MULTIPLEX Flojet G56 series CO2/Air Driven Beer Pump Installation guide

Type
Installation guide
FLOJET G56 SERIES
FLOJET’S NEW
AIR/GAS OPERATED
BEER PUMP
The Flojet Model G56 Series Pump
Designed for dispensing draft beer from keg, cask or brew
kettle through both long or short, vertical or horizontal line runs
while maintaining the brewers recommended applied pressure
on the beer. The gas pressure applied to the beer and the
air/gas pressure applied to the pump, to move the beer from the
vessel to the point of dispense, are completely separate
, thus
ensuring the repeatable quality of presentation and taste to the
customer.
The beer pump increases the
pressure in the product dispense
line, which ensures that the inher-
ent gas in the solution (beer) can-
not break out.
No beer
Smaller I.D. tubing can be used in
some installations, which reduces
the amount of beer wasted when
cleaning lines.
Pump can also be utilized to aid
in beer line cleaning through wall
mounted cleaning sockets.
Non-pressurized
cleaning bottle
CO
2
Tank
Air compressors can be used to
pressurize the beer pumps.
Cost effective; no need for mixed
gases or gas blenders.
Can dispense to multiple faucets
(up to 5 ) from a single keg or keg
series. This will cut walk-in cooler
clutter by lowering the number of
kegs on tap at one time which pro-
motes product quality/freshness.
Regulator valve controls the drive
pressure to the pump, which pro-
vides a basis by which the pump
can be infinitely variable to suit all
runs and rises that are likely to be
experienced with dispense lines.
should be pressured into changing.
Feeding up to three faucets
through a single line.
Capable of traversing up to 800
feet, horizontally through a single
line.
The required applied keg pres-
sure need not exceed the natural
internal keg pressure recommend-
ed by the brewer. This helps to
control over-carbonation, thus
maintaining quality.
Most importantly, the use of
the G56 pump ensures the
repeatable quality of presenta-
tion and taste to the customer.
G56 BEER PUMP
The air/gas used to power the
pump never comes in contact
with the beer, thus providing pro-
tection from flat or tainted beer
due to impure air contamination
or oxidation.
Capable of delivering beer up to
10 stories, vertically through a
single line.
F100-260 REV 5/02-5M
www.flojet.com
www.flojet.com e-mail: [email protected]
APPLICATIONS
Dispense beer from a keg, cask or brew kettl
e
Both long or short draw systems
SPECIFICATIONS
Pump Design Positive Displacement, Double Diaphragm
Power Source CO
2
, Nitrogen or Compressed Dry Filtered Air
Materials of Construction (wetted parts) Polypropylene,
Santoprene®, EPDM, AISI 304 Stainless Steel
Fluid Temperature Limits 30˚ - 120˚ F (-1.1˚ - 49˚ C)
Weight 1.24 lbs. (0.56 kg.)
Dimensions 5.27” H x 3.21” W x 4.58” D
(133.8 mm x 81.5 mm x 116.3 mm)
Displacement 3.2 oz. per cycle
Self Priming Up to 10 ft. (3.05 m)
Operating Pressure 10 psi (0.7 bar) min. / 90 psi (6.2 bar) max.
Liquid Inlet Pressure 30 psi (2.1 bar) max.
Flow Rate 5 GPM (18.9 LPM) - Open Flow
Approvals NSF Listed, S-K & CE
Life / Mean Time 70,000 gallons
® A Registered trademark of Monsanto Co.
For further information, contact your FLOJET representative, or write to:
FLOJET
20 Icon • Foothill Ranch, CA 92610
Tel: 949-859-4945
1-800-2 FLOJET
Fax: 1-949-859-1153
FLOJET (EUROPE) LTD.
Unit 1, Avant Business Centre
Denbigh West Industrial Estate
Milton Keynes, Bucks, England MK1 1DL
Tel: 44-1908-370088 • Fax: 44-1908-373731
ISO 9001 Certified
AIR/GAS OPERATED
BEER PUMP
FLOJET G56 SERIES
TYPICAL INSTALLATION
CO
2
Supply
Flow Meter
(optional)
Dispensing
To we r
FOB
Detector
Dispensing
To we r
G56
Pump(s)
FOB
Detector
Beer
Engine
Keg Application Brew Pub Application Cask Application
Flow Rate GPM (L/min)
110
(7.6)
100
(6.9)
90
(6.2)
80
(5.5)
70
(4.8)
60
(4.1)
50
(3.4)
40
(2.8)
30
(2.1)
20
(1.4)
10
(0.7)
0
Discharge Pressure in PSI (BAR)
1.0
(3.8)
0
(0)
1.5
(5.7)
2.0
(7.6)
2.5
(9.5)
3.0
(11.4)
3.5
(13.2)
4.5
(17.0)
4.0
(15.1)
10 PSI LIQUID INLET PRESSURE
With 3/8" Barb Fitting
Flow Rate GPM (L/min)
110
(7.6)
100
(6.9)
90
(6.2)
80
(5.5)
70
(4.8)
60
(4.1)
50
(3.4)
40
(2.8)
30
(2.1)
20
(1.4)
10
(0.7)
0
Discharge Pressure in PSI (BAR)
1.0
(3.8)
0
(0)
1.5
(5.7)
2.0
(7.6)
2.5
(9.5)
3.0
(11.4)
3.5
(13.2)
4.5
(17.0)
4.0
(15.1)
20 PSI LIQUID INLET PRESSURE
With 3/8" Barb Fitting
Flow Rate GPM (L/min)
110
(7.6)
100
(6.9)
90
(6.2)
80
(5.5)
70
(4.8)
60
(4.1)
50
(3.4)
40
(2.8)
30
(2.1)
20
(1.4)
10
(0.7)
0
Discharge Pressure in PSI (BAR)
1.0
(3.8)
0
(0)
1.5
(5.7)
2.0
(7.6)
2.5
(9.5)
3.0
(11.4)
3.5
(13.2)
4.5
(17.0)
4.0
(15.1)
30 PSI LIQUID INLET PRESSURE
With 3/8" Barb Fitting
60 P
SI (4.13 bar) A
ir/CO
2
Inlet
4
0
P
S
I (2
.7
5
b
a
r
) A
ir/C
O
2
In
le
t
2
0
P
S
I
(
1
.3
7
b
a
r
)
A
i
r
/
C
O
2
I
n
l
e
t
80 PSI (5.51 bar) Air/CO
2
Inlet
90 PSI (6.20 bar) Air/CO
2
Inlet
60 PSI (4.13 bar) A
ir/C
O
2
Inlet
4
0
P
S
I (2
.7
5
b
a
r) A
ir/C
O
2
In
le
t
2
0
P
S
I
(
1
.3
7
b
a
r
)
A
i
r
/
C
O
2
I
n
l
e
t
80 PSI (5.51 bar) Air/CO
2
Inlet
90 PSI (6.20 bar) Air/CO
2
Inlet
60 PSI (4.13 bar) Air/CO
2
Inlet
4
0
P
S
I (2
.7
5 b
a
r) A
ir/C
O
2
In
le
t
2
0
P
S
I (1
.3
7
b
a
r) A
ir/C
O
2
In
le
t
8
0
P
S
I (5
.5
1
b
a
r) A
ir/C
O
2
In
le
t
90 PSI (6.20 bar) A
ir/CO
2
Inlet
PUMP PERFORMANCE
DIMENSIONS inches (mm)