Cisco Systems OL-11568-01 User manual

Category
Network switches
Type
User manual

Cisco Systems OL-11568-01 is a Data Center Infrastructure Design Guide that provides guidelines for designing and building a data center switching infrastructure. It covers various technologies and best practices for designing scalable, resilient, and secure data center networks. Some key capabilities and use cases of this guide include:

  • Provides design guidance for Layer 2 and Layer 3 data center networks, including routing protocols, VLANs, and security considerations.
  • Includes recommendations for choosing and configuring spanning tree protocols to prevent network loops and ensure network stability.

Cisco Systems OL-11568-01 is a Data Center Infrastructure Design Guide that provides guidelines for designing and building a data center switching infrastructure. It covers various technologies and best practices for designing scalable, resilient, and secure data center networks. Some key capabilities and use cases of this guide include:

  • Provides design guidance for Layer 2 and Layer 3 data center networks, including routing protocols, VLANs, and security considerations.
  • Includes recommendations for choosing and configuring spanning tree protocols to prevent network loops and ensure network stability.
Corporate Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 526-4100
Data Center Infrastructure Design Guide
2.1—Readme File
OL-11568-01
ALL DESIGNS, SPECIFICATIONS, STATEMENTS, INFORMATION, AND RECOMMENDATIONS (COLLECTIVELY,
"DESIGNS") IN THIS MANUAL ARE PRESENTED "AS IS," WITH ALL FAULTS. CISCO AND ITS SUPPLIERS DISCLAIM
ALL WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTY OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE
PRACTICE. IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL,
CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR
DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THE DESIGNS, EVEN IF CISCO OR ITS SUPPLIERS
HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
THE DESIGNS ARE SUBJECT TO CHANGE WITHOUT NOTICE. USERS ARE SOLELY RESPONSIBLE FOR THEIR
APPLICATION OF THE DESIGNS. THE DESIGNS DO NOT CONSTITUTE THE TECHNICAL OR OTHER PROFESSIONAL
ADVICE OF CISCO, ITS SUPPLIERS OR PARTNERS. USERS SHOULD CONSULT THEIR OWN TECHNICAL ADVISORS
BEFORE IMPLEMENTING THE DESIGNS. RESULTS MAY VARY DEPENDING ON FACTORS NOT TESTED BY CISCO.
CCVP, the Cisco Logo, and the Cisco Square Bridge logo are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live,
Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, BPX, Catalyst, CCDA, CCDP, CCIE, CCIP,
CCNA, CCNP, CCSP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems
Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me
Browsing, FormShare, GigaDrive, GigaStack, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net
Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networking Academy, Network Registrar, Packet,
PIX, ProConnect, RateMUX, ScriptShare, SlideCast, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and
TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner
does not imply a partnership relationship between Cisco and any other company. (0612R)
Data Center Infrastructure Design Guide 2.1—Readme File
© 2007 Cisco Systems, Inc. All rights reserved.
iii
Data Center Infrastructure Design Guide 2.1—Readme File
OL-11568-01
CONTENTS
What is Included in this DG Release? 1
Contents
iv
Data Center Infrastructure Design Guide 2.1—Readme File
OL-11568-01
Corporate Headquarters:
Copyright © 2006 Cisco Systems, Inc. All rights reserved.
Cisco Systems, Inc., 170 West Tasman Drive, San Jose, CA 95134-1706 USA
Data Center Infrastructure Design Guide 2.1—
Readme File
What is Included in this DG Release?
This design guide (DG) provides guidelines for designing and building the data center switching
infrastructure.
Table 1 lists the technologies used in the data center infrastructure design documented in version 2 of
this design guide. This table provides a quick glance of the topics and lists the timeframe (current or
future) of documentation availability for each technology.
Table 1 Cisco Data Center Technologies and DG Status
Technology/Product Description Other In this DG?
Cisco Catalyst 6500
WS-X6708-10G-3C
8 port 10 GigE line card for the
Catalyst 6500 Series switch
6708 notations have been added
to reflect the increased port
density. Testing is scheduled for
a future DG release. The data
sheet is available at:
http://www.cisco.com/en/US/pr
oducts/hw/switches/ps708/prod
ucts_data_sheet09186a00801dc
e34.html
No
Cisco Catalyst 6500 next generation
hardware—Sup720 and 6700 Series
line cards.
This DG is based on lab testing using
the Sup720 and 6700 Series line
cards in the Cisco Catalyst 6500
platform in core, aggregation, and
access layer switches.
Native 12.2.18 SXD3 was used
in the lab environment.
Yes
2
Data Center Infrastructure Design Guide 2.1— Readme File
OL-11568-01
What is Included in this DG Release?
Application Control Engine (ACE) The ACE module introduces a next
generation load balancer and security
services module that permits higher
performance and active-active
designs. The ACE module is not an
available product at the time of this
writing.
No
Firewall Services Module (FWSM)
Release 3.1
Release 3.1 of the FWSM software
introduces several new capabilities
including Private VLAN support and
active-standby context groups, which
permit load balancing of contexts
across an FWSM redundant pair.
Release 3.1 is not available at the
time of this writing.
No
Data center security See the data center security DG
at the following URL:
http://www.cisco.com/en/US/net
sol/ns656/networking_solutions
_design_guidances_list.html#an
chor3
No
Cisco CatOS-IOS hybrid Hybrid CatOS-IOS software in the
Cisco Catalyst 6500 platform
This DG is based on the Cisco
Native IOS solutions only in the
Cisco Catalyst 6500 and
4948-10GE-based products.
No
Pervasive 10GE This design guide focuses on the use
of 10GE technology as a primary
technology used in access layer
uplinks, aggregation, and core
connections.
Yes
Server fabric switching—
Infiniband
Designing for HPC or database
clusters using Infiniband technology
No
Service module integration (for
example, FWSM, IDS, CSM, NAM,
and SSLSM)
Integration of service modules and
appliances into the data center
infrastructure
Service modules are examined
for interoperability and
placement guidelines. Detailed
design and configuration guides
can be found at the following
URL:
http://www.cisco.com/en/US/net
sol/ns656/networking_solutions
_design_guidances_list.html#an
chor3
No
1RU access layer design Using 1RU switches in the access
layer design best practices
Testing is focused on the Cisco
Catalyst 4948-10GE 1RU
switch.
Yes
Table 1 Cisco Data Center Technologies and DG Status (Continued)
3
Data Center Infrastructure Design Guide 2.1— Readme File
OL-11568-01
What is Included in this DG Release?
Table 2 lists the technologies used in the data center infrastructure design documented in the previous
v1.1. Note that version 2.1 builds on the v1.1 and v 2.0 design recommendations and it is not intended
to be a replacement.
Environmental Designing for proper cabling,
cooling/airflow, and power
configurations
No
Network Management Using the NAM, CVDM,
CiscoWorks, Netflow, or other
management/configuration tools
No
Geographically dispersed clustering
(also known as stretch clusters)
Designing in support of extending
Layer 2 domains to support HA
clustering across metro or wide area
networks
No
CPU protection from STP loop
conditions
Design best practices in limiting the
impact of failures related to spanning
tree loop conditions
Yes
Spanning tree—Using 802.1w
Rapid PVST+ and 802.1s MST
Designing scalable spanning tree
domains using 802.1w and 802.1s
and related features
Yes
Layer 2 access design Designs using L2 looped and
loop-free access layer topologies
Yes
Layer 3 access design Designs using L3 access layer
topologies
No
Service layer switch design How to move service modules out of
the aggregation layer and into a
separate service switch chassis for
CSM and SSL modules
Yes
Distributed Forwarding Card
placement and benefits
Where to use DFC3 daughter cards to
improve distributed switching
performance in the data center
Covered in multi-tier and server
cluster architecture chapters
Yes
Enterprise campus segmentation The need to isolate/segment multiple
logical network environments on the
same physical network for
administration, security, or other
purposes.
This is covered outside of this
DG document.
No
Use of NSF/SSO for high
availability in the data center
Where to use redundant supervisors
in the data center architecture, and
designing to support required
failover times
Yes
Table 1 Cisco Data Center Technologies and DG Status (Continued)
4
Data Center Infrastructure Design Guide 2.1— Readme File
OL-11568-01
What is Included in this DG Release?
Table 2 Technologies used in the Data Center Infrastructure Design Documented in DG v1.1
Technology/product Description
Layer 3 data center design Using OSPF and EIGRP in the data center design
Layer 3 security Using dynamic routing protocol authentication
Use of VTP in Layer 2 designs Why not to use VTP in the data center
Choosing a spanning tree protocol Explains the differences between 802.1w, Rapid PVST+ and
MST and when to use each
Using LoopGuard and UDLD
Using PortFast and TrunkFast
Layer 2 security Explains VLAN hopping, MAC flooding, ARP spoofing, and
spanning tree vulnerabilities
Default gateway design Reviews configurations for HSRP in the data center
ARP table tuning Tuning the ARP table size to optimize traffic characteristics
NIC teaming design Covers the various NIC teaming methods and connectivity
options
Mainframe OSA and OSPF design Explains mainframe connectivity options when using the OSA
interface and covers IP addressing and OSPF configurations
PortFast and BPDU Guard When to use PortFast and BPDU Guard on server ports
Port security Covers server port security options
Server port configurations Examples of server port switch configurations
Network management configuration Configuring user names and passwords, VTY access, SNMP,
and logging
VLAN configuration Configuring VTP, MAC address reduction, and other VLAN
features
Spanning tree configuration How to configure Rapid PVST+, MST, and protection from
loops with UDLD and LoopGuard
Switch-to-switch trunk configuration EtherChannel and trunking configuration between the
aggregation layer switches
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Cisco Systems OL-11568-01 User manual

Category
Network switches
Type
User manual

Cisco Systems OL-11568-01 is a Data Center Infrastructure Design Guide that provides guidelines for designing and building a data center switching infrastructure. It covers various technologies and best practices for designing scalable, resilient, and secure data center networks. Some key capabilities and use cases of this guide include:

  • Provides design guidance for Layer 2 and Layer 3 data center networks, including routing protocols, VLANs, and security considerations.
  • Includes recommendations for choosing and configuring spanning tree protocols to prevent network loops and ensure network stability.