Omron QX-830 Configuration Guide

Type
Configuration Guide
Copyright ©2021 Omron Microscan Systems, Inc. P/N 83-210830 Rev E
Pin Assignments
Item Description Part Number
1QX-830 Compact Industrial Scanner FIS-0830-XXXXG
2QX-1 Interface Device 98-000103-02
3QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m 61-000162-02
4QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m 61-000152-02
5QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m 61-000153-02
6QX Power Supply, 24V, 100-240VAC, +24VDC, M12 12-pin Socket 97-000012-01
7QX Cordset, Host, Ethernet, M12 8-pin Plug (Ultra-Lock) to RJ45, 1 m 61-000160-01
or QX Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m 61-000160-02
8QX Cordset, M12 12-pin Plug / M12 12-pin Socket to MS-Connect 210, RS-232, 2 m 61-000158-03
9Photo Sensor, VIS, NPN, Light On/Dark On 99-9000016-01
Note: Additional cordsets and accessories are available in the Omron Microscan Product Pricing Catalog.
+10-28V
Trigger
Ground
Trigger/New Master / Input 1 Common
Ground
Output 3
Output 1
Output 2
New Master Default
Power
Input Common
Output Common
RS-232 RxD
Trigger
RS-232
TxD
QX-830 (Back View)
QX-1 Interface
Device (Top View)
Input
Common
RS-422/485 RxD (–)
RS-232 TxD/
RS-232 RTS
Trigger
RS-232 RxD/
RS-232 CTS
Power
Ground
RS-422/485
RxD (+)
RS-422/485
TxD (+)
RS-422/485 TxD (–)
Input 1 Terminated
Connector A (All Models)
M12 12-pin Plug
Connector B (Serial Models)
M12 12-pin Socket
QX-1 Trigger Connector
4-pin Socket
Connector A is a serial M12 12-pin plug. It is the same for all
models of the QX-830.
Connector B is a serial M12 12-pin socket for serial models and
an Ethernet M12 8-pin socket for Ethernet models.
Important: See the QX-830 Compact Industrial Scanner User
Manual for a list of the wire colors that correspond to each pin.
Connector T on the QX-1 Interface Device is the trigger connector.
Connectors 1, 2, and 3 can be used to bus power and data as
required by the application.
TX (+)
RX (–)
RX (+)
TX (–)
Terminated
Te r m i n at e d
Connector B (Ethernet Models)
M12 8-pin Socket
Terminated
Te r m i n a te d
POWER
TRIGGER
1, 3, T 1, 2, 3, T
1, 2, 31, 3
QX–830
Compact Industrial Scanner
Configuration Guide
Hardware Required
9
QX-830 Configuration
Standalone Configuration
Daisy Chain Configuration
Multidrop Configuration
Ethernet (with QX-1)
Serial (with QX-1) Serial with MS-Connect 210
(without QX-1)
Important:
Configure
reader off-line
and then connect
to network when
ready for
dynamic use.
11
1
22
33
5
66
7
8
99
9
Ethernet (with QX-1)
Serial (with QX-1)
Serial or Ethernet (without QX-1)
Important: Do not attempt to
power more than four scanners
with a single power supply in a
daisy chain configuration. Add a
QX-1 and one power supply for
every four additional scanners in
the daisy chain.
Important: Configure reader off-line
and then connect
to network when
ready for dynamic use.
111111
111
1
22
33 3333
3334
5
66
6
7
7
99
Multidrop Network with MS-Connect 5100
111
222
333
333
66
99
www.microscan.com
Copyright ©2021 Omron Microscan Systems, Inc.
  • Page 1 1
  • Page 2 2

Omron QX-830 Configuration Guide

Type
Configuration Guide

Ask a question and I''ll find the answer in the document