Known Issues
Scalar i500 Library Release Notes 9
Change
Request
Number
Service
Request
Number
Description Workaround
28047 Cleaningcountsarereported
inconsistentlywhencleaningtape
isusedintapedrivesfrommultiple
vendors.
Theproblemonlyoccursifyouusethe
samecleaningtapeinbothIBMandHP
tapedrivesbecauseeachvendorreports
cleaningcountdifferently.
28408 IBMLTO-5FCdrivesfailed
firmwareupgradeonalibrarythat
hadanFCI/Obladeinstalled.
Someofthedrivesthatfailedthe
upgradewereconnectedtothe
FCI/Oblade.
Trythefirmwareupgradeoperation
again.
29140 E-mailingAdvancedReportsvia
theWebclientfailstocomplete.
Thisonlyhappenswhenyoufirst
“save”thereportandthen
immediatelytryto“e-mail”the
reportusingtheSaveandE-mail
buttonsinthereportviewer.
Therearetwoworkarounds.Either:
l E-mailthereportbeforesavingit.or
l Onceyousavethereport,leavethe
reportviewerpageandgotoanother
pageintheWebclient.Returntothe
reportviewerpageandthenclickthe
E-mailbuttontoe-mailthereport.
29297 SR1148738 Pickerissuescausetheoperator
paneltoremaininthe“working”
state.
LogontotheWebclient,capturea
snapshot,andcontactQuantumSupport
forassistance.
31724 Cannotchangedrivetopology
settingafterdisablingdatapath
failover.
Refreshthewebbrowserpagebefore
attemptingtochangetopology.
32239 EKMPathDiagnosticsfailswhen
youchangetheDNShostnameof
aprimaryorsecondaryEKM
server(Setup > Encryption >
System Configuration).This
occurswhenchangingtheDNS
hostnametoanotherhostname,
orwhenchanginganIPaddressto
aDNShostname.
Afteryouchangethehostname,restart
thelibrary.