xpr MTPX-MW Installation guide

Type
Installation guide
www.xprgroup.com 1
Multi technology RFID Readers
Rev. 1.02 - 30.01.2023
EN
MTPX-MHWO, MTPX-MW, MTPX-HW, MTPX-HO, MTPX-MHW, MTPX-MO, MTPX-MWO
Reference MTPX-MHWO MTPX-MW MTPX-HW MTPX-HO MTPX-MHW MTPX-MO MTPX-MWO
Technology
RFID 125 KHz X X X
RFID 13.5 MHz X X
Interface
Wiegand Output X X
OSDP Interface X X X
WS4 Interface X X X
Customised
RS485 Output X X X
Supported
credentials
EM4100 X X X
HID 125 KHz Compatible X X X
HID iClass CSN X X
Mifare CSN (Classic,
Desire, Plus, Ultralight),
NTAG CSN
X X
ISO 15693 X X
Encrypted DesFire*
(EV1, EV2, EV3) X X
Technical
characteristics
Power Supply 9 - 15 VDC
Maximum current
consumption @ 12 VDC 150 mA 150 mA 60 mA 60 mA 150 mA 150 mA 150 mA
Sound Indicator Internal buzzer
Led Indicators Red, Green and Orange (Red + Green)
Micro USB connector Built-in Micro USB connector for protocol selection, coniguration and irmware update
Environmental rating Outdoor, IP65
Operating temperature -30°C to +60°C
Operating humidity 5% - 95% relative humidity, non-condensing
Mounting Surface mount
Panel Connection Terminal
Dimensions (H x W x D) 92 x 51 x 27 mm
SPECIFICATIONS
INSTALLER’S MANUAL
www.xprgroup.com 2
• Wrap the wires around the ferrite core (1 turn).
• The ferrite core is provided with the kit and it is used to reduce the EMI.
MOUNTING
FERRITE CORE MOUNTING
5 mm 3 (3 x 30mm) 1 (M3 x 8mm) Front Back
Rubber gasket
6 mm 2 (4 x 30mm) 3 (M3 x 8mm) 1 (M3 x 8mm)
Bus for
the readers
Ferrite Core
MOUNTING WITH MT-SPACER
TERMINAL BLOCKS AND DIPSWITCH
DIP Switch 1
OSDP mode: SCBK reset
WS4 mode: Reader address
RS485 bus termination
DIP Switch 2
120 ohm OFF
RS485 bus termination
DIP Switch 2
120 ohm ON
Micro USB
www.xprgroup.com 3
TERMINALS DESCRIPTION OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
A RS485 line RS485 A (+) RS485 B (+) XRS485 A (+)
B RS485 line RS485 B (-) RS485 B (-) XRS485 B (-)
D0 Output X X D0 X
D1 Output X X D1 X
LG Input Input 1
(Dry contact to GND only) XGreen LED input Green LED input
LR Input Input 1
(Dry contact to GND only) XRed LED input Red LED input
BUZZ Input X X Buzzer input Buzzer input
+12V Power Supply
GND Ground
T Tamper
X
(Tamper state is reported
by RS485)
X
(Tamper state is
reported by RS485)
T Tamper X X
TERMINALS
DIP SWITCH
CABLING
SIGNALISATION
DIP SWITCH DESCRIPTION OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
SW 1 Setup
SCBK Reset: Power the
reader. Set DIP Switch 1
to ON and in the less than
5 sec set it back to OFF
position.
The readers for Doors
1.0 and 2.0 must be at
address 0 and those
for Doors 1.1 and 2.1 at
address 1.
For doors equipped with
2 readers, one must be at
address 0 and the other
at address 1.
X X
SW 2 RS485 120 OHM
termination X
CABLING DESCRIPTION OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Max length Cable Length 1200m 80m 150m 1200m
Cable Recommended
cable type
Multiconductor cable
2 twisted pair with
shielding
Multiconductor cable
2 twisted pair with
shielding
Untwisted, shield-
ed, 0.22 mm2 min.
For longer distance
above 20 m use
larger diameter.
Multiconductor
cable 2 twisted pair
with shielding
SIGNALISATION DESCRIPTION OSDP
CONFIGURATION
WS4
CONFIGURATION
WIEGAND
CONFIGURATION
CUSTOM RS-485
CONFIGURATION
Reader ONLIne
Reader is in
communication
with controller
Managed by Controller Managed by Controller Managed by
Controller
Managed by
Controller
Reader OFFLIne
Reader lost
comunication with
controller
Red LED Blinks Red LED Blinks fast X X
www.xprgroup.com 4
This product herewith complies with requirements of EMC directive 2014/30/EU, Radio Equipment Directive 2014/53/EU. In addition it complies with RoHS2 directive EN50581:2012 and RoHS3 Directive 2015/863/EU.
*Important: These accessories are not included with the readers!
SOFTWARE SETTINGS
XPR Toolbox is software for settings and irmware update of the reader. XPR Toolbox can be downloaded from a
https://software.xprgroup.com/. To setup the reader or update the irmware, run the XPR Toolbox and select ”Genera-
tion 2” and the appropriate model, and click on “Open” tab. Follow the instruction in the software to set up or update
irmware. Connect the reader to PC using Micro USB connector. No additional power for the reader is required. If the
reader is used with EWS Controller, reader setting must be done by PROSCS software.
ACCESSORIES (Optional)*
MTSPACER Surface mounts spacer for the MINI range housing. It’s the perfect accessories to install easily your
MINI range reader. It has six break-out openings for sheathed cabling. Smart and easy to install.
MCMINI Mini metal covers for
the MINI Range.
Metal protection Covers for Single
MINI range readers.
A304 brushed steel, compulsory
cover for biometric MINI range for
outside use.
53.42
97.92
R4.10
R2.40
70.0711.73
33.40
9.12
59.84
A
A
BB
CC
3(M3x3mm)
2(3mm x 4mm)
12
96.92
9.01
9.04
6.30
4.80
50.37
SECTION
A-A
Breaking Wall for cable
16.50
SECTION
B-B
Braking Wall for Cable
Braking Wall for Cable
TRUE R3.99
8.15
9
19
SECTION
C-C
Braking Wall for Cable
Braking Wall for Cable
USP Optional single metal plate
to it single US electrical gang
boxes. Also ideal for retroit to
cover pre-or old installation (small
wall damages, chips, paint work,
etc.) USP are supplied in the same
color as the readers used for a
blending aesthetic design.
70.00