CAME AGTLVKIT is a video intercom system designed for use in residential buildings. The kit includes an internal video receiver (AGT V), a power supply (VAS/101), and a wall-mounted entry panel (LVC/01). The system allows users to communicate with visitors at the door, grant access to the building, and view live video footage from the entry panel.

The AGT V internal video receiver has a 5-inch LCD TFT display and can be used to answer calls from the entry panel, view live video, and control the door lock. The VAS/101 power supply provides power to the system, while the LVC/01 entry panel is equipped with a video camera, microphone, and speaker, allowing for two-way communication with visitors.

CAME AGTLVKIT is a video intercom system designed for use in residential buildings. The kit includes an internal video receiver (AGT V), a power supply (VAS/101), and a wall-mounted entry panel (LVC/01). The system allows users to communicate with visitors at the door, grant access to the building, and view live video footage from the entry panel.

The AGT V internal video receiver has a 5-inch LCD TFT display and can be used to answer calls from the entry panel, view live video, and control the door lock. The VAS/101 power supply provides power to the system, while the LVC/01 entry panel is equipped with a video camera, microphone, and speaker, allowing for two-way communication with visitors.

AGTLVKIT
AGT V
M2M1
+
VAS/101
LITHOS
EN
E
ngl
i
sh
FA01429-EN
INSTALLATION MANUAL
KIT AGT V + LITHOS
AGT V
M2M1
+
VAS/101
LITHOS
Page 2 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
CONTENTS OF THE KIT
General precautions
Read the instructions carefully before beginning the installation and carry out the procedures as specifi ed by the manufacturer.
The product must be installed, programmed, commissioned and serviced by qualifi ed technicians, correctly trained with regard to
respecting the regulations in force, including implementing accident-prevention measures.
Before carrying out any cleaning or maintenance operation, disconnect the power supply.
The equipment must only be used for the purpose for which it was designed.
The manufacturer declines all liability for any damage as a result of improper, incorrect or unreasonable use.
+
AL
B
M1
CL.RES
M/S
CL.RES
XDV/304
CL.RES CL.RES
M/S MASTER SLAVEM/S
Fam. Rossi
Page 3 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
AGT V
Description
Internal video receiver.
Function of terminals and jumpers
Terminal board M1
BBUS-line input
+
Landing call
AL Alarm input
Closing resistance (CL.RES)
Master/slave selector (M/S)
Technical data
Type AGT V
Power supply from BUS line (VDC) 15 to 20
Maximum consumption (mA) 175
Consumption in stand-by mode (mA) <1
Single LED consumption (mA) 1
Operating temperature (°C)
+5 to +40
IP Rating IP 30
Video standard PAL/NTSC
LCD TFT display (inches) 5
1
2
Page 4 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Installation
Unhook the device from the metal support by press-
ing the plastic tab and sliding the device smoothly o
the support .
Fix the wall support to the round Ø 60 mm recessed
box , to the rectangular box 503 , or to the
Ophera (PHI) recessed box , with the “TOP” arrow
pointing upwards.
Avoid overtightening the screws.
Use screws and anchors to make the support more
stable.
The box must be installed at a suitable height for the
user.
Once the connections have been made, attach the
video terminal to the metal support .
To unfasten the unit from the metal support, press the
plastic tab and lift the terminal .
Lb
La
VA/01
XDV/304
L1 L2 L3
MT M MT M MT M
N° Slave
N° Master
N° Slave
Lb
La
Lc
Lithos
XDV/304
VAS/101
N° Master
Page 5 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VCM/1D VCM/2D UTP/CAT 5 2 x 2.5
mm2
La+Lb ≤100 m ≤60 m
L1, L2, L3 ≤100 m
L1+L2+ L3 ≤300 m
La + Lb + L1(L2, L3) ≤150 m
La + Lb + L1 + L2 + L3 ≤600 m
VCM/1D UTP CAT5
No. Master 4321321
No. Slave 4567067
VCM/1D UTP CAT5
No. Master 3211
No. Slave 0373
VCM/1D VCM/2D UTP/CAT 5 2x1mm22 x 2.5 mm2
La+Lb ≤100 m ≤100 m
Lc ≤25 m ≤60 m
La+Lb+Lc ≤100 m
System limits
4 monitors can be switched on simultaneously only in one- or two- family systems with entry panel X1+VA/01.
3sec
... beep!
Page 6 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Configuring melodies
Perform each of the following programming-steps, in suc-
cession:
1-Enter programming mode.
Press and hold the button for 3 seconds. A short buzzing
sound and a red fl ashing LED confi rm that you have entered pro-
gramming mode .
2-Programming the melody associated with the call from
the entry panel.
To listen to the melodies in sequence, press .
To select the melody and exit the programming mode, press
.
To select the melody and continue programming, press .
3- Programming the melody associated with a call from the
landing.
To listen to the melodies in sequence, press .
To select the melody and exit the programming mode, press
.
To select the melody and continue programming, press .
4-Programming the number of rings per call.
Press as many times as the number of rings you want (from
1 to 12 rings) .
Three seconds after the key was last pressed, the selected call is
played back with the chosen number of rings.
To exit programming mode, press .
To program a call, please see the entry panel manuals.
43,5
45
7,5 57
70
106
A
M2M1
+
Page 7 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
VAS/101
Technical data
T
yp
e VAS-101
Power supply 230 VAC 50-60 Hz
Max. absorbed current
(mA AC)
200
Dissipated power 10 W max
Rated power 18 VDC 1 A-0.5 A 1’/3’
Size 4 DIN
Storage temperature -25°C + 70°C
Operating temperature 0°C +35°C
IP rating IP 30
Installation
The power supply must always be installed horizontally.
The device can be installed on DIN rails (EN 50022) on a suit-
able switchboard.
See fi gure for dimensions.
NOTE. Ensure there is correct ventilation if the power supply is
installed in a metal case.
Terminal board M1
~Network
~
Terminal board M2
+Power supply 18 V DC (*)
(*) The device is electronically protected against
overloads and short circuits.
500 mm
1080 mm
77°
94°
800 mm
500 mm
163,5 mm
43,5 mm
1550 - 1600 mm
Page 8 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
LVC/01
Wall-mounted installation
Use a hex key to unscrew the screws in the front plate and re-
move it (fi gure ).
Fix the plugs provided and screw in the entry panel (fi gure )
at the desired height, bearing in mind the position of the video
camera lens (fi gure ).
Thread the pipe with the system conductors as shown in fi gure
.
Pull out the plastic terminal cover and make the connections
(fi gure ).
Once the connections have been made, reinsert the terminal
covers.
For information on fi tting accessories, please see the “Button
modules assembly” section.
Program and adjust the entry panel as described in the “Pro-
gramming” section. Fit the front plate (fi gure ).
Recessed installation
First thread the pipe with the system conductors through one of
the break points (fi gure , point ). Then wall in the recessed
box at the desired height, bearing in mind the position of the
video camera lens (fi gure ). When installing the recessed box,
avoid any deformations by using the spacer provided (fi gure ,
point .
Use a hex key to unscrew the screws in the entry-panel front
plate and remove it (fi gure ).
Thread the connection cables through the hole (fi gure ) and
A
B
DPS LTP
LSI LCI
Page 9 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
x the entry panel to the frame as shown in fi gure . Pull out
the plastic terminal cover and make the connections (fi gure ).
Once the connections have been made, reinsert the terminal
covers.
For information on fi tting accessories, please see the “Button
modules assembly” section.
Program and adjust the entry panel as described in the “Pro-
gramming” section.
Fit the front plate (fi gure ).
Accessories
- Single button DPS ,
- Wall cover LTP ,
- Recessed box LSI ,
- Recessed frame LCI .
1
2
M1
BOUT
M2
SW3
PROG
PROG
M2M1
+
9/6
B
B
NO
C
+
Page 10 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Assembling the modules
Insert the button module as shown in fi gure , making sure it is
the right way up (fi gure ).
Remove the glass and write the names of the users as shown
in fi gure , paying particular attention to which way round the
glass is inserted (fi gure ).
Name cards: Size
53x13x0.3 mm
53x33x0.3 mm
Function of terminals
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3
>3’’
<6’
<6’
M1
BOUT
SW3
PROG RESET
PROG
M2
ROG P
PROG
Page 11 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Terminal board M1
BOUT Busbar
+
16-18 VDC power supply
Terminal board M2
Earth
Door release button (NA)
Electric lock
12 V 1 A max
Technical data
T
yp
e LVC/01
Entry panel
Power supply 16-18 VDC
Power draw 250 mA (100 mA stand-by)
Size 99x207x30 mm
Storage temperature -25°C +70°C
Operating temperature -15°C +50°C
IP Rating IP 54
Video camera
Video standard PAL/NTSC
Resolution 680x512 pixels
Minimum lighting 1 LUX
LED functions and adjustment
speaker audio
microphone audio
solenoid lock 1-10 s. (default 1 s)
LED symbols
O
On
Slow fl ash
Quick fl ash
Programming
Programming for the fi rst time
Entering programming mode. Press and hold the PROG key
for at least 3 s, then release it (within 6 seconds) as soon as
the PROG LED lights up and the button backlighting fl ashes as
illustrated in fi gure .
If the PROG LED does not light up, there has been a malfunction.
Check the connections and return to programming mode.
M1
PROG
M1
PROG
M1
BOUT SW3
PROG RESET
PROG
beep
beep
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1
<1’’
Page 12 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Programming the call keys. Lift the receiver handset that
you want to program (where present), then press the door lock
release button and AUX2 button .
On the entry panel, press the call key to be associated with the
receiver . A beep will confi rm that the setting has been stored.
Reposition the handset where applicable and repeat the same
operations for all the other receivers.
Programming type of keys. Press and hold the fi rst key on the
entry panel in the position shown /A until the LED back-
lighting stops fl ashing and remains on .
Exiting programming.
Briefl y press the PROG key . The PROG LED will switch o .
NOTE. If no action is performed, the procedure will end automat-
ically after 30 minutes.
M1 M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
>3
>3’’
<6’
<6’
M1
BOUT SW3
PROG RESET
PROG
M2
ROG P
PROG
beep
beep
Page 13 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Reprogramming procedure
Entering programming mode. Press and hold the PROG key
for at least 3 s, then release it (within 6 seconds) as soon as the
PROG LED ashes and the button backlighting lights up as
illustrated in fi gure .
If the PROG LED does not light up, there has been a malfunction.
Check the connections and return to programming mode.
Programming the call keys. Lift the receiver handset that you
want to program (where present) , then press the door lock
release button and AUX2 button .
On the entry panel, press the call key to be associated with the
receiver . A beep will confi rm that the setting has been stored.
Reposition the handset where applicable and repeat the same
operations for all the other receivers.
M1
BOUT
M2
SW3
PROG RESET
PROG
M2
SW3
PROG
PROG
<1
<1’’
>3
>3’’
<6’
<6’
M1
BOUT
SW3
PROG RESET
PROG
M2
ROG
PROG
M1
BOUT SW3
PROG RESET
PROG
M2
ROG P
PROG
M1
BOUT
PROG
M1
BOUT
PROG
Page 14 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Exiting programming. Press the PROG key briefl y . The
PROG LED will switch o .
NOTE. If no action is performed, the procedure will end automat-
ically after 30 minutes.
Programming type of keys. When “Programming call keys”,
press and hold the PROG key for at least 3 seconds, then
release it (within 6 seconds) as soon as the PROG LED lights up
and the key backlighting fl ashes as shown in fi gure , entering
the “Programming type of keys” procedure.
Press and hold the fi rst key on the entry panel in the position
shown until the LED backlighting stops fl ashing and remains
on .
To exit programming once complete, press the PROG key briefl y
. The PROG LED will switch o .
If no action is performed, the procedure will end automatically
after 30 minutes.
Page 15 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. -The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
This product complies with current applicable reference standards.
DISPOSAL - Dispose of the packaging and the device at the end of its life cycle responsibly, in compliance with the laws in force in
the country in which the product is used. The recyclable components are marked with a symbol and the material ID marker.
THE DATA AND INFORMATION IN THIS MANUAL MAY BE CHANGED AT ANY TIME AND WITHOUT NOTICE. THE MEASUREMENTS,
UNLESS OTHERWISE STATED, ARE IN MILLIMETRES.
CAME S.p.A.
Via Martiri Della Libertà, 15
31030 Dosson di Casier - Treviso - Italy
tel. (+39) 0422 4940 - fax. (+39) 0422 4941
Page 16 - Manual FA01429-EN - 07/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

CAME AGT Installation guide

Type
Installation guide
This manual is also suitable for

CAME AGTLVKIT is a video intercom system designed for use in residential buildings. The kit includes an internal video receiver (AGT V), a power supply (VAS/101), and a wall-mounted entry panel (LVC/01). The system allows users to communicate with visitors at the door, grant access to the building, and view live video footage from the entry panel.

The AGT V internal video receiver has a 5-inch LCD TFT display and can be used to answer calls from the entry panel, view live video, and control the door lock. The VAS/101 power supply provides power to the system, while the LVC/01 entry panel is equipped with a video camera, microphone, and speaker, allowing for two-way communication with visitors.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI