700MM VICE/BENCH MOUNTING SHEET
METAL FOLDER
MODEL NO: TS01.V2
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
9 Wearapprovedsafetygoggles,gloves,andfootwear,whenoperatingthefolder.YourlocalSealeydealeroersacompleterangeof
safetyequipment.
9 Use the tool only for its intended purpose.
9 Regularlycheckallpartsofthefolderfordamagedparts.DO NOTuseifanyofitscomponentsarebroken,wornordamaged.
9 UseoriginalSealeysparepartsandaccessories.Useofnon-recommendedsparepartsmaybedangerousandwillinvalidate
warranty.
9 Ensure good footing, wear non slip footwear.
8 DO NOToperatethistoolwhileundertheinuenceofdrugs,alcoholorotherimpairingmedication.
8 DO NOTAllowunqualiedpersonstooperatethemetalfolder.Keepchildrenawayfromthetool.
2. INTRODUCTION
Benchandvicemountingsheetmetalfolder,ttedwithmountingplates.Capableofbendinga2mmsteelsheet,oflimitedlength,uptoand
beyonda90°angle.Theuniquepatentedendlessdesignandremovablefoldingplateallowstheusertofold,channelandosetanylengthof
sheetmetalupto1mmthick,bysimplymovingthesheetasrequiredaftereachfold.Withadjustablefoldplatetohelpachievethecleanest
foldpossible.Idealforthesmallgarageorrestorationoperation.
3. SPECIFICATION
MODEL NO: ............................................................ TS01.V2
Capacity: .................................. 20GaugeSheet,Ø1mmRod
4. OPERATION
4.1. Unpack the unit and check that all parts are included and not
damaged.Shouldyouexperienceaproblemcontactyour
supplierimmediately.
4.2. Positionfolderonbenchwhereitistobemounted,ensuring
thatthehandles(g.1.7)hangverticallyoverthefrontofthe
bench,usefootplates(g.1.6)astemplatestodrillholesin
bench,useappropriatexings.Orclampfolderinvice.
4.3. Byusingcentreadjustmentnut(g.1.4)ensuretopandbase
plateareparallel,thismayrequireadjustmentfromtimetotime.
4.4. Releaseclamps(g.1.1)ateitherendoffoldersothatasmall
testpieceofsheetmetalcanbeinsertedbetweenthetopandbaseplates.(g.1.3)
4.5. Positionthetestpiece,adjustthetopplatebyuseofclamps(g.1.1)lightlytighten,useaspannertoadjustcam(g1.2),sothat
baseandtopplatearealigned.
4.6. Ensurethatthereisevenpressureonbothends.
4.7. Raisethetopfoldingplate(g.1.3)byliftinghandlestocreatethefold.Fromthistest,youwillbeabletodeterminehowandwhere
the fold appears.
4.8. Whensatisedwiththetestresults,proceedwiththeactualworkpiece.
4.9. Byrotatingtheendclampsthroughtheverticalaxis,longerlengthsofmetalsheetcanbefolded,i.e.foldasection,unclamp,move
sheet,reclamp,foldsecondsectionetc.
1 Top/Baseplateclamp
2Adjustment/PositioningCam
3RemovableFoldingPlate
4 Centreadjustmentnut
5Top Plate
6 Footplatewithxingholes
7 Folding Handles
g.1
TS01.V2Issue109/05/2022
Original Language Version
©JackSealeyLimited
Refer to
instructions
Wear eye
protection
Wear protective
gloves
Wear safety
footwear
1
6
2
7