for maximum adjustability in all
construction situations. Look for Towards the Wall’ label
on the xture. (Fig. 2)
6. To secure xture into ceiling, swing Mounting Flag
outward by turning Flag Screw clockwise. Ceiling
Flange should be snug tight against ceiling. DO NOT
OVERTIGHTEN SCREWS.
7. Insert dust protector to protect the LED & Reector until
Trim Assembly is ready to be installed.
RDLED4R RDLED4S
Cut-Out Diameter: 5” Cut-Out: 5”x5”
Supply wires
Fig: 1
Junction Box
Screw
Junction Box
Fig: 2
Mounting Flag
Flag Screw
Heat Sink
Ceiling Flange
Reector
Fig: 3
Flag Screws
RDLED4 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TROUBLESHOOTING
1. Check that the line voltage at the xture is correct. Refer
to wiring directions.
2. Is the xture grounded properly?
3. For questions on compatibility of dimmers purchased
separately or existing dimmers, refer to
www.rabweb.com
4. If the LED is blinking the xture may be overheating.
Remove the Trim assembly and if the xture is labeled
‘BLINKING LIGHT OF THIS THERMALLY PROTECTED
LUMINAIRE MAY INDICATE OVERHEATING’ allow the
xture to cool down. Determine cause of overheating
and remove. Fixtures with this label have a thermal
protector that turns xture o above a certain
temperature. It will automatically restart when cool.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
1. Do not open xture to clean the LED. Do not touch
the LED.
2. Do not touch reector, lens or trim cone.
3. Do not clean any xture surface with wood base cleaning
material such as paper towels or tissues. Only use micro
ber cleaning cloth.
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2014 RAB LIGHTING Inc.
No
rthvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
RDLED4 IN-1214
Trim clip
opening
Trim Assembly
Trim Clip
TRIM ASSEMBLY MOUNTING
1. Check to ensure the Trim clip opening is free of debris
and paint.
2. Match the Trim Spring Clip to Spring Clip Opening and
snap the Trim Assembly into Trim clip opening. Trim
ring should be ush to ceiling as shown in Fig. 4.
3. For the Wallwash Model, aim the xture such that the
reector is in correct orientation. Look for Towards the
Wall label on the reector.
Fig: 4
WIRING
RISK OF FIRE. Universal voltage driver permits operation at
120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic
Low Voltage (ELV) and Triac Dimming follow the wiring
directions in Fig. 5.
1. Connect the GROUND wire from xture to supply ground.
2. Connect the black xture lead to the (+) LINE supply lead.
3. Connect the white xture lead to the (-) COMMON supply
lead.
Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire
Control (Fig. 6) or EcoSystem Digital Controls (Fig. 7).
Note: See www.lutron.com for complete instructions and functional
compatibility of Lutron drivers with Lutron or other control systems/
dimmers.
Fig: 5
Fig: 6
Fig: 7
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance. RAB cannot troubleshoot
Lutron systems and have provided only basic information. See
www.lutron.com for complete instructions and functional
compatibility of Lutron Drivers with Lutron or other Control systems/
dimmers.
RDLED4 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
Ø5.5”
4.6”
12.53”
4.0”
2.5”
4.65”
12.53”
4.0”
2.5”
5.51”
DIMENSIONAL DRAWING
RDLED4R
RDLED4S
RDLED6 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining xture. No user serviceable parts inside.
CEILING CUT OUT MUST BE FREE OF ANY DEBRIS AND BURRS.
FIXTURE MOUNTING
This xture can be installed with ceiling temperature not
exceeding of 40°C and with minimum ceiling height of 5/”.
The xture can be used to replace an existing unit or for new
construction with non-accessible ceiling in place.
1. Prepare the mounting surface with cut out diameter 7”
for RDLED6R and 7”x7” for RDLED6S. Cut-out must be
accurate not undersized.
2. Remove the dust protector.
3. Loosen the Junction Box Screw and open the Junction
Box (Fig.1). Attach Supply Wires into Junction Box and
connect to the xture. See wiring section for details.
4. Push up and slide the Junction Box section into the
ceiling. Be sure the Mounting Flag is folded in as the
xture slides through ceiling hole. (Fig. 3)
5. For the Wallwash Model, orient the xture such that the
Reector is in correct orientation. Wall Wash xtures are
provided with swivel arm for maximum adjustability in all
construction situations. Look for Towards the Wall’ label
on the xture. (Fig. 2)
6. To secure xture into ceiling, swing Mounting Flag
outward by turning Flag Screw clockwise. Ceiling
Flange should be snug tight against ceiling. DO NOT
OVERTIGHTEN SCREWS.
7. Insert dust protector to protect the LED & Reector until
Trim Assembly is ready to be installed.
Supply wires
Fig: 1
Junction Box
Screw
A
A
B B
C C
D D
4
1234
23
R
AB
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
DRAWN BY: SCALE SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
ECN #
REV DESCRIPTION DATE
Init.
1
TOLERANCES
.X
.02
.XX
.01
.XXX
.005
ANGLES
.5
SCALE 0.500
Reector
Fig: 3
Flag Screws
RDLED6R RDLED6S
Cut-Out Diameter: 7” Cut-Out: 7”x7”
Junction Box
A
A
B B
C C
D D
4
1234
23
R
AB
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
DRAWN BY: SCALE SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
ECN #
REV DESCRIPTION DATE
Init.
1
TOLERANCES
.X
.02
.XX
.01
.XXX
.005
ANGLES
.5
SCALE 0.500
Mounting Flag
Fig: 2
Flag Screw
Heat Sink
Ceiling Flange
RDLED6 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TROUBLESHOOTING
1. Check that the line voltage at the xture is correct. Refer
to wiring directions.
2. Is the xture grounded properly?
3. For questions on compatibility of dimmers purchased
separately or existing dimmers, refer to
www.rabweb.com
4. If the LED is blinking the xture may be overheating.
Remove the Trim assembly and if the xture is labeled
‘BLINKING LIGHT OF THIS THERMALLY PROTECTED
LUMINAIRE MAY INDICATE OVERHEATING’ allow the
xture to cool down. Determine cause of overheating
and remove. Fixtures with this label have a thermal
protector that turns xture o above a certain
temperature. It will automatically restart when cool.
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
1. Do not open xture to clean the LED. Do not touch the
LED.
2. Do not touch reector, lens or trim cone.
3. Do not clean any xture surface with wood base cleaning
material such as paper towels or tissues. Only use micro
ber cleaning cloth.
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2014 RAB LIGHTING Inc.
No
rthvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
RDLED6 IN-1214
A
A
B B
C C
D D
4
1234
23
R A B
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
DRAWN BY: SCALE SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
ECN #
REV DESCRIPTION DATE
Init.
1
TOLERANCES
.X
.02
.XX
.01
.XXX
.005
ANGLES
.5
SCALE 0.500
Spring Clip
Opening
Trim Ring
TRIM ASSEMBLY MOUNTING
1. Check to ensure the Trim clip opening is free of debris
and paint.
2. Match the Trim Spring Clips (3) to Sping Clip Openings.
Trim Ring should be ush to ceiling.
Note: For round xtures, Trim Spring Clip Opening Pattern is
not Symmetrical. Trim Ring must be orientated as in Fig. 4.
Install Trim Spring Clip marked with red dot on Trim Ring into
the Spring Clip Opening marked with red dot as in Fig. 4.
3. For the Wallwash Model, aim the xture such that the
reector is in correct orientation. Look for Towards the
Wall label on the reector.
A
A
B B
C C
D D
4
1234
23
R A B
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
DRAWN BY: SCALE SHEET:
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
ECN #
REV DESCRIPTION DATE
Init.
1
TOLERANCES
.X
.02
.XX
.01
.XXX
.005
ANGLES
.5
SCALE 0.500
Trim Spring Clip
Fig: 4
.
.
WIRING
RISK OF FIRE. Universal voltage driver permits operation at
120V thru 277V, 50 or 60 Hz. For Non-Dimming, Electronic
Low Voltage (ELV) and Triac Dimming follow the wiring
directions in Fig. 5.
1. Connect the GROUND wire from xture to supply ground.
2. Connect the black xture lead to the (+) LINE supply lead.
3. Connect the white xture lead to the (-) COMMON supply
lead.
Lutron L3D Hi-Lume series drivers work with Lutron 3-Wire
Control (Fig. 6) or EcoSystem Digital Controls (Fig. 7).
Note: See www.lutron.com for complete instructions and functional
compatibility of Lutron drivers with Lutron or other control systems/
dimmers.
Fig: 5
Fig: 6
Fig: 7
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance. RAB cannot troubleshoot
Lutron systems and have provided only basic information. See
www.lutron.com for complete instructions and functional
compatibility of Lutron Drivers with Lutron or other Control systems/
dimmers.
RDLED6 INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
14.53
[369,1]
4.97
[126,1]
7.52
[191,1]
2.49
[63,3]
DIMENSIONAL DRAWING
RDLED6R
RDLED6S
Ø7.52”
2.49”
4.97”
14.53”
7.52
[191,1]
7.52
[191,1]
2.49
[63,3]
14.35
[364,4]
4.68
[118,9]
7.52”
7.52”
2.49”
4.68”
14.35”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

RAB Lighting RDLED4R12D-50YYHC-M-W Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI