MorrHeat MH480B User manual

Type
User manual
Waste Oil Fired Heaters
Installation, operation and service instructions
120v Manual
Page 2MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Table of Contents
Important Information Page 3
Notice Page 4
SpecicationsPage5
Hanging or Mounting of the Heater Page 6
Venting, Oil Supply Tubing, and Wiring Page 7
Oil Burner Components Page 10
Initial Start Procedure Page 13
Suggested Maintenance Page 14
ReferenceMaterialsPage15
Troubleshooting Page 16
Warranty Information Page 18
Warranty Card Page 19
Page 3MorrHeat - Most Heat In The Industry - Rev 1/31/2019
IMPORTANT INFORMATION
Taking Delivery of Equipment:
When taking delivery of your equipment, please be sure to check the shipment for any
potential damages (MorrHeat is not responsible for any damaged shipments if signed for
non-damaged).Ifanydamageisidentiedupondelivery,eithersignforasdamagedgoods
specicallynotingindetailtheapparentdamage/or/refusetheshipmentcompletelyand
besuretoleaclaimwiththeshippingcompanyimmediately regardless of the damage.
Wasteoilcontainsvariousunknownmaterialsandmayalsocontainrandomamounts
ofgasolineorothervolatilefuels.Specicsafetyandhandlingprecautionsshouldbe
consideredwhencleaning,maintainingandoperatingwasteoilheaters.
It is recommended to use a lter or some kind of strainer when pouring waste oils into the storage tank(s).
This will increase chances of catching any particulates prior to the pump lter(s) to insure a cleaner fuel
source.
WARNING:
Wasteoilheatersshouldnotbeusedinanyhazardousareasthatmaycontainammableor
volatilevaporsorevencombustibledusts.Itisnotrecommendedtouseawasteoilheaterin
anyareasthatmayhavechlorinatedorsimilarchemicalvapors.Thiswillcausedeterioration
&corrosionofthemetalstheequipmentisconstructedof(thiswouldvoidthewarranty).
Antifreezedoesnotburnandwillinterrupttheperformanceoftheunitandpotentiallyshut
downcompletelyuntilre-primedandrestarted.Iftoomuchantifreezeispresentjustlike
water,theunitwillnotre.Donotexposeunitstowater,moistureorrain.Thisisaninside
unit, not designed for outdoor use.
Oils and different Viscosities that can be burnt, but not limited to:
*UsedMotorOils*TransmissionFluid*HydraulicFluids*DieselFuels
Donotuseoldcontaminatedoilsorfuelsandkeepinmindundergroundtanksandoutdoor
oilstoragecouldhaveunknownamountsofwaterandmoisture,outsidebarrelswillleak
waterandmoisturesthroughthebunghole.
IMPORTANT:
Theinstructionsandinformationwithinthismanualareprovidedtoremindyouofany
warningsandtoassureyouhaveproperlyandsuccessfullysetuptheequipmentpurchased.
Theinformationisalsointendedtohelptheenduser/installerbeawareoftheoperations
and service required for optimal performance. These heaters are recommended for primary
oranauxiliarysourceofheatbutarenotrecommendedforuseasthesolesourceofheat
incaseofanyexpectedorunexpecteddowntimewiththeunit.Ifasteadysupplyoffuelis
notpresentorinterruptedattheburnerunit,theburnerunitwillshutdown.Beprepared
withanalternatesourceofheattoinsurethebuildingandallpipesarenotatriskoffreezing
temperatures.
Page 4MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Toinsurethebestperformance,optimalefcienciesandheatoutputoftheheatingunit,itis
recommendedandnecessarytobecomefamiliarwithyourunitandtheproceduresneeded
withinitiallystarting,running,cleaningandmaintainingtheheatingunit.
Itisimportanttorememberwhenburningusedordirtyoilsthatcontaminantscouldbe
present.Becauseofvariouscontaminates,beawareofneedingtochangelterswhen
needed.Keepthechamberandheatexchanger(s)passagewaysclean.Makesurethefuel
pump is primed and lines are free of any debris, air bubbles or interuptions.
Draftisjustasimportantastherest;baddraftcancauseseriousproblemsandnotallowthe
gasseswithintheunittocorrectlyleavetheheatingunit.Correctdraftisneededforoptimal
performance.Baddraftwillcauseover-reoroverheatingduetobottlinguptheheator
creating back pressure back in to the heating unit. If black smoke is present, bad draft, bad
combustion or both is occuring.
Improperinstallationandorneglectedmaintenancewillvoidthewarranty.Avoiding
maintenanceoftheunitcancauseoverreoroverheatingoftheunitandpotentiallycreate
cracksinrandomweldedareasoftheheatingunit.
NOTICE
Page5MorrHeat - Most Heat In The Industry - Rev 1/31/2019
MODEL MH80 MH160 MH240 MH320 MH480
BTU INPUT 80,000 160,000 240,000 320,000 480,000
BTU OUTPUT 65,000 130,000 205,000 275,000 400,000
GPH 0.5 1.0 1.5 2 3
VOLTAGE 120 v 120 v 120 v 120 v 120 v
CYCLES 60Hz 60Hz 60Hz 60Hz 60Hz
AIRFLOW 30 FT 50FT 70 FT 80 FT 100 F T
CFM's 150 0 3000 4500 6000 8500
FLUESIZE 6” 8” 8” 8” 8”
DIMENSIONS
L|W|H
L56"
W30"
H24.5"
L61"
W36.75"
H24.75"
L61"
W41"
H31.5"
L71"
W38.5"
H31.5"
L82.5"
W47"
H38.75"
HANGING
WEIGHT
204
LBS
320
LBS
423
LBS
486
LBS
714
LBS
Specifications
Heaters
Bi-Directional models avaiable in MH320 & MH480 models only.
Page 6MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Notes:
1. Allillustrationsandspecicationsarebasedoncurrentinformationavailableatthetime
of publication approval. MorrHeat reserves the right to make product changes at any
time. These heaters are designed for indoor commercial and industrial use. Installation
anduseofthiswaste-oilburningapplianceshallbeinaccordancewiththeStandardfor
theInstallationofOilBurningEquipment-ANS/NFPA31-2016,andNationalElectricCode-
ANSI/NFPA70-2017andtherequirementsoftheinspectionauthoritieshavingjurisdiction.
2. Output depends on viscosity of oil being burnt.
3. Air Pressure for all fuels 8 - 14 P.S.I (preset by MorrHeat).
4. Suggestedmaximumoutletairtemp.200degreesF.(93degreesC).
5. Clearance from all combustible materials on all models should be no less than:
MOUNTING DIMENSIONS:
MODEL A B
HANGING OR
MOUNTING THE HEATER
A
B
Whenmountingtheheater,makesuretheheatingunitisatleasttwentyinches(20”)away
fromanycombustiblematerials.Aminimumofthirtysixinches(36”)awayfromthefrontof
the unit is recommended.
TOP- 20” BOTTOM- 20 SIDES- 20
REAR- 20” FRONT- 36” FLUE PIPE- 20”
MH80 32" 13"
MH160 35.25" 22"
MH240 35.5" 25"
MH320 45.25" 25"
MH480 57.5" 30.5"
Page 7MorrHeat - Most Heat In The Industry - Rev 1/31/2019
FUEL SUPPLY LINES
Useonly3/8”IDcoppertubingwitharettingsfromthetanktothefuelpumpassembly
andthefuelpumpassemblytotheheatingunit.Ferrulettingsarenotrecommended
andTeontapeisnotneeded.UsingaTeontapeorliquidsthatdryonthethreadsin-
creasesthepotentialofcreatingapieceorakeofthematerialthatcouldblockpassage-
ways.
Alwayskeepthefuelsuctionlineatleastsixtoeightinches(6”-8”)fromthebottomof
theoilstoragetanktopreventsuckingwaterandsludgefromthebottomofthetank.
Drainwaterandsludgefromthebottomofthestoragetankwhenneeded.
It is recommended to use an inside supply tank vs. an outside or underground tank. If
pullingfromanundergroundtankitispossibleasecondarytransferpumpwouldbe
needed(NotProvided).Outsidestoragetanksorbarrelscanhavewatermixedinwiththe
fuelsupply.Thiswillcreateissues(NotRecommended).
Thefuelpumpassemblythatcomesstandardwitheveryunitneedstobemountedat
tanklevelorbelow.Settingthefuelpumpassemblyatgroundlevelwillfunctionproper-
ly.Thefuelpumpwillpushoilupto100fthorizontal&upto25ftvertical.
VENTING INSTALLATION
1. When installing the vent pipe, be sure all connections are fastened correctly to insure no
leaks and proper draft is achieved. Minimum draft through the unitis,-.02-whencheck-
ingthroughthesightorameinspectionportdirectlyabovetheburnerassembly,with
draftmeter.Draftupthestackmustbe-.04to-.06inchesofwatercolumnwhencheck-
ing a draft meter for proper draft readings.
2. Ifproperordesireddraftisn’teasilyachieved,athirdpartydraftinducerorpowervent
may be needed to prevent back draft from occurring (not provided).
3. Install a barometric damper (NOT included) in the stack only if the draft up the stack
exceeds-.08.Draftupthestackmustbe-.04to-.06inchesofwatercolumn.Checkwith
draftmeterbetweenthetopoftheheateranddamper.The draft should be a minimum of
-.02-checkedthroughameinspectionport.
4. Keepthedraftmoving.Ifdraftistoosloworbottlesup,thiscouldcreateabackdraftand
over-reoroverheattheunit.Ifadamperispresent,losingthedamperwillincreasedraft
makesurepassagewaysarecleanandclear.
Page 8MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Besurewhenprimingorbleedingthefuelpumpthatyouallowenoughtimetocompletely
burpanyandallairwithinthesystemoutofthefuelpumpandfuellines.Ifanyskipsor
slightinterruptionsarestillpresentinthesystem,itislikelytheunitwillnotproperlyignite
orrunwithoutasteadyandconsistentfuelsupply.Theamesensorneedstorecognize
ameinthechamberoritwillnotignite.
Itisnecessarytoconnectthe3/8”IDcopperfuellinefromthestoragetanktothelter
housing, to the fuel pump inlet that is located on the same side as the bleeder valve. Once
connections are secure, continue the fuel line from the fuel pump assembly to the burner
assembly.
WIRING
Youwillneedtowire120vpowerintothemain electricalpanelmounteddirectlyonthe
backsideoftheheatingunitwithseparate20ampcircuitprotectionusing12-gaugewire.
Makesuretoconnectthepowerlinetotheblackwireandallwhitewireswhichareneutral
orcommontogether.It’sveryimportantthatthegroundwiregetsconnectedtoamounting
pointwithinthemainjunctionboxoratleastgrounded.
Wiresfromthemainjunctionboxneedtobeconnectedtothefuelpumpassemblypower.
Yellowconnectstoyellowandtheneutralorcommonconnecttogether,whichiswhiteto
white.
ThelowvoltagethermostatneedstobewiredtotheT”terminalsontheoilprimary,located
onthetopoftheburnerassembly.(wirediagrampg.10)
NOTICE
Installationanduseofthisproductshallbeinaccordancewiththestandardforoilburning
equipmentANSI/NFPA31-2016alongwiththenationalelectriccodeANSI/NFPA70-2017,the
requirementsoftheinspectionauthoritieshavingjurisdiction.
Page 9MorrHeat - Most Heat In The Industry - Rev 1/31/2019
120v Schematic
BACK PANEL
CABINET
FUEL PUMP
Page 10MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Oil Burner Technology
MorrHeat’swasteoilburnertechnologyimprovestheefciencyoftheoilburnprocessby
continuouslyburningthewasteoilwithnointeruptions.
ThewasteoilentersintotheOilPre-HeaterBlockandispre-heatedtoaspecictemperature
setpoint. Then compressed air from the air compressor is infused with the oil prior to
spraying out the nozzle by breaking up the oil particles into a ner mist or spray. The
electrodes mounted above the nozzle provide an electrical arc across the electrodes to
ignitethe neoil mist as it sprays out of the nozzle. Onceignited the ame is forced
intoavortexcausedbytheburnersblowerandameconeprovidingaveryefcientand
thorough burn.
(See page 12-13 for parts & components)
P a g e 11MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Igniter Transformer: Supplies high voltage to the electrodes generating
electrical arc igniting the oil. Transfers the high voltage from the igniter
transformer to the electrodes.
SolenoidOilValve:Openswhenburnerisrunningandcloseswhenburneris
not running eliminating bleed back of oil out of the Pre-heater block.
AirBand:Adjustsamountofairintroducedintothecombustionchamber.Air
bandisadjustedatthefactoryforoptimumperformance,closedto1"inch
open.
Oil Primary Control: Controls the oil burner ignition. Checks for ame in
thecombustionchamber,ifnoameisdetectedwithin45seconds,theoil
primarywillshutdowntheoilburner.Torestarttheunit,resettheredbutton
ontheoilprimary.Hardlock-outmayrequireholdingtheresetfor30-45
secs.
Oil Pre-Heater Block: Pre-heats the oil and air before entering combustion
chamber.
PhotoEye:Sensesameincombustionchamberandsignalsoilprimarywhen
noameispresent,toshutdownorlock-outthesystemfromoperating.
AirPressureGauge:Displaysairpressuresuppliedbyonboardaircompressor.
(8-14 PSI depending on unit)
AirMufer/Filter:Filtersairandquietsthesoundgeneratedbythecompressor.
Pre-Heater Control Circuit Board: Controls temperature of the Oil Pre-Heater
Blockandcontrolssafetyfeatureofnotallowingburnertoenergizeuntil
oilhasestablishedoperatingtemperaturesetpointorshutdownburnerif
Pre-HeaterBlocktemperaturefallsbelowshutdowntemperaturesetpoint.
Oil Burner Components
P ag e 12MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Electrodes: Provides continuous high voltage electrical arc from electrode to
electrodeignitingthewasteoilasitisbeingsprayedoutofthenozzle.
Nozzle:Low-pressurenozzle.(3pc.andcleanable)
FlameCone:Flameconeforcestheameintoaswirlpatternimprovingthe
ameforacompleteburn.
BurnerMotor:Multitaskmotorturnstheburnerblowerandintegratedair
creates combustion and atomization air at the same time.
Air Pressure Adjuster: Adjusts the air pressure going to the pre-heater
block.Shouldbeadjustedbetween8PSIand14PSIasindicatedontheAir
Pressure Gauge.
OilFilterWithHousing:Thefuellterwithhousingallowsaneasyspinon/
offfeaturemakingitsimplewhenchanginglters.Pre-lterstheoilprior
to the burner.
PowerIndicator:Indicateswhenpowerispresentattheburner.
Run Indicator: Indicates that the burner is ready for operation after the initial
pre-heat, this process could take 3-4 minutes to pre-heat the system.
Suntec/WebsterFuelPump:Singlestagefuelpumpwillpushthewasteoil
25ft.vertical,and100ft.horizontal.(Alwaysrunfuellinesuptotheburner,
neverdown,oryoucouldcreateanairpocketinthesystem-HardtoBleed)
P a ge 13MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Initial Start Procedure
1. Make sure the heating unit and all components have been properly and securely installed.
2. Checkthatallelectricalconnectionsandhook-upsareproperlywiredandconnected.
3. Itisrecommendedpriortoprimingthefuelpumpandbleedingtheairtopre-llthefuel
ltertohelpspeeduptheprocess.Forasecondarycheckyoucanalwayspressurizethe
fuellinestoeliminateanypotentialleaksinthelineorttings.Consistentfuelsupplytothe
burner is very important.
4. Check that venting connections are properly installed and connected from the heating unit.
5. While rst starting the unit it may take several minutes to get the oil in the pre heater
block up to temperature. Once the oil reaches the desired temperature, oil is then supplied
through the fuel pump assembly and burner assembly. Make sure burner and pump are
turned on.
6. Optimaldraftwhenrunningtheunitisanotherveryimportantpartoftheprocess.Besure
desireddraftisachievedwhileburnerisrunning.Ifexhaustfansarepresentinthebuilding,
itispossibleyouwillneedadraftinducerorpowerventofsomekind(notprovided).
7. Thermostatmustbeoffwhilesupplyingpowertotheburnerassembly.
8. Aftertheoilinthepreheaterblockhashitthedesiredtemperature,whiletheburneris
running,brieyjumpthe“F”terminalsontheoilprimarytoallowtheburnertorunduring
the fuel pump and priming procedure.
9. Afterbleedingthefuelpumpandameisestablishedattheburnerassembly,removethe
temporaryjumpersonthe“F”terminalsontheoilprimarycontrol.Thisallowsthesafety
features of the controls to operate properly.
10. Adjustairpressureto8-14psiifneeded.(canvaryduetogeographicarea)(presetfrom
manufacturer)
11. Air band on the side of the burner assembly should be closed to 1” open (pre set from
manufacturer)Opentoofarcancausedelayedstartornore.
13 . Afterproperlyrunningandallminoradjustments,ifany,aremade(presetfrommanufacturer)
Checkinspectionportforbrightyellownotorangeame.
14.Flameshouldbehalfwayorlessdownthechamber.
15.Useadjustmentscrewontheaircompressortoachieveproperair(8-14psi)
16.Contactinstallerormanufacturerforfuelpumpadjustmentifneeded
DONOTSTARTHEATERWHENDELAYEDSTARTHASOCCURREDANDCHAMBER/HEAT
EXCHANGERSAREHOT,LETUNITCOOLBEFOREATTEMPTINGANOTHERRESTART&
CHECKFORACCESSIVEOILINTHECHAMBERPRIORTORESTART.TOOMUCHOILINTHE
CHAMBERUPONRESTARTCANCAUSEABACKFIREINTHECOMBUSTIONCHAMBER.IF
TOOMUCHOILISPRESENT,ITISRECOMMENDEDTOCLEANORWIPEUPASMUCHAS
POSSIBLEBEFOREARESTARTTOAVOIDTHISFROMHAPPENING.
Page 14MorrHeat - Most Heat In The Industry - Rev 1/31/2019
SUGGESTED MAINTENANCE
ITISRECOMMENDEDTHATYOURFACILITYGETSONAREGULARMAINTENANCESCHEDULE
ANDORSETREMINDERSOFCLEANINGANDMAINTENANCEOFTHEHEATINGUNIT,TANK,OIL
FILTER,AIRFILTERSANDALLOTHERWORKINGCOMPOENTSANDCONSUMABLESTHATMAY
NEEDATTENTIONORREPLACEDBEFOREORDURINGSEASON.
Make sure the unit is clean prior to every heating season
HIGHLYRECOMMENDEDTOTURNPOWEROFFORUNPLUGTHEBURNERUNITWHEN
CONDUCTINGCLEANINGANDMAINTENANCE
Monthly:
Check the ash build up periodically for optimal performance
Removeallashwhencleaningthecombustionchamberandheatexchangers.Theviscosity
andoil’sbeingburnt,cleanlinessoftheoilandruntimeplayafactorwhendetermininga
maintenanceschedule.Everyenduserwillhavealittledifferentschedulewithallfactors
considered for every location and application.
Checkorchangeoillter
Checkorchangeairlters
Cleanameconeifneeded
Twice Per Season:
Cleanorchangefuelpumplter.Fuelpumpcovercomesofftoaccesslter,gasketinside
may also need to be replaced.
Inspect,adjustorreplaceelectrodesifneeded(Seepartdescriptionfordesiredsetting)
Drainexcesswaterandsludgefromfuelstoragetank(s)
Once Per Season:
Removeashbuildupwithintheventpipe
Replacenozzleifneeded(willerodeovertime).Whenreplacingmakesurethenozzlesticks
slightlypasttheendcone(1/4”pastinsideradiusofamecone)toinsurenobuildupofoil
occursatthenozzleandamecone.
Check thevanes and carbonplatesforanychips,cracksor wearwithintheonboard air
compressor, replace vanes and carbon plates if needed.
The cleaner the unit, the better it performs and longer it lasts!
Page15MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Electrode Adjustment Reference
When cleaning, inspect all
three pieces thoroughly.
NOZZlE ASSEMBLY REFERENCE
SnapSwitch
Thermocouple
Pre-Heater Control Board
Pre-Heater Oil Block
Electrodes
Nozzle
Combustion Chamber & Heat
Exchanger Clean-out Door Reference:
CleanOutDoors
HeatExchangers
Combustion Chamber
CleanOutDoors
Vent Port
HingedDoors(2)
Burner Mount
Chamber Sight Port
3/8 from tip/center of
nozzle ush with the
Electrodes.
Electrodes
3/16evenbetweenElectrodes
Heat Rod
Page 16MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Troubleshooting
1. Heater shuts off
2.Lossofprime
overnight
▲Manualreset
▲Vacuumairleakinairline
▶Pluggedlterortankempty
▼Pluggedpumpscreen
▲Requiredmanualreset
▲Tightenallfuelconnections
▶Checkpumpscreen
▼Cleanlter(useventport),reprimepump
3.Fails to Start ▲Vacuumleak
▲Inadequatefuelsupply
▶Nopressure
▶Nopre-heat
▶Autostartcircuitnot
functioning
▶Noarc
▶Noairpressure
▲Openbleederportifairispresent.
▲Cleanlter.Checkallfuelconnections.Tightenttings.
▶Check,mayneedcleaning-toaccess,remove,pumpcover.
▶Useventport,andreprimepump.
▶Besureallwiringtopre-heateristight.
▶Badheatrod-replace.
▶Checkcircuitcontrolboardandreplaceifnecessary.
▶Checkcontinultyatterminalsofheatrodlimitsnapswitch.
▶Checkspringstoelectroderodadjustment(undertransformer)-make
sure they have good contanct. Open burner door and make sure electrode
tipsaren'ttouchingamecone.
▶Checkpressureregulatorandadjust.Checkairsupplylinefor
restrictions or leaks. Pull compressor cover and inspect carbon vanes.
Mayneedtoreplace.Checklter,cleanifneeded.
4. Reduced air pressure
and can’t increase
▲Gaugemaybebad.
▲Intakeltermuferisplugged
withdustordirt.
▶Exposedtowinter
▼Compressorvanesmaybe
worn
▲Replacegauge
▲Remove&cleanwithcarburetorcleaner,drythoroughly.Donotuse.
▶Removecover,cleanrustwithemerycloth
▼Replacecarbonvanes
5.Hardstarting
(Diminishedame)
▲Pariiallypluggedlter.
▶Restrictioninnozzleusually
onlywheninitiallyinstalled.New
lines may have foreign material
in them.
▶Airbandopentoofar
▼Outoffuel
▼Nooiltoburner
▲Cleanlter.Usingventport-reprimepump
▶Removenozzleandcheckforforeignobjects
▶Aluminiumblockpre-heaterinsideburnershouldnotbuildupcarbon.
If carbon present, pre-heat circuit is malfunctioning. Thermocouple heat
sensorwirecouldhaveopencircuit.Heatcontrolboardmayhaveblown
circuit and circuit board fuse. Inspect both and replace either if needed.
▶Closeairband-whileviewingame;openairbandslowlyunitl
combustion chamber a clear, not orange
▼Rellstorage
▼Cleanpumpscreen-removepumpcover.Usingventport,re-prime
pump.
Problem
Cause Suggestion
Mostlikely|| Lesslikely|| LeastLikely
P a g e 17MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Ifyouexperiencingtechnicalorservicingissuesandhaven't
beenabletodiagnoseandxthepotentialissue,pleasecontact
uswithanyquestionsMonday-FridayPST.AthirdpartyHVAC
or mechanical contractor may, need to be contacted if trouble
shooting over the phone still does not solve the potential issue. If
a third party is involved MorrHeat is not responsible for any fee
associatedwiththeserviceprovidedbyathirdparty.
Attention
6. Heater cycles
frequently,without
set temperature being
reached
▲Heateroverring
▶Highlimitsafetyswitchbad
▼Temperaturesettingwrong
▲Investigateandlocatereasonforoverring.I.enozzleeroded,pump
not functioning properly, decrease pump motor speed.
▶Replacehighlimitfansafetyswitch
▼Checktemperaturesettingandadjustasnecessary.
7. Heater rumbles and
excessiveheatblowback
fromamevisionport
▲Pumpsettingwrong
▼Draftincorrect.Ifproperdraft
can't be achieved. Heater could
haveexcessiveamountofash
andwon'tallowsufcent
draft
▲Pumpnotfunctioningproperly-overring.MayneedRPMreadjust.
Resetameslightlylessthan1/2waydowntubecombustionchamber.
Useadjustmentknobonpumpmotor.
▼Setdraft.Cleanoutcombustionchamberandexchangersofash.
Check draft-reset if needed.
8. Heater establishes
amebutlocksoutor
shuts off. Need to reset
primary.
▲Photoeyecan'tseeame
▼Duetobackdraft.Flameend
cone may have ash.
▲Cleanphotoeyewhichissmokedupbybackdraftsmoke.
▼Swingopenburnerdoorandcleanashbuildupfromameendcone.
9. Proper draft setting
can't be achieved
▲Negativedraftinbuildingor
exhaustfanspresent.
▼Excessiveashbuildup/heater
▲Mayneedtoinstallpowervent/draftinducer'sinstack.
▼Cleanashandsootfromcombustionchamberandheatexchangers.
10. Poor or reduced heat
production
▲Flametoosmall
▶Excessiveashbuildup
exchangers
▶Throughvisionport,check
ametoseeifameissmaller
than usual.
▼Entirefuelsupplymaybe
plugged.
▲Nozzlemaybepluggedwithdebris-usuallyafterlteriscleaned.
▶Cleanashfromcombustionchamberandexchangers.
▶MayneedtoreadjustpumpRPM.(Useknobonpumpmotor).
▼Cleanlterboth,oilstrainerandoilpumpscreen.
Page 18MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Warranty Information - 10 Year
MorrHeatwarrantsthematerialsandworkmanshipwillbefreeofdefectsforthedurationof
thewarrantyspecied.Warrantyisvalidfromthedateofdeliveryandwarrantycardmustbe
sentintoMorrHeatwithin30daysofdeliverydate.MorrHeatisnot responsible for damaged
goods. Please check your shipment for any damages. If damages are apparent, either sign
for the shipment as damaged goods and le a claim immediately or refuse the shipment and
le a claim immediately. Nothing can be done for damaged goods that have been signed for
non-damaged,theshippingcompanywilldenythoseclaimsifledandMorrHeatwillnotbe
responsible.
Warranty is void if heating unit is improperly installed and neglected of proper routine
maintenance. Warranty is also void if contaminants and corrosives have been attempted or
burnt in the heating unit. Chemical’s such as, but not limited to, chlorine can deteriorate the
metalswhenintroducedtohightemperatures.
Ifa defecthasoccurred(badmetals,weldsetc.),MorrHeatreservestheright todetermine
ifthedefectcanberepairedoracompleteunitswapisnecessary.Picturesoftheunitand
potential defect will be required. All returned items must be approved by MorrHeat and
returnedwithaRA#(returnauthorizationnumber).PleasecallMorrHeattoacquiretheRA#
information and process.
MorrHeat's warranty covers the combustion chamber, heat exchanger(s) and framework.
Warrantyisfordurationoften(10)yearsinwhichtherstve(5)yearsisafullwarrantyrepair
orreplacementandthelastve(5)yearsisafty,fty(50/50)splitonrepairorreplacement.
ThePre-Heaterblockhasaten(10)yearfullwarrantyandMorrHeatextendsthemanufacturer's
warrantysubjecttotheirtermsandconditions,one(1)yearonallotherpartsandcomponents.
Warranty is Void if
*
:
*
Warrantycardisnotreturnedwithin30daysofdeliverydate
*
Parts or equipment have
been altered from original manufactured state
*
Installed improperly
*
Maintenance has
been neglected
*
Heater has been misused
*
Wired incorrectly
*
Unithasbeenoverredor
over heated
*
Unithasbeenoperatedincontaminatedconditionsorexposedtocorrosive
chemicals, such as but not limited to chlorine
*
Warranty is not transferable
*
MorrHeat is not
responsibleforadditionallabororfreightchargesunlessthereiswrittenanddocumented
arrangements and authorization from from MorrHeat.
Page 19MorrHeat - Most Heat In The Industry - Rev 1/31/2019
DateofPurchase:
Serial#:
Model#:
Customer (Company) Name:
Address: City:
State: ZipCode:
Contractor:
Address:
City: State:
ZipCode:
Installed By:
REMINDER:
Warranty coverage is specic to the materials and workmanshipofthe unit and does not
coveradditionallaborandfreightchargesunlesswrittenauthorizationisprovided.Warranty
assuresandcoversweldswhenmaintainedandusedproperlybutdoesnotcoverstresscracks
causedbyexcessiveheatoroverre.Baddraft,backdraftorsimplytoomuchfuelandtoo
largeofameareadirectcauseofanoverreoroverheatedunit.Neglectedmaintenance
andcleaningtheunitisanotherdirectcausetooverringoroverheatingtheunit.Keepyour
unit clean and maintained properly for best performance and longevity of the unit
WARRANTY CARD
Warrantycardmustbelledout&Returnedwithin30daysofdeliverydate
If return is deemed necessary for warranty evaluation and determination of repair or
replacement,unitheateristobesenttoMorrHeatwithfreightprepaid.MorrHeatreservesthe
right to determine appropriate action for repair or replacement.
NopartswillbeacceptedbyMorrHeatwithoutRA#(returnauthorization
number) clearly marked on outside of shipping package. Obtaining RA#
requires model and serial numbers, description of part being replaced and
natureofdefect.CallfactorytoreceiveRA#.
Page 20MorrHeat - Most Heat In The Industry - Rev 1/31/2019
Parts Included:
Waste oil heater (1)
Waste oil burner assembly (1)
Wasteoilfuelpumpassemblywithspinonlter(1)
Thermostat (1)
Draftmeter(1)
What is Included
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

MorrHeat MH480B User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI