ADJUST
Press to perform fine-tuning. Check that every access point in the installation is meeting the criteria
established by current regulations. To measure another test point or layer (A: one layer; A+B: two layers; A+B+C: three layers)
press again until finding the test point you are looking for. Each layer has different parameters and therefore,
different measures.
CONFIGURATION
At the DETECTION screen, press and hold
until appears the configuration menu.
1)DET ECT 5V
MAX P OWER RA TE: 41%
POWER RA TE: 40%
)SETUP
OFF
1)CANCEL 2)OPTION 3)SELECT
START AUTO SCAN
EXTERNAL SUPPLY
SOUND CONTROL
BACKLIGHT MODE
CONTRAST LCD
CONFIRM & EXIT
OFF
ON
AUTO
It exits the configuration menu without saving changes
It scrolls along the menu options
It changes the parameter/Accepts
Start Auto Scan: It starts the auto-scan function.
External Supply: It allows selecting the external supply voltage for the antenna among 0V (OFF, by default), 5V, 12V,15V or 24V.
Confirm & Exit:
When using the TVHUNTER +, it may appear on the display some messages and icons, depending on the status or
event is taking place. These messages and icons are detailed below
Low power level battery. Plug it to the charger.
The external supply can be shortcut.
“SUPPLY OVER CURRENT”
“LOW BATTERY”
“VERY LOW BATTERY”
The equipment will be switched off immediately.
MESSAGE
DESCRIPTION
“SUPPLY SHORT CIRCUIT”
The external supply has a high current consumption.
“MANUAL POWER OFF”
The instrument has to be switched off by hand.
“AUTO POWER OFF”
The instrument will switch off after five minutes
of inactivity.
“BATTERY MODE”
When the battery is being charged.
“UPDATE MODE”
When the instrument is being updated.
MESSAGE
DESCRIPTION
“NETWORK NOT FOUND”
The instrument cannot find a TV network.
“SERVICES NOT FOUND”
“SIGNAL NOT DETECTED”
“FULL BATTERY”
“MPEG-2 NOT DETECTED”
“LOADING NETWORK”
“LOADING SERVICES”
“HIGH TEMPERATURE”
The instrument cannot detect the services of a network.
When no signal is detected.
Battery fully charged.
It is not detecting the Transport Stream MPEG-2 signal.
After finding a signal, needs a time to load the network.
After finding a network, needs a time to load services.
The operation temperature is too high.
The instrument must be switched off for a while.
If the problem persists, contact with the technical support.
Find the user’s manual on the download area at: www.promaxelectronics.com
Navegation Keys:
QUICK START GUIDE
(0 DG0103) 01/03/2013
TVHUNTER +
ISDB-T/T
B
1)DET EC T 5V
MAX POW ER RA TE : 41%
POWER R AT E: 4 0%
PRESS
ADJUST
Locked signal (black background)
Test Point Name
TV
FM
3)ADJ US T
OFF
C66 FR:531.
PO WER : 79.5d
B
uV
MER :
35
.0d
B
1.0E- 5CBER:
0
35
1.0E- 8VBER:
TP04:
LM:
Sequential number of
the test point
RF
PRESS
SHORT PRESS: NEXT TEST POINT OR LAYER
LONG PRESS <1s: PREVIOUS TEST POINT OR LAYER
TB
0MHz
>20.2dB
A
It applies and saves the changes made and exits the configuration menu.
v1.04.02