tekmar 2 Thermostat 528 , 528 Quick Set-up

  • Hello! I am an AI chatbot trained to assist you with the tekmar 2 Thermostat 528 Quick Set-up. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
© 2014 528_Q - 02/14
1
A Watts Water Technologies Company
1. Location
2. Remove Mounting Base
3. Install Mounting Base
Thermostat
Base
Adaptor
Plate 007
Switch
Box
OR
Thermostat
Base
Wall
Exterior
Wall
Behind
Door
Interior
Wall
5 feet
1.5 m
tekmarNet
®
2 Thermostat 528
Quick Setup Guide
528
_
Q
02/14
Zoning
Replaces: 12/13
© 2014 528_Q - 02/14
2
A Watts Water Technologies Company
4. Wiring
5. Switch Settings
12 34
tN2 Manager, Module
or Wiring Center
tN2 tN2
Slab Sensor 079, or
Outdoor Sensor 070, or
Indoor Sensor 076, 077, 084
1234
tNt 528
528
One Stage Heat
Mmm YYYY
Lot # 12345
Meets Class B:
Canadian ICES
FCC Part 15
1023-02
tN2
1
tN2
2
Switch Settings:
For instructions see brochure
Use at least 65°C conductors
ON
Sensor
34
Setback
Scene
Lock
Not used
Not used
Unlock
Off
Off
No Power
Switch Setting Location
Switch
Position
Action
1
ON
SETBACK Allow thermostat to respond to
available schedule. Requires Timer 033.
OFF OFF No setback schedule response.
2
ON
SCENE Allow thermostat to respond to
scenes. Requires User Switch 479.
OFF OFF No scene response.
3
ON
LOCK Locked to ‘User’ access level. Set to
Lock when installation completed.
OFF
UNLOCK Unlock to access all settings. Set
to Unlock during installation.
4
ON Not used
OFF Not used
© 2014 528_Q - 02/14
3
A Watts Water Technologies Company
6. Close Thermostat
pivot
tab
8. Critical Settings
The following settings are essential to the successful operation of the system.
Important
Note: Set switch setting #3 and tekmarNet
®
system control to Unlock to change
Access level to Installer. Return to Lock setting once installation has been completed.
Press and hold down both the and buttons for 2 seconds
to change from one step to the next.
Release both buttons once the step has been reached.
• Press the or the button to change the setting, if
available.
Press and hold down both the and buttons for 2
seconds to go to the next step, OR
After 10 seconds of no button activity, the display goes
back to normal operation.
Press
+
Together
7. User Interface
All specifications are subject
to change without notice
4 528_Q - 02/14.
Product design, software and literature are Copyright ©2014 by tekmar Control Systems Ltd.,
A Watts Water Technologies Company. Head Offi ce: 5100 Silver Star Road, Vernon, B.C.
Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650
Web Site
: www.tekmarControls.com
For a full list of settings and operational details, please refer to the thermostat
Installation and Operation Manual (528_D) included with compatible
tekmarNet
®
controls or download the brochure from www.tekmarcontrols.com
8. Critical Settings (Continued)
Display Range Access Description
°F or °C
Default =
°F
Installer
User
TEMPERATURE UNITS
Press the or the button to
change from °F to °C and vice versa.
Set To:
H1
H1
ADJUST
ADJUST
SUPPLY
OFF or
On
Default =
On
Installer
HEAT SUPPLY PUMP
During heating, select whether or not
the system supply pump should turn
on or be off to allow a zone group
pump per manifold.
Available when:
• A reset control is present on the
tekmarNet
®
system.
Set To:
H1
H1
ADJUST
ADJUST
SUPPLY
OFF or
On
Default =
OFF
Installer
HEAT SUPPLY PUMP DELAY
During heating, select whether or not
the system supply pump should be
delayed by 3 minutes before coming
on (for thermal motor or wax actuator).
Available when:
• A reset control is present on the
tekmarNet
®
system.
Set To:
On or Off
Default =
On
Installer
ROOM SENSOR
Select whether the built-in air
temperature sensor is on or off.
Available when:
A floor sensor or room sensor is
installed on the auxiliary sensor
input.
Set To:
Off,
Room,
Outdoor,
Floor,
Floor dSP
Installer
AUXILIARY SENSOR
Select the type of auxiliary sensor.
Floor dSP = Show floor sensor reading
in upper number field.
Available when:
Auxiliary sensor automatically
detected.
Set To:
© 2014 528_Q - 02/14
5
Une Entreprise de Watts Water Technologies
1. Emplacement
2. Retirez la base de montage
3. Installez la base de montage
Mur extérieur
Mur intérieur
5 pi.
1,5 m
Commutateur
boîte
OU
Base de
thermostat
Mur
Base de
thermostat
Plaque
adaptrice 007
tekmarNet
®
2 Thermostat 528
Guide d'installation rapide
528
_
Q
02/14
Zonage
Remplace: 12/13
Derrière
porte
/