SECO-LARM EAP-5D5Q User manual

Type
User manual
®
EAP-3D5Q, EAP-5D5Q
Access Control Power Supply, Five Outputs
Manual
Features:
Input 110~240 VAC, fused at 3.15A
5 Outputs individually fused (PTC, 1.1A), in
both fail-safe and fail-secure modes
DC Output failure supervision relay
Filtered and electronically regulated outputs
Individual LED status indicators for AC input,
DC output, and channel outputs
Adjustable output voltage to compensate for
voltage drop
AC Power failure supervision relay
Over-current fuse-protected AC input
12/24 VDC Outputs, field selectable
Battery failure / low battery supervision relay
Built-in back-up battery charger (Batteries not
included)
Automatically switch to backup battery if AC fails.
Selectable 2.2kΩ End-of-Line (EOL) resistor for AC
failure and battery failure supervision relays via DIP
switch
Auxiliary output relay
Selectable delay timer (5sec, 5min, 5h) for AC failure
supervision relay via DIP switch
Board designed with LED overload indicator and
automatic shutdown for short-circuit protection.
Heavy-duty steel case with removable cover for easy
access to connections
Ventilation holes to prevent heat buildup
Room for two 7Ah batteries (or two 12Ah batteries for
EAP-5D5Q) (Batteries not included)
Knockouts for power connections and optional cam lock
EAP-5D5Q shown
ENFORCER Access Control Power Supply, Five Outputs
2 SECO-LARM U.S.A., Inc.
ON
1 2
Power Supply / Enclos
u
r
e
Screws for the enclosure door
1
x
Cable management clamp
Cable management nut
3
x
Wires for backup battery
1
x
6ft Power cord with
ground wire
Manual
(red, black, white)
Protective plastic bushing for power cable
Model EAP-3D5Q EAP-5D5Q
Operating voltage 110~240 VAC
Output voltage 12/24 VDC (selectable)
Output voltage range
(adjustable)
12VDC 12~13
24VDC 23~25
LED Status indicator
DC Red=12VDC, blue=24VDC for each output
AC Green, input
Current rating 3A@12VDC, 1.5A@24VDC 5A@12VDC, 2.5A@24VDC
Supervision relays EOL: Selectable ON (2.2kΩ) or OFF, 3A@24VDC dry relay output
Power failure supervision relay 3A@24VDC
Auxiliary supervision relay 3A@24VDC
AC Input fuse rating 3.15A
AC Power cord 6ft (1.8m)
Operating humidity 85% maximum
Operating temperature -4°~149° F (-2~65° C)
Dimensions 12
1
/
8
"x12
1
/
4
"x3
9
/
16
" (308x311x90 mm) 14
13
/
16
"x14
5
/
16
"x4
1
/
8
" (377x363x105 mm)
Weight 10-lb 2-oz (4.6kg) 11-lb (5kg)
Specifications:
Overview:
Parts List:
ON
Backup battery
terminal
AC Input LED
status indicator
AC Failure
supervision
relay output
Battery presence / low
battery monitor DIP
switch (default ON)
12/24 VDC
Output selection
slide switch
(default 12VDC)
DC Output voltage
adjustment
potentiometer
+
AC Failure delay
timer DIP switch
(default 5s)
Battery failure / low
battery supervision
relay output
110~240
VAC Input
terminals
End
-
of
-
line (EOL)
2.2kΩ resistor DIP
switch (default ON)
Power
switch
1 2
Vol. Out.
OFF
24V
12V
ON
1 2
LB Mode
Both
ON
Bpth
OFF
PRESENT
FAIL
AC FAIL Time
S1
S2
5s
ON
ON
5m
ON
OFF
5H
OFF
OFF
DC Output LED
status indicator*
red=12V, blue=24V
S1
S2
ON
OR
OFF
2.2K
12/24 VDC
fail-safe and
fail-secure
fused outputs
DC power fail
supervision
relay
Auxiliary
output relay
DC voltage
input
from access
control station or
emergency switch
N.O. or N.C. input
from access
control station or
emergency switch
Installation:
EAP-5D5Q shown
*
Built
-
in output overload
/ short
-
circuit
protection
If an overload occurs, the motherboard's
output
voltage output will drop. The
voltage drop will depend on the extent of the overload. The greater the overload the greater the voltage drop. If the overload is
extensive, the voltage output will become intermittent and the red LED will start flashing. When the overload is removed, the
motherboard will automatically restart normal output. If an output short-circuit occurs, the motherboard will automatically shut the
output down and the red LED will turn off. When the short-circuit is removed, the motherboard will automatically come back on line.
IMPORTANT:
The ENFORCER Power Supply is not waterproof or weatherproof. Therefore, it must be mounted indoors where it
will not be exposed to rain or other moisture.
Installation must be done by qualified personnel, and should conform to local and all other applicable codes.
1. Choose a mounting location out of sight and protected from moisture and weather, but easily accessible for future servicing.
NOTE: Make sure the space where the enclosure is to be mounted has adequate ventilation. Otherwise, heat buildup inside
the
enclosure could damage the electronic parts.
2. Locate the enclosure mounting holes. Using these holes as a template, mark the location of the 4 screws on the wall with a
pencil.
3. Thread the AC power cord through the protective plastic power cord bushing and then through the power cord hole in the
enclosure, snapping the bushing into place. Secure the power cord with the cable management clamp.
ENFORCER Access Control Power Supply, Five Outputs
SECO-LARM U.S.A., Inc. 3
Installation
(Continued)
:
4.
Attach to the wall by first screwing in two
3
/
16
" x 1" (4x26 mm) upper screws
using plastic wall anchors if needed (both not included) until the gap between
the wall and the screw head is approximately
1
/
4
" (6mm).
5. Hang the enclosure on the two upper screws using the enclosure's upper
screw holes and adjust the proper location of the enclosure. Screw in the two
lower screws. Then securely fasten the upper and lower screws.
6. Run wires from the access control devices to the power supply. The
enclosure has knock-outs on the side, top, bottom, and rear panels for
running cables. Punch out the appropriate knock-outs.
7. Set the desired DC output voltage (12 or 24 VDC) of the power supply using
the sliding switch (see "Overview," pg. 3). The default is 12VDC.
8. Connect the backup battery to the backup battery terminal (see Fig. 1).
Check voltage output reading of the power distribution module (PDM). If the
green LED is ON, and the voltage reading of the PDM's five channel outputs
are the same as the backup battery terminal's voltage reading, this indicates
that the power supply is working properly. Disconnect battery after testing.
9. Connect the power input wires of the access control devices or accessories
to the power distribution module (PDM, see "Overview," pg. 2). Observe
correct polarity. For fail-secure devices, connect positive to terminals
marked "POS. OPEN LOOP" and negative to terminals marked "NEG." For
fail-safe devices, connect positive to terminals marked "POS. CLOSE LOOP"
and negative to terminals marked "NEG".
IMPORTANT NOTES/WARNINGS:
a. To avoid risk of electrical shock, the ground terminal of the "AC
INPUT" MUST be connected to earth via the power cord.
b. If the "Trigger" terminal block function is to be used, a 2.2kΩ resistor
must always be connected to the "Trigger" terminal block as in Fig. 2.
c. Maximum total current connected to the power supply terminal must not
exceed the power supply's total current capacity (5A@12VDC and
2.5A@24VDC).
d. Check the output voltage reading of the power supply as stated above
and double check the specified operating voltage of each device before
connecting it to the power supply to avoid potential damage.
e. Use at least 18-gauge wires to minimize voltage drop. The thinner the
wire, the greater the voltage drop.
f. Keep power limited wiring separated from non-power limited wiring (AC
input, battery wiring) by a minimum distance of
1
/
4
" (7mm) and use
separate knockouts in the enclosure.
10. Connect a visual or audio indicator (such as siren or strobe light) to the AC-
failure and battery-failure / low battery supervision relays if needed (see
"Overview, pg. 2). Use between 22AWG to 18AWG wire size.
11. Follow the connection diagrams shown in Fig. 3~8 to trigger the PDM from a
wet and/or dry contact switch from the control station.
12. Connect a visual or audio indicator (such as siren or strobe light) to the
power fail supervision relay and Auxiliary output relay if needed.
13. Double check to ensure everything is connected properly. Connect the AC
power (110~240 VAC). The AC LED & DC LED on the main board
(red=12VDC, blue+24VDC), and the power LED on the PDM should turn ON
to indicate the power supply unit is working properly.
14. Reconnect the backup battery. Again ensure the voltage output reading of
the PDM is within the normal working range. Check the DC output voltage
reading at the end of the wire pairs where it is to be connected to the device.
If the output voltage reading falls below the minimum voltage requirement of
the device, use a small screwdriver to carefully turn the potentiometer
marked "VR1" located on the PCB. Turn clockwise to increase the voltage
and counterclockwise to decrease the voltage (see "Overview," pg. 2).
Fig. 1
12VDC
24VDC
+
12VDC
Battery
+
12VDC
Battery
+
12VDC
Battery
2.
2kΩ (EOL)
resistor
Fig. 2
Fig. 3
DC input from
control station
2
.
2kΩ (EOL)
resistor
N.C.
switch
Momentary trigger for wet and/or
dry N.C. switch
Fig. 4
2.
2kΩ (EOL) resistor
N.O.
switch
DC input from
control station
Momentary trigger for wet
and/or
dry N.O. switch
Fig. 5
Latch trigger for wet and/or dry
N.C. switch
N.O. switch for
RESET
N.C. switch from
control panel
2.
2kΩ
(EOL)
resistor
Fig. 6
Latch trigger for wet and/or dry
N.O. switch
N.C. switch for
RESET
N.O. switch
from control
panel
2.
2kΩ (EOL)
resistor
ENFORCER Access Control Power Supply, Five Outputs
4 SECO-LARM U.S.A., Inc.
Installation (Continued)
:
IMPORTANT NOTE
S
:
a. Do not adjust the potentiometer unless absolutely necessary. Adjusting the potentiometer alters default factory settings.
b. The potentiometer adjusts the voltage of all output wire pairs. Check each device carefully. An output voltage in excess of
the specified voltage level of the device may cause damage.
15. Once the desired DC output voltage is achieved, connect the wire pairs to the device.
Programmable Features
a. AC-failure Relay Output Delay Timer — Program the AC-failure relay delay timer at 5sec, 5min or 5h using the DIP switch
(see "Overview," pg. 2). The default setting is at 5sec.
b. 2.2kΩ End-of-Line (EOL) Resistor — The end-of-line 2.2kΩ resistor for AC-failure relay and battery-failure / low battery
supervision relays (3A@24VDC) can be activated independently using the DIP switch (see "Overview," pg. 2, default ON).
c. Battery Presence and Low Battery Monitor
When the LB MODE DIP switches are in the ON position, the power supply will
monitor the battery to verify if it has sufficient voltage to run the power supply in case of AC power failure. Selecting "OFF"
will stop monitoring of battery status and will charge battery continuously. It can take up to 5 minutes to alert you of a battery
failure. The length of time the system will run will be limited by the overall capacity and the age of the batteries and the
amount of load being drawn off the power supply.
16. Connect the backup battery to the backup battery terminal (see Fig. 2 and "Overview," pg. 2, default ON).
17. Close the enclosure door and secure it with either the provided machine screws or an optional cam lock.
SECO-LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Website:
www.seco
-
larm.com
Phone:
(949) 261
-
2999 | (800) 662
-
0800
Email: sales@seco
-
larm.com
PITSW1
Order Part# 764
-
034
-
4
%
MI_EAP
-
xD5QUS_210303.docx
NOTICE:
The SECO
-
LARM policy is one of continual development and improvement. For that reason, SECO
-
LARM reserves the right to change
specifications without notice. SECO-LARM is also not responsible for misprints. All trademarks are the property of SECO-LARM U.S.A.,
Inc. or their
respective owners. Copyright © 2021 SECO-LARM U.S.A., Inc. All rights reserved.
WARRANTY:
This SECO
-
LARM product is warranted against defects in material and workmanship while used in normal service for
one
(
1
)
year from
the date of sale to the original customer. SECO-LARM’s obligation is limited
to the repair or replacement of any defective part if the unit is returned,
transportation prepaid, to SECO-
LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical or electrical misuse or abuse,
neglect, repair or alteration, improper or abnormal usage, or faulty installation, or if for any other reason SECO-
LARM determines that such equipment is
not operating properly as a result of causes other than defects in material and workmanship. The sole obligation of SECO-LARM and
the purchaser’s
exclusive remedy, shall be limited to the replacement or repair only, at SECO-LARM’s option. In no event shall SECO-
LARM be liable for any special,
collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone else.
Fig. 7
Multiple PDM momentary trigger for wet and/or
dry N.O. switch
A
dditional
PDM if needed
2.
2kΩ
(EOL)
resistor
2.
2kΩ (EOL)
resistor
VDC input from
control station
N.O.
switch
Fig. 8
Multiple PDM momentary trigger for wet and/or
dry N.O. switch
A
dditional
PDM if needed
2.
2kΩ
(EOL)
resistor
2.
2kΩ (EOL)
resistor
VDC input from
control station
N.C.
switch
Table 1: Terminal Functions
Main Board Power Distribution Module (PDM)
Legend Functions Legend Functions
A E N To connect 110~240 VAC power ("A" for active
wire, "E" for earth or ground wire, and "N" for
neutral wire
TRIGGER Used to connect NO or NC input trigger signal (2.2k EOL resistor)
from access control panel. A short or open circuit will transfer
power from "POS CLOSE LOOP" to "POS OPEN LOOP."
BAT.
FAIL
Used to notify battery failure. Dry contact relay
rated at 3A@24VDC. If backup battery is not
connected properly or if voltage output falls
below 11.2VDC for 12VDC setting (or 22.7VDC
for 24VDC setting, the connected warning device
will be activated.
VOL.
TRIGGER
Used to connect wet (5~30 VDC) input trigger signal from access
control panel. A short circuit or open circuit will transfer power from
"POS CLOSE LOOP" to "POS OPEN LOOP."
POWER FAIL Used to notify loss of DC power. Driy contact relay rated
3A@24VDC. If VDC input to the PDM is interrupted, the connected
warning device will be activated.
– BAT +
Used to charge the backup battery. Maximum
charging current is 5A
AUX OUTPUT
Used to activate other auxiliary device when trigger signal is
received from the "TRIGGER" or "VOL TRIGGER" terminals
– DC + 12 or 24 VDC Output terminal from main board – DC INPUT +
12 or 24 VDC Input from main board
California Proposition 65 Warning
:
These products may contain chemicals which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

SECO-LARM EAP-5D5Q User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI