ABB HA-S-2-WL User manual

Category
Thermostats
Type
User manual

This manual is also suitable for

2CKA001473B9364 16.10.2017
Product manual
ABB-free@home
®
Radiator thermostat, Basic
HA-S-1-WL
Radiator thermostat, Comfort
HA-S-2-WL
Table of contents
Product manual 2CKA001473B9364
2
Table of contents
1
Information on the manual .......................................................................................................................... 3
2
Safety ......................................................................................................................................................... 4
2.1
Information and symbols used ........................................................................................................ 4
2.2
Intended use ................................................................................................................................... 5
2.3
Improper use ................................................................................................................................... 5
2.4
Target group / Qualifications of personnel ...................................................................................... 5
2.5
Safety instructions ........................................................................................................................... 6
2.6
Use of batteries ............................................................................................................................... 6
2.7
Environment .................................................................................................................................... 6
3
Setup and function ..................................................................................................................................... 7
3.1
Scope of supply .............................................................................................................................. 8
3.2
Additional necessary components ................................................................................................... 8
3.3
Overview of types ........................................................................................................................... 9
3.4
Functions ........................................................................................................................................ 9
3.5
Device overview ............................................................................................................................ 11
4
Technical data .......................................................................................................................................... 12
4.1
Dimensional drawings ................................................................................................................... 13
5
Connection and installation ...................................................................................................................... 14
5.1
Installation ..................................................................................................................................... 14
5.2
Dismantling ................................................................................................................................... 17
6
Commissioning ......................................................................................................................................... 18
6.1
Coupling of wireless devices with the System Access Point ......................................................... 18
6.2
Allocation of devices and definition of channels ............................................................................ 20
6.3
Setting options per channel ........................................................................................................... 25
6.4
Links .............................................................................................................................................. 28
7
Update ...................................................................................................................................................... 29
8
Operation ................................................................................................................................................. 30
8.1
Setpoint adjustment or change of mode ........................................................................................ 30
8.2
Special features during operation ................................................................................................. 32
8.3
Displays / messages ..................................................................................................................... 34
9
Maintenance ............................................................................................................................................. 35
9.1
Cleaning ........................................................................................................................................ 35
10
Notes ........................................................................................................................................................ 36
11
Index ........................................................................................................................................................ 37
Information on the manual
Product manual 2CKA001473B9364
3
1 Information on the manual
Please read this manual carefully and observe the information it contains. This will assist you in
preventing injuries and damage to property, and ensure both reliable operation and a long
service life for the device.
Please keep this manual in a safe place.
If you pass the device on, also pass on this manual along with it.
ABB accepts no liability for any failure to observe the instructions in this manual.
If you require additional information or have questions about the device, please contact ABB or
visit our Internet site at:
www.abb.com/freeathome
Safety
Product manual 2CKA001473B9364
4
2 Safety
The device has been constructed according to the latest valid regulations governing technology
and is operationally reliable. It has been tested and left the factory in a technically safe and
reliable state.
However, residual hazards remain. Read and adhere to the safety instructions to prevent
hazards of this kind.
ABB accepts no liability for any failure to observe the safety instructions.
2.1 Information and symbols used
The following Instructions point to particular hazards involved in the use of the device or provide
practical instructions:
Danger
Risk of death / serious damage to health
The respective warning symbol in connection with the signal word "Danger"
indicates an imminently threatening danger which leads to death or serious
(irreversible) injuries.
Warning
Serious damage to health
The respective warning symbol in connection with the signal word "Warning"
indicates a threatening danger which can lead to death or serious
(irreversible) injuries.
Caution
Damage to health
The respective warning symbol in connection with the signal word "Caution"
indicates a danger which can lead to minor (reversible) injuries.
Attention
Damage to property
This symbol in connection with the signal word "Attention" indicates a
situation which could cause damage to the product itself or to objects in its
surroundings.
NOTE
This symbol in connection with the word "Note" indicates useful tips and
recommendations for the efficient handling of the product.
This symbol alerts to electric voltage.
Safety
Product manual 2CKA001473B9364
5
2.2 Intended use
The radiator thermostats Basic and Comfort can be used to create a convenient single room
control by operating the radiator heating via wireless signal. The radiator thermostats are fully
compatible with radiator valves with an M30 x1.5 thread. For other valves (e.g. Danfoss), one of
the supplied adapters must be used.
Only AA alkaline batteries are permitted for use. The scope of delivery includes 2 batteries.
The device is intended for the following:
Operation according to the listed technical data
Installation in dry interior rooms
The intended use also includes adherence to all specifications in this manual.
Declaration of conformity
Busch-Jaeger | ABB, herewith declare that radio system types HA-S-1-WL and HA-S-2-WL
conform to directive 2014/53EU.
The complete text of the EU declaration of conformity is available at the following Internet
address:
HA-S-1-WL www.busch-jaeger-catalogue.com/6200-0-0133,artikel.html
HA-S-2-WL www.busch-jaeger-catalogue.com/6200-0-0134,artikel.html
Tab.1: Link to Declaration of conformity
2.3 Improper use
Each use not listed in Chapter 2.2 “Intended use“ on page 5 is deemed improper use and can
lead to personal injury and damage to property.
ABB is not liable for damages caused by use deemed contrary to the intended use of the
device. The associated risk is borne exclusively by the user/operator.
The device is not intended for the following:
Unauthorized structural changes
Repairs
Outdoor use
The use in bathroom areas
2.4 Target group / Qualifications of personnel
No special qualifications are needed to connect and operate the device.
However, persons installing or connecting and operating the device must have read and
understood the manual and follow the instructions provided.
Safety
Product manual 2CKA001473B9364
6
2.5 Safety instructions
Warning - Risk of sustaining injuries!
An improper use of batteries can lead to the risk of sustaining injuries!
Keep the batteries away from children.
In case of damaged batteries; avoid contact with skin, eyes and mucous
membranes.
When coming into contact with battery acid, clean the affected parts
immediately with plenty of clean water and, if necessary, contact a
doctor.
Caution! - Risk of damaging the device due to external factors!
Moisture and contamination can damage the device.
Protect the device against humidity, dirt and damage during transport,
storage and operation.
2.6 Use of batteries
To guarantee the correct function of the device, please observe the following points:
Do not use rechargeable batteries! The use of rechargeable batteries is not recommended
due to their lower voltage level in comparison to standard batteries.
Use only Type AA alkaline batteries.
Remove discharged batteries immediately from the device.
Do not use new batteries and used ones together.
If necessary, clean the batteries and contacts before inserting them.
2.7 Environment
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic
waste.
The device contains valuable raw materials which can be recycled.
Therefore, dispose of the device at the appropriate collecting depot.
All packaging materials and devices bear the markings and test seals for proper disposal.
Always dispose of the packaging material and electric devices and their components via the
authorized collecting depots and disposal companies.
The products meet the legal requirements, in particular the laws governing electronic and
electrical devices and the REACH ordinance.
(EU Directive 2012/19/EU WEEE and 2011/65/EU RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006).
Setup and function
Product manual 2CKA001473B9364
7
3 Setup and function
OFF
ECO
Radiator thermostat, Basic Radiator thermostat, Comfort
Fig. 1: Product overview of Radiator thermostats (Basic and Comfort)
The radiator thermostats HA-S-1-WL and HA-S-2-WL can be used to create a convenient single
room control of the temperature by operating the radiator heating (water-bearing radiators)
guided via wireless signal. No laying of cables required. Communication with the free@home
system is carried out wireless.
The radiator thermostats have an integrated temperature sensor, an integrated temperature
control, as well as an electric motor with drive unit to move the heating valve to a desired
position.
Other than the System Access Point, the devices require no further accessories for
commissioning.
The measured actual temperature value of the radiator thermostats is not displayed in the
visualization of the ABB-free@home
®
app.
The devices are not pre-programmed. Programming is carried out via the user interface of the
System Access Point.
Battery service life
The service life of the battery depends mainly on the respective usage. This means on how
often the motor of the actuating drive is moved, on the battery type and its state of charge.
Standard usage (in actuating drive status: 2 setpoint adjustments per day; in OFF mode from
May to September) the service life of the battery lasts generally up to 2 years.
Noise impairment
An electric motor operates inside the actuating drive. It influences the position of the valve
tappet via a drive unit. Fundamentally there is a low noise impairment when the motor moves to
a new valve position.
A new valve position is moved to when the user manually specifies a new setpoint value or a
time program. Also to regulate and to maintain a constant temperature an opening and closing
of the valve is necessary.
Movements of the motor are kept to a minimum to save power.
Setup and function
Product manual 2CKA001473B9364
8
3.1 Scope of supply
A
B
C
D
[A] Radiator thermostat, Comfort / Radiator thermostat, Basic
[B] 2 type AA alkaline batteries
[C] Screw for adapter
[D] Adapters for Danfoss valves (the pins labelled with the scissors symbol must be removed),
which have a thread size of M30 x 1.5 mm:
RAV (when using the RAV adapter, the RAV pin is required to extend the tappet).
RA
RAVL
3.2 Additional necessary components
The thermostat supports valves with a thread size of M30 x 1.5 mm; 3 Danfoss adapters are
additionally included in the scope of delivery (see chapter Scope of delivery). And the following
adapter types can additionally be ordered separately:
AC-HA-1 Herz adapter
AC-HA-2 Comap adapter
AC-HA-3 Orkli adapter
Setup and function
Product manual 2CKA001473B9364
9
3.3 Overview of types
Article no. Product name Colour
HA-S-1-WL Radiator thermostat, Basic White
HA-S-2-WL Radiator thermostat, Comfort White
Table 2: Overview of types
3.4 Functions
The following table provides an overview of the possible functions and applications of the
device:
Icon of the user interface Information
Name:
Radiator thermostat, Basic / Radiator
thermostat, Comfort
Type: Actuator
Made available by: Radiator thermostat Basic / Comfort
Function:
Regulates free@home radiator
thermostats (actuating drives)
Table 3: Overview of functions
Basic functions of Basic
The Basic version of the device has two push-buttons on top of the device:
OFF (off button): Switches the device into the OFF mode. This means that the temperature
is no longer regulated. The frost protection function and valve protection function are active.
Comfort: Switches the device into Comfort mode. The temperature is regulated to the
setpoint value. The setpoint value can be set via a connected extension unit (e.g. a
free@home-Touch 7“ or a free@home room temperature controller) or via the ABB-
free@home
®
app.
Basic functions of Comfort
The Comfort version has two push-buttons on top of the device, as well as a rotary knob at the
front of the device:
ON/OFF (off button): Switches the device into the OFF mode or Comfort mode. The
temperature is not regulated in the OFF mode. The frost protection function and valve
protection function are active. In Comfort mode the temperature is regulated to the setpoint
value. The setpoint value can be set locally via the rotary control element. The setpoint
value can also be set via a connected extension unit (e.g. a free@home-Touch 7“ or a
free@home room temperature controller) or via the ABB-free@home
®
app.
ECO: This is used to switch over between Comfort and ECO mode. In ECO mode the
temperature is reduced by a pre-programmed value. Example: You are leaving the room for
a few hours; the room temperature is to be reduced to save energy; however, the room is
not to cool down completely.
Setup and function
Product manual 2CKA001473B9364
10
Additional functions of both device versions
Extension unit mode: The radiator thermostat can be linked with other free@home
devices, so that these can then be used as "Extension unit" to remote control the heating
mode and the setpoint value of the radiator thermostat.
The temperature measurement and regulation continues to be carried out in this mode
locally in the radiator thermostat.
Devices that can be linked as extension unit with a radiator thermostat:
– free@home-Touch 7“
– free@home-Touch 4.3“
Room temperature controller
Wireless room temperature controller
– ABB-free@home
®
app
Low battery warning: The user is informed when the power of the battery drops below a
critical level. Although the radiator thermostat will continue to function for a few days after
the warning, replacement batteries should be kept ready. When the battery is completely
flat, the radiator thermostat remains in the position set last!
Valve protection function: To protect the valve, the radiator thermostat carries out a valve
protection movement every two weeks. The valve is moved to the fully open and closed
position once.
Valve adaptation: The adaptation movement is carried out during commissioning of the
radiator thermostat. This determines whether the valve can be actuated and the size of the
stroke for calibrating the radiator thermostat to this valve. A defective or non-existing valve
leads to an error message.
In case of a defective valve, please contact the installer of your heating system to replace
the valve.
Window open detection: The radiator thermostat can be linked with a window contact in
the free@home configuration interface. When the window is opened, the radiator thermostat
is switched off automatically or switched back on again when the window is closed.
Setup and function
Product manual 2CKA001473B9364
11
3.5 Device overview
Local operation
3
2
1
4
5
2
1
3
ECO
4
6
Radiator thermostat, Basic Radiator thermostat, Comfort
Fig. 2: Overview of devices Radiator thermostats (Basic and Comfort)
Basic Comfort
[1] LED [1] LED
[2] Comfort button: for setting the temperature to the
parameterized comfort setting.
[2] Display
[3] OFF button: for deactivating the device
Frost protection is active when the device is
switched off.
Switch the device on via the Comfort button [2]
[3] ECO button: for switching between comfort and
OFF mode.
[4] Temperature sensor (NTC)
[4] OFF button: for switching between the last
operating mode and OFF; the last mode can be
either Comfort or OFF mode.
[5] Handwheel
[6] Temperature sensor (NTC)
Technical data
Product manual 2CKA001473B9364
12
4 Technical data
Designation Value
Power supply 3 V (2x AA alkaline batteries)
Typical battery service life 2 years
Transmission frequency 2.400 - 2.483 GHz
Transmission protocol free@home wireless
Maximum transmission power WL (wireless) < 15 dBm
Protection IP20
Ambient temperature -5°C - +45°C
Storage temperature –20°C - +70°C
Protection IP20
Ambient temperature -5°C - +45°C
Storage temperature –20°C - +70°C
Connection M 30 x 1.5
Maximum valve lift 4.5 mm
Setting time 3 s/mm
Manner of operation Type 1
Pollution degree II
Test temperature
Ball indentation test
80°C housing, 100°C
Battery compartment, 125°C PCB
(EN 60730 21.2.5)
Software class A
Table 4: Technical data
Technical data
Product manual 2CKA001473B9364
13
4.1 Dimensional drawings
84
63
48
95
63
48
Radiator thermostat, Basic Radiator thermostat, Comfort
Fig. 3: Dimensions; all dimensions are in mm
Connection and installation
Product manual 2CKA001473B9364
14
5 Connection and installation
Note
Transmitter and receiver communicate via radio control. The transmission range
depends on the structural conditions. Walls and ceilings, especially steel
reinforcements or metal claddings, reduce the transmission range. The distance
of components to other transmitters that also emit high-frequency signals (e.g.
computers, audio and video systems) should be at least 1 m.
Radio range
To minimize the consumption of power, battery-operated free@home wireless devices are not
operated as repeaters. Different to free@home wireless devices with mains power, a received
command is therefore not transferred.
That is why during the installation it should ensured that there is at least one free@home
wireless device with mains power supply within the range of the battery-operated device.
Planning instructions
Planning and application instructions for the system are available in the ABB-free@home
®
system manual. This can be downloaded at www.abb.com/freeathome.
5.1 Installation
Mounting and installation are identical for both device versions. In the following, only the
Comfort version is shown as an example.
If the device is not in factory settings, the batteries must first be inserted, (See “Inserting the
batteries“ on page 16). The adjusting pin moves back and forth until the error condition "Er1" is
triggered. The thermostat can then be fitted.
Only install on common radiator valves located in dry, indoor rooms. Observe the currently valid
regulations.
Note
For the Basic version the error messages can only be viewed via the web-based
interface of the System Access Point.
Connection and installation
Product manual 2CKA001473B9364
15
Fitting the thermostat (factory settings)
1. Turn the old thermostat to fully open.
2. Loosen the fixture and pull the
thermostat head off the valve.
3*. If the union nut does not fit on the
valve, attach the adapter.
Completely remove the
connecting pieces (marked with
scissor symbol) of the plastic
adapters before using one of the
enclosed adapters!
If the valve has a thread size
different to M30 x 1.5 mm, please
use one of the listed adapters,
see chapter 3.2 “Additional
necessary components“ on page
8. However, these must be
ordered separately.
4. Fit the thermostat to the valve or the
adapter.
Connection and installation
Product manual 2CKA001473B9364
16
5. Turn the thermostat until it is tight.
Finally, remove the identification
label and glue it into the list (at
System Access Point).
Inserting the batteries
1. Press the lever underneath the
device towards the battery lid.
2. Lever out the battery lid.
3. Pull out the battery compartment.
4. Insert batteries into the battery
compartment.
Check that the polarity is correct!
5. Slide in the battery compartment
again until the lever engages.
The LED flashes briefly (battery
function test).
The device then carries out an
adjustment operation.
Only for the Comfort version:
"ADA" appears in the display.
The device is now ready for
commissioning.
Connection and installation
Product manual 2CKA001473B9364
17
5.2 Dismantling
Caution – damage to property
Damage to the device resulting from incorrect dismantling position
During dismantling, the device must be in the dismantling position. For this
purpose, the adjusting pin must be retracted.
1
2
1. To retract the adjusting pin, press
buttons [1] and [2] simultaneously for
15 seconds.
2. Loosen the thermostat by untwisting
the fixture of the thermostat.
3. Pull the thermostat off.
HA-S-1-WL HA-S-2-WL
1
2
Commissioning
Product manual 2CKA001473B9364
18
6 Commissioning
Commissioning of the device is always carried out via the Web-based surface of the System
Access Point. It is assumed that the basic commissioning steps of the overall system have
already been carried out. Knowledge about the Web-based commissioning software of the
System Access Point is assumed.
The System Access Point establishes the connection between the free@home participants and
the smartphone, tablet or PC. The System Access Point is used to identify and program the
participants during commissioning.
When energized, Basic and Comfort thermostats that have not been programmed are in
programming mode for 10 minutes and can be logged into the system. Programmed devices
share information about their type and supported functions with the System Access Point.
During initial commissioning all devices are given a universal name. The installer must change
this name within the commissioning process to a name practical and specific for the system.
The devices must be parameterised for the use of additional functions.
Note
General information about commissioning and parameterization is available in
the ABB-free@home
®
system manual.
6.1 Coupling of wireless devices with the System Access Point
6.1.1 Coupling devices
free@home wireless devices must first be coupled with the System Access Point before they
can be used in a project. The devices exchange a security key during the coupling process.
Communication between devices is carried out encrypted after coupling and they are firmly
connected with the System Access Point. Coupled devices cannot be connected with a different
System Access Point. They must first be reset to the factory settings.
Note
Separate commissioning is carried out for thermostats.
Carry out the following steps to couple one or several devices with the system:
1. Install the free@home wireless device(s).
2. Use your smartphone, tablet or PC to call up the user interface of the System Access Point
that is ready for use.
3. Remove the batteries from the device.
4. Start the scanning mode ("Settings" > "free@home-Wireless" > "Search for wireless
devices“).
Commissioning
Product manual 2CKA001473B9364
19
Fig 4: Coupling wireless devices with the System Access Point
5. Insert the batteries into the device.
The LED of the thermostat flashes briefly (battery function test).
The devices are now in programming mode for 10 minutes. The LED [1] flashes as long
as the programming mode is active.
1
1
EC O
Radiator thermostat, Basic Radiator thermostat, Comfort
The System Access Point consecutively scans all free@home wireless devices. Devices
that are in programming mode are integrated automatically into the system. The
scanning process ends 10 minutes after the last device has been found.
Integrated devices are listed in the "Device list" of the user interface.
6. Use the serial numbers to check whether all installed devices have been found.
If a device has not been found, reset it to the factory settings and start a new scanning
process.
Possible reasons for not finding devices:
The device is not in programming mode.
The 10-minute programming time has expired.
The device has already been coupled with a different system.
Commissioning
Product manual 2CKA001473B9364
20
6.1.2 Resetting the wireless device (thermostat) to the factory settings
1. Remove the batteries from the device and wait for 30 seconds.
2. Insert the batteries again and keep the button [1] pressed for at least 10 seconds, until the
LED stops flashing.
1
EC O
1
Radiator thermostat, Basic Radiator thermostat, Comfort
The factory settings are restored and the device can now be programmed again.
6.2 Allocation of devices and definition of channels
The devices connected to the system must be identified, i.e. they are allocated to a room
according to their function and are given a practical name.
The allocation is made via the "Devices" allocation function of the Web-based
user interface of the System Access Point.
The following figures show an example of the Basic version.
Always ensure that the correct filter is set, so that the correct device group is displayed.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38

ABB HA-S-2-WL User manual

Category
Thermostats
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI