Hikvision DS-19A08-01BN Quick start guide

Type
Quick start guide

This manual is also suitable for

Hikvision DS-19A08-01BNG is an advanced security control panel designed to safeguard your property. With 8 zones and 4 partitions, it offers flexible protection for homes, offices, and small businesses. It supports various wired and wireless detectors, allowing you to customize your security system according to your needs. The built-in tamper protection ensures reliable operation, while the clear LCD display and user-friendly keypad make it easy to operate.

Hikvision DS-19A08-01BNG is an advanced security control panel designed to safeguard your property. With 8 zones and 4 partitions, it offers flexible protection for homes, offices, and small businesses. It supports various wired and wireless detectors, allowing you to customize your security system according to your needs. The built-in tamper protection ensures reliable operation, while the clear LCD display and user-friendly keypad make it easy to operate.

1
2
Operation via
Client Software
Testing
Powering On
Wiring
Network
Security Control Panel
with Bus Extension Module
Quick Start Guide
Connect the keypad, alarm output, trigger, and power cables,with following the figure below. Power down the control panel
before connecting and disconnecting accessories and peripherals.
Step 1 Wiring
The keypad registraon will be completed in 1 minute aer the control panel
being power on. The system then will complete the start-up and enter the
properly status of working in 20 seconds.
While the registraon is succeeded, the working status indicator of LED keypad will
turn green.
The display demonstraon of LCD keypad aer powering on is shown below.
HIKVISION
20XX.XX.XX XX:XX:XX
VX.X.X build XXXXXX
Step2 Powering On
Dry Contact Dry Contact Dry Contact Dry Contact
2.2K
NC
C
Z
G
Peripheral Security Detector
NC Detector
2.2K
NO
C
Z
G
Security Control PanelSecurity Control Panel Security Control Panel
NO Detector
Peripheral Security Detector
Zone
Zone
Alarm Output
KeypadPower Supply
G Z4 G Z6Z5 G Z8Z7GZ1 Z2 Z3
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
NO/NC1
COM1 COM2 COM3 COM
NO/NC2 NO/NC3 NO/NC4
G Z4 G Z6Z5 G Z8Z7GZ1 Z2 Z3
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
TX RX G
Printer
Dry Contact Dry Contact Dry Contact Dry Contact
D
+ +
D G12V
-
Keypad
DC_IN +
GBAT _
+12V G
+12V G
14.3V DC
Power
12VDC 7AH
Lead-acid
Alarm
Bell
Auxiliary
Power
Interface
BELL AUX
Network Data Indicator
14.3 Power Indicator
Reset
TAMPER1
BELL AUX
FUSE
KEYPAD
Network Status Indicator
Working Indicator
3.3V Power Indicator
G Z10Z9
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
G Z12Z11
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
G Z14Z13
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
G Z16Z15
N.O N.O
2.2K
EOL
2.2K
EOL
N.C N.C
Z9 to Z16 are only supported by the network security control panel with 16 zones.
Power Indicator
Telephone Module
Handset Incoming
Phone Line
GPRS Module
DC
Unoccupied Zone
NO/NC1
COM1 COM2 COM3 COM
NO/NC2 NO/NC3 NO/NC4
The resistance of 2.2KΩsupports
tamper-proof and non-tamper-proof
wiring.
The resistance of3.3KΩ, 5.6KΩor
8.2KΩ only supports non-tamper-proof
wiring.
BUS1- BUS2- BUS2+BUS1+ GG
M-BUS 1 M-BUS 2
5V Power Indicator
Bus Power Indicator
13.8V Power Indicator
15V,-24V Power Indicator
M-BUS Module
UD07394B
34Step4 Operation via Client Software
Arm/Disarm
Clear Alarm
Test
Acvate Device
1
1
2
2
Add Device
3
Path: Device Management -> Server -> Online
Note: You should acvate the device for the first usage.
Path: Device Management -> Server -> Add Device
Input the device nickname, IP address, user name, and
password, and click Add.
Default Port No:8000
Default Username:admin
For more, please refer to Security Control Panel
Installation Guide.
For more, please refer to Video Security Control Panel User Manual.
If the system is working properly, the keypad alarm will
be occurred while triggering the zone.
The alarm Indicator are shown below.
LED Keypad:Channel indicator turns flicking red.
LCD Keypad:Keypad screen display alarm
information.
If the system is working properly, the
arming/disarming operation will take effect.
Enter the command above for disarming when the
system is in the arming status.
Quick Start Guide
COPYRIGHT ©2016 Hangzhou Hikvision Digital Technology Co., Ltd.
ALL RIGHTS RESERVED.
Any and all informaon, including, among others, wordings, pictures,
graphs are the properes of Hangzhou Hikvision Digital Technology
Co., Ltd. or its subsidiaries (hereinaer referred to be “Hikvision”).
This user manual (hereinaer referred to be “the Manual”) cannot be
reproduced, changed, translated, or distributed, parally or wholly, by
any means, without the prior wrien permission of Hikvision. Unless
otherwise spulated, Hikvision does not make any warranes,
guarantees or representaons, express or implied, regarding to the
Manual.
About this Manual
This manual is applicable to video security control panel.
The Manual includes instrucons for using and managing the product.
Pictures, charts, images and all other informaon hereinaer are for
descripon and explanaon only. The informaon contained in the
Manual is subject to change, without noce, due to firmware updates
or other reasons. Please find the latest version in the company
website (hp://overseas.hikvision.com/en/).
Please use this user manual under the guidance of professionals.
Trademarks Acknowledgement
and other Hikvision’s trademarks and logos are the
properes of Hikvision in various jurisdicons. Other trademarks and
logos menoned below are the properes of their respecve owners.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE
PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND
FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS, AND
HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY
QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND
NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION,
ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO YOU
FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR
DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS PRODUCT,
EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF
PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL
NOT TAKE ANY RESPONSIBILITES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER
ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET
SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL
RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS
PRODUCT IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE
APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT
THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE
APPLICABLE LAW, THE LATER PREVAILS
Step3 Testing
Arming/Disarming Command: 【User Password】+ #
Buzzer:Rapid beep sound.
Enter the command below to clear the triggered alarm.
【User Password】+【*】+【1】+【#】
Online Device (2)
Add to Client
IP
xx.xx.xx.xx
xx.xx.xx.xx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxx-xx-xx xx:xx:xx
xxxx-xx-xx xx:xx:xx
8000
8000
Inactive
Active
Device Type Firmware Version Server PortSecurity Start Time
Add all Modify Netinfo Reset Password Activate Filter
Refresh Every 60s
Onlie Device (2)
Add to Client
IP
xx.xx.xx.xx
xx.xx.xx.xx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxxxxxxxxxxx
xxxx-xx-xx xx:xx:xx
xxxx-xx-xx xx:xx:xx
8000
8000
Inactive
Active
Device Type Firmware Version Server PortSecurity Start Time
Add All Modify Netinfo Reset Password Activate Filter
Refresh Every 60s
Add Device Modify
Nickname IP
Add
Adding Mode:
Add Offline Device
Nickname:
Address:
Port:
User Name:
Password:
Add Cancel
Export to Group
Set the device name as the group name and add all the
channels connected to the device to the group.
IP/Domain IP Segment IP Server HiDDNS
Funcon Descripon Command
Programming/
Eding Password
Control Panel
Programming
Installer Password
*
0
#
Exit Operaon
*
#
Operator Password
Operator Password
*
0
#
User No. (3digits)#
New Password#
New Password
#
Tesng Tesng Password*60#
Alarm Center Tesng
Password
*
6
1
#
Project Mode
Password
Project
9
0
n
#
Exing Project Mode
Project or *#
Arming/Disarming
Normal(Away)Arming
/Disarming
Password
#
Instant Arming
Password
*
7
#
Stay Arming
Password
*
4
#
Funcon Descripon Command
Clearing Alarm
Clearing Under
arming status
Password
*
1
#
Bypass
Bypass Zone
n
Password
Bypass
n
n
n
#
Password
Bypass
n
n
n
#
Bypassnnn#
nnn
is the zone No.
Keypad Sengs Enabling/Disabling
Keypad Tone
*51#
Enabling/Disabling
Fault Prompt
*56#
LCD Backlight Control
*52nnn#
LCD Backlight
Disabling
*
8
#
Restore Bypass:Enter Command Under
the bypass Status
Normally Used Keypad Operation Command
Siren (Connected):Triggered.
  • Page 1 1
  • Page 2 2

Hikvision DS-19A08-01BN Quick start guide

Type
Quick start guide
This manual is also suitable for

Hikvision DS-19A08-01BNG is an advanced security control panel designed to safeguard your property. With 8 zones and 4 partitions, it offers flexible protection for homes, offices, and small businesses. It supports various wired and wireless detectors, allowing you to customize your security system according to your needs. The built-in tamper protection ensures reliable operation, while the clear LCD display and user-friendly keypad make it easy to operate.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI