Sunricher SR-2411-RF-RGBW User manual

Type
User manual
+A1 D2
DALI OUTPUT
D1
RF to DALI DT8 RGBW Controller
Learning
A1-A2: 8-230V
-A2
IMP
Zone Group
Scene
RF to DALI DT8 Group & Scene Controller for RGBW
09.2411RFRGB.04793
Function introduction
Important: Read All Instructions Prior to Installation
Radio frequency
Output
Power Supply
Current Consumption
Operating temperature
Relative humidity
Dimensions(LxWxH)
Product Data
Rotary Switch for setting
DALI Scenes to be controlled
(Total 16 Scenes)
Rotary Switch for setting
DALI Groups to be controlled
(Total 16 Groups)
Rotary Switch for setting
the controller to a zone
of paired RF remote
DALI signal output8-230V PUSH switch input
DO NOT install with power applied to device.
DO NOT expose the device to moisture.
Safety & Warnings
How to set the controller to a zone of RF remote:
During pairing process, you do not have to choose a zone on the RF remote. This can be done by selecting a zone
number with a zone rotary switch on the controller, and the rotary switch position can be selected from 0-15. Since RF
remote zone number starts with 1, the rotary switch position shall start with number 1. Set the zone rotary switch position
at 1, 2, 3, ……, X, the controller will be controlled by a corresponding zone 1, 2, 3, ……, X on the RF remote. The value
of X depends on how many zones the remote has. If the remote has only one zone, please set the rotary switch position
at 1.
Note: each controller can pair with max. 8 different RF remotes.
2. Delete the pairing
How to delete the pairing:
3. Set starting number of DALI Group to be controlled via rotary switch: (0-15 selectable)
This DALI controller enables dimming commands and DT8 commands to be sent to 1 Group of devices on the DALI
circuit. A rotary switch is used to select Groups you would like to control and set the starting Group number, and total 16
Groups (0-15) can be selected.
When the rotary switch arrow position is at 0, all DALI devices on the circuit are controlled through broadcast.
When the rotary switch arrow position is at X except 0 (1-15), the controller controls devices in DALI Group X-1.
Please refer to the detailed Group setting table as follows:
Operation
Learning key for pairing
with RF remote RF signal LED indicator
869.5/434/916.5MHz
DALI signal
Powered by DALI Bus
8mA
0-40°C
8% to 80%
45.5x45x20.3mm
RF to DALI Group & Scene Controller
Receives RF signal and outputs DALI signal to DALI line
Comply to DALI standard protocol IEC 62386-102, IEC 62386-207, IEC 62386-209
DT8 for color changing, color type: RGBW, compatible with universal DALI masters that support DT8 commands
DALI Bus Powered
Can be controlled by RF remotes and compatible with a variety of RGBW RF remotes
Can be set to any zone of the paired RF remote by a rotary switch
Can be WiFi controlled while working with a WiFi-RF converter
Can be controlled by universal 8V-230V input single wire PUSH switch
Enable to control 1 DALI Group of devices
Enable to control all devices on DALI line via broadcast
The number of DALI Scenes to be controlled depends on the paired RF remote
Enable to set starting number (0-15) of DALI groups to be controlled by a rotary switch
Enable to set starting number (0-15) of DALI scenes to be controlled by a rotary switch
Built-in 10 color sequences
Each DALI line can install multiple controllers for multi control points
Turn on the RF remote Click the “Learning” key on
the RF to DALI controller
Touch the color wheel or slider bar (click any button
if no color wheel or slider bar) on the remote
RF signal LED indicator on the controller and LED light connected
with DALI slave controller blink twice to indicate successful pairing.
How to pair:
1. Pair to RF remote and set the controller to a zone of RF remote
Rotary Switch
Position
DALI Group
Selected
0
Broadcast
1
0
2
1
3
2
4
3
5
4
6
5
7
6
8
7
9
8
10
9
11
10
12
11
13
12
14
13
15
14
Note: the DALI slave controllers on the circuit shall be assigned to one or more DALI Groups by a DALI master
first.
4. Set starting number of DALI Scenes to be controlled via rotary switch: (0-15 selectable)
This DALI controller enables Scene selection commands to be sent to the DALI circuit. A rotary switch is used to set
the starting number of DALI Scenes to be controlled, and total 16 Scenes (0-15) can be selected. Assume that the rotary
switch position is at X (0-15), the starting DALI Scene to be controlled will be DALI Scene X.
Press and hold down the “Learning”
key on the controller
RF signal LED indicator and LED light connected with DALI
slave controller blink once to indicate pairing deleted successfully.
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Lea rning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Lea rning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
Rotary Switch
Position 01 2 345678 9 10 11 12 13 14 15
DALI Scene
assigned to S1
DALI Scene
assigned to S2
DALI Scene
assigned to S3
DALI Scene
assigned to S4
01 2 345678 9 10 11 12 13 14 15
1 2 345678 9 10 11 12 13 14 15 0
2345678 9 10 11 12 13 14 15 0 1
345678 9 10 11 12 13 14 15 0 1 2
Note: the light value of DALI Scenes stored in the slave controllers can be configured by a DALI master first,
then they can be recalled by the RF remote. Without a DALI master, please first save scenes with the RF remote,
and then they can be recalled.
5.Controlled by the Paired RF Remote
Please refer to the user manual of corresponding RF remote that is paired to the controller for detailed operation
instructions. Depending on the DALI Group setting, the RF remote may control all devices on the circuit via broadcast or
control devices in a selected DALI Group. When setting the controller to a zone on RF remote by rotary switch, please
select corresponding zone number on the remote to control.
6.Controlled by PUSH switch
While connected with a PUSH switch, click the button to turn ON/OFF, press and hold down the button to
increase/decrease light intensity. Depending on the DALI Group setting, the PUSH switch may control all devices on the
circuit via broadcast or control devices in a selected DALI Group.
Wiring Diagram
AC Input
PUSH
L N
DALI bus
D1 D2
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
If you use multiple receivers, you have two choices:
Option 1: have all the receivers in the same zone, like zone 1
Zone 1
Option 2: have each receiver in a different zone, like zone 1, 2, 3 or 4
Zone 1 Zone 2 Zone 3
RF remote
RF remote
The number of scenes which can be controlled depends on the paired RF remote. Assume that the number of scenes
can be controlled by the paired RF remote is Y (with scene buttons S1, S2, S3, ……, SY), and the starting DALI Scene to
be controlled is X. Then S1 will control DALI Scene X, S2 will control DALI Scene X+1, S3 will control DALI Scene X+2,
……, SY will control DALI Scene X+(Y-1).
Please refer to the detailed Scene setting table as follows (Assume that the RF remote can control 4 scenes, which
means Y=4):
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Lea rning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Lea rning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Learning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
+A1 D2
DALI O UTPUT
D1
RF to DA LI DT8 RG BW Cont rolle r
Learning
A1-A 2: 8-23 0V
-A2
IMP
Zon e Group
Sce ne
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
(1)With Push
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
(2)With Push LV
AC Input
L N
PUSH LV
Power Supply
DALI bus
D1 D2
DT8 DALI RGBW Dimmer
0-6 0 -9
LED OUTP UT
12-36V D C
POW ER IN PUT
V-
V-
V+
V+
+
R-
G-
B-
W-
D1
D2
D1
D2
DALI SIG NAL
V+ V-
L
N
GV+
V-
OUTPUT
INPUT
12V/24V/36V
CV PSU
+A1 D2
DALI OU TPUT
D1
RF to DALI DT 8 RGBW Contro ller
Learning
A1-A2: 8- 23 0V
-A2
IMP
Zone Group
Scene
  • Page 1 1
  • Page 2 2
  • Page 3 3

Sunricher SR-2411-RF-RGBW User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI