CONTENTS OF THE KIT
General precautions
Read the instructions carefully before beginning the installation and carry out the procedures as specifi ed by the manufacturer.
The product must be installed, programmed, commissioned and serviced by qualifi ed technicians, correctly trained with regard to
respecting the regulations in force, including implementing accident-prevention measures.
Before carrying out any cleaning or maintenance operation, disconnect the power supply.
The equipment must only be used for the purpose for which it was designed.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
+
AL
B
M1
CL.RES
M/S
CL.RES
XDV/304
CL.RES CL.RES
M/S MASTER SLAVEM/S
Page 3 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
AGT V
Description
Internal video receiver.
Function of terminals and jumpers
Terminal board M1
BBUS-line input
+Landing call
AL Alarm input
Closing resistance (CL.RES)
Master/slave selector (M/S)
Technical data
Type AGT V
Power supply from BUS line (VDC) 15 to 20
Maximum consumption (mA) 175
Consumption in stand-by mode (mA) <1
Single LED consumption (mA) 1
Operating temperature (°C)
+5 to +40
IP Rating IP 30
Video standard PAL/NTSC
LCD TFT display (inches) 5
1
2
Page 4 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Installation
Unhook the device from the metal support by press-
ing the plastic tab and sliding the device smoothly o
the support .
Fix the wall support to the round Ø 60 mm recessed
box , to the rectangular box 503 , or to the
Ophera (PHI) recessed box , with the “TOP” arrow
pointing upwards.
Avoid overtightening the screws.
Use screws and plugs to make the support more
stable.
The box must be installed at a suitable height for the
user.
Once the connections have been made, attach the
video terminal to the metal support .
To unfasten the unit from the metal support, press the
plastic tab and lift the terminal .
N° Slave
Lb
La
Lc
XDV/304
VAS/101
N° Master
MT M
Page 5 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VCM/1D UTP CAT5
No. Master 3211
No. Slave 0373
VCM/1D VCM/2D UTP/CAT 5 2x1mm22 x 2.5 mm2
La+Lb ≤100 m ≤100 m
Lc ≤25 m ≤60 m
La+Lb+Lc ≤100 m
System limits
4 monitors can be switched on simultaneously only in one- or two- family systems with entry panel X1+VA/01.
3sec
... beep!
Page 6 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Configuring melodies
Perform each of the following programming steps, in suc-
cession:
1-Enter programming mode.
Press and hold the button for 3 seconds. A short buzzing
sound and a red fl ashing LED confi rm that you have entered pro-
gramming mode .
2-Programming the melody associated with the call from
the entry panel.
To listen to the melodies in sequence, press .
To select the melody and exit the programming mode, press
.
To select the melody and continue programming, press .
3- Programming the melody associated with a call from the
landing.
To listen to the melodies in sequence, press .
To select the melody and exit the programming mode, press key
.
To select the melody and continue with programming, press button
.
4-Programming the number of rings per call.
Press as many times as the number of rings you want (from
1 to 12 rings) .
Three seconds after the key was last pressed, the selected call is
played back with the chosen number of rings.
To exit programming mode, press .
To program a call, please see the entry panel manual.
MTMV/01
Page 7 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Description
Communication unit for X1 systems.
- MTMV/01 Video module X1
Description of parts, front view
Speaker.
Yellow LED - Conversation in progress.
Green LED - Door open.
Mini USB port for programming from PC.
Microphone.
Button not enabled.
PROG button for manual programming.
Settings:
Speaker volume control
Microphone volume control
Electric lock opening time control (1-10 seconds, default set-
ting: 1 second)
Blue LED - System busy.
Red LED - Call in progress.
Video camera lens.
Light.
Description of parts, rear view
Terminal board housing.
Socket for the unit for the hard-of-hearing.
Additional unit socket.
Terminal board cover.
For more information on the button and LED func-
tions, please see the programming instructions.
Function of terminals
MTMV/01 terminal board Audio/video module X1
16-18 V DC power supply
Busbar
12 V - 1 A max electric lock
Earth
Door lock release button (NO)
Door contact input (NO)*
Entry panel enabling output*
(to earth)
Auxiliary contact max. 1A, 30V (AUX 2)*
* Factory settings. The contact can be programmed to
perform diff erent functions.
Technical data
Type MTMV/01
Video standard PAL/NTSC
Video camera resolution (pixels) 680x512
Minimum lighting (LUX) 1
Maximum absorption (mA) 250
Consumption in stand-by mode (mA) 70
Power supply (V DC)* 16 to 18
Storage temperature (°C) -25 to +70
Operating temperature (°C) -25 to +55
Protection rating (IP) 54
* Use BPT/CAME power supply units that are electronically pro-
tected with maximum output current of 2.5 A.
1
3
5
7
21
421
632 1
12 1
843 2
Page 8 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
REMOTE CONTROLLING CALL BUTTONS
Manual configuration of terminals and as call inputs 1 and 2
Short circuit the terminals ( and ), press and hold the two call buttons on the unit, and power the device. The unit will restart.
This indicates that the procedure has been completed successfully.
Remove the short circuit and connect the additional N.O. buttons to the terminals and .
BUTTON NUMBERING
G
PROG
>3’
>3’
<6’
<6’
aa
a
a
a
Page 9 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
PROGRAMMING
Programming for the first time
Entering programming mode
Press and hold the PROG button on the entry panel for at least
3 seconds and release within 6 seconds.
The LEDs and and the button LEDs fl ash to show the
buttons are being programmed .
a
a
b
b
a
a
Page 10 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming buttons
Press the fi rst call button on each module or . The mod-
ule stops fl ashing and remains on. Repeat for all the other call
devices.
NOTE. For the basic module (no call buttons)
a
a, you do
not need to press the buttons that are shown as fl ashing in
gure
a
a.
Once programming is complete, you are automatically taken to
“programming calls”.
Programming calls
The LED ashes. Lift the internal receiver handset (if present)
and press the door lock release and AUX2 buttons . On
the entry panel, press the call button to be linked to the internal
receiver
a
a. A beep confi rms that the setting has been stored
b
b. End the call and repeat programming for all of the other
internal receivers.
>3’
PROG
<1
<1’’
a
a
b
b
c
c
Page 11 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming the open-gate function
An operator control can be connected to the module auxiliary
relay and/or an operator status to the door status input.
From applicable, preconfi gured internal receivers, the relay can
be controlled using the open-gate command and/or the operator
status shown via the relevant LED on the internal receiver itself.
To confi gure the module with the open-gate function, enable the
function on one of the connected internal receivers, by entering
call programming (see previous paragraph), and send an open-
gate command from the internal receiver (press and hold the
“key” button) as an alternative to or in addition to associating
the call button. The open-gate LED lights up on this internal re-
ceiver to indicate that the function has also been enabled on
the module.
NOTE. If the module is programmed with the open-gate function,
the “door contact input” terminal will function exclusively as an
operator status indicator.
NOTE. This function is available from version 1.03.000 of the
module software.
NOTE. You can force the switch from one programming mode to
another by pressing the PROG button on the module unit for 3
seconds and releasing within 6 seconds. If you force the switch
to call programming from button programming, the button units
which have not been programmed will be confi gured to 8 calls.
If the basic module is not programmed, calls are not confi gured.
Exiting programming
Press the PROG button briefl y . The LEDs on the entry panel
switch o .
Adjusting the brightness and colour of the module
backlight
During call programming , you can adjust the brightness
and colour of the module backlight. Press the left call button to
select white , and the right call button to select blue .
Press the same button repeatedly to select one of the fi ve bright-
ness levels (o , 25%, 50%, 75%, 100%).
3
8
4
6
9
7
5
2
1
100 °
82 °
54 °
72 °
1÷9
0
a
a
b
b
Page 12 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming the entry panel video camera
While programming the calls, the video camera’s fi eld of view can be adjusted from any
receiver. To do this, lift the handset (where present) and press the “auto-connection
button . From the default confi guration, scroll through the subsequent confi gurations
pressing the AUX1 button or go back to the previous confi gurations by pressing
the AUX2 button . Settings are saved automatically.
Adjusting the brightness level of the light on the entry panel
While programming calls
a
a, the brightness level of the entry panel light can be adjusted from any receiver.
Press the “auto-connection ” button on the internal receiver
b
b to activate the video camera on the entry
panel for which you want to adjust the brightness level. Use a previously assigned call button to increase/
decrease brightness of the light .
Reprogramming
When reprogramming a system which has already been programmed, you are taken directly to call programming. To access button
reprogramming, follow the process for forcing the mode switch described above.
If you add, replace or remove an entry panel, you must follow the “programming buttons” procedure so that the system recognises the
changes.
Programming an intercommunicating group
NOTE: Leave the function disabled if the entry panel is connected to a VA/01, A/01 or VSE/301.01.
Before programming an intercommunicating group, enable the intercommunicating function. This function is disabled by default.
PROG
PROG
<1
<1’’
PROG
>20’
>20’PROG
>8’
>8’
<11
<11’’
Page 13 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
To enable the intercommunicating function, press the intercommunicating call button you want to call with on the internal receiver you
want to program . A beep indicates that the function has been programmed successfully. Repeat for all of the other internal receiv-
ers to be included in the intercommunicating group. To conclude programming, press the PROG button on the entry panel briefl y .
NOTE. Once an internal receiver has been included in a group by assigning the intercommunicating call button, it cannot be
excluded from this group. If you want to change the call button on an internal receiver which has already been programmed
as an intercommunicating receiver, or you want to add new internal receivers to the group, repeat the operations detailed
under “Programming an intercommunicating group”.
Enabling/disabling
Press the PROG button on the entry panel and hold for at least 20 seconds .
The red and yellow LEDs fl ash quickly for 3 seconds .
NOTE: If the intercommunicating function is disabled, follow this procedure to enable it, and vice versa.
The yellow LED comes on for 2 seconds to show the function has been enabled, or the red LED comes on for 2 seconds to show
the function has been disabled.
NOTE. Program the intercommunicating group after assigning calls to all indoor receivers.
Programming an intercommunicating group
Press and hold the PROG button on the entry panel for at least 8 seconds and release within 11 seconds .
The red and yellow LEDs fl ash to show intercom programming is in progress .
RESTORING FACTORY SETTINGS
To restore the entry panel to the default settings (including the terminal functions , ), remove the power supply, press and hold
the two call buttons on the unit and power the device.
After 5 seconds the entry panel restarts.
NOTE: if the entry panel does not restart, it has not been restored to factory settings.
M2M1
+
43,5
45
7,5 57
70
106
64,5
145
Page 14 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VAS/101
Installation
The power supply must always be installed horizontally.
The device can be installed on DIN rails (EN 50022) on a suit-
able switchboard.
See fi gure for dimensions.
NOTE. Ensure there is correct ventilation if the power supply is
installed in a metal case.
Terminal board M1
~Network
~
Terminal board M2
+Power supply output 18 V DC (*)
(*) The device is electronically protected against
overloads and short circuits.
Technical data
T
yp
e VAS-101
Power supply (V AC) 230
Max. absorbed current (mA AC) 200
Maximum power dissipation (W) 10
Output voltage (V DC) 18
Continuous output current (A) 0.5
Intermittent output current with cycle
1A/0.5A 1'/3'(A) 1
DIN EN50022 modules 35x7.5 (no.) 4
Storage temperature (°C) -25 + 70
Operating temperature (°C) 0 + 35
Protection rating (IP) 30
Page 15 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
This product complies with current applicable reference standards.
DISPOSAL - Dispose of the packaging and the device at the end of its life cycle responsibly, in compliance with the laws in force in
the country in which the product is used. The recyclable components are marked with a symbol and the material ID marker.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE. THE MEASUREMENTS,
UNLESS OTHERWISE STATED, ARE IN MILLIMETRES.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FA01481-EN - 09/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME AGT Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI