GetInLight IN-0317-3-SN-40 Installation guide

Category
Floodlights
Type
Installation guide
1 2
3 4
5 6
Package Contents
A 1
B 1
C 1
D 4
E 4
aa 1
bb 2
Warranty
5-YEAR LIMITED WARRANTY
The manufacturer warrants this product to be free from defects in materials and workmanship for a period of five (5) years from date of purchase. This
warranty applies only to the original consumer purchaser and only to products used in normal use and service. If this products is found to be defective,
the manufacturer's only obligation, and your exclusive remedy, is the repair or replacement of the product at he manufacturer's discretion, provided that
the product has not been damaged through misuse, abuse, accident, modifications, alterations, neglect, or mishandling. This warranty shall not apply to
any product that is found to have been improperly installed, set-up, or used in any way not in accordance with the instructions supplied with the product.
This warranty shall not apply to a failure of the product as a result an accident, misuse, abuse, negligence, alteration, or faulty installation, or any other
failure not relating to faulty material workmanship. The manufacturer specifically disclaims any liability and shall not be liable for any consequential or
incidental loss or damage, including labor/expense costs involved in the replacement or repair of said product.
Piece Quantity
Fixture Pan
Acrylic Diffuser
Decorative Ring
L-angles
Thumb Nuts
Scews for Fixture Mounting
Wire Nuts
Description
B
A
C
D
E
aa
bb
Contact the Customer Service Team at [email protected] or visit www.getinlight.com
Installation Guide
Integrated LED
Flush Mount Fixture
Model #
IN-0317-1-XX-XX, IN-0317-2-XX-XX,
IN-0317-3-XX-XX, IN-0317-4-XX-XX.
ATTACH YOUR RECEIPT HERE
Purchase Date __________________
Contact the customer service department at [email protected]
We commit to respond to emails within 24 hours - and sooner, if possible!
We are devoted to solving problems and offering the best service to our customers.
Questions, problems, missing parts?
PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING
INSTALLATION AND RETAIN FOR FUTURE REFERENCE.
is registered trademarks of Inlight Co. Ltd. All Rights Reserved.
1 2
3 4
5 6
Safety Information
Pre-Installation
PLANNING INSTALLATION
TOOLS REQUIRED
● Phillips Screwdiver ● Ladder ● Safety Goggles
● Wire Cutter ● Wire Stripper
DIMMABLE FUNCTIONALITY
MAX. LOAD
600W
600W
150W
300W
300W
DV-603PG 600W
DVELV-600PLUTRON
LUTRON
PD-6WCL-WH
INCANDESCENT / HALOGEN
PART NO.
DVCL-153P
MANUFACTURER
LUTRON
LUTRON
LUTRON
DV-600P
INCANDESCENT / HALOGEN / CFL / LED
INCANDESCENT / CFL / LED
INCANDESCENT / HALOGEN
CFL / LED
MAGNETIC LOW VOLTAGE
MACL-153M
IMPORTANT SAFETY INSTRUCTIONS
LUTRON
TYPE
Note:
Safely dispose of packaging materials. Assistance
will be required to support fixture during
installation.
● To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards read all warnings
and instructions included with and on the the fixture box and all fixture labels.
● Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
● Commercial installation, service and maintenance of luminaires should be performed by a qualified licensed electrician.
● For Residental installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check
your local electrical code.
● DO NOT INSTALL DAMAGED PRODUCT!
● This fixture is intended to be connected to a properly installed and grounded UL listed junction box.
● These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with
installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for
the purchaser’s or owner’s purpose, this matter should be referred to Inlight Co. Ltd.
WARNING: RISK OF ELECTRICALSHOCK
● Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
● Turn off the power when you perform any maintenance.
● Verify that supply voltage is correct by comparing it with the luminaire label information.
● Make all electrical and grounded connections in accordancewith the National Electrical Code and any applicable local code requrirements.
● All wiring connections should be capped with UL approved wire connectors.
CAUTION: RISK OF INJURY
● Wear gloves and safety glasses at all times when removing luminaire from carton,installing, servicing or performing maintenance.
● Avoid direct eye exposure to the light source while it is on.
● Account for small parts and destroy packing material, as these may be hazardous to children.
WARNING: RISK OF BURN
● Allow fixture to cool before handling. Do not touch enclosure or light source.
● Do not exceed maximum wattage marked on luminaire label.
● Follow all lamp manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods,
replacement, and recycling.
CAUTION: RISK OF FIRE
● Keep combustible and other materials that can burn away from luminaire and lamp/lens.
Compare all parts with the parts listed in the package contents section. If any part appears missing or damaged, do not install and use this light. Contact
customer service.
This fixture is dimmable with most regular dimmers. Following dimmers tested to be compatible with this fixture, dimming range up to: 10%-100%.
If you are unfamiliar with electrical installations, it is recommended you have a qualified electrician do your installation.
***CONSULT A LOCAL LICENSED ELECTRICIAN OR ELECTRICAL CONTRACTOR IF YOU ARE NOT SURE ABOUT THE INSTALLATION.***
1 2
3 4
5 6
Mounting Location Disconnect Power
- - Place the wall switch to the "OFF" position. (Fig.1.)
- Depending on which type of fuse box you have in your home:
-
Fig.2.
OR
Plan the layout of the fixtures and ensure power wiring is routed
to all installation locations.
A 3" or 4" junction box must be installed at each desired location
before installing the fixture.
Junction Box (Not included)
• 3" & 4" square or octagon
• At least 1/2” deep
Fig.3.
-
-
Unscrew the four thumb nuts from fixture Disassemble the fixture
- Twist counterclockwise to loosen the thumb nuts - Remove the decorative ring, L-angles and diffuser.
Remove the protection foam and discard it. Do not remove any
other parts.
- Remove the thumb nuts from fixture.
SECTION A: PREPARING FOR INSTALLATION
1 2
1 2
SECTION B: MOUNTING INSTALLATION
Note: To avoid damaging this product, place the components on
a soft, non-abrasive surface such as carpet or cardboard.
Diffuser
Thumb Nuts
B
A
Decorative Ring
C
D
Thumb Nuts
A
Diffuser
B
Protection Foam
Remove and discard it
-
Place either the main (Master) switch to the "OFF" position,
cutting off power to your entire home OR turn off the individual
switch that provides power to where the fixture will be installed
Place either the main (Msster) switch to the "OFF" position,
cutting off power to your entire home OR turn off the fuse
that provides power to where the fixture will be installed
Carefully unpack the fixture. Lay out all parts on a clean
surface.
Remove the old fixture.
Fig.1
Wall Switch
Fig.2
Breaker Panel
Fig.3
Fuse Box
L-angles
1
1 2
3
4
5 6
Connect the wires
- Pull the power supply wires out from the junction box, strip 3/8" of bare
power supply wires.
- Hold two wires of the same color(one from the fixture, one from the junction
box) next to each other and make sure the two stripped ends sit tightly against
each other to gurantee effective connection later (but do not twitst wires),
See .
- Push wires firmly into wire nut (bb). Use your fingers, twist wire nut clockwise until tight. Check for tightness by pulling wires, See .
- Ensure the connectors are spliced tightly and carefully push the spliced wires back into the junction box.
Ground Wire:
- For safety and proper operation, the fixture must be properly
grounded.(If house wiring does not include a ground wire,
consult your local electrical code for approved grounding methods).
- A green or bare copper ground wire is preattached to the fixture.
The fixture ground wire must be spliced to the green or bare
copper ground wire in the junction box using one of the wire
nuts (bb).
Power Wires:
- Connect the NEUTRAL supply wire (White) from the junction
box to the NEUTRAL fixture wire (White)
- Connect the HOT supply wire (Black) from the junction box
to the HOT fixture wire (Black)
5
SECTION B: MOUNTING INSTALLATION (CONT.)
Note: Ensure that no bare wires are exposed after making the
connections.
Install the hardware
- Use either the existing junction box screws or
the mounting screws (aa) included in the hardware kit.
- Drive the screws into the junction box until there is
abount 3/8 inch between the ceiling and the under
side of the screw head.
3
Note: This fixture does not use a mounting breaket to
secure it to the junction box.
3/8 in.
1 cm
Junction Box
(Not Included)
Scews
aa
Wire Nuts
bb
2
LED Driver
LED Driver
Note: 4-inch keyhole slots location illustrated.
Note: 16-inch or 18-inch fixture do not has
the 3-inch keyhole slots.
Note:
1 2
3 4
5 6
Do not use power tools to install the screws, and do
not overtighten the screws! Overtightening the screws
may cause the fixture to warp and thus make assemble
the fixture difficult.
Install the fixture
- Locate the keyhole slots on the fixture pan.
- Align the wider end of keyhole slots on the fixture pan with screw heads on
the mounting plate, push fixture pan towards the mounting plate until screw
heads go through the key hole slots.
- Once both screw heads have passed through the keyholes, twist the fixture pan,
until both screws are situated at the narrow end of the keyhole slots.
- Hold fixture pan in place and tighten the screws (aa) just enough
without distorting or damaging the fixture.
6
SECTION B: MOUNTING INSTALLATION (CONT.)
Front View
Twist Clockwise
to Lock
Rotate the fixture pan Secure the fixture
7 8
- Rotate the fixture pan to a desired angle to match the layout of
the room.
1 2
3 4
5
6
Assemble the fixture Rotate the fixture to the desired angle
-
-
-
- Turn on power at circuit breaker or fuse box.
Seat the diffuser in the decorative ring.
Place the diffuser and decorative ring against the fixture pan
mounted on the ceiling. The threaded end of each thumb will
need to pass through the holes in the ring for the ring to be
installed.
Once in place, hold both the diffuser and the ring in place,
attach the L-angles, then the thumb nuts to secure the
decorative ring.
- Turn the light switch on to activate the fixture.
Problem Possible Cause Corrective Action
Fixture doesn't light.
Fuse blows or circuit breaker trips when light is turned on.
Light flickers during dimming
SECTION B: MOUNTING INSTALLATION (CONT.)
9
Note: Assistance will be required to support the
diffuser during installation.
10
SECTION C: TROUBLESHOOTING
1. Power is off.
2. Defective wall Switch.
3. Bad connection
1. Check if power supply is on.
2. Replace switch.
3. Check wiring.
1. Overloaded circuit
2. Short circuit.
1. If wiring connections are loose or disconnected,
redo the connections. Make sure that there are no
exposed wire conductors.
2. Discontinue use and call customer service.
Check if dimmer being used is in
compatible dimmer list from "dimmer"
section
If dimmer is not on the list, replace it with a dimmer
listed.
V. 2019
Questions, problems, missing parts? Before returning to the store,
contact Inlight Customer Service
Retain this manual for future use.
is a trademark of Inlight Co. Ltd.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

GetInLight IN-0317-3-SN-40 Installation guide

Category
Floodlights
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI