basIP UPS-DP-F User manual

Type
User manual
USER MANUAL
UPS-DP/F
UNINTERRUPTIBLE POWER SUPPLY UNIT
UPS-DP/F
It can also be used with individual panels or the concierge monitor.
Uninterruptible power supply unit for multi-apartment outdoor panels with
built-in control of electromagnetic and electromechanical lock.
Full User Manual
Appearance
Device description
wiki.bas-ip.com
Main features
Power supply: AC 100-230 V.
Output power: +12 V.
Maximum short-time load
current: 3.5 A.
Case: Metal.
Operating temperature: -40 – +60 °С.
Protection class: IP 30C.
Device connection type:
Multi-apartment door panel.
Dimensions: 180 × 190 × 72 mm.
UNINTERRUPTIBLE POWER SUPPLY UNIT
EAN: 5060514914700
Completness check of the product
Before installing the uninterruptible power supply unit, be sure to check that
it is complete and all components are available.
The power unit kit includes:
Uninterruptible power supply unit
Manual
1 pc
1 pc
After verifying the device's completeness, you can switch to the power unit
connection.
To connect power supply unit you will need:
Electrical connection
2
Сable RVV 2х1,5 mm .
You can connect the exit button,
electromechanical or electromagnetic
lock to this device.
Also there is a Fire input to trigger
relay in case of fire.
+-
Power
+12 V
Opening
lock time
adjustment
Exit
button
Less
More
N.C.
N.O.
GND
Contact
Fire alarm
input
Switching
contact type:
normally open
or normally closed
1. +12V
2. Ground
3. Lock
4. COM
5. N.C./N.O.
6. Unused
Output to connect
electromechanical lock
The connection scheme of all components
Power cable 1 pc
123
+12V GND Lock
LAN
Power
123
NC COM
Relay outputs to lock
4 5
NC NO
Wiegand output
123
+5V D0
4
GND D1
RS485
123
+12V 485+
4
GND 485-
Exit Button/Door Sensor
123
Exit Din
4
GND DS
RS232 (Option)
Green
RX
Black White
GND TX
COM
AA-07, AA-12, AA-14
BI-02, BI-04, BI-06, BI-08, BI-12
Outdoor panel
NC
NO
GND
Contact
Switching
contact type:
normally open
or normally
closed
Fire alarm
input
1. +12V
2. GND
3. Lock
4. Com
5. NC / NO
6. Reserve
Exit
button
Output from the
energy storage
device to the
electromechanical lock
Button+ Button- Lock+ Lock-
S
Lockable short-circuited
output
Exit
button
Electromagnetic
lock
Connection diagram of outdoor panels using an electromagnetic lock
connected from an uninterruptible power supply
Fire alarm
equipment
EAN: 5060514914700
NC
NO
GND
Contact
Switching
contact type:
normally open
or normally
closed
Fire alarm
input
1. +12V
2. GND
3. Lock
4. Com
5. NC / NO
6. Reserve
Exit
button
Output from the
energy storage
device to the
electromechanical lock
Button+ Button- Lock+ Lock-
AA-07, AA-12, AA-14
BI-02, BI-04, BI-06, BI-08, BI-12
Outdoor panel
123
+12V GND Lock
LAN
Power
123
NC COM
Relay outputs to lock
4 5
NC NO
Wiegand output
123
+5V D0
4
GND D1
RS485
123
+12V 485+
4
GND 485-
Exit Button/Door Sensor
123
Exit Din
4
GND DS
RS232 (Option)
Green
RX
Black White
GND TX
COM
S
Electromechanical
lock
Diagram of connection of outdoor panels using an electromechanical lock
connected from an uninterruptible power supply
Lockable short-circuited
output
Fire alarm
equipment
Exit
button
Mechanical mounting
It is also necessary to provide supply of a power cable, additional modules.
Before mounting the power unit, place on the wall with dimensions
of 180 × 190 × 72 mm must be provided.
Wall Power unit
Power Unit
180 mm 72 mm
190 mm
Warranty
The warranty card number
Model name
Serial number
Seller name
With following stated terms of warranty is familiar, functional test was
performed in my presence:
Customer signature
Warranty conditions
The warranty period of the product — 36 (thirty-six) months from
the date of sale.
Transportation of product must be in its original packaging or supplied one
by the seller.
The product is accepted in warranty repair only with a properly lled warranty
card and the presence of intact stickers or labels.
The product is accepted for examination in accordance with the cases
provided by law, only in the original packaging, in a full complete set,
appearance corresponding to the new equipment and presence of all relevant
properlylled documents.
This warranty is in addition to the constitutional and other consumer rights
and in no way restrict them.
Terms of warranty
The warranty card must indicate the name of the model, serial number,
purchase date, name of the seller, seller company stamp and
the customers signature.
Delivery to the warranty repair is carried out by the buyer himself.
Warranty repairs carried out only during the warranty period specied
in the warranty card.
The service center is committed to do everything possible to carry out
the repair warranty products, up to 24 working days. The period spent
on the restoration of product functionality is added to the warranty period.
EAN: 5060514914700
www.bas-ip.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

basIP UPS-DP-F User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI