Bticino H4573/2 is a radio actuator that can be used to control rolling shutters, blinds, and other similar loads, either in a traditional electrical system or as part of a Bticino My Home smart home system. It features two-way communication, allowing for status feedback and remote control via radio commands. The device can be programmed to respond to specific radio commands from compatible transmitters, such as remote controls or wall-mounted switches. It also includes a local control button for manual operation.

Bticino H4573/2 is a radio actuator that can be used to control rolling shutters, blinds, and other similar loads, either in a traditional electrical system or as part of a Bticino My Home smart home system. It features two-way communication, allowing for status feedback and remote control via radio commands. The device can be programmed to respond to specific radio commands from compatible transmitters, such as remote controls or wall-mounted switches. It also includes a local control button for manual operation.

DESCRIPTION
7
Power supply: 230V a.c. 50 Hz
Operating temperature:
–5°C ÷ +35°C
Radio frequency:
868 MHz
Range: 100 m in free space
(metal and cement walls or metal plates reduce the range)
8
CONNECTION DIAGRAM
9
TECHNICAL DATA
This radio device can be used, together with other Bticino radio devices, in both a traditional system (to add house-automation
functions) and a Bticino My Home system to make full use of the benefits of radio technology in a mixed radio-wire bus system.
If the radio rolling shutter actuator is used in a traditional system it can be controlled directly by radio actuators or by the local
control on the device. If instead it is used in a My Home system, as well as being directly controlled by radio controls and the local
control, it can be controlled by the system’s wire controls (by means of the transmitting interface L/N/NT4576N HC/HS4576).
DECLARATION OF CONFORMITY
Items L4573/2 and H4573/2 conform to the essential requirements of directive 1999/5/CE, because they respect the following
standards:
ETSI EN 300 220-3 ETSI EN301 489-3 EN60669-2-1
Year of approval of the CE marking according to the directive indicated: 2005
Type of load Max
Incandescent lamps resistive
and motors
2 A
Ferromagnetic transformers
cosf = 0,5
2 A


Light mode Rolling shutter mode
LN LN
H4573/2 L4573/2
C1 = rolling shutters UP
C2 = rolling shutters DOWN
Rear view
Local
pushbuttons
Programming
pushbutton
LED luminous
indicators
Local
pushbuttons
LED luminous
indicator
Programming
pushbutton
GB
Type of system A PL1 PL2 M G
Traditional system
None None None None
, 1
÷4, ⇑⇓M None
My Home system (rolling shutters)
1
÷9
1
÷9 (with PL1 = PL2) None
, 1
÷4, PUL, ⇑⇓M None
, 1
÷9
My Home system (single load)
1
÷9
1
÷9 None None
,O/I
, PUL None
, 1
÷9
CONFIGURATION
10
The radio rolling shutter actuator can be used in both a traditional system and a My Home system.
In both cases it must be first configured and then programmed.
The rolling shutter actuator can be controlled by radio control devices such as remote control item 3527, transmitting radio interface L/N/NT4576N,
HC/HS4576 and radio control item H/L4572.
For the device a mode of operation can be chosen from those listed in the tables below. The device mode of operation is determined by the type
of configurator in socket M.
The relays are interlocked and the 2-module 2-function key cover should always be used.
If the configuration is wrong, once the actuator is connected the LED flashes.
When used in a traditional system, the device can be used to operate rolling shutters, blinds or similar loads. The sockets of configurators A, PL
and G are not used.
When used in a My Home system, the device can be used to operate blinds, rolling shutters and also to operate a single load. In both cases
transmitting radio interface item L/N/NT4576N must be installed and the actuator must be configured putting the correct configurators in the
sockets of configurators A, PL1, PL2 M and G.
If the device is to be used to operate rolling shutters and blinds A, PL1 and PL2 must be configured keeping PL1 = PL2.
If the device is to be used to operate a single load A and PL1 must be configured leaving PL2 not configured. In this case just one relay is used.
For details of the configuration refer to the following tables.
The configuration and/or customisation operations must be performed with the actuator switched OFF.
11
PROGRAMMING
1. Switch on the device.
2. Keep the programming key pressed until the LED lights up (about 4 seconds).
3. Release the key.
4. Within 20 seconds send the signal from the radio control device to be programmed.
Example: For remote control item 3527 press the key to be associated with the actuator.
5. The LED flashes and then goes out, indicating that programming has taken place.
6. Repeat the sequence of operations from point 2 to point 5 for all the radio control devices to be programmed (max 16).
12
CANCELLING
This operation cancels all the radio control devices previously programmed in the actuator.
1.
Switch on the device.
2.
Keep the local key pressed; after 4 seconds the LED lights up, keep the key pressed until the LED goes out.
3.
Release the key.
4.
The LED flashes and then goes out, indicating that all the radio control devices previously programmed in the actuator have been cancelled.
Possible functions
Combination configurator in M and type of key cover
2-module key cover with 1 function 2-module key cover with 2 functions
ON/OFF cyclical None
ON command pressing the upper key, OFF pressing the lower key
O/I
ON/OFF cyclical
(The actuator ignores the Room and General commands)
PUL
Use for single load (Only in My Home system and with PL1 = 1÷9, PL2 = None).
The table below lists the modes of operation for the configurator in position M:
Description
Configurator in M
2-module 2-function key cover
Timed stop for motorisations: the actuator deactivates after the time set:
None = 1 min, 1 = 2 min, 2 = 5 min, 3 = 10 min, 4 = infinite or until the next command
None
, 1
÷4
The actuator ignores the Room and General commands and deactivates after 1 minute
PUL
The actuator is in local monostable mode, while with the radio commands it deactivates after 1 minute
⇑⇓M
Use for rolling shutters (PL1 = PL2): The table below lists the modes of operation for the configurator in position M:
CAUTION! DANGER OF ELECTRIC SHOCK. Only press the programming pushbutton with a phaser or electrically insulated
screwdriver. This operation should only be performed by a trained electrician.
CAUTION! DANGER OF ELECTRIC SHOCK. Only press the programming pushbutton with a phaser or electrically insulated
screwdriver. This operation should only be performed by a trained electrician.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Bticino H4573/2 Operating instructions

Type
Operating instructions
This manual is also suitable for

Bticino H4573/2 is a radio actuator that can be used to control rolling shutters, blinds, and other similar loads, either in a traditional electrical system or as part of a Bticino My Home smart home system. It features two-way communication, allowing for status feedback and remote control via radio commands. The device can be programmed to respond to specific radio commands from compatible transmitters, such as remote controls or wall-mounted switches. It also includes a local control button for manual operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages