Tripp Lite SmartOnline, 3kVA Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
SmartOnline
Rack/Tower On-Line UPS Systems
Copyright © 2011 Tripp Lite. All rights reserved. SmartOnline
is a trademark of Tripp Lite.
Warranty
Registration:
register online today for a chance
to win a FREE Tripp Lite product—
www.tripplite.com/warranty
Not suitable for mobile applications.
1. Important Safety Instructions 2
2. Installation 3
2.1 Mounting (Rack) 3
2.2 Mounting (Tower) 4
2.3 Connection and Start-Up 4
2.4 Optional Connections 5
3. Operation 8
3.1 Front Panel Switches 8
3.2 Advanced Operational Settings 8
3.3 Front Panel Indicator Lights 9
3.4 Rear Panel 11
3.5 Communications 12
4. Troubleshooting 13
5. Battery Replacement 14
6. Storage and Service 16
6.1 Storage 16
6.2 Service 16
7. Warranty Registration 17
Español 18
Français 35
Pyññêèé 52
201102139 93-2882.indb 1 3/30/2011 10:04:10 AM
2
1. Important Safety Instructions
UPS Location Warnings
• InstalltheUPSsystemindoors,awayfromexcessmoistureorheat,conductive
contaminants,dustordirectsunlight.
• Forbestperformance,keeptheindoortemperaturebetween32ºFand104ºF
(0ºCand40ºC).
• LeaveadequatespacearoundallsidesoftheUPSsystemforproperventilation.
• DonotmounttheUPSsystemwithitsfrontorrearpanelfacingdown(atanyangle).
MountinginthismannerwillseriouslyinhibittheUPSsystem’sinternalcooling,
eventuallycausingproductdamagenotcoveredunderwarranty.
UPS Connection Warnings
• ConnecttheUPSsystemdirectlytoaproperlygroundedACpoweroutlet.Theoutlet
mustbeinstalledneartheUPSsystemandmustbeeasilyaccessiblefordisconnection.
• Toreducetheriskoffire,connectonlytoacircuitprovidedwith20amperesmaximum
branchcircuitovercurrentprotectioninaccordancewithyourlocalandNational
ElectricalCode(NEC),ANSI/NFPA70.
• DonotmodifytheUPSsystem’splug,anddonotuseanadapterthatwouldeliminate
theUPSsystem’sgroundconnection.DonotplugtheUPSsystemintoitself;thiswill
damagetheUPSsystem.
• DonotuseextensioncordstoconnecttheUPSsystemtoanACoutlet.
• IftheUPSsystemreceivespowerfromamotor-poweredACgenerator,thegenerator
mustprovideclean,filtered,computer-gradeoutput.
Equipment Connection Warnings
• Useofthisequipmentinlifesupportapplicationswherefailureofthisequipmentcan
reasonablybeexpectedtocausethefailureofthelifesupportequipmentorto
significantlyaffectitssafetyoreffectivenessisnotrecommended.Donotusethis
equipmentinthepresenceofaflammableanestheticmixturewithair,oxygenornitrous
oxide.
• DonotconnectsurgesuppressorsorextensioncordstotheoutputoftheUPSsystem.
ThismightdamagetheUPSsystemandmayaffectthesurgesuppressorandUPSsystem
warranties.ConnectingaTrippLitepowerdistributionunit(PDU)totheoutputofthe
UPSsystemissafeandwillnotvoidthewarranty.
Battery Warnings
• RefertoSection 5: Battery Replacementforacompletelistofbatterywarnings.
SAVE THESE INSTRUCTIONS
Thismanualcontainsinstructionsandwarningsthatshouldbefollowedduringthe
installation,operationandstorageofthisproduct.Failuretoheedthesewarningsmay
affectthewarranty.
201102139 93-2882.indb 2 3/30/2011 10:04:10 AM
3
2. Installation
1
Theincludedplasticpegs
A
willsupportthe
emptyrackmountshelves
B
untilthe
permanentmountinghardwareisinstalled.
Insertapegnearthecenterofthefrontand
rearbracketofeachshelfasshown.(Each
frontbrackethas6holesandeachrear
brackethas3holes.)Thepegswillsnapinto
place.
Afterinstallingthepegs,expandeachshelf
tomatchthedepthoftheverticalrackrails.
Thepegswillfitthroughthesquareholesin
therackrailstosupporttheshelves.Confirm
thattheshelvesarelevelinalldirections.
Note: The support ledge of each shelf must
face inward.
2
Securetheshelves
B
totherackrails
permanentlyusingthelongerincluded
screwsandwashers
C
asshown.(Place4
screwsatthefrontand4screwsattheback.)
Tightenallscrewsbeforeproceeding.
Warning: Do not attempt to install the UPS
system until the required screws have been
inserted and tightened. The plastic pegs will
not support the weight of the UPS system.
3
Attachthemountingbrackets
D
tothe
forwardmountingholesoftheUPSsystem
usingtheshorterincludedscrews
E
.The
mountingbracketearsmustfaceforward.
4
Withtheaidofanassistant,lifttheUPS
systemandslideitontothemounting
shelves.Insert4oftheincludedscrews
F
throughthemountingbracketearsandinto
theverticalrackrails.Tightenallscrews
securely.
• UsetheincludedrackmountshelvesandmountinghardwaretomounttheUPSsystemina
4-postrackorrackenclosure.TomounttheUPSsystemina2-post(telecom)rack,order
TrippLite’s2-PostRackmountKit(model2POSTRMKITWM,soldseparately).
• Theinstructionsinthismanualareforcommonrackandrackenclosuretypesandmaynot
beappropriateforallmountingapplications.Theusermustdeterminethefitnessof
hardwareandproceduresbeforemounting.Ifhardwareorproceduresarenotsuitablefor
theapplication,contactthemanufactureroftherackorrackenclosureforasolution.
Warning: The UPS system is very heavy—be careful when moving or lifting it.
4-Post Mounting Procedure
1
2
3
D
D
E
E
4
F
F
2.1 Mounting (Rack)
C
B
C
B
A
B
B
A
201102139 93-2882.indb 3 3/30/2011 10:04:14 AM
4
1
2
2. Installation
(
continued
)
TheUPSsystemcanbemountedinanupright
towerpositionwhenusedwithTrippLite’s
optionalbasestandkit(model2-9USTAND,
soldseparately).WhenmountingtheUPS
systeminatowerposition,makesurethecontrol
panelisclosertothetopofthecabinetthanthe
bottom.
Thecontrolpanelcanberotatedtomatchthe
orientationoftheUPSsystem.Pullthepanel
out,rotateitandpushitbackintoplaceas
shown.
Warning: The UPS system is very heavy—be
careful when moving or lifting it.
1
Plug the UPS system into an
electrical outlet.
Note: The UPS system does not include an
input power cord.
Connectauser-suppliedpowercordtothe
IEC-320-C20inputreceptacle.Thepower
cordshouldhaveanIEC-320-C19connector
ononeendandaplugappropriateforyour
localsite’sutilityoutletontheotherend.
TheUPSsystemmustbeconnectedtoa
dedicatedcircuitofsufficientamperage.
RefertotheUPSsystemnameplateforinput
requirements.
AftertheUPSsystemispluggedin,the
followingsequenceofeventswilloccur:
1. ThefanwillturnonandallLEDswill
illuminatemomentarily.
2. ThepercentlevelLEDs(25%,50%,
75%and100%)willilluminateoneata
time.
3. The“LINE”and“LOAD”LEDswill
illuminatetoindicatenormaloperation.
Note: Power will not be supplied to the
outlets until the UPS system is turned on.
Some models may differ.
1
2.3 Connection and Start-Up
2.2 Mounting (Tower)
Voltage Selection Mode
Pleasefollowbelowproceduretoselecttheoutput
voltagebyfrontpanel.
1. PresstheON/TESTandOFFbuttons
simultaneouslytoenter“VoltageSelection”
mode.ThethreeLEDslabeledVOLTAGE
SELECTIONMODEwillflashwhenyouhave
enteredthismode.
2. PresstheON/TESTbuttontoselecttheoutput
voltagefrom200to240.
3. Afterselectingthedesiredoutputvoltage,press
theON/TESTandOFFbuttonssimultaneously
tosaveyourselectionandexit“Voltage
Selection”mode.
201102139 93-2882.indb 4 3/30/2011 10:04:16 AM
5
2. Installation
(
continued
)
2
3
Some models may differ.
2.3 Connection and Start-Up
(
continued
)
Voltage Note: The UPS system supports a
nominal AC voltage setting of 200V, 208V,
220V, 230V or 240V. 230V is the factory
default setting. The full output capacity of
2,500 watts is available when the UPS
system is set at 230V or 240V. When the
UPS system is set at 200V, 208V or 220V,
output capacity is reduced to 2,400 watts.
The nominal voltage setting can be
changed using the control panel buttons,
with PowerAlert software or the optional
SNMPWEBCARD internal accessory card.
See the PowerAlert software or
SNMPWEBCARD documentation for
more information about changing the
nominal voltage setting.
2
Plug equipment into the UPS
system’s AC outlets.
Note: Use the supplied C13 to C14
interconnection cord.
TheUPSsystemisdesignedtosupport
computerequipmentonly.TheUPSsystem
willbecomeoverloadedifhousehold
appliancesorlaserprintersareconnectedto
its outlets.
Note: Additional interconnection cords
(C13 to C14) are available from Tripp Lite.
Visit www.tripplite.com. (Part # P004-006)
3
Turn the UPS system ON.
ToturnontheUPSsystem,pressthe“ON/
TEST”buttonforapproximately1second
untiltheUPSsystembeeps,thenreleasethe
button.
TheUPSsystemwillbeginprovidingACpowertoits
outlets.The“ONLINE”LEDwillilluminate.
Note: UPS system will function properly upon
initial startup, however, maximum runtime for the
unit’s battery will only be accessible after it has
been charged for 24 hours.
TheUPSsystemwillfunctionproperlywithouttheseconnections.*
* Note: PowerAlert software (included) or the optional SNMPWEBCARD internal
accessory card is required to control some of the advanced features of the UPS system,
including economy mode and frequency conversion settings. The factory defaults are
suitable for most applications.
2.4 Optional Connections
201102139 93-2882.indb 5 3/30/2011 10:04:16 AM
6
4-5
2. Installation
(
continued
)
2a
Some models may differ.
2b
USB and RS-232 Serial
Communications
UsetheincludedUSBcable(see
1a
)or
RS-232(DB9)serialcable(see
1b
)to
connecttheUPSsystem’scommunication
porttoacomputer’scommunicationport.
InstalltheincludedPowerAlertsoftwareon
thecomputer.(SeethePowerAlertsoftware
documentationforsystemrequirementsand
installationinstructions.)
EPO Port Connection
Thisoptionalfeatureisonlyforthose
applicationsthatrequireconnectiontoa
facility’sEmergencyPowerOff(EPO)
circuit.WhentheUPSisconnectedtothis
circuit,itenablesemergencyshutdownof
theUPS’sinverterandinhibitstransferto
internalbypass.Usingthecableprovided,
connecttheEPOportofyourUPS(see
2a
)
toauser-suppliednormallyclosedor
normallyopenswitchaccordingtothe
circuitdiagram(see
2b
).
Note:
1. If using a cable other than what is
supplied, the cable should not have a
resistance of greater than 5 ohms.
2. If a non-latching EPO switch is used,
the EPO must be held for a minimum
of 1 second. This does not apply to a
latching EPO switch.
CAUTION: The EPO port is not a phone
line surge suppressor; do not connect a
phone line to this port.
2.4 Optional Connections
(
continued
)
2
1
1b
Some models may differ.
1a
Some models may differ.
201102139 93-2882.indb 6 3/30/2011 10:04:17 AM
7
3
4
Some models may differ.
Some models may differ.
3
4
2. Installation
(
continued
)
2.4 Optional Connections
(
continued
)
UPSUnitStatewhenassertingEPOwithAClinepresent:
LEDs Output Fans Serial SNMP USB
OFF OFF ON ON ON ON
TorestarttheUPSunitafterassertingEPOwithAClinepresent:
1. VerifythattheEPOassertionhasbeenremovedorcleared.
2. RemoveAClinepowertotheUPSunit.
3. ReapplyAClinepower.NowtheUPSwillstartbackupinStandbymode.
UPSUnitStatewhenassertingEPOwithoutAClinepower:
LEDs Output Fans Serial SNMP USB
OFF OFF OFF OFF OFF OFF
TorestarttheUPSunitafterassertingEPOwithoutAClinepower:
1. VerifythattheEPOassertionhasbeenremovedorcleared.
2. ReapplyAClinepowertotheUPSunit.NowtheUPSwillstartbackupinStandbymode.
External Battery Connection
Accessory Card Slot
Theslotaccommodatesanoptionalinternal
accessorycard(modelSNMPWEBCARDor
RELAYIOCARD,soldseparately).
SNMPWEBCARDprovidesanEthernet
networkinterfaceforremotemonitoringand
controloftheUPSsystemviaSNMP,Webor
telnet.SNMPWEBCARDenablesremote
reboots,shutdowns,loadmonitoring,
conditionreportingandmore.Use
SNMPWEBCARDwithanoptional
environmentalsensor(model
ENVIROSENSE,soldseparately)tomonitor
temperatureandhumidityortocontroland
monitoralarmsandsecuritysystems.
RELAYIOCARDprovidesaprogrammable
contactclosureinterfacewith8outputsand1
input.
Removethecoverpanelfromtheslotto
inserttheaccessorycard.Refertothe
SNMPWEBCARDorRELAYIOCARD
documentationforadditionalinstallation
instructions.
201102139 93-2882.indb 7 3/30/2011 10:04:18 AM
8
3. Operation
“ON/TEST” Button:Thisbuttoncontrols4separatefunctions:
UPS System Power ON
ToturnontheUPSsystem,pressthe“ON/TEST”buttonfor
approximately1seconduntiltheUPSsystembeeps,thenreleasethe
button.The“ONLINE”LEDwillilluminate.
UPS System Self-Test
Toinitiateaself-testofthebatteryduringnormalon-lineoperation,
pressthisbuttonforapproximately1seconduntiltheUPSsystem
beeps,thenreleaseit.TheUPSsystemwillshifttobatterypowerfor
10seconds.Note: All LEDs illuminate during a self-test.
Alarm Silence
TosilencetheUPSsystem’sonbatteryalarm,pressthisbuttonand
holdituntiltheUPSsystembeeps,thenreleasethebutton.
UPS System Cold Start
TousetheUPSsystemasastand-alonepowersourcewhenAC
powerisunavailable(i.e.duringablackout),pressthisbuttonand
holdituntiltheUPSsystembeeps,thenreleasethebutton.TheUPS
systemwillthenprovidebatterypowertoitsoutlets.
*
* The “ON BATT” indicator light will be illuminated since the UPS system will be
operating from battery power.
“OFF” Button:ThisbuttonturnsoffpowertotheUPSsystem’s
outlets.PressthisbuttonandholdituntiltheUPSsystembeeps,
thenreleaseit.Thebatterywillcontinuetochargeandthefanwill
continuetooperateevenwhentheoutletsareoff.ToturntheUPS
systemoffcompletely,includingthebatterycharger,unplugtheUPS
system’spowercordafterpressingthe“OFF”switch.
3.1 Front Panel Switches
3.2 Advanced Operational Settings
Economy Mode
TheUPSsystemsupportseconomymodeoperationtoreduceenergyconsumptionandBTU
emissions.Ineconomymode,theUPSsystemoperateswithincreasedefficiencywhenthe
qualityofutilitypowerissatisfactorytopassthroughtoconnectedequipmentwithoutdouble
conversion.
Economymodesavesenergybysuspendingdoubleconversionwhenincomingvoltageis
within-12%/+10%ofthenominalvoltagesetting.Ifthenominalvoltagesettingis230V,the
UPSsystemwillremainineconomymodewhileutilitylinevoltageisbetweenapproximately
202Vand253V.Ifutilitylinevoltagefallsoutsidethisrange,theUPSsystemwilleither
switchbacktostandardon-line,doubleconversionmodeoritwillswitchtobatterybackup
mode,dependingontheseverityofthevoltagedeviation.
(continued)
201102139 93-2882.indb 8 3/30/2011 10:04:18 AM
9
Economymodecanbeenabled(ordisabled)throughtheincludedPowerAlertsoftwareorthe
optionalSNMPWEBCARDinternalaccessorycard.TheUPSsystem'syellow“BYPASS”
LEDwillilluminatecontinuouslywheneconomymodeisenabled.RefertothePowerAlert
orSNMPWEBCARDdocumentationformoreinformation.
On-line, double-conversion mode (default)
Typicallineefficiencyatfullload:89%
Outputvoltagerange:± 2%ofnominalsetting(200/208/220/230/240V)
Economy mode
Typicallineefficiencyatfullload:97%
Outputvoltagerange:-12%/+10%ofnominalsetting(200/208/220/230/240V)
Frequency Conversion
TheUPSsystemautomaticallyselects50Hzor60Hzoperationbasedonutilitypower
conditionsatstart-upandregulatesoutputpowerwithin± 0.05Hzoftheselectedfrequency.
TheUPSsystemalsohasanadvancedsettingthatallowscontinuousfrequencyconversion
from50Hzto60Hzorfrom60Hzto50Hz.Theadvancedfrequencyconversionsettingis
accessiblethroughtheincludedPowerAlertsoftwareortheoptionalSNMPWEBCARD
internalaccessorycard.Whencontinuousfrequencyconversionisenabled,themaximum
outputcapacityoftheUPSsystemisderatedby25%.
3.2 Advanced Operational Settings
(
continued
)
3. Operation
(
continued
)
3.3 Front Panel Indicator Lights
“ON LINE” LED:ThisgreenLEDwillilluminatecontinuouslyto
indicatetheUPSsystemisoperatingnormallyinon-linemode
(filteringandresynthesizingAClineinputtoprovidepuresinewave
output).WhenthisLEDisilluminated,theloadleveloftheUPS
systemisdisplayedonthe%levelLEDs(25%,50%,75%,100%).
“LINE” LED:ThisgreenLEDwillilluminatecontinuously to
indicatetheutility-suppliedAClinevoltageatthewalloutletis
nominal.Itwillflashifthelinevoltageisoutsidethenominalrange
(eithertoolowortoohigh).Useractionisnotrequiredwhenthe
LEDflashes;theUPSsystemcontinuouslyandautomaticallyfilters
AClinepowertoprovideequipmentwithpuresinewaveACpower,
regardlessofbrownoutorovervoltageconditions.IfthisLEDisoff,
thenAClinevoltageisnotpresent(blackout)orisatanextremely
highvoltage,andtheUPSsystemwillprovideconnectedequipment
withpowerfromitsbatterysystem.
Note: All LEDs illuminate during a UPS system self-test.
201102139 93-2882.indb 9 3/30/2011 10:04:18 AM
10
3. Operation
(
continued
)
“BYPASS” LED:ThisyellowLEDwillilluminatecontinuously
whentheUPSsystemisineconomymode.TheLEDwillflashwhen
theUPSsystemisbypassmode,indicatingthattheUPSsystem’s
DC/ACinverterisdeactivated.Thered“FAULT”LEDwillalso
illuminateiftheUPSsystemisinbypassmode.Duringnormal
operationthebypassLEDwillilluminatebrieflywhentheunitis
pluggedin.Ifaninternalfaultoroverloadoccurs,theLEDwill
flashrepeatedlytoshowthatconnectedequipmentwillreceive
filteredAClinepower,butwillnotreceivebatterypowerduringa
blackout.Inthiscase,contactTrippLiteforservice.
“FAULT” LED:ThisredLEDwillflashwhentheUPSsystem
detectsaninternalfault.Iftheconditionpersistsafterrestartingthe
UPSsystem,seeSection 4: Troubleshooting.
“LOAD” LED:ThisgreenLEDwillilluminatewhentheUPS
systemisreceivingACpower.Italsoindicatesthatthe%level
LEDs(25%,50%,75%,100%)aredisplayingtheUPSloadlevel.
“BATT” LED:ThisgreenLEDwillilluminatewhentheUPS
systemisoperatingfrombatterypower.Itindicatesthatthe%level
LEDs(25%,50%,75%,100%)aredisplayingthebatterycharge
level.(The“ONBATT”LEDwillalsobeilluminated.)
% Level LEDs: Thesedual-functionLEDswillindicatethe%level
foreithertheloadlevel(ifthe“LOAD”LEDislit)orthebattery
chargelevel(ifthe“BATT”LEDislit).
“OVERLOAD” LED:ThisredLEDwillilluminatecontinuously to
indicatethattheUPSsystem’scapacityhasbeenexceeded.TheUPS
alarmwillbeepcontinuously.Immediatelyunplugsomeequipment
untiltheLEDandalarmgooff.Iftheoverloadisnotcorrected
immediately,theUPSsystemwillgofromon-linetobypassmode.
“BATT LOW” LED:ThisyellowLEDwillilluminatewhentheUPS
system’sbatterychargelevelislow.TheUPSalarmwillbeepuntil
thebatteriesareeitherdepletedoradequatelyrecharged.
“ON BATT” LED:ThisgreenLEDwillilluminatecontinuously to
indicatethatAClinevoltageisabsent(oroutofrange)andtheUPS
systemisprovidingequipmentwithbattery-derivedACpower.The
UPSsystemwillalsobeepevery2seconds(unlesssilencedbythe
“ON/TEST”button)andthe%levelLEDs(25%,50%,75%,100%)
willdisplaythebatterychargelevel.
“REPLACE BATT” LED:ThisredLEDwillilluminate
continuouslyandtheUPSalarmwillbeepevery2secondsifthe
UPSsystemfailstheautomaticself-test.AllowtheUPSsystemto
chargeforatleast12hoursandperformaself-testasdescribedin
Section 3.1: Front Panel Switches.Iftheconditionpersists,contact
TrippLite.
3.3 Front Panel Indicator Lights
(
continued
)
201102139 93-2882.indb 10 3/30/2011 10:04:19 AM
11
IEC-320-C20
CONTROLLABLE LOAD 1
CONTROLLABLE LOAD 2 UNSWITCHED
3. Operation
(
continued
)
Accessory Card Slot:Removethecoverpanelfromthisslotto
installanoptionalinternalSNMPWEBCARDorRELAYIOCARD
accessory,soldseparately.SNMPWEBCARDprovidesanetwork
interfaceformonitoringandcontrolviaSNMP,Webortelnet,
enablingremotereboots,shutdownsandmore.RELAYIOCARD
providesaprogrammablecontactclosureinterfacewith6outputs
and1input.
External Battery Pack Connector
(Configuration Varies By Model)
Fan:ThefancoolstheUPSsystem’sinternalcomponents.Itis
alwaysonwhenlinepowerispresent,evenifpowertotheUPS
system’soutletsisturnedoff.
Input Power Cord:ThisUPSsystemrequiresauser-suppliedpower
cord.ThispowercordshouldhaveanIEC-320-C19connectoron
oneendandaplugappropriateforyourlocalsite'sutilityoutleton
theotherend.
AC Outlets (Configuration Varies By Model): Theseoutlets
provideconnectedequipmentwithpuresinewaveACoutputderived
fromtheAClineduringnormaloperationandderivedfrombattery
powerduringblackoutsandseverebrownoutsorovervoltages.
Outputpowerisfilteredtoprotectconnectedequipmentagainst
damagingsurgesandlinenoise.
Theoutletsaredividedintonumberedloadbanks,aslabelledonthe
unit.UsingincludedPowerAlertsoftwareandcablingoranoptional
SNMPWEBCARD,loadbanksmaybeindividuallyturnedoffand
onfromaremotelocation,allowinguserstoresetorreboot
connectedequipment.
3.4 Rear Panel
IEC-320-C13
IEC-320-C19
201102139 93-2882.indb 11 3/30/2011 10:04:21 AM
12
RS-232 (DB9)
3. Operation
(
continued
)
Communication Ports (USB and/or RS-232): Theseportsconnect
theUPSsystemtoacomputer.UsewithTrippLite’sPowerAlert
softwareandincludedcablingtoallowthecomputerto
automaticallysaveopenfilesandshutdownduringablackout.Also
usePowerAlertsoftwaretocontrolUPSsystemloadbanksand
monitorawidevarietyofAClinepowerandUPSsystemoperating
conditions.SeeSection 2.4: Optional Connections for cable
connectioninstructions.RefertothePowerAlertdocumentationfor
softwareinstallationinstructions.
TheRS-232portcanalsobeusedasacontactclosureport.The
port’snumberedpinassignmentsareshownintheRS-232(DB9)
illustrationatleft.Ifthebatterychargelevelislow,theUPSsystem
willbridgepins1and5.Ifutilitypowerfails,theUPSsystemwill
bridgepins8and5.ToshutdowntheUPSsystemremotely,short
pin3~pin9foratleast3.8seconds.
EPO (Emergency Power Off) Port: TheUPSsystemhasanEPO
portthatmaybeusedtoconnecttheUPSsystemtoacontact
closureswitchtoenableemergencyUPSsystemshutdown.See
Section 2.4: Optional Connectionsformoreinformation.Iftheunit
hasbeenshutdownduetoanEPOevent,itwillbenecessaryto
disconnecttheunitfromutilitypowertoresettheunit.After
re-connectingtoutilitypower,seesection2.3Installationforstart-
up instructions.
3.5 Communications
USB
201102139 93-2882.indb 12 3/30/2011 10:04:21 AM
13
4. Troubleshooting
13
TheUPSsystemcontrolpanelLEDswillilluminateinthesequenceslistedbelowtoindicate
operational problems. Note: If the “FAULT” LED illuminates, determine the specific
fault condition by activating the error code LEDs. To activate the error code LEDs,
press the “ON/TEST” button until the UPS system beeps, then release the button. The
error code LEDs will illuminate for 5 seconds.
Illuminated LEDs Condition and Solution
On: REPLACE BATT
Error Code LEDs: Not Applicable
Replace Battery: Allow the UPS system to charge for at least
12 hours and perform a UPS system self-test as described
in Section 3.1: Front Panel Switches. If the LED remains on,
contact Tripp Lite for service.
Flashing: LINE
Error Code LEDs: Not Applicable
Input Abnormal: Utility power voltage or frequency is too high
or too low for the UPS system to operate in BYPASS mode.
If an inverter failure occurs, the UPS system will not pass
through utility power to the outlets and any connected equip-
ment will turn off.
On: FAULT
Error Code LEDs: 50% 100%
Battery Weak: Allow the UPS system to charge for 12 hours. If
the LED remains on, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: 25% 75%
Inverter Over-Current: Reduce the load supported by the
UPS system by unplugging some equipment. Restart the UPS
system. If the problem persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: 25% 75% 100%
Internal Temperature Too High: Confirm that adequate space
exists for air to circulate near the UPS system’s vents. Confirm
that the UPS system’s fan is working properly. Confirm that the
ambient temperature does not exceed recommended levels.
Restart the UPS system.
On: FAULT
Error Code LEDs: 25% 50%
Inverter Overload: Reduce the load supported by the UPS
system by unplugging some equipment.
On: FAULT
Error Code LEDs: 25% 50% 100%
Charger Out of Order: Restart the UPS system. If the problem
persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: 25% 50% 75%
Fan Out of Order: Restart the UPS system. If the problem
persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: 25% 50% 75% 100%
Bypass Phase Can’t Lock: Restart the UPS system. If the
problem persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: BATT 25%
Utility Voltage Low and Battery Disconnected at
Initialization: Shut down the UPS system. Check the internal
battery connections. Correct the AC input voltage. Restart
the UPS system. If the problem persists, contact Tripp Lite for
service.
On: FAULT
Error Code LEDs: BATT 25% 100%
Battery Disconnected at Initialization and Utility Voltage
or Frequency Too High or Too Low in On-Line Mode: Shut
down the UPS system. Check the internal battery connections.
Correct the AC input voltage. Restart the UPS system. If the
problem persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: BATT 25% 75%
Input Over-Current: Reduce the load supported by the UPS
system by unplugging some equipment. Restart the UPS
system. If the problem persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: BATT 25% 50%
Bypass Overload: Reduce the load supported by the UPS
system by unplugging some equipment. Either wait for the
UPS system to recognize the load reduction or restart the UPS
system. If the problem persists, contact Tripp Lite for service.
On: FAULT
Error Code LEDs: BATT 25% 50% 100%
Battery Voltage Too High: Restart the UPS system. If the
problem persists, contact Tripp Lite for service.
Note: All other error codes indicate internal fault conditions. Restart the UPS system. If the problem
persists, contact Tripp Lite for service.
201102139 93-2882.indb 13 3/30/2011 10:04:21 AM
14
5. Battery Replacement
Undernormalconditions,theoriginalbatteriesintheUPSsystemwilllastseveralyears.The
batteriesaredesignedforhot-swapreplacement (i.e.replacementwhiletheUPSsystemisin
ONmode),butsomequalifiedservicepersonnelmaywishtoputtheUPSsysteminOFF
modeanddisconnectequipmentbeforeproceeding.
Battery Warnings
• Caution: Therearenouser-serviceablepartsinsidetheUPSsystem.Batteryserviceor
replacementmustbeperformedorsupervisedbyqualifiedservicepersonnelfamiliarwith
batteriesandtherequiredprecautions.
• Caution: Whenreplacingbatteries,replaceonlywiththesametypeandnumberof
batteries.
• Batteriescanpresentariskofelectricalshockandburnfromhighshort-circuitcurrent.
Observeproperprecautions.Donotdisposeofthebatteriesinafire.DonotopentheUPS
orbatteries.Donotshortorbridgethebatteryterminalswithanyobject.Unplugandturn
offtheUPSbeforeperformingbatteryreplacement.Usetoolswithinsulatedhandles.There
arenouser-serviceablepartsinsidetheUPS.Batteryreplacementshouldbeperformedonly
byauthorizedservicepersonnelusingthesamenumberandtypeofbatteries(SealedLead-
Acid).Thebatteriesarerecyclable.Refertoyourlocalcodesfordisposalrequirementsor
visitwww.tripplite.com/UPSbatteryrecyclingforrecyclinginformation.TrippLiteoffersa
completelineofUPSSystemReplacementBatteryCartridges(R.B.C.).VisitTrippLiteon
theWebatwww.tripplite.com/support/battery/index.cfmtolocatethespecificreplacement
batteryforyourUPS.
201102139 93-2882.indb 14 3/30/2011 10:04:21 AM
15
1
2
3
6
5
4
5. Battery Replacement
(
continued
)
Procedure
1
RemoveFrontPanel
2
RemoveBatteryCompartmentCover
3
DisconnectOldBatteries
andRemoveOldBatteries
4
InsertNewBatteriesandConnectNewBatteries(Attachbattery
connectorsblack-to-blackandred-to-red.)
5
ReplaceBatteryCompartmentCover
6
ReplaceFrontPanel
7
RecycleOldBatteries
7
201102139 93-2882.indb 15 3/30/2011 10:04:29 AM
16
6. Storage and Service
FirstturntheUPSsystemOFF:pressthe“OFF”switchtoturnpoweroffattheUPS
system’soutlets,thendisconnecttheUPSsystem’spowercordfromthewalloutlet.Next,
disconnectallequipmenttoavoidbatterydrain.IftheUPSsystemwillbestoredforan
extendedperiodoftime,rechargetheUPSsystem’sbatteriesfullyeverythreemonthsby
pluggingtheUPSsystemintoaliveACoutletandallowingtheUPSsystemtochargefor
4-6hours.IftheUPSsystem’sbatteriesareleftdischargedforanextendedperiodoftime,
theymaysufferapermanentlossofcapacity.
AvarietyofExtendedWarrantyandOn-SiteServiceProgramsarealsoavailablefrom
TrippLite.Formoreinformationonservice,visitwww.tripplite.com/support.Before
returningyourproductforservice,followthesesteps:
1.Reviewtheinstallationandoperationproceduresinthismanualtoinsurethattheservice
problemdoesnotoriginatefromamisreadingoftheinstructions.
2.Iftheproblemcontinues,donotcontactorreturntheproducttothedealer.Instead,visit
www.tripplite.com/support.
3.Iftheproblemrequiresservice,visitwww.tripplite.com/supportandclicktheProduct
Returnslink.FromhereyoucanrequestaReturnedMaterialAuthorization(RMA)
number,whichisrequiredforservice.Thissimpleon-lineformwillaskforyourunit’s
modelandserialnumbers,alongwithothergeneralpurchaserinformation.TheRMA
number,alongwithshippinginstructionswillbeemailedtoyou.Anydamages(direct,
indirect,specialorconsequential)totheproductincurredduringshipmenttoTrippLiteor
anauthorizedTrippLiteservicecenterisnotcoveredunderwarranty.Productsshippedto
TrippLiteoranauthorizedTrippLiteservicecentermusthavetransportationcharges
prepaid.MarktheRMAnumberontheoutsideofthepackage.Iftheproductiswithinits
warrantyperiod,encloseacopyofyoursalesreceipt.Returntheproductforserviceusing
aninsuredcarriertotheaddressgiventoyouwhenyourequesttheRMA.
6.1 Storage
6.2 Service
201102139 93-2882.indb 16 3/30/2011 10:04:29 AM
17
201102139 • 932882-EN
7. Warranty Registration
WARRANTY REGISTRATION
Visit www.tripplite.com/warranty today to register the warranty for your new Tripp Lite product. You’ll be
automatically entered into a drawing for a chance to win a FREE Tripp Lite product!*
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.
Regulatory Compliance Identification Numbers: For the purpose of regulatory compliance certifications and
identification, this Tripp Lite product has been assigned a unique series number. The series number can be
found on the product nameplate label, along with all required approval markings and information. When
requesting compliance information for this product, always refer to the series number. The series number
should not be confused with the marking name or model number of the product.
FCC Notice, Class A
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense. The user must use shielded cables and connectors with this equipment.
Any changes or modifications to this equipment not expressly approved by Tripp Lite could void the user’s
authority to operate this equipment.
WEEE Compliance Information for Tripp Lite Customers and Recyclers (European Union)
Under the Waste Electrical and Electronic Equipment (WEEE) Directive and implementing regulations, when
customers buy new electrical and electronic equipment from Tripp Lite they are entitled to:
• Send old equipment for recycling on a one-for-one, like-for-like basis (this varies depending on the country)
• Send the new equipment back for recycling when this ultimately becomes waste
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without
notice.
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
201102139 93-2882.indb 17 3/30/2011 10:04:29 AM
18
Manual del Propietario
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Sistemas UPS SmartOnline
en Rack/Torre 100% en Línea
Copyright © 2011 Tripp Lite. Todos los derechos reservados. SmartOnline es una marca comercial de Tripp Lite.
Noconvenienteparalosusosmóviles.
1. Instrucciones de Seguridad Importantes 19
2. Instalación 20
2.1 Instalación (Rack) 20
2.2 Instalación (Torre) 21
2.3 Conexión y Arranque 21
2.4 Conexiones Opcionales 22
3. Operación 25
3.1 Interruptores del Panel Frontal 25
3.2 Ajustes Operacionales Avanzados 25
3.3 Luces Indicadoras del Panel Frontal 26
3.4 Panel Posterior 28
3.5 Comunicaciones 29
4. Solución de Problemas 30
5. Reemplazo de Baterías 31
6. Almacenamiento y Reparaciones 33
6.1 Almacenamiento 33
6.2 Reparaciones 33
7. Garantía 34
English 1
Français 35
Pyññêèé 52
201102139 93-2882.indb 18 3/30/2011 10:04:29 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Tripp Lite SmartOnline, 3kVA Owner's manual

Category
Uninterruptible power supplies (UPSs)
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI