Quantum Scalar i500 Release Notes

Category
Tape auto loaders & libraries
Type
Release Notes
ReleaseNotes
Release Scalari500Libraryi8.3(660.GS007)
Supported Web Browsers
(Remote Web Client)
l Microsoft®InternetExplorer8.0and9.0
l MozillaFirefox™16andlaterversions
Date February2015
Contents
PurposeofthisRelease 2
NewFeaturesandEnhancements 2
GeneralUsageNotes 2
SecurityScanners 3
CompatibilityandSupport 3
EncryptionKeyManagementTapeDriveandMediaSupport 4
FirmwareCompatibility 5
SoftwareCompatibility 6
ResolvedIssues 6
KnownIssues 8
© 2015 Quantum Corporation. All rights reserved. Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo,
SuperLoader, Scalar, DXi, StorageCare, StorNext, GoProtect, and Vision are registered trademarks of Quantum Corporation
and its affiliates in the United States and/or other countries. All other trademarks are the property of their respective owners.
Quantum specifications are subject to change.
6-01378-35 Rev A, February 2015
*6-01378-35*
Purpose of this Release
Scalar i500 Library Release Notes 2
FirmwareVersions 11
Documentation 12
ContactingQuantum 13
PurposeofthisRelease
TheScalari500Libraryi8.3(660.GS007)releaseincludesbugfixes.Thesereleasenotesdescribethese
bugfixes,aswellascurrentlyknownissues.Thesenotesalsoprovidetapedriveandauxiliaryfirmware
compatibilityinformation.Visithttp://www.quantum.comforadditionalinformationabouti500.
NewFeaturesandEnhancements
Scalari500Libraryi8.3(660.GS007)includesbugfixesintroducedinScalari500Libraryi8.3.
GeneralUsageNotes
ThefollowingareimportantitemsnotcoveredintheKnownIssuessectionofthisdocument.
l Internet Browser "Back" Button—ThelibraryWebclientdoesnotsupportusingtheInternetbrowser
"back"buttons.Instead,usetheBackandCancelbuttonsprovidedintheuserinterface.
l Internet Browser MenusTheWebbrowsermayintermittentlyfailtodisplaymenusproperly.
Alternatively,someelementsonafewofthepagesmayobscuresomemenuitemswhenviewingin
InternetExplorer.
l Library Configuration Changes Upon DowngradeAfterafirmwaredowngrade,library
configuration(partitionnames,slotcounts,I/Estationslotcount,etc.)maychange.Witheachsuccessive
firmwarerelease,newfeaturesaresupportedandrepresentedinthecurrentconfigurationfilethatmay
notbebackward-compatibletopreviousreleases.Anecessarypartoffirmwaredowngradeisto
automaticallyresettheunittothedefaultconfiguration.Thelibrarymustbereconfiguredtotheuser-
definedsettingswhenthefirmwaredowngradeiscomplete.
l Upgrading Library FirmwareWhenplanningtoupgradelibraryfirmware,upgradedrivefirmware
firstbeforeupgradingthelibraryfirmware.Ifyouareplanningtodowngradethelibraryfirmware,
downgradethedrivefirmwarefirstbeforedowngradingthelibraryfirmware.
Security Scanners
Scalar i500 Library Release Notes 3
l SNMP MIBSNMPMIBwalksonlargelibraryconfigurations(likea41U)maytimeoutat5seconds,
butwillpassat10seconds.WhenperforminganSNMPMIBwalk,makesurethatyourutilityretrieves
MIBinformationusingatimeoutofatleast10seconds.
l EDLM and StorNext Partitions (StorNext)LibrarypartitionsconfiguredforEDLMandthe
StorNextApplicationProgrammingInterface(SNAPI)plug-inneedtoconfigurethepartitionMedia
BarcodeFormatto“Standard”(reportmediabarcodelabelwithoutthemediaidentifier)sothatany
library-initiatedmediacopyoperationscansucceed.
l Changing the time or time zone by more then 2 hoursIfyouchangethetimeortimezoneonthe
librarybymorethen2hoursfromitscurrentsetting,itisrecommendedthatyourebootthelibrary.There
aretimersinthelibraryfirmwarethatarenotupdatedbythetimechangeandcancauseunexpected
behavioriflargetimechangesoccurwithoutrestartingthelibrary.
l Planning a Drive Firmware UpgradeWhenupdatingIBMLTO-6tapedrivefirmware,theupdate
processcantakeatleast2hourstocomplete.Donotstoporinterruptthefirmwareupgradeprocess;
planyourfirmwareupgradeaccordingly.
l Cookie Placement for LoginTheWebclientplacesacookieontheuser’scomputertoprovidethe
lastuser’scredentialsuponlogin.Thecookieonlycollectstheuser’scredentialstofacilitatelogin,and
doesnotcollectanyotheruserdata.
SecurityScanners
TenableNetworkSecurity®Nessus®version6.2.0securityscannerwasrunagainstthelibraryfirmware
andfoundnocriticalissues.
CompatibilityandSupport
Thissectionprovidesinformationonfirmwareandsoftwarecompatibility.
Compatibility and Support
Scalar i500 Library Release Notes 4
EncryptionKeyManagementTapeDriveandMedia
Support
Thelibrarysupportsthefollowingencryptionsystems:
Encryption System Supported Tape Drives Supported Media
QuantumEncryptionKey
Manager(Q-EKM)
IBMLTO-4FC
IBMLTO-4SAS
IBMLTO-5FC
IBMLTO-5SAS
IBMLTO-6FC
IBMLTO-6SAS
YoumustberunningQ-EKMversion2.0
(orhigher)tosupportIBMLTO-5orLTO-6
tapedrives.
LTO-4,LTO-5,andLTO-6tape
cartridgesonly
Tivoli/SecureKeyLifecycle
Manager(TKLM/SKLM)
IBMLTO-4FC
IBMLTO-4SAS
IBMLTO-5FC
IBMLTO-5SAS
IBMLTO-6FC
IBMLTO-6SAS
Encryptionkeymanagementissupported
viatheIBMproprietaryprotocol(IPP)and
nottheKMIPcommunicationprotocol.
LTO-4,LTO-5,andLTO-6tape
cartridgesonly
ScalarKeyManager(SKM) HPLTO-4FC
HPLTO-4SAS
HPLTO-5FC
HPLTO-5SAS
HPLTO-6FC
HPLTO-6SAS
IBMLTO-5FC
IBMLTO-5SAS
IBMLTO-6FC
IBMLTO-6SAS
LTO-4,LTO-5,andLTO-6tape
cartridgesonly
Compatibility and Support
Scalar i500 Library Release Notes 5
Encryption System Supported Tape Drives Supported Media
KMIP-compliantkeymanagers*
HPLTO-4FC
HPLTO-4SAS
HPLTO-5FC
HPLTO-5SAS
HPLTO-6FC
HPLTO-6SAS
IBMLTO-5FC
IBMLTO-5SAS
IBMLTO-6FC
IBMLTO-6SAS
LTO-4,LTO-5,andLTO-6tape
cartridgesonly
*TheKeyManagementInteroperabilityProtocol(KMI)isaspecificationdevelopedbyOASIS®.Itsfunctionis
tostandardizecommunicationbetweenenterprisekeymanagementsystemsandencryptionsystems.TheScalar
i500libraryprovidesaKMIPversion1.2compliantencryptionsolution.
FirmwareCompatibility
ThefollowingtableprovidesinformationabouttapedrivefirmwarecompatibilitywithScalari500Libraryi8.3
(660.GS007).Thisinformationiscurrentasofthepublicationdateofthesereleasenotes.Forthemost
recentfirmwareversions,checkwww.quantum.com.ForthemostuptodateinformationonQuantum
GlobalServices,pleasevisit:www.quantum.com/support.
i
Note: Scalari500librarieswithIBMLTO-5andLTO-6tapedrivesmustbeatlibrarycodeversioni8.2.3
(648G.GS005)beforeinstallingtheIBMLTO-5E6Q0and/orLTO-6E6R0tapedrivefirmware.
Drive Type Firmware Version
HPLTO-4FC H64Z
HPLTO-4SAS A65Z
HPLTO-5FC I6GZ
HPLTO-5SAS X6CZ
HPLTO-6FC J53Z
HPLTO-6SAS O53Z
IBMLTO-2FC A4N0
Resolved Issues
Scalar i500 Library Release Notes 6
Drive Type Firmware Version
IBMLTO-2SCSI A4N0
IBMLTO-3FC 93GM
IBMLTO-3SCSI 93GM
IBMLTO-4FC C7QH*
IBMLTO-4SAS C7QH*
IBMLTO-4SCSI C7QH*
IBMLTO-5FC E6Q0
IBMLTO-5SAS E6Q0
IBMLTO-6FC E6R6
IBMLTO-6SAS E6R6
*Duetosecurityfeatures,youcannotdowngradetheIBMLTO-4drivefirmwaretoversionspriorto82FBwithout
followingspecificinstructions.Ifyoumustdowngrade,contactQuantumSupportforassistance.
SoftwareCompatibility
ToviewalistofbackupsoftwarepackageswhichhavebeentestedforinteroperabilitywiththeScalari500
Libraryi8.3(660.GS007),seetheQuantumSoftwareCompatibilityGuideat
http://www.quantum.com/swcompguide.aspx.
ResolvedIssues
ThisreleaseofScalari500Libraryi8.3(660.GS007)firmwareresolvedthefollowingissues.
Change
Request
Number
Service Request
Number
Description Solution
51697 SR3369784 TheCBCmodeciphershadasecurityvulnerabilityand
shouldberemoved.
Resolved.
Resolved Issues
Scalar i500 Library Release Notes 7
Change
Request
Number
Service Request
Number
Description Solution
52080,
53681
SR3396986,
SR3445462
SSLserverallowsanonymousAuthentication
VulnerabilityperthePoodleVulnerability.
Resolved.
52297 SR3404188 TheRC4ciphershadasecurityvulnerabilityandshould
beremoved.
Resolved.
53302 SR3445462 Updateopensourcesoftwareopenssl-1.01jtoresolve
opensecurityvulnerabilities.
Resolved.
53407 SR3449340 User'sLDAPpasswordispresentedastextinthe
RemoteUserInterfacelog.
Resolved.
53470 Thediskspacecleanscriptwasrunningwhentheuser
viewedtheUpdateLibraryFirmwarepageinsteadof
whentheuseractuallyupdatesthelibraryfirmware.
Resolved.
54068 UpdateopensourcesoftwareOpenSSH_6.7p1to
resolveopensecurityvulnerabilities.
Resolved.
Known Issues
Scalar i500 Library Release Notes 8
KnownIssues
ThisreleaseofScalari500Libraryi8.3(660.GS007),firmwarehasthefollowingknownissues.
Change
Request
Number
Service
Request
Number
Description Workaround
22967 Whenupgradingalibrarywitha
Model2robottofirmwareversion
570G,thelibrarymaygenerate
RASticketT124 - Robotics
Hardware Error - RCB.
Explanation:Theproblemhasbeen
fixedincodeversions570Gandlater,
butbecausetheproblemresidesin
previouscodeversions,youmay
encounterthisissuewhenupgrading
fromapreviousversiontoversion570G.
Workaround:Leavethelibrarypowered
onfor20minutesaftertheticketwas
postedtoallowthepickertorecover.If
youopenalibrarydoororpowercycle
thelibraryduringthistime,thepicker
maybecomeinoperableandrequire
replacement.
25651 Ifatapedrivefirmwareupdatefails
whenusingafirmwareupdate
methodotherthanautoleveling,
thelibrarymayincorrectly
generateRASticketT112 -
Invalid Tape Drive Firmware
Imageinadditiontocorrectly
generatingRASticketT109 -
Tape Drive Firmware Update
Failure.
IgnoreT112,andfollowtheresolution
stepsforT109.
25964 SR1070246 Ifalibraryisupgradedandfailsto
initializeuponreboot,thesnapshot
namewillbeincorrect.
Snapshotinformationiscorrectother
thanthename.Correctthehardware
issuethatiscausinglibrarynotto
initialize.
27092 OccasionallytheFCI/Oblade
serialnumberisreported
incorrectlyontheTools-FCI/O
BladeInformationscreen(Tools >
FC I/O Blade Info).
Iftheserialnumberendswithinvalid
characters,ignoretheinvalid
characters.Therestoftheserialnumber
iscorrect.
Known Issues
Scalar i500 Library Release Notes 9
Change
Request
Number
Service
Request
Number
Description Workaround
28047 Cleaningcountsarereported
inconsistentlywhencleaningtape
isusedintapedrivesfrommultiple
vendors.
Theproblemonlyoccursifyouusethe
samecleaningtapeinbothIBMandHP
tapedrivesbecauseeachvendorreports
cleaningcountdifferently.
28408 IBMLTO-5FCdrivesfailed
firmwareupgradeonalibrarythat
hadanFCI/Obladeinstalled.
Someofthedrivesthatfailedthe
upgradewereconnectedtothe
FCI/Oblade.
Trythefirmwareupgradeoperation
again.
29140 E-mailingAdvancedReportsvia
theWebclientfailstocomplete.
Thisonlyhappenswhenyoufirst
save”thereportandthen
immediatelytrytoe-mail”the
reportusingtheSaveandE-mail
buttonsinthereportviewer.
Therearetwoworkarounds.Either:
l E-mailthereportbeforesavingit.or
l Onceyousavethereport,leavethe
reportviewerpageandgotoanother
pageintheWebclient.Returntothe
reportviewerpageandthenclickthe
E-mailbuttontoe-mailthereport.
29297 SR1148738 Pickerissuescausetheoperator
paneltoremaininthe“working
state.
LogontotheWebclient,capturea
snapshot,andcontactQuantumSupport
forassistance.
31724 Cannotchangedrivetopology
settingafterdisablingdatapath
failover.
Refreshthewebbrowserpagebefore
attemptingtochangetopology.
32239 EKMPathDiagnosticsfailswhen
youchangetheDNShostnameof
aprimaryorsecondaryEKM
server(Setup > Encryption >
System Configuration).This
occurswhenchangingtheDNS
hostnametoanotherhostname,
orwhenchanginganIPaddressto
aDNShostname.
Afteryouchangethehostname,restart
thelibrary.
Known Issues
Scalar i500 Library Release Notes 10
Change
Request
Number
Service
Request
Number
Description Workaround
32278 IfbothFCI/ObladesandEthernet
Expansionbladesareinthelibrary,
whenyouperformanoperation
thatrebootsallinstalledFCI/O
blades,itwillalsoresetall
installedEthernetExpansion
blades.TheEEbladeresetmay
generateaRASticketT177 - EEB
lost Ethernet/CAN connectivity.
ClosetheEEBRASticket.Verifythat
nootherrelatedRASticketswere
generated.
32352 Changingthelibrary’sinternalIP
addressinthemidstofahost-
initiatedbackup/restoreoperation
maycausethebackuptofail.
Donotchangethelibrary’sinternalIP
addressduringbackup/restore
operations.Itisrecommendedpractice
torebootthelibraryafterchangingthe
internalIPaddress.Additionally,you
mayreceiveRASticketsforlossof
drivecommunicationifyouchangethe
internalIPaddress.Ifthisoccurs,
resolveanyrelatedRAStickets,and
thenrebootthelibrary.
37926 Afterrestoringtoaprevious
releaseversionandthenupgrading
toi8,thefollowingRASmessages
weregenerated:
l T084 - Missing Cleaning
Tape
l T085 - Unknown Cartridge In
Cleaning Slot
Exportallcleaningtapesandre-import
thembackintoconfiguredcleaning
slots.
41384 Onlibraryfirmwareupgradesitis
possibletoseeticketT074 –
Drive Sled Auto-Leveling
Failure.
CloseRASticketT074 – Drive Sled
Auto-Leveling Failure.Powercycle
thelibrary.
48262/40715 Afterupgradingthelibraryfrom
versioni8.1.1toi8.2,thelibrary
maydisplayanerrorwhen
accessingpagesfromtheWeb
clientmenu.
Rebootthelibrary.
Firmware Versions
Scalar i500 Library Release Notes 11
Change
Request
Number
Service
Request
Number
Description Workaround
50737 Usinganinvalidcleaningtapefor
AutomaticCleaningdoesnot
generateerrorsonthelibrary.
Verifythatonlyvalidcleaningtapesare
usedforcleaningoperations.
54573 WithVision4.3.2orolder,
monitoredScalarlibrariesmay
moveintoaconnectionfailed()
statusafterafirmwareupgrade.
Thischangeofstatusmayalso
occurwithnewlydiscovered
Scalarlibrariesiftheyarerunninga
newfirmwareversion..
UpdatedVision4.3.3tocorrectly
monitorScalarlibrarieswithnew
versionsoffirmware.Werecommend
upgradingyourVisionsoftwaretoVision
4.3.3.
FirmwareVersions
Thetablebelowlistsfirmwarecodeforthelastseveralreleases.
Release Scalar i500
Library
Firmware
Board Support
Package (BSP)
UDS Firmware Fibre-
Channel I/O
Blade
Firmware
i8.3 660G.GS007 8.64 777Q.GU002with430A.GU001boot 5.12.01.33
i8.2.3 648G.GS005 8.4 777Q.GU002with430A.GU001boot 5.12.01.33
i8.2.2.1 646G.GS002 8.37 776Q.GU001with430A.GU001boot 5.12.01.33
i8.2.1.1 643G.GS002 8.32 745Q.GU007with430A.GU001boot 5.12.01.33
i8.2 640G.GS007 8.32 745Q.GU007with430A.GU001boot 5.12.01.33
i8.1.2 636G.GS003 8.14 740Q.GU033with430A.GU001boot 5.12.01.33
i8.1.1 635G.GS005 8.13 740Q.GU033with430A.GU001boot 5.12.01.33
i8 630G.GS003 8.09 740Q.GU033with430A.GU001boot 5.12.01.33
i7.3 620G.GS010 7.90 723Q.GU024with430A.GU001boot 5.12.01.08
i7.2 607G.GS004 7.66 713Q.GU004with430A.GU001boot 5.10.08.07
Documentation
Scalar i500 Library Release Notes 12
Release Scalar i500
Library
Firmware
Board Support
Package (BSP)
UDS Firmware Fibre-
Channel I/O
Blade
Firmware
i7 600G.GS004 7.42 710Q.GU012with430A.GU001boot 5.10.08.07
i6.1 585G.GS003 6.86 655Q.GU005with430A.GU001boot 5.10.02.01
i6 580G.GS003 6.80 650Q.GU014with430A.GU001boot 5.10.02.01
i5.1 571G.GS002 6.73 630Q.GU008with430A.GU001boot 5.09.05.01
i5 570G.GS025 6.73 630Q.GU008with430A.GU001boot 5.09.05.01
i4 520G.GS003 6.66 610Q.GU005with430A.GU001boot 5.08.08.01
i3.1 500G.GS004 6.53 591Q.GU004with430A.GU001boot 5.08.02.01
i3 500G.GS002 6.52 590Q.GU001with430A.GU001boot 5.08.02.01
SP4.2 420G.GS005 6.42 570Q.GU002with430A.GU001boot 5.07.11.01
420G.GS006 6.42 570Q.GU002with430A.GU001boot 5.07.11.02
SP4 410G.GS007 6.39 550A.GU003with430A.GU001boot 5.07.09.01
i2 400G.GS010 6.32 530A.GU004with430A.GU001boot 5.07.05.04
Documentation
Documentationpertainingtothisproductislocatedat:
http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/SI500/Index.aspx#
Documentation
Document Number Document Title
6-01733-05 Scalari500SitePlanningGuide
6-01210-06 Scalari500User’sGuide
6-01741-04 Scalari500GettingStartedGuide
6-67926-01 Scalari500RepackagingInstructions
6-01370-10 Scalari500BasicSNMPReferenceGuide
Contacting Quantum
Scalar i500 Library Release Notes 13
Document Number Document Title
6-00423-13 QuantumIntelligentLibrariesSCSIReferenceGuide
6-01317-10 QuantumIntelligentLibrariesSMI-SReferenceGuide
6-01739-08 Scalari500LibraryFirmwareUpgradeInstructions
6-01740-07 Scalari500TapeDriveFirmwareUpgradeInstructions
6-01844-03 LibraryServiceUtilityInstallationInstructions
6-00618-11 System,Safety,andRegulatoryInformationGuide
DocumentationpertainingtotheStorNextAEL500productislocatedat:
http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/AEL500/Index.aspx
Document Number Document Title
6-67853-02 StorNextAEL500MiniEssentialsGuide
ContactingQuantum
MoreinformationaboutthisproductisavailableontheServiceandSupportwebsiteat
http://www.quantum.com/ServiceandSupport/Index.aspx.TheServiceandSupportWebsitecontainsa
collectionofinformation,includinganswerstofrequentlyaskedquestions(FAQs).Youcanalsoaccess
software,firmware,anddriversthroughthissite.
Forfurtherassistance,oriftrainingisdesired,contacttheQuantumCustomerSupportCenter:
Region Support Contact
UnitedStates 1-800-284-5101(tollfree)
+1-720-249-5700
EMEA +800-7826-8888(tollfree)
+49-6131-3241-1164
APAC +800-7826-8887(tollfree)
+603-7953-3010
Forworldwidesupport:
http://www.quantum.com/serviceandsupport/index.aspx
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Quantum Scalar i500 Release Notes

Category
Tape auto loaders & libraries
Type
Release Notes

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI