Infinity Interlude IL120s User manual

Category
Subwoofers
Type
User manual

This manual is also suitable for

Interlude Series
IL120s Subwoofer
Service Manual
Infinity Systems, Inc
250 Crossways Park Dr.
Woodbury, New York 11797
REV 1 10/2001
IL120s
CONTENTS
SPECIFICATIONS …….…………………………….………………….3
DETAILED SPECIFICATIONS ……………………..…………………4
CONTROLS and CONNECTIONS ………………….….….…………6
OPERATION……………………………………..……..…..…….……..8
BASS OPTIMIZATION SYSTEM…………….………….….…………9
MECHANICAL/PACKING PARTS LIST………………..……………11
EXPLODED VIEW ……………………………………….……………12
PACKAGING …………………………….………………………….…13
EXPLODED VIEW OF AMPLIFIER…………………….……………14
TEST SETUP and PROCEDURE……………….……..……………15
IL120s ADJUST BIAS PROCEDURE…..16
PRINTED CIRCUIT BOARD DIAGRAMS………………..…………17
ELECTRICAL PARTS LIST (120v)…………………….….…………23
INTEGRATED CIRCUIT DIAGRAMS ………………………………31
IL120s SCHEMATICS…………..……….……………………………32
IL120s
3
SPECIFICATIONS
IL120s Frequency Response: 28Hz - 150Hz (±3dB)
Maximum Amplifier Output: 500 watts (20Hz - 150Hz with no more than 0.1% THD)
Crossover Frequencies: 50Hz - 150Hz, 24dB/octave, continuously variable
Driver: 12" C.M.M.D.
Dimensions (H x W x D): 17-1/2" x 17-1/4" x 19-3/4"
Weight: 45 lb (20.5kg)
Optional Accessory: Bass Optimization
Test & Measurement Kit:
Part Number: 335852-002
DETAILED SPECIFICATIONS
IL120s
4
IL120s
5
DETAILED SPECIFICATIONS (Cont.)
IL120s
6
CONTROL and CONNECTIONS
IL120s
7
CONNECTIONS
IL120s
8
OPERATION
IL120s
9
BASS OPTIMIZATION SYSTEM
TM
IL120s
10
BASS OPTIMIZATION SYSTEM
TM
(Cont.)
plays the tones from the test CD and records the relative output level of each test tone, using the sound-level meter,
on the provided measurement template. After all the tones are complete, the template contains a response curve
for the frequencies below 100Hz. The user simply notes the frequency of the largest bass peak, calculates the cor-
rect amount of attenuation, and uses the “Q-Finder” to determine the width of the curve. These three values are
dialed into the Bass Optimization System controls located on the speaker. The entire process takes less than twen-
ty minutes.
If your dealer does not stock the Bass Optimization System test and measurement kit, you may purchase it directly
from Infinity. U.S. residents can visit our Web site at www.infinitysystems.com or call 1-800-553-3332. Canadian
residents should contact their dealer or call 1-800-567-3275.
Ask for Infinity part number 335852-002.
IL120s
11
MECHANICAL/PACKAGING PARTS LIST
MECHANICAL
IL120s COMPLETE AMPLIFIER ASSY N/A
WOOFER, 12”, C.M.M.D., shielded, 3.4 ohms ±10% 336056-001
VOLUME CONTROL, R-IL 336250-001
FRONT BAFFLE 336439-001
PORT TUBE 336799-001
GRILLE CUP (12) 333249-003
GRILLE, GRAY 336441-001
GRILLE, MIDNIGHT BLUE 336441-002
GRILLE, RICH BURGUNDY 336441-003
GRILLE, BLACK 336441-004
PACKAGING
OWNER’S MANUAL, IL100S/IL120S 335839-001
WARRANTY CARD 335841-001
SURVEY CARD 330033-001
CARTON 336497-001
FOOT (4) 334186-002
FOOT PAD (4) 334192-001
PAD, END, TOP 336496-001
PAD, END, BOTTOM 336496-002
GRILLE ASSEMBLY See Options Above
POWER CORD, 120V US-15’ 336658-115
RABOS SCREW DRIVER 335848-002
Description Part Number
IL120s
12
EXPLODED VIEW
CABINET
(NOT FOR SALE)
WOOFER, 12"
(336056-001)
VOLUME CONTROL, R-IL
(336250-001)
FRONT BAFFLE
(336439-001)
PORT TUBE
(336799-001)
GRILLE CUP (6)
(333249-003)
GRILLE CUP (6)
(333249-003)
GRILLE, GRAY 336441-001
GRILLE, MIDNIGHT BLUE 336441-002
GRILLE, RICH BURGUNDY 336441-003
GRILLE, BLACK 336441-004
FOOT (4)
(334186-002)
FOOT PAD (4)
(334192-001)
OO514
IL120s
AMPLIFIER ASSY
(NOT FOR SALE)
TO SERVICE THE IL120s SUBWOOFER
1) Remove the grille.
2) Extract (6) rubber grille retainers as shown in the illustration above, this can be accomplished by
carefully pulling them out of the cavities with long-nosed pliers or similar tool.
3) Remove the (6) Phillips screws that are now exposed.
4) Remove the front baffle.
5) Remove the (6) screws that secure the driver.
6) To service the amplifier, remove the (12) Phillips screws at the rear of the enclosure, and pull the
amplifier out of the back.
SCREW, (2)
#6 x .75, PB, PPH, BLK
(903401-012)
SCREW, (6)
#6 x .75, PB, PPH, BLK
(903401-012)
SCREW, (12)
#8 x .75, PB, PPH BLK
(900101-012)
SCREW, (6)
#8 x .75, PB, PPH BLK
(900101-012)
SCREW,
#8 x 1, PB TRPH BLK
(903101-016)
IL120s
13
PACKAGING
OWNER'S MANUAL
IL100S/IL120S
(335839-001)
WARRANTY CARD
(335841-001)
SURVEY
CARD
(330033-001)
POWER CORD,
120V US-15'
(336658-115)
RABOS SCREW
DRIVER
(335848-002)
GRILLE ASSEMBLY,
GRAY,
(336441-001)
PAD, END, TOP
(336496-001)
PAD, END, BOTTOM
(336496-002)
CARTON
(336497-001)
00513
IL120s
14
EXPLODED VIEW OF AMPLIFIER
LINEAR
BOARD
FEATURE
BOARD
RABOS
BOARD
POWER
SUPPLY
BOARD
RCA
QUADJACK
(JC0052)
SWITCH, (4)
SPDT TOGGLE
(SR0007)
BINDING
POSTS GOLD
(JC0104)
FUSE HOLDER
PANEL MT SEALED
(FH0012)
FUSE, 4A 250V
1.25X.25 SLO-BLO
(FS0026)
AC (120V)
IEC SOCKET
(JC0129)
SWITCH,
ROCKER POWER
(SR0032)
FRONT VIEW
EMI
BOARD
®
®
O
00515
IL120s
15
TEST SETUP and PROCEDURE
00516
SIGNAL
GENERATOR
AMPLIFIER
AC VOLT
METER (10V)
IL120s
UNDER TEST
OUTPUT
FROM
GENERATOR/AMPLIFIER
00345
®
®
O
R
SYSTEM AURAL SWEEP TEST
Equipment needed:
• Function/signal generator/sweep generator
• Integrated Amplifier
• Multimeter
• Speaker cables
General Unit Function (UUT = Unit Under Test)
Switches/knobs on the amplifier faceplate:
Input Select to “Line”
Low Pass Filter to OFF
Bass Optimization system to OFF
Low Pass Frequency Adjust full CW (150Hz)
Phase switch – either position
1. From the signal generator, Connect both right and left line level inputs (RCA) to signal generator and UUT. Use Y-cable if
necessary from mono source.
2. On the front of the unit, turn the LEVEL control full clockwise (0).
3. Turn on generator, adjust to 120mV, 30 Hz.
4. Plug in UUT; turn the power switch ON. LED should be Red. Turn LEVEL control full counterclockwise (10)
5. LED should now be Green; immediate bass response should be heard and felt from rear port tube opening.
6. Turn off generator, turn LEVEL control fully clockwise (0), disconnect RCA cable.
7. Connect one pair of speaker cables to Speaker Level input terminal on UUT. Cables should be connected to an integrated
amplifier fed by the signal generator.
8. Switch Input to “Speaker”.
9. Turn on generator and adjust so that speaker level input at the amplifier is 2.2V, 30 Hz. Turn LEVEL control full counter-
clockwise (10)
10. Green LED should light, immediate bass response should be heard and felt from the port tube opening.
Sweep Function
1. Follow steps 7-10 above, using a sweep generator as a signal source.
2. Sweep generator from 20Hz to 20kHz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or any other noises. If
any unusual noises are heard, remove woofer and test.
Driver Function (Woofer)
1. Remove woofer from cabinet; detach + and - wire clips. See page 12 for removal instructions.
2. Check DC resistance of woofer; it should be 3.4 ohms±10%.
3. Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier fed by a signal
generator. Turn on generator and adjust so that speaker level output is 5.0V.
4. Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.
IL120s ADJUST BIAS PROCEDURE
(Mandatory when any output MOSFET transistors Q3,4,7,8 are replaced)
1. Amplifier should be unplugged and OFF.
2. Remove Amp assembly from cabinet; remove rear plastic cover if present. All wires exiting
the cover can remain connected unless they will prevent you from removing the amplifier or
accessing potentiometers on the Linear board PCB in the following steps.
3. Locate the Linear board assembly (PCB with the output transistors)
4. Adjust R11 and R27 fully Counter Clockwise. See diagram below.
5. Apply 120 VAC power to unit, Turn power switch ON.
6. Verify LED illuminates on the front gain control dial unless you have disconnected the plug.
7. Connect voltmeter set to DC millivolt range to twin pins on terminal J7, on Linear board
8. Verify initial voltage is less then 0.1 mV.
9. Adjust R11 Clockwise until voltmeter reads 0.3 mV + the initial current from step #8.
10. Adjust R27 Clockwise until voltmeter now reads 0.6 mV + the initial current from step #8.
11. Turn amplifier OFF. Disconnect AC power to unit.
12. Remove voltmeter from terminal J7.
13. Replace cover (if present), wires if disconnected, and replace amplifier back into cabinet.
16
IL120s
17
IL VOLUME RIGHT BOARD
IL120s
18
EMI FILTER BOARD
IL120s
19
IL FEATURE BOARD
IL120s
20
IL RABOS BOARD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Infinity Interlude IL120s User manual

Category
Subwoofers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI