RAIS Vola Soapstone Instructions For Installation, Use And Maintenance Manual

Type
Instructions For Installation, Use And Maintenance Manual

This manual is also suitable for

ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
1
INSTRUCTIONSFORINSTALLATION,
USEANDMAINTENANCE
RAISGABO,RAISPIN A,RAISVOL A/SOAPSTONE
IMPORTANTINFORMATION
Onfirstlightingthestoveyoumustbecarefuln ottotoucht hepainted
surfacesanditisMOSTIMPORTANTthatthedooriskeptslightly‘ajarin
orderforthedoorsealandsealanttocure.
Thiswillpreventthedoorsealstickingtothepaintedbo dyandbecoming
damaged.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
2
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
3
INTRODUCTION...………………………………………………………….. 4
WARRANTY..……………………………… …………………….………….. 4
SPECIFICATIONS……………………………………………… ………….. 5
CONVECTION………………………………………………………………. 6
INSTALLATIONINSTRUCTIONS ………………………………….……… 7
CHIMNEY………………………………………………………….…………. 89
INSTALLATION…………………………… ………………………………... 10
OPERATIONOFSWIVELBASE….………………………………………. 11
INSTALLATIONOFSOAPSTONE(VOLASOAPSTONE)….……….. 1213
INSTALLATIONDISTANCETOCOMBU STIBLEWALL……………… 16
GENERALINSTALLATION(RIGHTAN GLE)SECUREBASE….….. 16
CORNERINSTALLATION45°…………………………………. 16
360°SWIVELBASE…………………………………………….. 17
90°SWIVELBASE………………………………………………. 17
INSTALLATIONDISTANCETONONCO MBUSTIBLEWALL………. 17
FORTHEINSTALLER……………………………………………………… 18
OPERATINGINSTRUCTIONS…………………………………………….. 19
FUEL…………………………………………………………………………... 19
DRYINGANDSTORAGE…………………………………………………… 20
REGULATIONOFCOMBUSTIONAIR…………………………………… 21
USINGTHEWOODBURNINGSTOVE…………………………………… 22
FIRSTUSAGE………………………………………………………………… 23
LIGHTINGANDFUELLING………………………………………………… 2425
CLEANINGANDCARE………………… ………………………………….. 26
CLEANINGOFTHEFLUEWAYS………………………………………… 27
PROBLEMSOLVING……………………………………………………….. 28
ACCESSORIESANDSPAREPARTS……………………………………. 29
SPAREPARTDIAGRAM…….………..……………………………………. 2934
Revision:
Date :2011
RaisGabo,RaisPina,RaisVolaandRaisVolaSoapstone
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
4
ARaiswoodburningstoveismorethanjustaheatsource:i talsoshowsthatyoucare
aboutdesignandqualityinyourhome.
Tomakethemostofyourwoodburningstoveitisimportantthatyoureadthemanual
thoroughlybeforeinstallingandusingit.
Inthecaseofwarrantycoverage,andforgeneralqueriesregardingyourwoodburn
ingstove,itisimportantthatyouknowthestove’sproductionnumber.
Wethereforerecommendt hatyounotedownthenumberinthetablebelow.
Theproductionnumberislocatedinthetopoftheconvectio nbox.
Warranty
YourRaiswoodburningstovecomeswitha5yearwarranty.
Thewarranty,however,doesnotcoverheatinsulatingmaterials,glassandseals.
TheseareavailabletoorderfromyourlocalRaisdealer/stockist.
Anyalterationsmadetothestovewillvoidthewarranty.
Introduction
ThankyouforpurchasingaRaiswoodburningstove.
TheseapplianceshavebeenapprovedbyHETASas
intermittentoperatingappliancesforburningwoodlogsonl y.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
5
RaisGabo RaisPin a RaisVola RaisVola
Soapstone
Nominaloutput(kW): 5 5 5 5
Min./Max.output( kW): 2  6 2  6 2  6 2  6
Heatingarea(m
2
): Ca.80 Ca.80 Ca.80 Ca.80
Size,widt h/depth/height(mm): 510/460/1005 552/455/1120 530/421/
1190
540/430/
1230
Combustionchamberwidth/depth/height(mm). 376/245/367 376/245/367 376/245/
367
376/245/367
Recommendedamountofwoodwhenfuelling(kg)
(Basedon2  3logsofwoodapprox.25cm)
1.5 1.5 1.5 1.5
Min.uptake/Min.draught(Pascal): 12 12 12 12
Weight(kg):  140 140 150 203
Efficiency(%):
ParticlesafterNS3058/3059(g/kg):
DustmeasuredaccordingtoDin+(mg/Nm
3
):
Smokegasmassflow(g/s): 5.4 5.4 5.4 5.4
Smokegastemperature(°C): 260 260 260 260
Intermittentoperation: Fuellingshouldbeundertakenwithin3hours
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3mstraightflue.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
6
Thestovesareequippedwithcooldoorhandles  aRaisspecialfeature whichmeans
youcouldalmostdoawaywithgloves.Beaware,however,thatallexteriorsurfaces
becomehotduringuse  sot akeextremecare.
Convection
Raisstovesareconvectionstoves.Thismeansthatthestove’sbackandsidepanelsare
notoverheated.Convectionmeansthatthereisacirculationofair,whichensuresthat
theheatisdistributedmoreevenlythroughoutthee ntireroom.Thecoldairissuckedinat
thebaseofthestoveandupthroughtheconvectionchannel,whichrunsalongthe
stove’scombustionchamber.Theheatedaircomesoutatt hetopofthestove,which
ensuresacirculationofwarmairthroughouttheroom.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
7
InstallationInstructions
Thefollowingpagesgiveinstructionsforthesafeandpro perinstall ationofthisheating
applianceintheUK.Theseinstructionscoverthebasicprinciplesofinstallation,
althoughsomedetailsmayneedslightmodificationtosuitparticularlocalsiteconditions.
InallcasestheinstallationmustcomplywithcurrentUKBuildingRegulations,Local
AuthorityByelawsandotherspecificationsorregulationsastheyaffecttheinstallationof
thestove.
PleasenotethatitisalegalrequirementunderEnglandandWalesBuildingRegulations
thattheinstallationofthestoveiseithercarriedoutunderlocalAuthorityBuilding
ControlapprovalorisinstalledbyaCompetentPersonregisteredwithaGovernment
approvedCompetentPersonsScheme.HETASoperatesuchaschemeandalistingof
theirregisteredCompetentPersonscanbefoundontheirwebsiteatwww.hetas.co.uk.
ItshouldbenotedthatthecurrentBuildingRegulationsrequirementsaregivenin
ApprovedDocumentJ.Theserequirementsmayalsobemetbyadoptingt herelevant
recommendationsgiveninBritishStandardsBS8303,BS6461andBS7566.
WARNING.HealthandSafetyAdviceNotice.
TheinstallationofthisheatingapplianceisgovernedbytheHealthandSafetyatWork
Act1974.itistheresponsibilityoftheinstallertoensurethatallrequirementsofthisAct
aremetduringtheinstallationworks.Attentionisdrawninparticulartothefollowing:
Handling: Theapplianceisaheavyitemandadequatefacilitiesmustbeavailable
forloading,unloadingandsitehandling.
FireCement: Sometypesoffirecementarecausticandshouldnotbeallowedtocome
intocontactwiththeskin.Protectiveglovesshouldbewornwhen
handlingfirecement.Incaseofcontactwiththeskin,washimmediately
withplentyofwater.
Asbestos: Thisstovecontainsnoasbestos.Ifthereisapossibilityofdisturbingany
asbestosinthecourseoftheinstallation,thenpleaseseekspecialist
guidanceanduseappropriateprotectiveequipment.
MetalParts: Wheninstallingorservicingthisstovecareshouldbetakentoavoidthe
possibilityofpersonalinjury.
ImportantWarning  PreparatoryWorkandsafetyChecks:
· Thisstovemustnotbeinstalledintoachimneywhichservesanyotherheating
appliance.
· Theremustnotbeanextractorfanfittedinthesameroomasthestove,asthiscan
causethestovetoemitfumesintotheroom.
· Ifthisapplianceisinstalledintoanexistingchimney,thechimneymustfirstbe
sweptandexaminedforsoundnessandsuitability,beforetheapplianceisinstalled
(seealsosectionheaded‘Chimney’).
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
8
Chimney
Thechimneyisthedrivingforcewhichmakesthestovefunction.Inorderforthestoveto
performsatisfactorilythechimneyheightmustbesufficienttoensurethecorrectdr aught
of14to18Pa,soastocleartheproductsofcombustionandpreventproblemsofsmoke
leakingintotheroomwhenthestoveislit.
Note:Achimneyheightofnotlessthan4.5metres,measuredverticallyfromtheoutletof
thestovetothetopofthechimney,shouldbesatisfactory.
AlternativelythecalculationproceduregiveninBS5854:1980maybeusedasthebasis
fordecidingwhetheraparticularchimneydesignwillprovidesufficientdraught.
PleaseNote,thisappliancehasbeentestedbythemanufacturersandworksona3m
straightflue.
Theoutletfromthechimneyshouldbeabovetheroofofthebuildinginaccordancewith
theprovisionsoftheBuildingRegulationsApprovedDocumentJ.
Iftheinstallationisintoanexistingchimney,thenitmustbesoundandhavenocracksor
otherfaultswhichmayallowfumesintothehouse.Olderproperties,especially,mayhave
chimneyfaultsorthecrosssectionmaybetoolargei.e.morethan230x230mm.
Remedialactionshouldbetakenifrequired,expertadviceshouldbesoughtwhere
required.
Ifthechimneyrequireslining,thenasuitablesolidfuelfluelinermustbe used,in
accordancewithBuildingRegulationsApprovedDocumentJ.
Anyexistingchimneymustbeclearofobstructionandshouldhavebeensweptclean
immediatelybeforetheinstallationofthestove.Ifthestoveisfittedinplaceofanopen
fire,thenthechimneyshouldbesweptonemonthafterinstallationtoclearanysootfalls
whichmayhaveoccurredduetothedifferenceincombustionbetweenthestoveandthe
openfire.
Ifthereisnoexistingchimneytheneitheraprefabricatedblockchimney,inaccordance
withBuildingRegulationsApprovedDocumentJoratwinwallinsulatedstainlesssteel
fluetoBS4543canbeused.Thesechimneysmustbefittedinaccordancewiththe
manufacturer’sinstructionsandtheBuildingRegulations.
Asinglewallmetalfluepipeissuitableforconnectingthestovetothechimneybutis
notsuitableforusingforthecompletechimney.Thechimneyand
connectingfluepipemusthaveaminimumdiameterof150mmandit’s
dimensionshouldbenotlessthanthesizeoftheoutletsocketofthestovewhichis
150mm.Anybendinthechimneyorconnectingfluepipeshouldnotexceed45°.90°
bendsshouldnotbeused.
Combustiblematerialshouldnotbelocatedwheretheheatdissipatingthroughthe
wallsoffireplacesorfluescouldigniteit.Thereforewheninstallingthestoveinthe
presenceofcombustiblematerialsdueaccountmustbetakenofthe
guidanceontheseparationofcombustiblematerialgiveninBuildingRegulationsAp
provedDocumentJandalsointhesestoveinstructions.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
9
Ifitisfoundthatthereisexcessivedraughtinthechimneytheneitheran
adjustablefluedamperoralternativelyadraughtstabilisershouldbefitted.The
adjustablefluedampershouldnotcloseofftheflueentirely,butshouldinits
closedpositionleaveaminimumcontinuousopeningfreeareaofatleast20%
ofthetotalcrosssectionalareaoftheflueorfluepipe.
Adequateprovisione.g.easilyaccessiblesootdoorordoorsmustbeprovided
forsweepingthechi mneyandconnectingfluepipe.
Youshouldalsofamiliariseyourselfwiththedraughtconditionsforchimneys
with2flues.
Forstrongdraughts,thechimneyorflueshouldbefittedwithadraught
stabiliser.Inwhichcase,itisimportanttoensurethatthereisafreeflowthrough
areaofminimum20cm
2
whentheregulatinggateisshut.Otherwise,thefuel
energymaynotbeusedoptimally.
If,atanytime,youareunsureabouttheconditionofthechimney,youshould
contactachimneysweep.
Rememberthataccesstothesootdoorshouldbekeptcl ear.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
10
Installation
Itisprohibitedtocarryoutunauthorisedalterationstothestove.
Theremustbeplentyoffreshairintheroomwherethestoveisbeinginstalled,inorderto
ensurepropercombustion.Notethatanymechanicalexhaustventilatione.g.an
extractionhoodmayreducetheairsupply.Anyairgrillesmustbeplacedinsucha
manner,thattheairsupplyisnotblocked.
Thestoveisequippedwithfourconvectionairoutlets,whichmaybeconnectedwith
suitableairductstootherrooms.
BuildingRegulationsApprovedDocumentJgivesspecificguidanceontherequired
permanentventilationintotheroomforcombustionairofsolidfuelappliances.
Thefloorstructuremustbeabletocarrytheweightofthewoodburningstove,aswellas
theweightofachimney,ifnecessary.
WhenyouchoosewheretosetupyourRAISwoodburningstove,youshouldconsiderthe
heatdistributiontotheotherrooms.Thiswillenableyoutogetthebestuseoutofyour
stove.
Thestoveshouldbesetupatasafedistancefrominflammablematerials.
Seethemanufacturer'splateonthewoodburningstove.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
11
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
12
Ifthestovehasaturntablethenplease
dothefollowing:
Liftupthepositioningboltandrotatethe
stoveat30°intervals.
Whenyouhavereachedthedesired
position,releasethepositioningbolt,and
turnthestoveslightlyuntiltheboltclicks
intoplace.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
13
MounttheSoapstonesasillustrated:
1. Removethescrew(1)
2. Removethebackpanel(2)
3. Loosenthenut(3)underthetopplate.
4. Removethetopplate(4) pushthetop
platebackwardsandliftup.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
14
5. CarefullyplacetheSoapstoneonthe
socket(6)
6. Pushthetwoflatheadscrews(7)
throughtheplate(8)
7. Putthebrassbushes(9)o ntothe
screwsbetweentheplateandthe
Soapstone(5)
8. Tightentheflatheadscrewintothe
Soapstonebush(10)
8. Mountthetopplate(4)lowerthetop
plateintotheslotandpushitcarefully
towardthefrontofthestove
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
15
10. Refastenthenutunderthetopplate(3)
11. Replacethebackpanel(2)
12. Replacethescrew(1)andfastenthe
backpanel(2)
13. CarefullyplacetheSoapstonetopplate
(11)ontothesteeltopplate
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
16
Installationdistanceincaseofcombustiblewall
Tofindoutwhetherthewallnexttowherethestoveisgoingtobeinstalledisflammable,
youshouldcontactyourbuildi ngcontractororthelocalbuildingauthorities.
Thehearthshouldbeabletoaccommodatetheweightofthestove.Thechimneymustbe
independentlysupportedbywallbracketsoraceilingsupportplate.Theweightofthestove
isindicatedinthebrochure.
Thestoveshouldalwaysbeinstalledonanoncombustiblehearthofasizeandconstruction
thatisinaccordancewiththeprovisi onsofthecurrentUKBuildingRegulati onsApproved
DocumentJ.
Ifthestoveistobeinstalledonawoodenfloor,itmustbecoveredwithanoncombustible
materialatleast12mmthick,inaccordancewithUKBuildingRegulationsApproved
DocumentJ,toadistanceof300mminfrontofthestoveand150mmtoeachside
measuringfromthedoorofthecombustionchamber.
Theclearancedistancestocombustiblematerialbeneath,surroundi ngoruponthehearth
andwallsadjacenttothehearthshouldcomplywiththeguidanceontheseparationof
combustiblematerialgiveninUKBuildingRegulationsApprovedDocumentJandalsoin
thesestoveinstructions.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
17
Installationdistancefornoncombustible
walls.
Werecommendaminimumdistanceto
noncombustiblematerialof50mm(F)for
cleaningconsiderations.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
18
FortheInstaller
Finallybeforefiringthestoveforthefirsttimeacheckshouldbemadetoensurethatthe
assemblyandstoveinstallationhasbeensatisfactoryandthatt herearenoleaksinany
sealsintheapplianceandapplianceconnectionstothechimney.
Ensurethattheapplianceandchimneyfluearefunctioningcorrectlybeforefinally
handingovertotheuser.Readthelaterpartsofthismanualforguidanceoncare
requiredwhenfirstlighting.
Informtheuserthattheappliancehasbeencommissionedandreadytouseandgive
instructiononthesafeoperationofthestove.
TheseInstructionsmustbeleftwiththeuserandtheusershouldbeinstructedtokeep
theminasafeplace.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
19
ONLYUSERECOMMENDEDFUELS
Thefollowingtableshowsthecalori ficvalueofdifferenttypesofwood,whichhavebeen
storedfor2yearsandwhichhavearesidualmoistureof15 17%.
Wood Kgdrywoodprm
3
comparedtobeech/oak
Hornbeam 640 110%
Beechandoak 580 100%
Ash 570 98%
Maple 540 93%
Birch 510 88%
Mountainpine 480 83%
Fir 390 67%
Poplar 380 65%
1kgofwoodyieldsthesameheatenergyirrespectiveofwoodtype.
1kgofbeechmerelytakesuplessspacethan1kgoffi r.
Operatinginstructions
PleasenotethatHETASApplianceApprovalonlycoverstheuseofdryseasonedwood
logsonthisappliance.HETASApprovaldoesnotcovert heuseofotherfuelseither
aloneormixedwiththewoodlogs,nordoesitcoverinstructionsfortheuseofother
fuels.
Fuel
ThestoveisdesignedandapprovedinaccordancewithEN13240andNS3058for
stokingsplit,driedfirewood.Thefirewoodmusthaveawatercontentof1522%andits
max.lengthshouldbethelengthofthecombustionchamberminus5060mm.
Stokingwithwetfirewoodcausesbothsoot,environmentalpollutionandbadfuel
economy.Freshlycutwoodcontainsapprox.5070%waterandisthoroug hlyunsuitable
forstoking.Allowatleast1yearofstoragetimefornewlycutwoodbeforeusing.Wood
withadiameterofmorethan100mmshouldbesplit.Regardlessofwoodsize,itshould
alwayshaveatleastonesurfaceareafreeofbark.
Wedonotrecommendstoki ngwithpainted,laminatedorimpregnatedwood,woodwith
asyntheticsurface,paintedrefusewood,chipboard,pl ywood,domesticwaste,paper
briquettesandpitcoal,asthiswillproducemalodoroussmoke,whichcouldbe
poisonous.
Whenfiringwiththeabovementioneditemsandamountslargerthanthose
recommended,thestoveissubjectedtoalargeramountofheat,whi chresultsina
higherchimneytemperatureandlowerefficiency.Thiscanresultinthestoveand
chimneybecomingdamagedandwouldvoidthewarranty.
Thecalorificvalueofthefirewoodiscloselyconnectedtothemoisturelevel.
Moistfirewoodhasalowheatvalue.Themorewaterthewoodcontains,themore
energyittakesforthiswatertovaporise,resultinginthisenergybeinglost.
ENGLISH RAISmanualforRaisGabo,Pina,Vola&VolaSoapstone
20
Dryingandstorage
Dryingwoodtakestime:properairdryingtakesapproximately2years.
Herearesometips:
Storethewoodsawn,splitandstackedinanairy,sunnyplace,whichisprotectedagainst
rain(thesouthsideofthehouseisparticularlysuitable).
Storethefirewoodstacksatahand'sbreadthapart,asthisensuresthattheairflowing
throughtakesthemoisturewithit.Avoidcoveringthefirewoodstackswithplastic,asthis
preventsthemoisturefromescaping.Itisagoodideatobringthefirewoodintothehouse
23daysbeforeyouneedit.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

RAIS Vola Soapstone Instructions For Installation, Use And Maintenance Manual

Type
Instructions For Installation, Use And Maintenance Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document