ADTRAN DS3 User manual

Category
Network switches
Type
User manual

This manual is also suitable for

TOTAL ACCESS 4303 DS3 MODULE
DS3 MODULE
CLEI: SLPOCD0C_ _
61200333L1-22B
0310
For a complete Installation and Maintenance Practice (P/N 61200333L1-5): 877-457-5007, Faxback Document 860. Please have your fax number ready.
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
FRONT PANEL LEDs
ONLINE Off Blown fuse or no power supplied to the shelf
Green Online
Flashing Green Offline
Amber Self-test in progress
Red Module failure
Flashing Red Self-test failure
STATUS Green Active DS3 Module
Flashing Green Standby DS3 - redundancy enabled
Flashing Red Standby DS3 - cannot automatically become the active
DS3 while the current active DS3 is installed
DS3 Off DS3/DS1 not configured for use
Green DS3/DS1 signal present and synchronized; channel is
configured for use
Amber DS3/DS1 test in progress (includes port self-test)
Red DS3/DS1 alarm present
Flashing Red DS3/DS1 error
NOTE: The Total Access 4303 DS3 Module requires SCU firmware of C.02 or greater.
INSTALLATION
Insert the module into the desired slot (1 through 4 only) (hot insertion permissible).
The module connects to connectors on the backplane. Connecting the BNC Module
(P/N 1200323L1) to the connectors provides two dual BNC connectors (see the BNC
Module Job Aid, 61200323L1-22).
The Total Access
®
4303 SCU automatically detects the presence of the module. There
is no need to reboot.
Once installed, use the terminal menus to configure and control the module (see the
SCU Job Aid, 61200334L1-22).
Use the arrow keys on the VT100 terminal keyboard to move to the Modules menu;
press ENTER in the Menu column of the appropriate module.
JOBAID
#61200333L1-22B#
SPECIFICATIONS
Specifications
Framing M13 or C-Bit Parity
Line Coding B3ZS (bipolar 3 zero substitution)
Line Build Out 0 to 50 feet (Short)
51 to 450 feet (Long)
Tests Self-test
Local Line and Payload Loopbacks
Remote Line and Payload Loopbacks
Line Rate 44.736 Mbps ± 895 bps
Terminating Impedance 75 ohms ± 5%, unbalanced
Power 12 watts
Compliance FCC Part 15, UL 60950, NEBS Level 3
Temperature Operation: 0ºC to 50ºC
Storage: –40ºC to 70ºC
Relative Humidity To 95% noncondensing
COMPLIANCE
The Total Access 4303 DS3 module is NRTL listed to the applicable UL standards.
The Total Access DS3 is to be installed in a restricted access location and in a Type
“B” or “E” enclosure only.
This device complies with Part 15 of the FCC rules. Operation is subject to the fol-
lowing two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the users
authority to operate this equipment.
WARRANTY
ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found at www.adtran.com/warranty. U.S. and Canada customer Faxback:
877-457-5007, Document 414.
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC)
Installation Code (IC) A
TOTAL ACCESS 4303 DS3 MODULE
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61200333L1-22B
Total Access 4303
Module Menu
Part Number
Serial Number
CLEI Code
Board Revision
[Prt]
Rx Alarms
Far End Alarms
CBIT Status (Rx Framing)
[Prt]
Clear Results <+>
Errored Seconds - line
Severely Errored Seconds - line
LOS Seconds - line
Code Violation - path
Errored Sec - path
SEF/AIS Seconds - path
Severely Errored Sec - path
Unavailable Sec - path
DS3 Info
DS3 Alarms
[Prt]
Port Name
Frame Format
DS3 Configurations
LoopBack
DS3 Test
[Prt]
Port Name
State
DS1 Configuration
DS3 Perf Current
DS3 Perf 15 Min
DS3 Perf 24 Hr
M13
CBIT
Clock Source
Recovered
Internal
LBO
Short
Long
[Prt]
Remote Status
None
Line
None
DS3 Line
DS1 #N Line (where N=1 to 28)
DS1 All Line
Auto
Auto BER
IS
IS AS
OOS
None
2E-7
• • •
9E-7
1E-6
• • •
7E-6
Frame Format
OSS Threshold
IS Threshold
D4
ESF
Auto TX Yellow Alarm
Transmit PRMs
Off
On
Remote Device
Accept
Ignore
Loopback Accept
Disabled
ADTRAN
Type 1
Type 2
G
G1
Remote LB
DS1 Alarm & Status
Disabled
Enabled
[Prt]
Clear Results <+>
Errored Seconds
Bursty Errored Seconds
Severely Errored Seconds
Severely Errored Frame Secs
Loss of Frame Count
Controlled Slip Seconds
Unavailable Seconds
Path Code Violations
Degraded Minutes
Test Status
Pattern Status Clear <+>
Pattern Error Inject <+>
DS1 Test
Redundancy
Minimum Switch Time
Switch Count
Clear Switch Count <+>
Force Switchover <+>
Disabled
1E-03
1E-04
1E-05
1E-06
DS1 Perf Current
DS1 Perf 15 Min
DS1 Perf 24 Hr
DS0 Alarms
DS0 Configuratiion
DS0 Map Status
[Prt]
Alarms
Status
BER
DS1 Signal Status
[Prt]
Rx
Tx
None
Line
Payload
Local Loopback
Remote Loopback
None
All Ones
All Zeros
QRSS
QRSS 56k
DALY
3-IN-24
1-IN-8
2-IN-8
[Prt]
DS0 Config
DS0 Not Used Count
Module Redundancy
G1
Test Pattern
Error Threshold
None
ATT Inband
ANSI FDL Line
ANSI FDL Pyld
NIU Inband
[Prt]
MENU TREE FOR THE DS3 MODULE TERMINAL MENUS