Messages - Parameters

Krone Messages - Parameters Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the Krone Messages - Parameters Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Enclose this document with the operating instructions of the
machine.
Supplement to operating
instructions
Document number: 150001746_02_us
Version: 22/08/2023
Precision forage harvester
Software version: D2515020104300021
Error messages, information messages and parameters
Table of contents
2
Precision forage harvester
Supplement to operating instructions 150001746_02_en
1 Information on this document ..................................................................................................3
1.1 Validity .........................................................................................................................................3
1.2 Re-ordering ..................................................................................................................................3
1.3 Applicable documents..................................................................................................................3
2 Safety ..........................................................................................................................................4
2.1 Meaning of the supplement to the operating instructions ............................................................4
3 Error messages..........................................................................................................................5
3.1 Possible error types (FMI)............................................................................................................5
3.2 Error list........................................................................................................................................6
4 Information messages...........................................................................................................239
4.1 Information list..........................................................................................................................239
5 Parameter ...............................................................................................................................263
5.1 Parameter list...........................................................................................................................263
6 Index........................................................................................................................................312
Information on this document 1
Validity 1.1
Precision forage harvester
Supplement to operating instructions 150001746_02_en 3
1 Information on this document
1.1 Validity
This document is valid for:
BX404-60 (BiG X 1180) BX404-50 (BiG X 1080)
BX404-40 (BiG X 980) BX404-30 (BiG X 880)
BX404-27 (BiG X 780) BX404-25 (BiG X 780)
BX404-20 (BiG X 780) BX404-15 (BiG X 680)
BX404-12 (BiG X 680) BX404-10 (BiG X 680)
1.2 Re-ordering
You can request a replacement document if this document became completely or partly
unusable, or if you need it in a different language. Please specify the document number shown
on the cover page in your order. Alternatively, you can download the document online from
KRONE MEDIA https://media.krone.de.
1.3 Applicable documents
To ensure that the machine is used safely and as intended, observe the following further
applicable documents.
Operating instructions of the respective machine
2 Safety
2.1 Meaning of the supplement to the operating instructions
4
Precision forage harvester
Supplement to operating instructions 150001746_02_en
2 Safety
WARNING
Risk of injury due to non-observance of relevant safety instructions
If the relevant safety instructions are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the relevant safety instructions in the operating instructions
must be read and observed.
WARNING
Risk of injury due to non-observance of safety routines
If the relevant safety routines are not observed, persons may be seriously injured or killed.
In order to avoid accidents, the safety routines in the operating instructions must be read
and observed.
INFO
Depending on the machine type, the basic safety instructions can be found in the chapter
“Safety”, “Basic Safety Instructions” or in the chapter “Safety” of the machine operating
instructions.
2.1 Meaning of the supplement to the operating instructions
The supplement to the operating instructions is an important document and a part of the
machine. It is aimed at the user and contains safety-relevant information.
If the supplement to the operating instructions is not observed, people may be seriously injured
or killed.
Read in full and observe the “Safety” chapter of the corresponding operating instructions
before using the machine for the first time,see Page3.
Before working, also read and observe the respective sections of the corresponding
operating instructions,see Page3.
Keep the supplement to the operating instructions ready to hand for the user of the machine.
Hand over the supplement to the operating instructions to subsequent users.
Error messages 3
Possible error types (FMI) 3.1
Precision forage harvester
Supplement to operating instructions 150001746_02_en 5
3 Error messages
1
2
3
5
4
EQ003-072
1 Error number 3 Error description
2 Brief description of the error 4 Selection "Hide message until restart"
5 "Close" key
Structure of an error number
The error number is structured as follows, for example:
Error "TRM-521000-19"
TRM 521000 19
Control unit SPN (Suspect Parameter
Number) = error number
FMI = type of error, see
Page5
Acknowledging error message
Press to acknowledge the error message.
ÆThe error message is no longer displayed. The error message is displayed again if the fault
occurs again.
Or: click on "Hide message until restart"(4) and press .
ÆThe error message is no longer displayed. If the malfunction occurs again, the error
message is not displayed again. The error message is displayed again only after a restart.
Eliminate the error, see Page6.
Active errors and the error history can be displayed in the "Errors" menu on the terminal.
3.1 Possible error types (FMI)
There are different types of errors which are shown under the term FMI (Failure Mode
Identification) with an appropriate code.
FMI Meaning
0 The upper limit value was greatly exceeded.
1 The lower limit value was far below the required one.
2 The data is not permitted.
3 There is an overvoltage or a short circuit to supply voltage.
3 Error messages
3.2 Error list
6
Precision forage harvester
Supplement to operating instructions 150001746_02_en
FMI Meaning
4 There is an undervoltage or a short circuit to ground.
5 A cable is broken or amperage is too low.
6 There is a short circuit to ground or amperage is too low.
7 The mechanics do not respond or the expected result was not achieved.
8 The frequency is not permitted.
9 There is an abnormal update rate.
10 There is an abnormal rate of change.
11 The error cause is unknown.
12 There is an internal error.
13 The values of the calibration are outside the value range.
14 Particular instructions are required.
15 The upper limit value has been reached.
16 The upper limit value has been exceeded.
17 The lower limit value has been reached.
18 The lower limit value has not been reached.
19 There is a CAN communication failure.
20 The data deviates upwards.
21 The data deviates downwards.
31 The condition has been fulfilled.
3.2 Error list
Overview of the control units
Abbreviation Explanation
AFC Automatic spout control
AKP Multiple keypad
ASCB Automatic counterblade acceleration sensor
CAT-A4-ECU Caterpillar motor control module
CE Central electrical system
CIO CAN IO module
CL Control lever
DRC Drive control
FM Function module
GC Grinding operation
INS Content material sensor AgriNIR
KMB KRONE engine bridge
KMC KRONE Machine Controller
KP Keypad
LC Light control unit
Error messages 3
Error list 3.2
Precision forage harvester
Supplement to operating instructions 150001746_02_en 7
Abbreviation Explanation
LMB-ECU Motor control module
LUC Lifting unit control
MOS Contents and moisture measurement
MRDT Metal and rock detection
NM Navigation module
SCS Steering column switch
TRM Terminal
>>>
2AFC [}9]
2AKP [}11]
2ASCB [}13]
2CAT-A4-ECU [}15]
2CE [}27]
2CIO 1 [}32]
2CL [}34]
2DRC [}39]
2FM1 [}47]
2FM2 [}52]
2FM3 [}57]
2FM4 [}62]
2GC [}67]
2INS [}70]
2KMB1 [}73]
2KMB2 [}80]
2KMB3 [}87]
2KMB4 [}94]
2KMB5 [}101]
2KMC [}108]
2KP1 [}144]
2KP2 [}146]
2KP4 [}148]
2LC [}150]
2LMB-ECU2 [}153]
2LMB-ECU2-Slave [}200]
2LUC [}217]
2MOS [}224]
2MRDT [}226]
2NM [}229]
2SCS [}231]
3 Error messages
3.2 Error list
8
Precision forage harvester
Supplement to operating instructions 150001746_02_en
2TRM [}233]
Error list
Software version: D2515020149500008_200,
D2515020149500008_200
Control unit: AFC
Page 1
Error number Error text Description Figure
AFC-520192-19 CAN bus - Malfunction General CAN hardware fault
AFC-520203-3 Supply voltage - Overvoltage Input voltage too high > 32V.
AFC-520203-4 Supply voltage - Undervoltage Input voltage too low < 17.5V
AFC-520203-6 Supply voltage - Overload Power consumption of the control unit
is too high > 2A
AFC-520223-16 Temperature - Upper limit value
exceeded
Temperature of the control unit is over
80°C
AFC-520301-12 Control unit - Internal Error No access to the Power Management
Chip of the ECU
AFC-520303-3 Camera system - Overvoltage Camera sensor - input voltage too
high > 32V.
AFC-520303-4 Camera system - Undervoltage Camera sensor - input voltage too low
< 12V
AFC-520303-12 Camera system - Internal Error Calibration data not retrievable
AFC-520303-16 Camera system - Upper limit value
exceeded
Camera sensor - temperature
exceeded the temperature is above
85°C
AFC-520303-22 Camera system - Cable break or
short circuit to ground
No access to camera
AFC-520304-19 CAN communication - CAN
disturbance between control units
CAN communication problem with the
KMC
AFC-520500-11 Control unit - General disturbance ErrorRecovery - restart camera driver
AFC-520501-11 Control unit - General disturbance System was restarted by the
Watchdog
AFC-520502-11 Control unit - General disturbance Wrong version of CAN matrix
Error list
Software version: D2515020073500007_300
Control unit: AKP
Page 1
Error number Error text Description Figure
AKP-3904-7 "Open header locking/upwards" key -
Key pressed when system starts
Key depressed since machine started.
AKP-3905-7 "Preselect additional axle/minus" key
- Key pressed when system starts
Key depressed since machine started.
AKP-3906-7 "Preselection hitch coupling/open"
key - Key pressed when system
starts
Key depressed since machine started.
AKP-3907-7 "Preselect hopper/plus" key - Key
pressed when system starts
Key depressed since machine started.
AKP-3908-7 "Close" key - Key pressed when
system starts
Key depressed since machine started.
AKP-3909-7 "Left" key - Key pressed when
system starts
Key depressed since machine started.
AKP-3910-7 "Cabin lift/downwards" key - Key
pressed when system starts
Key depressed since machine started.
AKP-3911-7 "Adjust discharge distance/home"
key - Key pressed when system
starts
Key depressed since machine started.
AKP-3915-7 "Right" key - Key pressed when
system starts
Key depressed since machine started.
AKP-520192-19 Communication problem -
Malfunction
Communication problem
AKP-520198-12 Control unit - Internal Error EEPROM error
AKP-520203-3 Overvoltage - Overvoltage Supply voltage > 30 V
AKP-520203-4 Overvoltage - Undervoltage Supply voltage < 17.5 V
Error list
Software version: D2515020120400001_100
Control unit: ASCB
Page 1
Error number Error text Description Figure
ASCB-520192-19 Sensor B97 ASCB - Malfunction CAN4 H/L short circuit to ground/UB
ASCB-520198-12 Sensor B97 ASCB - Internal Error Error when reading from or writing to
the EEPROM
ASCB-520202-2 Sensor B97 ASCB - Logic error
electronics
EEPROM data when starting system
inconsistent
ASCB-520203-3 Sensor B97 ASCB - Overvoltage Overvoltage detected
ASCB-520203-4 Sensor B97 ASCB - Undervoltage Undervoltage detected
ASCB-520223-16 Sensor B97 ASCB - Upper limit value
exceeded
Overtemperature of CPU detected
ASCB-520300-2 Sensor B97 ASCB - Logic error
electronics
Sensor values invalid
Error list
Control unit: CAT-A4-ECU
Page 1
Error number Error text Description Figure
CAT-A4-ECU-29-2 Accelerator pedal position 2 -
Plausibility error
CAT-A4-ECU-29-3 Accelerator pedal position 2 - Short
circuit to UB
CAT-A4-ECU-29-4 Accelerator pedal position 2 - Short
circuit to ground
CAT-A4-ECU-29-8 Accelerator pedal position 2 - Signal
invalid
CAT-A4-ECU-91-2 Accelerator pedal position 1 -
Plausibility error
CAT-A4-ECU-91-3 Accelerator pedal position 1 - Short
circuit to UB
CAT-A4-ECU-91-4 Accelerator pedal position 1 - Short
circuit to ground
CAT-A4-ECU-91-8 Accelerator pedal position 1 - Signal
invalid
CAT-A4-
ECU-91-13
Accelerator pedal position 1 - Values
invalid, not plausible or outside the
calibration
CAT-A4-ECU-94-0 Fuel supply - Pressure - upper limit
value exceeded
CAT-A4-ECU-94-1 Fuel supply - Pressure - lower limit
value below minimum
CAT-A4-ECU-94-3 Fuel supply - Short circuit to UB
CAT-A4-ECU-94-4 Fuel supply - Cable break or short
circuit to ground
CAT-A4-
ECU-94-15
Fuel supply - Pressure - upper limit
value exceeded slightly
CAT-A4-
ECU-94-17
Fuel supply - Pressure - lower limit
value slightly below minimum
CAT-A4-
ECU-94-31
Fuel supply - Supply voltage outside
the permitted range
Page 2
Error number Error text Description Figure
CAT-A4-ECU-97-0 Sensor B36 Water in fuel - Soiling
CAT-A4-ECU-97-3 Sensor B36 Water in fuel - Short
circuit to UB or cable break
CAT-A4-ECU-97-4 Sensor B36 Water in fuel - Cable
break or short circuit to ground
CAT-A4-ECU-97-5 Sensor B36 Water in fuel - Cable
break
CAT-A4-
ECU-97-11
Sensor B36 Water in fuel -
Plausibility error
Value outside the permitted range
CAT-A4-
ECU-97-31
Sensor B36 Water in fuel - Supply
voltage outside the permitted range
CAT-A4-
ECU-100-3
Engine oil pressure - Short circuit to
UB
CAT-A4-
ECU-100-4
Engine oil pressure - Cable break or
short circuit to ground
CAT-A4-
ECU-100-10
Engine oil pressure - Signal invalid
CAT-A4-
ECU-100-13
Engine oil pressure - Values invalid,
not plausible or outside the
calibration
CAT-A4-
ECU-100-17
Engine oil pressure - Lower limit
value slightly below minimum
CAT-A4-
ECU-100-18
Engine oil pressure - Lower limit
value below minimum
CAT-A4-
ECU-101-3
Engine block pressure - Short circuit
to UB
CAT-A4-
ECU-101-4
Engine block pressure - Short circuit
to ground
CAT-A4-
ECU-101-13
Engine block pressure - Values
invalid, not plausible or outside the
calibration
CAT-A4-
ECU-102-3
Intake manifold - Short circuit to UB
or cable break
boost pressure sensor
Page 3
Error number Error text Description Figure
CAT-A4-
ECU-102-4
Intake manifold - Cable break or short
circuit to ground
boost pressure sensor
CAT-A4-
ECU-102-10
Intake manifold - Signal invalid Boost pressure sensor - abnormal rate
of change
CAT-A4-
ECU-105-3
Intake manifold - Short circuit to UB
or cable break
Air temperature
CAT-A4-
ECU-105-4
Intake manifold - Cable break or short
circuit to ground
Air temperature
CAT-A4-
ECU-108-3
Ambient pressure - Short circuit to
UB
CAT-A4-
ECU-108-4
Ambient pressure - Short circuit to
ground
CAT-A4-
ECU-108-13
Ambient pressure - Calibration fault
CAT-A4-
ECU-108-21
Ambient pressure - Outside the
permitted range
CAT-A4-
ECU-110-0
Coolant engine - Upper limit value
critically exceeded
Coolant temperature
CAT-A4-
ECU-110-3
Coolant engine - Short circuit to UB
CAT-A4-
ECU-110-4
Coolant engine - Short circuit to
ground
CAT-A4-
ECU-110-15
Coolant engine - Upper limit value
exceeded slightly
Coolant temperature
CAT-A4-
ECU-110-16
Coolant engine - Upper limit value
exceeded
Coolant temperature
CAT-A4-
ECU-111-1
coolant level - Lower limit value
critically below minimum
CAT-A4-
ECU-111-2
coolant level - Logic error electronics Loss of signals
CAT-A4-
ECU-111-17
coolant level - Lower limit value
slightly below minimum
Page 4
Error number Error text Description Figure
CAT-A4-
ECU-111-18
coolant level - Lower limit value below
minimum
CAT-A4-
ECU-158-2
Ignition lock battery potential Switch/
momentary switch S15 Ignition lock -
Plausibility error
CAT-A4-
ECU-168-0
Battery potential power input 1 -
Overvoltage
CAT-A4-
ECU-168-1
Battery potential power input 1 -
Undervoltage
CAT-A4-
ECU-168-2
Battery potential power input 1 -
Plausibility error
CAT-A4-
ECU-168-3
Battery potential power input 1 -
Overvoltage
CAT-A4-
ECU-168-4
Battery potential power input 1 -
Undervoltage
CAT-A4-
ECU-172-3
Suction air temperature - Short
circuit to UB
CAT-A4-
ECU-172-4
Suction air temperature - Short
circuit to ground
CAT-A4-
ECU-174-0
Fuel temperature 1 - Upper
temperature limit value critically
exceeded
CAT-A4-
ECU-174-3
Fuel temperature 1 - Short circuit to
UB
CAT-A4-
ECU-174-4
Fuel temperature 1 - Short circuit to
ground
CAT-A4-
ECU-174-15
Fuel temperature 1 - Upper
temperature limit value exceeded
CAT-A4-
ECU-174-16
Fuel temperature 1 - Over-/under-
temperature
CAT-A4-
ECU-190-8
Engine speed - Plausibility error
CAT-A4-
ECU-190-15
Engine speed - Upper limit value
exceeded slightly
Page 5
Error number Error text Description Figure
CAT-A4-
ECU-411-3
Exhaust gas recirculation difference
pressure - Short circuit to UB
CAT-A4-
ECU-411-4
Exhaust gas recirculation difference
pressure - Short circuit to ground
CAT-A4-
ECU-411-13
Exhaust gas recirculation difference
pressure - Calibration fault
CAT-A4-
ECU-412-3
Exhaust gas recirculation
temperature - Short circuit to UB
CAT-A4-
ECU-412-4
Exhaust gas recirculation
temperature - Short circuit to ground
CAT-A4-
ECU-441-0
Ambient Air Temperature Sensor B20
Ambient temperature - Upper limit
value critically exceeded
Auxiliary input
CAT-A4-
ECU-441-15
Ambient Air Temperature Sensor B20
Ambient temperature - Upper limit
value exceeded slightly
Auxiliary input
CAT-A4-
ECU-441-16
Ambient Air Temperature Sensor B20
Ambient temperature - Upper limit
value exceeded
Auxiliary input
CAT-A4-
ECU-544-8
Fan speed sensor - Signal invalid
CAT-A4-
ECU-620-3
Power supply 5-V sensor - Short
circuit to UB
CAT-A4-
ECU-620-4
Power supply 5-V sensor - Short
circuit to ground
CAT-A4-
ECU-626-5
Motor release device 1 - Cable break
CAT-A4-
ECU-626-6
Motor release device 1 - Short circuit
to ground or overload
CAT-A4-
ECU-630-2
Calibration storage - Logic error
electronics
CAT-A4-
ECU-631-2
Calibration module - Logic error
electronics
CAT-A4-
ECU-637-11
Engine setting sensor - General
disturbance
/