Friedrich QUIETMASTER 2009 Owner's manual

Category
Split-system air conditioners
Type
Owner's manual
Service Manual
Compact Programmable
CP-14-18-24-ServMan (04-09)
Models
2009
2008
FRIEDRICH AIR CONDITIONING CO.
Post Ofce Box 1540 · San Antonio, Texas 78295-1540
4200 N. Pan Am Expressway · San Antonio, Texas 78218-5212
(210) 357-4400 · FAX (210) 357-4490
www.friedrich.com
Printed in the U.S.A.
TECHNICAL SUPPORT
CONTACT INFORMATION
1
Table Of Contents
Important Safety Information ........................................................................................................................................ 2-4
Introduction ...................................................................................................................................................................... 4
Unit Identication ............................................................................................................................................................. 5
Electrical Data .............................................................................................................................................................. 6-7
Specications and Performance Data .......................................................................................................................... 8-9
Functional Components Denitions ............................................................................................................................... 10
Air Conditioner Use ........................................................................................................................................................ 10
How to Operate the Friedrich CP Room Air Conditioner ........................................................................................... 11-12
Refrigeration Sequence of Operation ............................................................................................................................. 13
Sealed Refrigeration System Repairs ....................................................................................................................... 14-17
Method of Charging/Repairs ........................................................................................................................................... 15
.
Metering Device ...............................................................................................................................................................18
Compressor Checks ...................................................................................................................................................18-22
Routine Maintenance ................................................................................................................................................. 23-24
Troubleshooting ......................................................................................................................................................... 25-28
Wiring Diagrams for 2009 Models .................................................................................................................................. 29
Wiring Diagrams for 2008 Models .................................................................................................................................. 30
Parts for 2009 Models ............................................................................................................................................... 31-34
Parts for 2008 Models ............................................................................................................................................... 35-37
Warranty ......................................................................................................................................................................... 38
IMPORTANT SAFETY INFORMATION
The information contained in this manual is intended for use by a qualied service technician who is familiar
with the safety procedures required for installation and repair, and who is equipped with the proper tools and
test instruments required to service this product.
Installation or repairs made by unqualied persons can result in subjecting the unqualied person making
such repairs as well as the persons being served by the equipment to hazards resulting in injury or electrical
shock which can be serious or even fatal.
Safety warnings have been placed throughout this manual to alert you to potential hazards that may be
encountered. If you install or perform service on equipment, it is your responsibility to read and obey these
warnings to guard against any bodily injury or property damage which may result to you or others.
PERSONAL INJURY OR DEATH HAZARDS
ELECTRICAL HAZARDS:
Unplug and/or disconnect all electrical power to the unit before performing inspections, •
maintenance, or service.
Make sure to follow proper lockout/tag out procedures.•
Always work in the company of a qualied assistant if possible. •
Capacitors, even when disconnected from the electrical power source, retain an electrical charge •
potential capable of causing electric shock or electrocution.
Handle, discharge, and test capacitors according to safe, established, standards, and approved •
procedures.
Extreme care, proper judgment, and safety procedures must be exercised if it becomes necessary •
to test or troubleshoot equipment with the power on to the unit.
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read
and obey all safety messages.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury,
and tell you what will happen if the instructions are not followed.
This is a safety Alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol with the word “WARNING”
or “CAUTION. These words mean:
You can be killed or seriously injured if you do not follow instructions.
You can receive minor or moderate injury if you do not follow instructions.
A message to alert you of potential property damage will have the
word NOTICE”. Potential property damage can occur if instructions
are not followed.
WARNING
CAUTION
NOTICE
2
Do not spray or pour water on the return air grille, discharge air grille, evaporator coil, control panel, •
and sleeve on the room side of the air conditioning unit while cleaning.
Electrical component malfunction caused by water could result in electric shock or other electrically •
unsafe conditions when the power is restored and the unit is turned on, even after the exterior is dry.
Never operate the A/C unit with wet hands.•
Use air conditioner on a single dedicated circuit within the specied amperage rating. •
Use on a properly grounded outlet only.•
Do not remove ground prong of plug.•
Do not cut or modify the power supply cord.•
Do not use extension cords with the unit.•
Follow all safety precautions and use proper and adequate protective safety aids such as: gloves, •
goggles, clothing, adequately insulated tools, and testing equipment etc.
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death. •
REFRIGERATION SYSTEM HAZARDS:
Use approved standard refrigerant recovering procedures and equipment to relieve pressure before •
opening system for repair.
Do not allow liquid refrigerant to contact skin. Direct contact with liquid refrigerant can result in minor •
to moderate injury.
Be extremely careful when using an oxy-acetylene torch. Direct contact with the torch’s ame or hot •
surfaces can cause serious burns.
Make sure to protect personal and surrounding property with re proof materials.•
Have a re extinguisher at hand while using a torch.•
Provide adequate ventilation to vent off toxic fumes, and work with a qualied assistant whenever •
possible.
Always use a pressure regulator when using dry nitrogen to test the sealed refrigeration system for •
leaks, ushing etc.
Make sure to follow all safety precautions and to use proper protective safety aids such as: gloves, •
safety glasses, clothing etc.
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death. •
MECHANICAL HAZARDS:
Extreme care, proper judgment and all safety procedures must be followed when testing, •
troubleshooting, handling, or working around unit with moving and/or rotating parts.
Be careful when, handling and working around exposed edges and corners of sleeve, chassis, and •
other unit components especially the sharp ns of the indoor and outdoor coils.
Use proper and adequate protective aids such as: gloves, clothing, safety glasses etc.•
Failure to follow proper safety procedures and/or these warnings can result in serious injury or death.•
3
4
PROPERTY DAMAGE HAZARDS
FIRE DAMAGE HAZARDS:
Read the Installation/Operation Manual for this air conditioning unit prior to operating.•
Use air conditioner on a single dedicated circuit within the specied amperage rating. •
Connect to a properly grounded outlet only.•
Do not remove ground prong of plug.•
Do not cut or modify the power supply cord.•
Do not use extension cords with the unit.•
Failure to follow these instructions can result in re and minor to serious property damage.•
WATER DAMAGE HAZARDS:
Improper installation maintenance, or servicing of the air conditioner unit, or not following the above •
Safety Warnings can result in water damage to personal items or property.
Insure that the unit has a sufcient pitch to the outside to allow water to drain from the unit. •
Do not drill holes in the bottom of the drain pan or the underside of the unit. •
Failure to follow these instructions can result in result in damage to the unit and/or minor to serious •
property damage.
INTRODUCTION
This service manual is designed to be used in conjunction with the installation manuals provided with each unit.
This service manual was written to assist the professional HVAC service technician to quickly and accurately
diagnose and repair any malfunctions of this product.
This manual, therefore, will deal with all subjects in a general nature. (i.e. All text will pertain to all models).
IMPORTANT:
It will be necessary for you to accurately identify the unit you are
servicing, so you can be certain of a proper diagnosis and repair.
(See Unit Identication.)
Cabinet
Airinlet louver
Front grille
Powercord
Control panelcover
Frontintakegrille
Airfilter
(behindfront intake grille)
Serial Number
Decade Manufactured
L=0 C=3 F=6 J=9
A=1 D=4 G=7
B=2 E=5 H=8
L H G K 00001
Production Run Number
Year Manufactured
A=1 D=4 G=7 K=0
B=2 E=5 H=8
C=3 F=6 J=9
Product Line
K = RAC
Month Manufactured
A=Jan D=Apr G=Jul K=Oct
B=Feb E=May H=Aug L=Nov
C=Mar F=Jun J=Sept M=Dec
3rd and 4th Digit - Approximate
BTU/HR (Cooling)
Heating BTU/Hr capacity listed in the
Specication/Performance Data Section
7th Digit – Options
0 = Straight Cool &
Heat Pump Models
6th Digit – Voltage
1 = 115 Volts
3 = 230-208 Volts
5th Digit
Alphabetical Modier
COMPACT
PROGRAMMABLE
Model Number Code
C P 08 E 1 0
RAC Serial Number Identication Guide
UNIT IDENTIFICATION
5
ELECTRICAL DATA
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation.
All electrical connections and wiring MUST be
installed by a qualied electrician and conform to
the National Electrical Code and all local codes
which have jurisdiction.
Failure to do so can result in personal injury or
death.
Not following the above WARNING could result in re or
electically unsafe conditions which could cause moderate
or serious property damage.
Read, understand and follow the above warning.
NOTICE
FIRE HAZARD
Wire Size Use ONLY wiring size recommended for single outlet branch circuit.
Fuse/Circuit Breaker Use ONLY the correct HACR type and size fuse/circuit breaker. Read electrical ratings on units
rating plate. Proper circuit protection is the responsibiity of the homeowner.
Grounding Unit MUST be grounded from branch circuit through service cord to unit, or through separate
ground wire provided on permanently connected units. Be sure that branch circuit or general
purpose outlet is grounded. Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet. (CP 14, 18, 24)
Receptacle The eld supplied outlet must match plug on service cord and be within reach of service cord.
Do NOT alter the service cord or plug. Do NOT use an extension cord. Refer to the table above
for proper receptacle and fuse type.
Plug/Outlet/Circuit Rating
Model
Circuit Rating
Breaker or T-D Fuse
Plug Face
(NEMA#)
Power Cord
Length (ft.)
Wall Outlet
Appearance
CP14 125V - 15A 5 - 15P 6
CP18 250V - 15A 6 - 15P 4
CP24 250V - 20A 6 - 20P 4
6
7
ELECTRICAL SHOCK HAZARD
WARNING
Plug into a grounded 3 prong outlet.
Do not remove powercord ground prong.
Do not use a plug adapter.
Do not use an extension cord.
Failure to follow these instructions can
result in death, re, or electrical shock.
This air conditioner must be grounded. This air conditioner
is equipped with a power supply cord having a grounded 3
prong plug. To minimize possible shock hazard, the cord
must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances.
If a mating outlet is not available, it is the customer’s
responsibility to have a properly grounded 3 prong outlet
installed by a qualied electrical component installer.
It is the customer’s responsibility:
To contact a qualied electrical installer, and to assure
that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 - latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
Recommended grounding method
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet.
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and
pop out).
4. Press and release RESET (listen for click; Reset butto
will latch and remain in). The power supply cord is ready
for operation.
NOTES:
The Reset button must be pushed in for proper
operation.
The power supply cord must be replaced if it fails to trip
when the test button is pressed or if it fails to reset.
Do not use the power supply cord as an off/on switch.
The power supply cord is designed as a protective
device.
A damaged power supply cord must be replaced with
a new power supply cord obtained from the product
manufacturer and must not be repaired.
The power supply cord contains no user serviceable
parts. Opening the tamper-resistant case voids all
warranty and performance claims.
Power Supply Cord
NOTE: Your unit’s device may differ from the ones shown.
A. Reset button
B. Test button
This room air conditioner is equipped with a power supply
cord required by UL. This power supply cord contains
state-of-the-art electronics that sense leakage current. If
the cord is crushed, the electronics detect leakage current
and power will be disconnected in a fraction of a second.
TEST
TEST
RESET
RESET
A
A
B
B
SPECIFICATIONS FOR 2009 MODELS
8
Performance Data
PERFORMANCE
DATA* Cooling
EVAP. AIR TEMP.
DEG. F
CONDENSER
TEMPERATURE
DEG. F
Discharge
Temp
Suction
Temp
Super
Heat
Sub-Cooling
OPERATING
PRESSURES
ELECTRICAL RATINGS R-22 REF.
Voltage
BREAKER
FUSE
Discharge
Air
Temp.
Drop F.
Suction Discharge
Amps
Cool
Amps
Heat
Locked
Rotor Amps
Charge in
OZ.
60 Hertz
Amps
CP14N10
59 21 118 173 56 41 54 78 267 12.1 / 58 26.5 115 15
CP18N30
58 22 119 173 66 52 55 77 269 8.3 /
38.9/42.4 27.9
230
15
802/5.8 962 775525 66 271 911 32 75
CP24N30
57 23 117 197 60 44 50 75 264 12.3 /
56A(230V) 33.5
230
20
802/1.31 462 570544 75 591 711 42 65
*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity.
Compressor Type
Rotary Rotary Rotary
L.R.A. (A)
61 42 60
Compressor RLA(A)
11.5 11.2/10.7
Compressor Power Input(W)
1060
2310/2390
Overload Protector
InternalExternal Internal
Throttling Method
Capillary Capillary Capillary
Starting Method Capacitor Capacitor Capacitor
Working Temp Range (
F
)
50°-115° 50°-115° 50°-115°
Condenser
Aluminum fin-copper tube Aluminum fin-copper tube Aluminum fin-copper tube
Fan Type-Piece
Axial fan –1 Axial fan –1 Axial fan –1
F
an Diameter (inches)
15.59 15.59 15.59
900/780/730 1000/900/800 1060/970/820
205 297 320
1.78 1.29 1.39
15 7 7
300 300 300
150 150 150
17
½
X 26 X 27
17
½
X 26 X 29
¾
17
½
X 26 X 29
¾
121 141 165
R22/28.57 R22/32.10 R22/37.04
Outdoor
Side
Fan Motor Speed (rpm) (H/M/L)
Output of Fan Motor (W)
Fan Motor RLA(A)
Fan Motor Capacitor (uF)
Net
Weight
Refrigerant Charge (oz)
Permissible Excessive Operating
Pressure for the Discharge
Side(PSI)
Permissible Excessive Operating
Pressure for the Suction Side(PSI)
Dimension (W/H/D)
7.5
1606
CP14E10 CP18E30 CP24E30
COOLING
COOLING
COOLING
115V 208~230V 208~230V
60Hz 60Hz 60Hz
14700(Btu/h) 18000 /18450(Btu/h)
/ (Btu/h)
1370 1680/1730 2660/2690
1757W 2259W 3295W
17.61A 9.02A 15A
798/730/696 968/918/866 1002/950/866
5.28 5.92 9.93
10.8 10.8 / 10.8 9.4 / 9.4
Fan Type-Piece Centrifugal flow fan 1 Centrifugal flow fan – 1 Centrifugal flow fan – 1
Diameter-Length (inch) 8.82 X 4.31 8.82 X 4.31 8.82 X 4.31
Evaporator Aluminum fin-copper tube Aluminum fin-copper tube Aluminum fin-copper tube
Pipe Diameter (inches)
.276 .276 .276
Coil length (l) x height (H) x
coil width (L)
422 X 381 X 25.4 422 X 381 X 25.4 422 X 381 X 25.4
Model
Function
Rated Voltage
Rated Input (W)
Rated Current (A)
Air Flow Volume
(CFM) (H/M/L)
Rated Frequency
Total Capacity (W/
Btu/h)
Power Input (W)
Indoor
Side
Dehumidifying Volume (pints/h)
EER
PERFORMANCE
DATA* Cooling
EVAP. AIR TEMP.
DEG. F
CONDENSER
TEMPERATURE
DEG. F
Discharge
Temp
Suction
Temp
Super
Heat
Sub-Cooling
OPERATING
PRESSURES
ELECTRICAL RATINGS R-22 REF.
Voltage
BREAKER
FUSE
Discharge
Air
Temp.
Drop F.
Suction Discharge
Amps
Cool
Amps
Heat
Locked
Rotor Amps
Charge in
OZ.
60 Hertz
Amps
CP14N10
59 21 118 173 56 41 54 78 267 12.1 / 58 26.5 115 15
CP18N30
58 22 119 173 66 52 55 77 269 8.3 /
38.9/42.4 27.9
230
15
802/5.8 962 775525 66 271 911 32 75
CP24N30
57 23 117 197 60 44 50 75 264 12.3 /
56A(230V) 33.5
230
20
802/1.31 462 570544 75 591 711 42 65
*Rating Conditions: 80 degrees F, room air temp. & 50% relative humidity, with 95 degree F, outside air temp & 40% relative humidity.
Compressor Type
Rotary Rotary Rotary
L.R.A. (A)
58 42 56
Compressor RLA(A)
10.9 11.7/11.0
Compressor Power Input(W)
1182
2425/2480
Overload Protector
ExternalExternal Internal
Throttling Method
Capillary Capillary Capillary
Starting Method Capacitor Capacitor Capacitor
Working Temp Range (
F
)
50°-115° 50°-115° 50°-115°
Condenser
Aluminum fin-copper tube Aluminum fin-copper tube Aluminum fin-copper tube
Fan Type-Piece
Axial fan –1 Axial fan –1 Axial fan –1
F
an Diameter (inches)
15.59 15.59 15.59
900/780/730
900/780/730 1000/900/800
200 200 190
3 1.45 1.35
15 7 7
300 300 300
150 150 150
17
½
X 26 X 27
17
½
X 26 X 27
17
½
X 26 X 29
¾
121 141 165
R22/26.46 R22/27.87 R22/33.51
Outdoor
Side
Fan Motor Speed (rpm) (H/M/L)
Output of Fan Motor (W)
Fan Motor RLA(A)
Fan Motor Capacitor (uF)
Net
Weight
Refrigerant Charge (oz)
Permissible Excessive Operating
Pressure for the Discharge
Side(PSI)
Permissible Excessive Operating
Pressure for the Suction Side(PSI)
Dimension (W/H/D)
7.45
1700
CP14N10 CP18N30 CP24N30
COOLING
COOLING
COOLING
115V 230V/208V~ 230V/208V~
60Hz 60Hz 60Hz
14000(Btu/h) 18000 /17600(Btu/h) 23500/23100(Btu/h)
1430 1850/1810 2740/2710
1540W 2478W 3538W
15A 12.57A 18.09A
458.8 458.8 617.6
3.38 4.65 8.46
9.8 9.7 / 9.7 8.6 / 8.5
Fan Type-Piece Centrifugal flow fan 1 Centrifugal flow fan – 1 Centrifugal flow fan – 1
Diameter-Length (inch) 7.93 X 4.31 7.93 X 4.31 8.82 X 4.31
Evaporator Aluminum fin-copper tube Aluminum fin-copper tube Aluminum fin-copper tube
Pipe Diameter (inches)
0.276 0.276 0.276
Coil length (l) x height (H) x
coil width (L)
16.61 X 15 X 1 16.61 X 15 X 1 16.61 X 15 X 1
Model
Function
Rated Voltage
Rated Input (W)
Rated Current (A)
Air Flow Volume
(CFM) (H/M/L)
Rated Frequency
Total Capacity (W/Btu/h)
Power Input (W)
Indoor
Side
Dehumidifying Volume (pints/h)
EER
9
SPECIFICATIONS FOR 2008 MODELS
Performance Data
10
COMPONENT DEFINITIONS
A. Mechanical components
B. Electrical components
C. Hermetic components
Vent door
Exhausts stale room air outside.
Plenum assembly
Diffuser with directional louvers used to direct the conditioned airow.
Blower wheel
Attaches to the indoor side of the fan motor shaft and is used for distributing unconditioned, room side air through
the heat exchanger and delivering conditioned air into the room.
Slinger fan blade
Attaches to the outdoor side of the fan motor shaft and is used to move outside air through the condenser coil, while
slinging condensate water out of the base pan and onto the condenser coil, thus lowering the temperature and
pressures within the coil.
Thermistor
A sensor that automatically responds to temperature changes.
Capacitor
Reduces line current and steadies the voltage supply, while greatly improving the torque characteristics of the fan
motor and compressor motor.
MoneySaver® switch
Used to regulate the operation of the fan motor and the compressor or to turn the unit off. For troubleshooting, refer
to the wiring diagrams and schematics in the back of this service manual.
Fan Motor
Dual-shafted fan motor operates the indoor blower wheel and the condenser fan blade simultaneously.
Compressor
Motorized device used to compress refrigerant through the sealed system.
Capillary tube
A cylindrical meter device used to evenly distribute the ow of refrigerant to the heat exchangers (coils).
AIR CONDITIONER USE
Operating the air conditioner properly helps you to obtain
the best possible results.
This section explains proper air conditioner operation.
IMPORTANT:
If you turn off the air conditioner, wait at least 3 minutes
before turning it back on. This prevents the air conditioner
from blowing a fuse or tripping a circuit breaker.
Do not try to operate your air conditioner in the cool-
ing mode when outside temperature is below 65°F
(18°C). The inside evaporator coil will freeze up, and
the air conditioner will not operate properly.
NOTE: In the event of a power failure, your air condi-
tioner will operate at the previous settings when the
power is restored.
11
1. Press POWER to turn on air conditioner.
NOTE: When the unit is turned on, it will display the previous
settings for the Mode, Fan Speed and temperature.
2. Choose mode. See “Mode.”
3. Choose fan speed. See “Fan Speed.”
4. Choose temperature. See “Temperature.
Mode
1. Press and hold MODE.
2.
Cool—Cools room. Press FAN SPEED to choose fan
speed. Then adjust the temperature by pressing the up or
down arrow buttons.
Fan—Operates the fan at High speed, without cool ing.
The display shows FO (fan only).
Fan Speed
NOTE: The Fan Speed button will operate only when the Cool or
Power Saver mode ha s been selected.
1. Press and hold FAN SPEED until you see the indicator light
for the desired setting.
2. Choose High, Medium or Low.
Temperature
Press, or press and hold, the plus button to raise the
temperature 1º until it reaches 86ºF (30ºC).
Press, or press and hold, the minus button to lower the
temperature 1º until it reaches 64ºF (18ºC).
Timer Delay
To set the Timer for a 1- to 24-hour delay until the air
conditioner turns o (the air conditioner must be On):
1. Press TIMER. Indicator light will ash.
2. Press the plus or minus button to change the delay time from
1 to 24 hours.
3. Press TIMER or wait 10 seconds. Indicator light will remain
on.
To set the Timer delay for a 1- to 24-hour delay until the air
conditioner turns on, keeping previous settings:
1. Turn o air conditioner.
2. Press TIMER. Indicator light wi
ll ash.
3. Press the plus or minus button to change the delay time from
1 to 24 hours.
4. Press TIMER or wait 10 seconds. Indicator light will remain
on.
To set the Timer delay for a 1- to 24-hour delay until the air
conditioner turns on, changing previous settings:
1. Turn on air conditioner.
2. Adjust MODE to desired setting.
3. Adjust FAN SPEED to High, Medium or Low.
4. Adjust temperature between 64ºF (18ºC) and 86ºF (30ºC).
5. Turn o air conditioner.
6. Press TIMER. Indicator light will ash.
7. Press the plus or minus button to change delay time from 1 to
24 hours.
8. Press TIMER or wait 10 seconds.
To clear Timer delay program
NOTE: Air conditioner can be either on or o.
Press and hold TIMER for 3 seconds. Indicator light will turn o.
To see the time remaining (in hours)
1. Press TIMER once after it has been set.
2. While the display is showing the remaining time, you can
press the plus or minus button to increase or decrease the
time.
POWER
Temp/Hour
Timer
Fan Speed
Fan Only
Cool
Money
Saver
®
High
Med
Low
0
F
Mode
Hr.
Auto Swing
Temp/Hour
0
F
Hr.
Timer
Money Saver Turns fan to low speed when
room temperature reaches the temperature setting
on the thermostat.
Fan Only
Cool
Mode
Money
Saver
®
Fan Speed
High
Med
Low
POWER
Money Saver
®
Choose Cool or Fan mode
How to operate the Friedrich room air conditioner
12
To operate air conditioner with remote control
NOTE: Remote control may vary in appearance.
NOTE: Two AAA batteries (included) power the remote control.
Replace batteries after 6 months of use, or when the remote
control starts to lose power.
To turn the air conditioner on or o:
Press POWER.
To select the mode:
To select the fan speed:
Press FAN SPEED for High, Medium or Low.
To raise the temperature:
Press the plus button to raise the temperature. Each time you
press or hold
the plus button, the temperature will go up 1º until it
reaches 86°F (30°C).
To lower the temperature:
Press the minus button to lower the temperature. Each time you
press or hold the minus button, the temperature will go down 1º
until it reaches 64°F (18°C).
To set Timer for a 1- to 24-hour delay before air conditioner
is turned o (air conditioner must be On):
1. Press TIMER. Indicator light on air conditioner control panel
will ash.
2. Press the plus or minus b
utton to change the delay time from
1 to 24 hours.
3. Press TIMER again or wait 10 seconds. Indicator light on air
conditioner control panel will remain on.
To set Timer to turn on air conditioner, keeping previous
settings:
1. Turn o air conditioner.
2. Press TIMER. Indicator light on air conditioner control panel
will ash.
3. Press the plus or minus button to change delay time (1 to
24 hours).
4. Press TIMER again or wait 10 seconds. Indicator light on air
conditioner control panel will remain on.
To set Timer to turn on air conditioner, changing the
previous settings:
1. Turn on air conditioner.
2. Adjust Mode to Cool, Fan Only, or Power Saver.
3. Adjust Fan Speed to High, Medium or Low.
4. Adjust temperature between 64°F (18ºC) and 86°F (30ºC).
5. Turn o air conditioner.
6. Press TIMER. Indicator light on air conditioner control panel
will ash.
7. Press the plus or minus button to change delay time (1 to
24 hours).
8. Press TIMER again or
wait 10 seconds. Indicator light on air
conditioner control panel will remain on.
Press COOL, FAN or $ SAVER
Suction
Line
Evaporator
Coil
Metering
Device
Refrigerant
Strainer
Discharge
Line
Condenser
Coil
Compressor
Refrigerant Drier
Liquid
Line
A good understanding of the basic operation of the
refrigeration system is essential for the service technician.
Without this understanding, accurate troubleshooting of
refrigeration system problems will be more difcult and time
consuming, if not (in some cases) entirely impossible. The
refrigeration system uses four basic principles (laws) in its
operation they are as follows:
1. “Heat always ows from a warmer body to a cooler
body.”
2. “Heat must be added to or removed from a substance
before a change in state can occur”
3. “Flow is always from a higher pressure area to a lower
pressure area.”
4. “The temperature at which a liquid or gas changes state
is dependent upon the pressure.”
The refrigeration cycle begins at the compressor. Starting
the compressor creates a low pressure in the suction line
which draws refrigerant gas (vapor) into the compressor.
The compressor then “compresses” this refrigerant, raising
its pressure and its (heat intensity) temperature.
The refrigerant leaves the compressor through the discharge
Line as a hot High pressure gas (vapor). The refrigerant
enters the condenser coil where it gives up some of its
heat. The condenser fan moving air across the coil’s nned
surface facilitates the transfer of heat from the refrigerant to
the relatively cooler outdoor air.
When a sufcient quantity of heat has been removed from
the refrigerant gas (vapor), the refrigerant will “condense”
(i.e. change to a liquid). Once the refrigerant has been
condensed (changed) to a liquid it is cooled even further by
the air that continues to ow across the condenser coil.
The RAC design determines at exactly what point (in the
condenser) the change of state (i.e. gas to a liquid) takes
place. In all cases, however, the refrigerant must be
totally condensed (changed) to a Liquid before leaving the
condenser coil.
The refrigerant leaves the condenser Coil through the liquid
line as a warm high pressure liquid. It next will pass through
the refrigerant drier (if so equipped). It is the function of the
drier to trap any moisture present in the system, contaminants,
and large particulate matter.
The liquid refrigerant next enters the metering device. The
metering device is a capillary tube. The purpose of the
metering device is to “meter” (i.e. control or measure) the
quantity of refrigerant entering the evaporator coil.
In the case of the capillary tube this is accomplished (by
design) through size (and length) of device, and the pressure
difference present across the device.
Since the evaporator coil is under a lower pressure (due to
the suction created by the compressor) than the liquid line,
the liquid refrigerant leaves the metering device entering the
evaporator coil. As it enters the evaporator coil, the larger
area and lower pressure allows the refrigerant to expand
and lower its temperature (heat intensity). This expansion is
often referred to as “boiling”. Since the unit’s blower is moving
indoor air across the nned surface of the evaporator coil,
the expanding refrigerant absorbs some of that heat. This
results in a lowering of the indoor air temperature, hence the
“cooling” effect.
The expansion and absorbing of heat cause the liquid
refrigerant to evaporate (i.e. change to a gas). Once the
refrigerant has been evaporated (changed to a gas), it is
heated even further by the air that continues to ow across
the evaporator coil.
The particular system design determines at exactly what
point (in the evaporator) the change of state (i.e. liquid to a
gas) takes place. In all cases, however, the refrigerant must
be totally evaporated (changed) to a gas before leaving the
evaporator coil.
The low pressure (suction) created by the compressor
causes the refrigerant to leave the evaporator through the
suction line as a cool low pressure vapor. The refrigerant then
returns to the compressor, where the cycle is repeated.
REFRIGERATION SYSTEM SEQUENCE OF OPERATION
13
Refrigerant Charging
NOTE: Because The RAC System Is A Sealed System,
Service Process Tubes Will Have To Be Installed. First
Install A Line Tap And Remove Refrigerant From System.
Make Necessary Sealed System Repairs And Vacuum
System. Crimp Process Tube Line And Solder End Shut.
Do Not Leave A Service Valve In The Sealed System.
Proper refrigerant charge is essential to proper unit
operation. Operating a unit with an improper refrigerant
charge will result in reduced performance (capacity) and/or
efciency. Accordingly, the use of proper charging methods
during servicing will insure that the unit is functioning as
designed and that its compressor will not be damaged.
Too much refrigerant (overcharge) in the system is just as bad
(if not worse) than not enough refrigerant (undercharge). They
both can be the source of certain compressor failures if they
remain uncorrected for any period of time. Quite often, other
problems (such as low air ow across evaporator, etc.) are
misdiagnosed as refrigerant charge problems. The refrigerant
circuit diagnosis chart will assist you in properly diagnosing
these systems.
An overcharged unit will at times return liquid refrigerant
(slugging) back to the suction side of the compressor eventually
causing a mechanical failure within the compressor. This
mechanical failure can manifest itself as valve failure, bearing
failure, and/or other mechanical failure. The specic type of
failure will be inuenced by the amount of liquid being returned,
and the length of time the slugging continues.
Not enough refrigerant (undercharge) on the other hand, will
cause the temperature of the suction gas to increase to the point
where it does not provide sufcient cooling for the compressor
motor. When this occurs, the motor winding temperature will
increase causing the motor to overheat and possibly cycle open
the compressor overload protector. Continued overheating of
the motor windings and/or cycling of the overload will eventually
lead to compressor motor or overload failure.
Unplug and/or disconnect all electrical power
to the unit before performing inspections,
maintenances or service.
Failure to do so could result in electric shock,
serious injury or death.
Sealed Refrigeration System contains refrigerant
and oil under high pressure.
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with refrigerants.
Failure to follow these procedures could
result in serious injury or death.
WARNING
WARNING
RISK OF ELECTRIC SHOCK
HIGH PRESSURE HAZARD
SEALED REFRIGERATION SYSTEM REPAIRS
ANY SEALED SYSTEM REPAIRS TO COOL-ONLY MODELS REQUIRE THE INSTALLATION OF A LIQUID LINE DRIER.
ALSO, ANY SEALED SYSTEM REPAIRS TO HEAT PUMP MODELS REQUIRE THE INSTALLATION OF A SUCTION LINE DRIER.
IMPORTANT
EQUIPMENT REQUIRED:
1. Voltmeter
2. Ammeter
3. Ohmmeter
4. E.P.A. Approved Refrigerant Recovery System
5. Vacuum Pump (capable of 200 microns or less
vacuum.)
6. Acetylene Welder
7. Electronic Halogen Leak Detector (G.E. Type H-6 or
equivalent.)
8. Accurate refrigerant charge measuring device such
as:
a. Balance Scales - 1/2 oz. accuracy
b. Charging Board - 1/2 oz. accuracy
9. High Pressure Gauge - (0 - 400 lbs.)
10. Low Pressure Gauge - (30 - 150 lbs.)
11. Vacuum Gauge - (0 - 1000 microns)
EQUIPMENT MUST BE CAPABLE OF:
1. Recovery CFC’s as low as 5%.
2. Evacuation from both the high side and low side of the
system simultaneously.
3. Introducing refrigerant charge into high side of the
system.
4. Accurately weighing the refrigerant charge actually
introduced into the system.
5. Facilities for owing nitrogen through refrigeration tubing
during all brazing processes.
14
3. Install a process tube to sealed system.
4. Make necessary repairs to system.
5. Evacuate system to 200 microns or less.
6. Weigh in refrigerant with the property quantity of R-22
refrigerant.
7. Start unit, and verify performance.
8. Crimp the process tube and solder the end shut.
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with a torch.
Failure to follow these procedures could
result in moderate or serious injury.
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with liquid refrigerant.
Failure to follow these procedures could
result in minor to moderate injury.
WARNING
CAUTION
BURN HAZARD
FREEZE HAZARD
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with a torch.
Failure to follow these procedures could
result in moderate or serious injury.
WARNING
BURN HAZARD
Method Of Charging / Repairs
The acceptable method for charging the RAC system is the
Weighed in Charge Method. The weighed in charge method is
applicable to all units. It is the preferred method to use, as it is
the most accurate.
The weighed in method should always be used whenever
a charge is removed from a unit such as for a leak repair,
compressor replacement, or when there is no refrigerant
charge left in the unit. To charge by this method, requires the
following steps:
1. Install a piercing valve to remove refrigerant from the
sealedsystem. (Piercing valve must be removed from the
system before recharging.)
2. Recover Refrigerant in accordance with EPA regulations.
15
Undercharged Refrigerant Systems
An undercharged system will result in poor performance
(low pressures, etc.) in both the heating and cooling
cycle.
Whenever you service a unit with an undercharge of
refrigerant, always suspect a leak. The leak must be
repaired before charging the unit.
To check for an undercharged system, turn the unit on,
allow the compressor to run long enough to establish
working pressures in the system (15 to 20 minutes).
During the cooling cycle you can listen carefully at the exit
of the metering device into the evaporator; an intermittent
hissing and gurgling sound indicates a low refrigerant
charge. Intermittent frosting and thawing of the evaporator
is another indication of a low charge, however, frosting
and thawing can also be caused by insufcient air over
the evaporator.
Checks for an undercharged system can be made at
the compressor. If the compressor seems quieter than
normal, it is an indication of a low refrigerant charge.
Overcharged Refrigerant Systems
A check of the amperage drawn by the compressor
motor should show a lower reading. (Check the Unit
Specication.) After the unit has run 10 to 15 minutes,
check the gauge pressures. Gauges connected to system
with an undercharge will have low head pressures and
substantially low suction pressures.
of the evaporator will not be encountered because the
refrigerant will boil later if at all. Gauges connected to
system will usually have higher head pressure (depending
upon amount of over charge). Suction pressure should be
slightly higher.
Compressor amps will be near normal or higher.
Noncondensables can also cause these symptoms. To
conrm, remove some of the charge, if conditions improve,
system may be overcharged. If conditions don’t improve,
Noncondensables are indicated.
Whenever an overcharged system is indicated, always
make sure that the problem is not caused by air ow
problems. Improper air ow over the evaporator coil may
indicate some of the same symptoms as an over charged
system.
An overcharge can cause the compressor to fail, since it
would be “slugged” with liquid refrigerant.
The charge for any system is critical. When the compressor
is noisy, suspect an overcharge, when you are sure that
the air quantity over the evaporator coil is correct. Icing
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation.
Extreme care must be used, if it becomes
necessary to work on equipment with power
applied.
Failure to do so could result in serious injury or
death.
Sealed Refrigeration System contains refrigerant
and oil under high pressure.
Proper safety procedures must be followed,
and proper protective clothing must be worn
when working with refrigerants.
Failure to follow these procedures could
result in serious injury or death.
WARNING
HIGH PRESSURE HAZARD
16
Restricted Refrigerant System
Troubleshooting a restricted refrigerant system can be
difcult. The following procedures are the more common
problems and solutions to these problems. There are two
types of refrigerant restrictions: Partial restrictions and
complete restrictions.
A partial restriction allows some of the refrigerant to
circulate through the system.
With a complete restriction there is no circulation of
refrigerant in the system.
Restricted refrigerant systems display the same symptoms
as a “low-charge condition.”
When the unit is shut off, the gauges may equalize very
slowly.
Gauges connected to a completely restricted system will
run in a deep vacuum. When the unit is shut off, the gauges
will not equalize at all.
A quick check for either condition begins at the evaporator.
With a partial restriction, there may be gurgling sounds
at the metering device entrance to the evaporator. The
evaporator in a partial restriction could be partially frosted
or have an ice ball close to the entrance of the metering
device. Frost may continue on the suction line back to the
compressor.
Often a partial restriction of any type can be found by feel,
as there is a temperature difference from one side of the
restriction to the other.
With a complete restriction, there will be no sound at the
metering device entrance. An amperage check of the
compressor with a partial restriction may show normal
current when compared to the unit speci cation. With a
complete restriction the current drawn may be considerably
less than normal, as the compressor is running in a deep
vacuum (no load.) Much of the area of the condenser will
be relatively cool since most or all of the liquid refrigerant
will be stored there.
The following conditions are based primarily on a system
in the cooling mode.
17
METERING DEVICE
Capillary Tube Systems
All units are equipped with capillary tube metering
devices.
Checking for restricted capillary tubes.
1. Connect pressure gauges to unit.
2. Start the unit in the cooling mode. If after a few minutes
of operation the pressures are normal, the check valve
and the cooling capillary are not restricted.
3. Switch the unit to the heating mode and observe
the gauge readings after a few minutes running time.
If the system pressure is lower than normal, the heating
capillary is restricted.
4. If the operating pressures are lower than normal in
both the heating and cooling mode, the cooling
capillary is restricted.
Locked Rotor Voltage (L.R.V.) Test
Locked rotor voltage (L.R.V.) is the actual voltage available
at the compressor under a stalled condition.
Single Phase Connections
Disconnect power from unit. Using a voltmeter, attach one
lead of the meter to the run “R” terminal on the compressor
and the other lead to the common “C” terminal of the com-
pressor. Restore power to unit.
Determine L.R.V.
Start the compressor with the volt meter attached; then stop
the unit. Attempt to restart the compressor within a couple
of seconds and immediately read the voltage on the meter.
The compressor under these conditions will not start and will
usually kick out on overload within a few seconds since the
pressures in the system will not have had time to equalize.
Voltage should be at or above minimum voltage of 197 VAC,
as specied on the rating plate. If less than minimum, check
for cause of inadequate power supply; i.e., incorrect wire
size, loose electrical connections, etc.
COMPRESSOR CHECKS
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation. Extreme care must be used, if it
becomes necessary to work on equipment with
power applied.
Failure to do so could result in serious injury or
death.
Amperage (L.R.A.) Test
The running amperage of the compressor is the most impor-
tant of these readings. A running amperage higher than that
indicated in the performance data indicates that a problem
exists mechanically or electrically.
Single Phase Running and L.R.A. Test
NOTE: Consult the specication and performance section
for running amperage. The L.R.A. can also be found on the
rating plate.
Select the proper amperage scale and clamp the meter
probe around the wire to the “C” terminal of the compres-
sor. Turn on the unit and read the running amperage on
the meter. If the compressor does not start, the reading
will indicate the locked rotor amperage (L.R.A.).
External Overload
The compressor is equipped with an external overload
which senses both motor amperage and winding tem-
perature. High motor temperature or amperage heats the
overload causing it to open, breaking the common circuit
within the compressor.
Heat generated within the compressor shell, usually due
to recycling of the motor, is slow to dissipate. It may take
anywhere from a few minutes to several hours for the
overload to reset.
Checking the External Overload
With power off, remove the leads from compressor termi-
nals. If the compressor is hot, allow the overload to cool
before starting check. Using an ohmmeter, test continu-
ity across the terminals of the external overload. If you
do not have continuity; this indicates that the overload is
open and must be replaced.
Certain unit components operate at
temperatures hot enough to cause burns.
Proper safety procedures must be followed,
and proper protective clothing must be
worn.
Failure to follow this warning could result
in moderate to serious injury.
WARNING
BURN HAZARD
ELECTRIC SHOCK HAZARD
WARNING
Turn off electric power before service or
installation. Extreme care must be used, if it
becomes necessary to work on equipment
with power applied.
Failure to do so could result in serious injury or
death.
18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Friedrich QUIETMASTER 2009 Owner's manual

Category
Split-system air conditioners
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI