Muskoka 234-05-200-KIT User manual

Category
Fireplaces
Type
User manual

This manual is also suitable for

PLEASE READ THIS MANUAL BEFORE
INSTALLING AND USING APPLIANCE
WARNING!
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, AN ELECTRICAL SHOCK OR FIRE MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
Retain this manual for future use.
VEUILLEZ LIRE CE MANUEL AVANT L’INSTALLATION
ET L’UTILISATION DE VOTRE FOYER
AVERTISSEMENT!
SI LES RENSEIGNEMENTS DE CE MANUEL NE SONT PAS EXACTEMENT
SUIVIS, UN CHOC ÉLECTRIQUE OU UN INCENDIE PEUT SURVENIR, ET
CAUSER DES DOMMAGES, DES BLESSURES OU LA PERTE DE VIE
Conserver ce manuel pour une utilisation ultérieure.
Français p. 11 | Español p. 2020-10-352
POR FAVOR LEA LAS INSTRUCCIONES DE
INSTALACIÓN Y DE OPERACIÓN ANTES DE
USAR ESTE CAJA DE FUEGO
¡ADVERTENCIA!
SI NO SIGUE EXACTAMENTE LA INFORMACIÓN EN ESTE MANUAL, PODRÍA
RESULTAR EN CHOQUES ELÉCTRICOS O INCENDIO QUE PUEDEN CAUSAR
DAÑOS A LA PROPIEDAD, LESIONES PERSONALES O LA PÉRDIDA DE LA VIDA.
Guarde este manual para futuras referencias.
23-600-001
USE AND CARE GUIDE | GUIDE D’UTILISATION ET D’ENTRETIEN | GUÍA DE USO Y CUIDADO
ELECTRIC FIREBOX FOYER ÉLECTRIQUE HOGAR ELÉCTRICO
IMPORTANT:
SAVE THESE
INSTRUCTIONS.
IMPORTANT :
CONSERVER CES
INSTRUCTIONS.
IMPORTANTE:
GUARDE ESTAS
INSTRUCCIONES.
2
Table of Contents
Safety Information
1. Read all instructions before using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use
handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers,
clothes, and curtains at least 3 feet (0.9 meters) from the front of the heater and keep them away from the
sides and rear.
3. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the
heater is left operating and unattended.
4. Always unplug heater when not in use.
5. Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been
dropped or damaged in any manner. Return heater to authorized service facility for examination,
electrical or mechanical adjustment, or repair.
6. Do not use outdoors.
7. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate
heater where it may fall into a bathtub or other water container.
8. Do not run power cord under carpeting. Do not cover power cord with throw rugs, runners, or the like.
Arrange power cord away from trafc area and where it will not be tripped over.
9. To disconnect heater, turn controls to off, then remove plug from outlet.
10. Connect to properly grounded outlets only.
11. Do not insert or allow foreign objects to enter any ventilation or exhaust openings as this may cause an
electric shock or re, or damage the heater.
12. To prevent a possible re, do not block rebox air intakes or exhaust in any manner. Do not operate rebox
on soft surfaces, like a bed, where openings may become blocked.
13. A heater has hot and arching or sparking parts inside. Do not use in areas where gasoline, paint, or
ammable liquids are used or stored.
14. Use this heater only as described in this manual. Any other use not recommended by the manufacturer
may cause re, electrical shock, or injury to persons.
15. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable
power tap (outlet/power strip).
16. This electric replace is not designed for “zero” clearance wall and/or cabinet/millwork installations.
Accessibility for servicing and maintenance must be possible without disturbing building structures and/or
cabinet/millwork nishes.
17. SAVE THESE INSTRUCTIONS
Table of Contents ...........................2
Safety Information ...........................2
User Instructions ............................3
Grounding Instructions ......................3
Locating Your Fireplace .....................3
Mantel Installation ..........................3
Firebox Specications ....................... 3
Electrical Connection .......................3
Remote Control ............................4
Warranty ...................................5
Pre-Installation ..............................6
Planning Installation ........................ 6
Tools Required ............................6
Hardware Included ........................6
Package Contents .........................6
Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Maintenance ...............................8
Glass information. . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Maintenance of Motors .....................8
Battery Replacement .......................9
Circuit Diagram .............................9
Care and Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting ............................ 10
Service Parts ...............................11
3
Safety Information (continued)
USER INSTRUCTIONS
1. Any repairs to this appliance should be carried out by qualied/authorized service personnel only.
2. Under no circumstances should this appliance be modied. Parts having to be removed for servicing must
be replaced with original “OEM” (original equipment manufacturers) parts only.
3. This rebox is to be cleaned with a damp cloth (water) only.
IMPORTANT: Always unplug the power cord before cleaning the unit. Do not use any abrasive cleaners on
the unit.
4. Unplug this rebox when not in use.
GROUNDING INSTRUCTIONS
This heater is for use on 120 volts. The cord has a plug as shown in gure
1A in the diagram. An adapter as shown in gure 1C is available for
connecting three-blade grounding-type plugs to two-slot receptacles. The
green grounding lug extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box. The adapter
should not be used if a three-slot grounded receptacle is available.
(Note: Grounding adapter use prohibited in Canada)
LOCATING YOUR FIREPLACE
When choosing a location for your new replace, ensure the general instructions are followed. Also, for best
effect install the replace out of direct sunlight. It is safe to set the replace insert close to non-combustibles.
MANTEL INSTALLATION
Please refer to the detailed instructions that came
with the mantel that you purchased.
ELECTRICAL CONNECTION
A 15 Amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required to operate this appliance. Preferably,
the replace insert will be on a dedicated circuit as other appliances on the same circuit may cause the circuit
breaker to trip or the fuse to blow when the heater is in operation. The unit comes standard with a 6 ft (1.8 m)
long 3 wire cord, exiting out the back of the replace insert. Plan the installation to avoid the use of an extension
cord. Always plug heaters directly into a wall outlet/receptacle. Never use with an extension cord or relocatable
power tap (outlet/power strip).
23-600-001 SPECIFICATIONS
Fireplace Insert dimensions
(w x d x h)
24.74” x 8” x 17.32”
762.84 cm x 20.2 cm x 44 cm
Voltage 120 V
Frequency 60 Hz
Watts • Amps. 1440W • 12A
Grounding Pin
Cover of Grounded Outlet Box
Adapter
Grounding Lug
Metal Screw
Cover of Grounded Outlet Box
B
C
A
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS
OR LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER APPLIANCE.
WARNING: Electrical outlet wiring must comply with local building codes and other applicable
regulations to reduce the risk of re, electrical shock and injury to persons.
WARNING: Do not use this replace if any part of it has been under water. Immediately call a qualied service
technician to inspect the replace and replace any part of the electrical system which has been under water.
4
Safety Information (continued)
REMOTE CONTROL
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
This Class (B) device complies with Part 15 of the FCC Rules and Canadian ICES-003. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. There is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
This remote control requires 1 Lithium Coin Cell Battery (size CR2025), which is included.
CAUTION: Changes or modications to this unit not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
DO NOT mix old and new batteries.
DO NOT use rechargeable silver oxide cell batteries with remote control unit.
DO NOT mix alkaline, standard (Carbon-Zinc), or rechargeable (Nickel-Cadmium) batteries.
DO NOT dispose of batteries in re. Improper disposal may cause batteries to leak or explode.
WARNING: Never attempt to disassemble or alter the product in any way not instructed by this manual.
5
WHAT IS COVERED
The manufacturer warrants that your new electric replace is free from manufacturing and material defects for a
period of one year from date of purchase, subject to the following conditions and limitations.
This electric replace must be installed and operated at all times in accordance with the instructions furnished
with the product. Any alteration, willful abuse, accident, or misuse of the product shall nullify this warranty. This
warranty is non-transferrable, and is made to the original owner, provided that the purchase was made through
an authorized supplier of the manufacturer.This warranty is limited to the repair or replacement of part(s) found to
be defective in material or workmanship, provided that such part(s) have been subjected to normal conditions
of use and service, after said defect is conrmed by the manufacturer’s inspection. The manufacturer may, at
its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of the
defective part(s).
WHAT IS NOT COVERED
Any installation, labor, construction, transportation, or other related costs/expenses arising from defective part(s),
repair, replacement, or otherwise of same, will not be covered by this warranty, nor shall the manufacturer
assume responsibility for same. Further, the manufacturer will not be responsible for any incidental, indirect, or
consequential damages, except as provided by law.
All other warranties - expressed or implied - with respect to the product, its components and accessories, or any
obligations/liabilities on the part of the manufacturer are hereby expressly excluded. The manufacturer neither
assumes, nor authorizes any third party to assume, on its behalf, any other liabilities with respect to the sale of this
product. The warranties as outlined within this document do not apply to nonmanufacturer accessories used in
conjunction with the installation of this product.
This warranty does not cover the light bulb(s) included with the replace.
This warranty is void if: the replace has been operated in atmospheres contaminated by chlorine, uorine, or
other damaging chemicals; the replace is subjected to prolonged periods of dampness or condensation; the
replace is altered, willfully abused, damaged by accident, or misused in any way.
