Promax TVHUNTER+ Reference guide

Type
Reference guide
TVHUNTER +
DVB-T/T2
Trademark of the
DVB - Digital Video
Broadcasting Project
Find the user’s manual on the download area at:
www.promaxelectronics.com
TVHUNTER +
DVB-T/T2
PDF
USER MANUAL
DOWNLOAD
SCREEN ICONS REFERENCE
STATUS BAR
DVB-T/T2 signal not locked.
T
T
USB
DVB-T/T2 signal locked.
Power supply connected.
Battery power level.
Manual power off enabled.
Connected to PC through the USB port.
5/12/15/24/OFF
External voltage supplied through the RF connector (5V/12V/15V/24V/OFF)
SWITCHING ON/OFF
Switch on the TVHUNTER + pressing , or for two seconds.
If you press or for more than five seconds when starting, it enables manual power off mode.
FRONT VIEW
T2
T2
QUICK START GUIDE
RF
USB
Input RF connector
Display
DETECTION/CONFIGURATION key
USB connector
Power input connector
IDENTIFICATION key ADJUST key
TVHUNTER +
DVB-T/T2
DETECTION
Plug the TVHUNTER + to the antenna socket and turn the antenna until the TVHUNTER + shows the maximum
power on the display. If necessary, press to switch between 0V (OFF) and the selected external supply voltage.
1)DET E CT 5V
MAX POWER RATE: 41%
POWER RATE: 40%
PRESS
DETECT
Maximum measured power
Current power
External supply voltage
1)DET E CT OFF
MAX POWER RATE: 41%
POWER RATE: 40%
PRESS DETECT TO
SWITCH THE EXTERNAL
SUPPLY VOLTAGE
(see CONFIGURATION)
QUICK START GUIDE
6
NOTE:
.
Once the antenna is aligned using the Detection mode, if it is unknown
the channels that can be received at the location, it is advisable
to "Auto-Scan" and save the results (see Configuration)
TVHUNTER +
DVB-T/T2
IDENTIFICATION
Press and wait until locking the signal. The display will show the parameters of the stored test point (selected name
and frequency), the name of multiplex channel tuned and its services identified at this test point. To change to another
test point press again.
1)DET E CT 5V
MAX POWE R RATE: 41%
POWER RATE: 40%
2)IDENTIFY OFF
LaSexta
CUATRO
C67 FR: 842.0MHz
NET:SFN
SERVICE LIST: 1/8
CNN+
1)DET E CT 5V
MAX POWE R RATE: 41%
POWER RATE: 40%
PRESS
IDENTIFICATION
)
2 IDENTIFY OFF
La 1
La 2
C66 FR: 818.0MHz
NET:RGE CAT
SERVICE LIST: 1/7
24h
Locked signal (black background)
Test Point Name
Tuned channel name
Identified services
TP 04TP 04
Sequential number of
the test point
TP 05TP 05
QUICK START GUIDE
7
PRESS
SHORT PRESS: NEXT TEST POINT
LONG PRESS (1s): PREVIOUS TEST POINT
TVHUNTER +
DVB-T/T2
ADJUST
Press to perform fine-tuning. Check that every access point in the installation is meeting the criteria
established by current regulations. To measure another test point press again until finding the test point you
are looking for.
1)DET ECT 5V
MAX P OWER RA TE: 41%
POWER RA TE: 40%
PRESS
ADJUST
Locked signal (black background)
Test Point Name
3)ADJ UST
OFF
C67 FR:842.00MHz
PO WER : 46.7d BuV
MER :
21
.7 dB
3.9E- 2CBER:
0
33
7.3E- 5VBER:
TP05
LM: 5.6dB
Sequential number of
the test point
RF
CONFIGURATION
At the DETECTION screen, press and hold
until appears the configuration menu.
1)DET ECT 5V
MAX P OWER RA TE: 41%
POWER RA TE: 40%
)SETUP
OFF
1)CANCEL 2)OPTION 3)SELECT
START AUTO SCAN
EXTERNAL SUPPLY
SOUND CONTROL
BACKLIGHT MODE
CONTRAST LCD
CONFIRM & EXIT
OFF
ON
AUTO
It exits the configuration menu without saving changes
It scrolls along the menu options
It changes the parameter/Accepts
Start Auto Scan: It starts the auto-scan function.
External Supply: Select the external supply voltage for the antenna among 0V (OFF), 5V, 12V,15V or 24V.
Confirm & Exit: It applies and saves the changes made and exits the configuration menu.
When using the TVHUNTER +, it may appear on the display some messages and icons, depending on the status or
event is taking place. These messages and icons are detailed below
Low power level battery. Plug it to the charger.
The external supply can be shortcut.
“SUPPLY OVER CURRENT”
“LOW BATTERY”
“VERY LOW BATTERY”
The equipment will be switched off immediately.
MESSAGE
DESCRIPTION
“SUPPLY SHORT CIRCUIT”
The external supply has a high current consumption.
“MANUAL POWER OFF”
The instrument has to be switched off by hand.
“AUTO POWER OFF”
The instrument will switch off after five minutes
of inactivity.
“SERVICE MODE”
Service mode.
“BATTERY MODE”
When the battery is being charged.
“UPDATE MODE”
“NETWORK NOT FOUND”
“SERVICES NOT FOUND”
“SIGNAL NOT DETECTED”
“FULL BATTERY”
“MPEG-2 NOT DETECTED”
“LOADING NETWORK”
“LOADING SERVICES”
“HIGH TEMPERATURE”
When the instrument is being updated.
MESSAGE
DESCRIPTION
The instrument cannot find a TV network.
The instrument cannot detect the services of a network.
When no signal is detected.
Battery fully charged.
It is not detecting the Transport Stream MPEG-2 signal.
After finding a signal, needs a time to load the network.
After finding a network, needs a time to load services.
The operation temperature is too high.
The instrument must be switched off for a while.
If the problem persists, contact with the technical support.
Find the user’s manual on the download area at: www.promaxelectronics.com
Navegation Keys:
QUICK START GUIDE
PRESS
SHORT PRESS: NEXT TEST POINT
LONG PRESS (1s): PREVIOUS TEST POINT
v1.2 (0 DG0102) 24/01/2013