Omron QX-870 Industrial Raster Scanner Configuration Guide

  • I've reviewed the configuration guide for the Omron Microscan QX-870 Industrial Raster Scanner and its accessories, including the QX-1 interface device and various cordsets. The document provides detailed information about the hardware required, pin assignments, and different configuration options like standalone, daisy chain, and multidrop setups. I'm ready to assist with any questions you might have about this device and its implementation.
  • What is the part number for the QX-870 Industrial Raster Scanner?
    What is the purpose of the QX-1 Interface Device?
    What is included in the Hardware Required section?
    What are the main types of supported configurations?
    What is the maximum number of scanners that can be powered in daisy chain configuration by one power supply?
Copyright ©2020 Omron Microscan Systems, Inc. P/N 83-210870 Rev E
Pin Assignments
Item Description Part Number
1QX-870 Industrial Raster Scanner FIS-0870-XXXXG
2QX-1 Interface Device 98-000103-02
3QX Cordset, Common, M12 12-Pin Socket to M12 12-Pin Plug, 1 m 61-000162-02
4QX Cordset, Host, Serial, M12 12-Pin Plug to DB9 Socket, 1 m 61-000152-02
5QX Cordset, Host, Serial, M12 12-Pin Socket to DB9 Socket, 1 m 61-000153-02
6QX Power Supply, 100-240VAC, +24VDC, M12 12-Pin Socket 97-000012-01
7QX Cordset, Host, Ethernet, M12 8-Pin Plug to RJ45, 1 m 61-000160-03
8QX Cordset, M12 12-Pin Plug to MS-Connect 5100, 3 m 61-000161-01
9QX Cordset, M12 12-Pin Plug / M12 12-Pin Socket to MS-Connect 210, RS-232, 2 m 61-000158-03
10 QX Photo Sensor, M12 4-Pin Plug, NPN, Dark On, 2 m 99-000020-02
Note: Additional cordsets and accessories are available in the Omron Microscan Product Pricing Catalog.
+10-28V
Trigger
Ground
Trigger/New Master / Input 1 Common
Ground
Output 3
Output 1
Output 2
New Master Default
Power
Input Common
Output Common
RS-232 RxD
Trigger
RS-232
TxD
QX-870 (Base View)
QX-1 Interface
Device (Top View)
Input
Common
RS-422/485 RxD (–)
RS-232 TxD/
RS-232 RTS
Trigger
RS-232 RxD/
RS-232 CTS
Power
Ground
RS-422/485
RxD (+)
RS-422/485
TxD (+)
RS-422/485 TxD (–)
Input 1 Te r m i na t e d
A (All Models) M12 12-Pin Plug
B (Serial Models) M12
12-Pin Socket
Trigger Connector 4-Pin Socket
A is a serial M12 12-pin plug. It is
the same for all models of the QX-870.
B is a serial M12 12-pin socket for
serial models and an Ethernet M12
8-pin socket for Ethernet models.
P/M is a serial M12 12-pin plug.
T is a 4-pin Micro-Change socket
(identical
to the QX-1 trigger
connector shown below).
Important: See the QX-870
Industrial Raster Reader User
Manual for a list of the wire colors
that correspond to each pin.
Connector T on the QX-1 Interface Device is the trigger connector.
Connectors 1, 2, and 3 can be used to bus power and data as
required by the application.
TX (+)
RX (–)
RX (+)
TX (–)
Terminated
Terminated
B (Ethernet Models) M12
8-Pin Socket
Terminated
Terminated
POWER
TRIGGER
AB
P/M
T
P/M (All Models) M12 12-Pin Plug
N/C
RS-422/485 TxD (–)
N/C
N/C
N/C
Power
Ground
RS-422/485
RxD (+)
RS-422/485
TxD (+)
RS-422/485 RxD (–)
N/C N/C
QX–870
Industrial Raster Scanner
Configuration Guide
Hardware Required
QX-870 Configuration
Standalone Configuration
Important: Configure Ethernet-enabled readers off-line and then connect to network when ready for
dynamic use.
Daisy Chain Configuration
Multidrop Configuration
With QX-1
Without QX-1 Serial with MS-Connect 210
1
1
1
2
3
6
6
4 or 7
10
10
57
9
10
Important: Do not attempt to power more than four scanners with a
single power supply in a daisy chain configuration. Add a QX-1 and
one power supply for every four additional scanners in the daisy chain.
1111
333
6
7
10
4
Multidrop Network with MS-Connect 5100
1111
3336
3
10
10
1010
8
Copyright ©2020 Omron Microscan Systems, Inc. www.microscan.com
/