Make sure you have your warranty, your sales receipt, and the model/serial number of your product.
DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF. PLEASE CONTACT CUSTOMER SERVICE AT:
1 Year Warranty
1-877-447-4768
www.ghpgroupinc.com
271 Massey Road, Guelph, Ontario, N1K 1B2
6440 W. Howard Street, Niles, Illinois 60714
6
Pre-Installation
PLANNING INSTALLATION
To avoid scratching the nish, assemble the product on a soft, non-abrasive surface, such as carpet or cardboard.
Assembly of this product may require more than one person.
HARWARE INCLUDED
Note: Hardware not shown to actual size.
PACKAGE CONTENTS
AA
A B
Safety Goggles Phillips screwdriver
TOOLS REQUIRED
PART DESCRIPTION QUANTITY
AA Screws (ST4) 4
PART DESCRIPTION QUANTITY
A Fireplace Insert 1
B Remote Control 1
7
Operation
NOTE: When the heat function is used for the rst time, a slight odor may
be present. This is normal and should not occur again unless the heater is
not used for an extended period of time.
USING THE CONTROL PANEL
1. Check that the heater outlet grill is not covered or obstructed in
anyway, and make sure the power to the unit is switched on.
2. The replace can be accessed in two ways: Using the touchpad
control panel, or using the multifunction remote control unit.
3. Press the appropriate button to operate your replace:
1. Main Power Button: This button supplies power to
all of the replace functions. It must be turned on
for the replace to work.
2. Heater Control Button: This button controls the
heater ON/OFF. When the temperature unit is
set as ‘F”or “C”, the temperature scope are as
follows:
“F” =Fahrenheit temperature 86°F, 84°F, 82°F, 80°F,
78°F, 76°F, 74°F, 72°F, 70°F, 68°F, 66°F, 64°F, 62°F.
“C” =Celsius temperature 30°C, 29°C, 28°C, 27°C,
26°C, 25°C, 24°C, 23°C, 22°C, 21.C, 20°C, 19°C,
18°C, 17°C.
3. Flame Control Button: This button controls the
brightness of the ame effect with settings at
High, Medium, and Low. When the log set is rst
turned on, the ame will come on at the highest
setting. The log set will remember the last ame
setting used and in later use the ame brightness
will start at that setting, unless power to the unit
has been interrupted. Each time the ame button
is pressed, the ame brightness decreases. The
only way to turn off the ame effect completely is
to turn off the main power button (1).
4. Timer Button: This button controls the ON/OFF
and 8-time setting from 1 H to 8 H. When the
Timer is rst turned on, it will come on at the
shortest time setting (1 H). Each time the Timer
button is pressed, the time increases 1 hour,
up to the longest setting (8 hours). Once the
set time expires, all replace functions will be
automatically turned off.
5. Fahrenheit/Celsius Display: This button displays F
(Fahrenheit) or C (Celsius) depending on how the
temperature mode is set. When the replace is
turned on, the Fahrenheit (F) temperature will be
displayed. To switch from Fahrenheit to Celsius, or
vise-versa, when the HEATER is ON, hold HEATER
CONTROL button for 10 seconds. The replace
will remember the last temperature mode
setting, and in later use, the display will start at
that setting, unless power to the unit has been
interrupted.
6. Temperature/Timer Display: This LED display
shows the set point for the temperature and
timer functions. When either of these functions
is activated, the display reects the set point
for ve seconds and then fades to black. Any
change in the set point of the temperature or
timer will reactivate the display, which again
fades after ve seconds.
6 145 32
1
4
3
2
8
Maintenance
DANGER: Disconnect power before servicing.
WARNING: Any electrical re-wiring of this appliance must be done by a qualied electrician. This
wiring must be done in accordance with local codes and/or in Canada with the current CSA C22.1
Canadian Electrical Code, and for US installations, the National Electrical Code ANSI/NFPA NO 70.
WARNING: If repairing or replacing any electrical component or wiring, the original wire routing, color
coding and securing locations must be followed.
GLASS INFORMATION
1. Under no circumstances should this product be operated with a broken or chipped glass panel.
2. Do not strike or slam the glass.
3. Do not use abrasive cleansers to clean the glass. Make sure the glass is cool to the touch.
4. This product uses tempered glass. Replacement of the glass supplied by the manufacturer should be done
by qualied/authorized service personnel only.
MAINTENANCE OF MOTORS
1. Always disconnect the appliance from the main power supply and allow it to cool before any servicing
operation.
2. The motors used on the fan heater and ame blower are pre-lubricated for extended bearing life and
require no further lubrication. However, periodic cleaning/vacuuming of the appliance around the air
intake and exhaust, as well as the fan heater is reccomended. For heavy or continous use, periodic
cleaning must be done more frequently. If the heater blows alternating cold and warm air, check the fan
for free movement and for debris restricting air ow. If the fan does not move freely, the unit be turned off
and fan replaced immiediately in order to prevent further damage to the unit.
REMOTE CONTROL INFORMATION
The infrared remote control relies on a line of sight and must be
pointed at the ame/screen of the replace to work. The remote
control unit has the controls required to turn ON/OFF both the main
power and the heater. If you prefer to use the touchpad control on
the replace unit itself, open the control panel sliding cover to access
the touchpad buttons. The layout of the buttons on touchpads and
remote control unit can be seen on the previous page.
The plastic tab inside the battery
compartment MUST be removed
before the remote control will operate.
(Pull Tab)
9
Maintenance (continued)
Circuit Diagram
Care and Cleaning
DANGER: Disconnect power before servicing.
1. Always turn the heater OFF and unplug the power cord from the outlet before cleaning.
2. Cleaning of the control panel, located in the upper right-hand corner of the replace is to be done only
using a soft cloth, slightly dampened in water (if needed, a small amount of dish soap can be added to
the water) and dried using a clean, dry soft cloth. Cleaning of the screen diffuser is to be done using only
water and lint free cloth. DO NOT use any abrasive on the controls or the diffusing screen.
BATTERY REPLACEMENT
Please dispose of the used battery per municipal or provincial/state law.
BATTERY REPLACEMENT PROCEDURE: (SIZE CR2025)
THIS PRODUCT CONTAINS BATTERIES. IF SWALLOWED,
IT COULD CAUSE SEVERE INJURY OR DEATH IN JUST 2
HOURS. SEEK MEDICAL ATTENTION IMMEDIATELY.
Battery replacement instruction
CR2025
OPEN
PUSH
RELEASE
10
Troubleshooting
PROBLEM POSSIBLE CAUSE SOLUTION
The replace does
not operate.
The replace is not plugged in.
A circuit breaker is tripped or a fuse blown.
The ON/OFF switch is defective.
There is loose wiring.
Make sure the replace is plugged in to a standard
120V outlet.
Check additional appliances on the circuit; ideally
the replace should be on a dedicated 15-amp
circuit.
Call customer service.
Call customer service.
The power light is
ON but the ame
effect is not visible.
The replace is not operating correctly.
Light bulbs are not functioning.
Loose wiring
Refer to the operating instructions.
Refer to Replacing the Light Bulbs
Call customer service.
The heater is not
operating.
Incorrect operation.
The heater switch is defective.
The heater assembly is defective.
There is loose wiring.
The vents are dirty or clogged.
Refer to the operating instructions.
Call customer service.
Call customer service.
Call customer service.
Unplug the unit. Clear the vent area of dust and
debris. Wait ten minutes, plug the unit in again and
turn on the heater
There is excessive
noise when the
heater is operating.
Dirty or clogged blower.
The heater assembly is defective.
Refer to Maintenance of Motors in Care and Maintenance.
Call customer service.
The power light is
ON but the ember
bed ame is not
ickering.
Light bulbs are not functioning.
Loose wiring.
Refer to Replacing the Light Bulbs
Call customer service.
There is excessive
noise when the
ame is ON but the
heater is OFF.
The rotating ame reector shaft rubbing
against the housing.
The ame reector shaft motor is defective.
Open the back of the rebox and reposition
the ame reector shaft. Turn off the unit prior to
servicing.
Call customer service.
11
Service Parts
Muskoka
®
is a registered trademark of GHP Group Inc.
1-877-447-4768 •
www.ghpgroupinc.com
Part Description Part #
10 Flame Reflector EF23900008AC
11 Logset EF23900009AC
12 Heater EF23800001AC
13 Synchronous Motor EF27900015AC
14 Power Cord & Connector EF27900016AC
15 Main Board EF27900017AC
16 Flame - LED EF23900012AC
17 Embedded - LED Strip EF27900019AC
18 Control Panel Circuit Board EF27900020AC
19 Remote Control EF33510AS-15
Part Description Part #
1 Top Panel EF23900001AC
2 Left Side Panel Assembly EF23900002AC
3 Right Side Panel Assembly EF23900003AC
4 Back Panel EF23900004AC
5 Trim Assembly EF23900005AC
6 Flame Panel EF23900006AC
7 Screen EF23900007AC
8 Handle EF27900010AC
9 Control Panel EF27900011AC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

Muskoka 234-05-200-KIT User manual

Category
Fireplaces
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI