ESAB PSF 410 MW, PSF 315M/ME, PSF 315M/ME, PSF 500M/ME, PSF 410 MW, PSF 500M/ME User manual

  • Hello! I am an AI chatbot trained to assist you with the ESAB PSF 410 MW User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Valid from manufacturing week 2170457 342 001 031104
PSF 315M/ME
PSF 500M/ME
PSF 410 MW
Bruksanvisning
Brugsanvisning
Bruksanvisning
Käyttöohjeet
Instruction manual
Betriebsanweisung
Manuel d’instructions
Gebruiksaanwijzing
Instrucciones de uso
Istruzioni per l’uso
Manual de instruções
Ïäçãßåò ÷ñÞóåùò
Instrukcja obs³ugi
Návod k pou¾ívání
Kezelési utasítások
-- 2 --
Rätt till ändring av specifikationer utan avisering förbehålles.
Ret til ændring af specifikationer uden varsel forbeholdes.
Rett til å endre spesifikasjoner uten varsel forbeholdes.
Oikeudet muutoksiin pidätetään.
Rights reserved to alter specifications without notice.
Änderungen vorbehalten.
Sous réserve de modifications sans avis préalable.
Recht op wijzigingen zonder voorafgaande mededeling voorbehouden.
Reservado el derecho de cambiar las especificaciones sin previo aviso.
Ci riserviamo il diritto di variare le specifiche senza preavviso.
Reservamo--nos o direito de alterar as especificações sem aviso prévio.
Äéáôçñåßôáé ôï äéêáßùìá ôñïðïðïßçóçò ðñïäéáãñáöþí ×ùñßò ðñïåéäïðïßçóç.
Zastrzegamy sobie prawo do wprowadzenia zmian.
Výrobce si vyhrazuje právo na zmìnu úda bez edcházejiciho upozomìni.
Fenntartjuk az elözetes bejelentés nélküli változtatás jogát.
SVENSKA 3..............................................
DANSK 10................................................
NORSK 17................................................
SUOMI 24................................................
ENGLISH 31..............................................
DEUTSCH 38.............................................
FRANÇAIS 45.............................................
NEDERLANDS 52.........................................
ESPAÑOL 59..............................................
ITALIANO 67..............................................
PORTUGUÊS 74..........................................
ÅËËÇÍÉÊÁ 81.............................................
POLSKI 89.................................................
ÈESKY 96.................................................
MAGYAR 103................................................
ENGLISH
-- 3 1 --
TOCe
1 DIRECTIVE 32........................................................
2SAFETY 32...........................................................
3 INTRODUCTION 33...................................................
4 TECHNICAL DATA 34.................................................
5 CONSUMABLES 34...................................................
5.1 Changing electrode guide Replacing electrode conductors 34......................
5.2 Interchangeable connectors 35.................................................
5.3 Compressed air cleaning 35...................................................
5.4 Contact nozzles 36...........................................................
5.5 Electrode holder 36...........................................................
5.6 Gas nozzles 36..............................................................
5.7 Gas protection 36............................................................
6 OPERATION 37.......................................................
7 MAINTENANCE 37....................................................
8 SPARE PARTS AND ACCESSORIES 37.................................
DIMENSION DRAWING 110................................................
SPARE PARTS LIST 111...................................................
ACCESSORIES 118.......................................................
-- 3 2 --
bg11ea
1DIRECTIVE
DECLARATION OF CONFORMITY
ESAB Welding Equipment AB, S--695 81 Laxå, Sweden, gives its unreserved guarantee that welding
gun PSF 315M/ME, PSF 500M/ME, PSF 410MW from number 217 complies with standard EN
60974--7, in accordance with the requirements of directive (73/23/EEC).
-- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --------
Henry Selenius
Vice President
ESAB AB Arc Equipment
695 81 LAXÅ
SWEDEN Tel: + 46 584 81000 Fax: + 46 584 411924
Laxå 2002--04--25
2SAFETY
WARNING
READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE INSTALLING OR OPERATING.
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE PRECAU-
TIONS WHEN WELDING. ASK FOR YOUR EMPLOYER’S SAFETY PRACTICES WHICH SHOULD BE
BASED ON MANUFACTURERS’ HAZARD DATA.
ELECTRIC SHOCK -- Can kill
S Install and earth the welding unit in accordance with applicable standards.
S Do not touch live electrical parts or electrodes with bare skin, wet gloves or wet clothing.
S Insulate yourself from earth and the workpiece.
S Ensure your working stance is safe.
FUMES AND GASES -- Can be dangerous to health
S Keep your head out of the fumes.
S Use ventilation, extraction at the arc, or both, to take fumes and gases away from your breathing zone
and the general area.
ARC RAYS -- Can injure eyes and burn skin.
S Protect your eyes and body. Use the correct welding screen and filter lens and wear protective
clothing.
S Protect bystanders with suitable screens or curtains.
FIRE HAZARD
S Sparks (spatter) can cause fire. Make sure therefore that there are no inflammable materials nearby.
NOISE -- Excessive noise can damage hearing
S Protect your ears. Use earmuffs or other hearing protection.
S Warn bystanders of the risk.
MALFUNCTION -- Call for expert assistance in the event of malfunction.
PROTECT YOURSELF AND OTHERS!
GB
-- 3 3 --
bg11ea
Users of ESAB welding equipment have the ultimate responsibility for ensuring that anyone who
works on or near the equipment observes all the relevant safety precautions. Safety precautions
must meet the requirements that apply to this type of welding equipment. The following recommen-
dations should be observed in addition to the standard regulations that apply to the workplace.
All work must be carried out by trained personnel well--acquainted with the operation of the welding
equipment. Incorrect operation of the equipment may lead to hazardous situations which can result
in injury to the operator and damage to the equipment.
1. Anyone who uses the welding equipment must be familiar with:
S its operation
S location of emergency stops
S its function
S relevant safety precautions
S welding
2. The operator must ensure that:
S no unauthorised person is stationed within the working area of the equipment when it is
started up.
S no--one is unprotected when the arc is struck
3. The workplace must:
S be suitable for the purpose
S be free from draughts
4. Personal safety equipment
S Always wear recommended personal safety equipment, such as safety glasses, flame--proof
clothing, safety gloves.
S Do not wear loose--fitting items, such as scarves, bracelets, rings, etc., which could become
trapped or cause burns.
5. General precautions
S Make sure the return cable is connected securely.
S Work on high voltage equipment may only be carried out by a qualified electrician.
S Appropriate fire extinquishing equipment must be clearly marked and close at hand.
S Lubrication and maintenance must not be carried out on the equipment during operation.
3 INTRODUCTION
The PSF 315M, PSF 315ME, PSF 500M and PSF 500ME are a series of self--cooled
welding guns, while the PSF 410MW is water--cooled. The welding guns have been
developed for use in robot applications or mechanised welding. The welding guns’
structure and spare parts are evident from pictures and the spare parts list, see page
111.
This welding gun is available in a variety of types; for more information see the spare
parts register on page 111.
A range of accessories including welding tips, swan necks and contact nozzles are
also available.
Details of ESABs welding gun accessories can be found on page 118.
GB
-- 3 4 --
bg11ea
4 TECHNICAL DATA
Welding gun PSF 315 M
PSF 315 ME
PSF 500 M
PSF 500 ME
PSF 410 MW
Permittedloadat50%
intermittence
CO
2
MIX
500 A
450 A
Permittedloadat60%
intermittence
CO
2
MIX
MIX, with water--cooled gas nozzle
315 A
285 A
500 A
440 A
440 A
Permitted load at 100% intermittence
CO
2
MIX
MIX, with water--cooled gas nozzle
170 A
170 A
280 A
280 A
440 A
425 A
400 A
Electrode dimensions 0.6 -- 1,6 mm 0,6 -- 2.4 mm 0,6 -- 2,4 mm
Rec. gas flow l/min 10 -- 15 l/min 12 -- 18 1/min 11 -- 16 l/min
Weight, hose length
1.5 m
2m
3m
2.0 kg
2.3 kg
2.8 kg
2.9 kg
3.4 kg
4.3 kg
2.2 kg
--
3.2 kg
Intermittence factor
The intermittence factor specifies the time as a percentage of a ten--minute period during which you
can weld with a particular load.
5CONSUMABLES
5.1 Changing electrode guide Replacing electrode conductors
5.1.1 Install the correct nipple
ESAB Connection EURO Connection
Note! 2 nipples are supplied with each welding rod guide, 1 for an ESAB connection and 1
for a EURO connection.
GB
-- 3 5 --
bg11ea
5.1.2 Remove t h e gas cover and intermediate n o zzle.
5.1.3 Install the welding rod g u id e in the ho se assembly.
a) Turn the connecting piece clockwise when you encounter resistance
b) The welding rod guide goes in
5.1.4 Cut the welding rod guide to the correct length.
When cutting, the welding gun should be extended with the welding rod guide fully
inserted in the r ear connection. Cut the welding rod guide so that it protrudes by “X”
in accordance with the table below.
Welding gun
Length
Adapter Measure-
ment X
Helix Measure-
ment X
PSF 315M/ME
1.5 m 0368 145 001 27 mm 0368 683 001 22 mm
PSF 315M/ME 2.0 m 0368 145 001 28 mm 0368 683 001 23 mm
PSF 315M/ME 3.0 m 0368 145 001
31 mm 0368 683 001 26 mm
PSF 500M/ME 1.5 m 0368 146 001
24 mm 0368 684 001 26 mm
PSF 500M/ME 2.0 m 0368 146 001
25 mm 0368 684 001 27 mm
PSF 500M/ME 3.0 m 0368 146 001
28 mm 0368 684 001 30 mm
PSF 410MW 1.5 m 0458 984 001
20 mm 0458 683 001 22 mm
PSF 410MW 3.0 m 0458 984 001
29 mm 0458 683 001 31 mm
Sharp edges are not allowed on the inside of the welding rod guide after cutting.
5.1.5 Reinstall the intermediate nozzle and gas cover.
5.1.6 Install the welding gun on the machine.
5.2 Interchangeable connectors
Connectors are m anufactured with the same measurements between the mount and
the tip of the contact nozzle and are therefore directly interchangeable.
For dimensions and guaranteed tolerances, see diagram on page 110.
5.3 Compressed air cleaning
The connector has a connection and ducts for compressed air cleaning of the gas
nozzle.
GB
-- 3 6 --
bg11ea
5.4 Contact nozzles
Contact nozzles are selected according to electrode diameter, type of buffer gas and
the strength of the current being used. See table on page 118.
The contact nozzles are initially selected with the guidance of the CO
2
table. If
seizing occurs in the event of high welding data with Argon or mixed gas, select on
the basis of the MIX, AR table.
For HELIX, the table applies regardless of buffer gas type. HELIX contact nozzles
must be combined with a special nozzle, see spare parts list. Note that the item
number for HELIX includes 2 contact nozzles + 1 locking nut for installation.
5.5 Electrode holder
In order to achieve good welding rod feed, the welding rod guide should be selected
in accordance with the table on page 119. A Teflon--based welding r od guide
produces less friction and is kinder to the electrode, but normally has a shorter
service life than a steel spiral. It is suitable for all types of electrode, except for the
majority of core wire types thicker than 1.2 mm.
Steel spirals can be used for all except for stainless steel and aluminium electrodes.
For changing electrode guides see the enclosed instructions.
Note! All welding guns are supplied with electrode guides. Steel spiral for welding
rod 1.0.
5.6 Gas nozzles
If you want a gas nozzle with a smaller opening diameter, this is available as an
accessory for each gun. See the spare parts list. Note that it is also possible to
exchange the connector type.
IMPORTANT! There is a spray guard in the gas nozzle. This must be in place to
prevent welding spray penetrating the connector.
For good function, the gas nozzle must a lways be screwed in as far as it will go.
5.7 Gas protection
Several factors combine to provide good gas protection. The most important of these
are:
1. Choice of buffer gas. -- Mixed gas and argon require a greater flow than carbon
dioxide
2. Set flow quantity. -- See technical data (should be measured at the gas nozzle).
3. Set welding current. -- High current requires a greater gas flow.
4. Position of the welding joint. -- A vertical position requires a greater gas flow.
5. Type of welding joint. -- An outer corner joint requires a greater gas flow than a
butt joint. A fillet weld joint requires a cor respondingly smaller gas flow.
6. The angle of the welding gun against the workpiece. Below 45° entails a risk of
poor gas protection.
GB
-- 3 7 --
bg11ea
6OPERATION
General safety regulations for the handling of the equipment can be found on
page 32. Read through before you start using the equipment!
The welding gun contains a lead for starting point searching. This is connected to the
ring-- shaped adapter plug in the welding gun’s feeder end. The connection lead from
starting point searching (e.g. Smartac) is connected to the corresponding flat--pin
connection in the feeders terminal block (in MEC 44 Flat--pin pos. 18).
7 MAINTENANCE
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
Regular servicing reduces unnecessary and expensive operational stoppages.
1. Welding spray in the gas nozzle impairs the gas protection and increases the risk
of flash--over.
--Clean regularly and use a moderate amount of welding paste or welding spray.
2. The spray guard in the gas nozzle should be replaced when its front end has
become thin.
3. Every time the electrode bobbin is r eplaced, the welding hose should be
disconnected from the feeder and blown clean with compressed air.
4. The end of the electrode may not have any sharp edges when it is inserted into
the welding rod guide. This is particularly important in the case of Teflon--based
welding rod guides.
5. The water flow must be checked prior to use.
8 SPARE PARTS AND ACCESSORIES
PSF 315M/ME, PSF 500M/ME, PSF 410MW is designed and tested in accordance with
the international an European standards IEC/EN 60974--7 and EN 60974--7.
It is the obligation of the service unit which has carried out the service or repair work
to make sure that the product still conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication. When ordering, please state product type, serial number,
designation and spare part number in accordance with the spare parts list.
This fa cilitates dispat ch and ensures correct delivery.
GB
Måttskiss Målskitse Målskisse Mittap iirustus Dimension drawing Mass-
bild Cotes d’encombrement Maatschets Croquis acotado Dimensioni
Esboço com dimensões Ó÷åäéÜãñáììá ìåãåèþí Rysunek wymiarowany
Ó×ÅÄÉÁÑÁÌÌÁ ÌÅÃÅÈÙÍ
bg11dim
-- 1 1 0 --
ABCDEF
PSF 315M Std 3,5 20 22 94 196,3 63,4
PSF 315 M Extended 3,5 20 22 94 296,3 63,4
PSF 500 M Std 2,5 24 27 102 196,3 63,4
PSF 500 M Extended 2,5 24 27 102 296,3 63,4
PSF 410 MW Std. 25˚ 3,5 20 22 80 196,3 63,4
Gäller både Esab-- och Euroanslutning.
Gælder både Esab-- og Euro--tilslutning.
Koskee se Esab-- että Euroliitintä.
Gjelder både Esab-- og Eurotilkobling.
Applies to both Esab and Euro connection.
Gilt für Esab-- und Europaanschluß.
S’applique aux connexions Esab et Europe.
Zowel Esab-- als Euro-- aansluiting zijn van gelding.
Vale para las conexiones Esab y Euro.
Per connessione Esab e tipo Europa.
RelativoaEsabeaLigaçãoEuro.
Éó÷ýåé ãéá óýíäåóç Esab êáé ÅõñùðáúêÞ (EURO).
PSF 315 M/ME, 500 M/ME, 410 MW Edition 031104
Reservdelsförtecknin g Reservedelsfortegnelse Reservedelsliste
Varaosaluettelo Spare parts list Ersatzteilliste L iste d e pièces détachées
Reserveonderdelenlijst Lista de repuestos Elenco ricambi Lista d e peças
sobressalentes Ðßíáêáò áíôáëëáêôéêþí ìåñþí Seznam náhradních dílù
Spis czê¶ci zapasowych Tartalékalkatrészlista ÐÉíáÊÁ Ó áíôáë ëáêôéêÙí ì åñ Ùí SPiS CZʦCI ZAPASOWYCH
bg11s000
-- 1 1 1 --
Valid for serial no. 217--xxx--xxxx
Ordering numbers for PSF 315 M/ME, 500 M/ME, 410 MW
0367 233 894 Welding Gun PSF 315 ME 1.5 m, 25˚ EURO Connenction
0367 233 896 Welding Gun PSF 315 ME 1.5 m, straight EURO Connenction
0367 233 898 Welding Gun PSF 315 ME 3.0 m EURO Connenction
0367 233 900 Welding Gun PSF 315 ME 2.2 m EURO Connenction
0367 233 895 Welding Gun PSF 500 ME 1.5 m, 25˚ EURO Connenction
0367 233 897 Welding Gun PSF 500 ME 1.5 m, straight EURO Connenction
0367 233 899 Welding Gun PSF 500 ME 3.0 m, 25˚ EURO Connenction
0458 970 880 Welding Gun PSF 410MW 3.0 m, 25˚ EURO Connenction
0458 970 881 Welding Gun PSF 410MW 3.0 m, straight EURO Connenction
0458 970 882 Welding Gun PSF 410MW 1.5 m, 25˚ EURO Connenction
0458 970 883 Welding Gun PSF 410MW 1.5 m, straight EURO Connenction
0367 233 883 Welding Gun PSF 315 M 1.5 m, 25˚ ESAB Connenction
0367 233 884 Welding Gun PSF 315 M 2.0 m, 25˚ ESAB Connenction
0367 233 885 Welding Gun PSF 315 M 3.0 m, 25˚ ESAB Connenction
0367 233 892 Welding Gun PSF 315 M 2.0 m, straight ESAB Connenction
0367 233 893 Welding Gun PSF 315 M 3.0 m, straight ESAB Connenction
0367 233 889 Welding Gun PSF 500 M 1.5 m, 25˚ ESAB Connenction
0367 233 890 Welding Gun PSF 500 M 2.0 m, 25˚ ESAB Connenction
0367 233 891 Welding Gun PSF 500 M 3.0 m, 25˚ ESAB Connenction
Spare parts are to be ordered through the nearest ESAB agency as per the list on the back of the
cover. Kindly indicate type of unit, serial number, denominations and ordering numbers according to
the spare parts list.
Maintenance and repair work should be performed by an experienced person, and electrical work only
by a trained electrician. Use only recommended spare parts.
PSF 315 M/ME, 500 M/ME, 410 MW Edition 031104
Tillbehör Tilbehør Tilbehør Lisävarusteet Accessories Zubehör
Accessoires Accessoires Accesorios Accessori Acessórios Aîåóïõáñ
Spotøební díly Wyposa¿enie Kopó alkatrészek ÁÎÅÓÏÕÁÑ WYPOSA¯ENIE
bg11a1 1a
-- 1 1 8 --
NO TAG
Contact tip
The bore dimension of the contact tips is to be selected with regard to wire diameter , type of shielding
gas and actual intensity of the current -- we refer to the table below.
Standard M6 Standard M8
To start with, choose a contact nozzle as specified in the shortarc--table (CO
2
). Should binding occur
with high parameters when using Argon or gas mixture, choose contact nozzle from the sprayarc table.
Welding wire
Contact tip
Part Number Marked
Short arc Spray arc Short/Spray-
arc
M6
PSF 315M
PSF 315ME
M8
PSF 410MW,
PSF 500M/ME
0.6 (0.6) -- 0468 500 001 -- W0.6 ESAB
(0.8) 0.6 0.8 0468 500 002 0468 502 002 W0.8 ESAB
0.8 (0.8) 0.9 0468 500 003 0468 502 003 W0.8 ESAB
0.9 0.8 1.0 0468 500 004 0468 502 004 W0.9 ESAB
1.0 0.9 -- 0468 500 005 0468 502 005 W1.0 ESAB
1.1 (1.0) 1.2 0468 500 006 0468 502 006 W1.2 ESAB
1.2 1.0--1.1 -- 0468 500 007 0468 502 007 W1.2 ESAB
1.4 1.2 1,4 0468 500 008 0468 502 008 W1.4 ESAB
1.6 1.4 1,6 0468 500 009 0468 502 009 W1.6 ESAB
(1.6) 1.6 -- 0468 500 010 0468 502 010 W1.6 ESAB
2.0 2.0 -- -- 0468 502 011 W2.0 ESAB
2.4 2.4 -- -- 0468 502 012 W2.4 ESAB
Table 1
Helix M7 / M8
Helix M7 contact tip must be combined with special tip adapter. See spare parts list.
Welding wire
Contact tip
Ordering number Marked
Short arc
Spray arc Short/
Spray arc
M7
HELIX
M8
HELIX
0.6 0.6 -- 0368 313 880 -- 0.6 --
0.8 -- 0.8 0368 313 881 -- W0.8 --
0.9 0.8 0.9 0368 313 882 -- W0.9 --
1.0 0.9 1.0 0368 313 883 0368 313 983 W1.0 --
1.2 1.0 1.2 0368 313 884 0368 313 984 W1.2 --
1.4 1.2 1.4 0368 313 885 -- W1.4 --
1.6 1.4 1.6 0368 313 886 -- W1.6 --
Table 2
PSF 315 M/ME, 500 M/ME, 410 MW Edition 031104
bg11a1 1a
-- 1 1 9 --
Wire liner
NO TAG
Welding wire *) Teflon conduit incl. wear insert (steel) Wear insert separate
1.5 m 2m 3m Steel Teflon (Al)
0.6 mm 0366 550 898 0366 550 899 0366 550 880 0366 545 880 0368 742 880
0.8 mm 0366 550 900 0366 550 901 0366 550 882 0366 545 880 0368 742 880
0.9--1.0 mm 0366 550 902 0366 550 903 0366 550 884 0366 545 881 0368 742 880
1.2 mm 0366 550 904 0366 550 905 0366 550 886 0366 545 882 0368 742 881
1.4 mm 0366 550 906 0366 550 907 0366 550 888 0366 545 883 0368 742 881
1.6 mm 0366 550 908 0366 550 909 0366 550 890 0366 545 884 0368 742 881
2.0 mm 0366 550 910 0366 550 911 0366 550 892 0366 545 885 0368 742 882
2.4 mm 0366 550 912 0366 550 913 0366 550 894 0366 545 886 0368 742 882
*) The wire guide aperture = 1.5 x wire diameter. The wire guide is marked with the max. wire diameter (stamped on the nipple).
**) To be cut to gun length.
Table 3
Welding wire *) Steel spiral Teflon ceramic
liner
1.5 m 2m 3m 3 m **)
0.6--0.8 mm 0366 549 900 0366 549 901 0366 549 882 0457 969 880
0.9--1.0 mm 0366 549 902 0366 549 903 0366 549 884 0457 969 882
1.2 mm 0366 549 904 0366 549 905 0366 549 886 0457 969 882
1.4 mm 0366 549 906 0366 549 907 0366 549 888 0457 969 884
1.6 mm 0366 549 908 0366 549 909 0366 549 890 0457 969 884
2.0 mm 0366 549 910 0366 549 911 0366 549 892 0457 969 886
2.4 mm 0366 549 912 0366 549 913 0366 549 894 0457 969 886
*) The wire guide aperture = 1.5 x wire diameter. The wire guide is marked with the max. wire diameter (stamped on the nipple).
**) To be cut to gun length.
Table 4
Gasflow meter
To measure the current gas flow a gasflow meter is available as option, ordering number 0155716880.
ESAB AB
SE--695 81 LAXÅ
SWEDEN
Phone +46 584 81 000
www.esab.co m
031021
ESAB subsidiaries and representative offices
Europe
AUSTRIA
ESAB Ges.m.b.H
Vienna--Liesing
Tel: +43 1 888 25 11
Fax: +43 1 888 25 11 85
BELGIUM
S.A. ESAB N.V.
Brussels
Tel: +32 2 745 11 00
Fax: +32 2 726 80 05
THE CZECH REPUBLIC
ESAB V AMBERK s.r .o.
Prague
Tel: +420 2 819 40 885
Fax: +420 2 819 40 120
DENMARK
Aktieselskabet ESAB
Copenhagen--Valby
Tel:+4536300111
Fax:+4536304003
FINLAND
ESAB Oy
Helsinki
Tel: +358 9 547 761
Fax: +358 9 547 77 71
FRANCE
ESAB France S.A.
Cergy Pontoise
Tel:+33130755500
Fax:+33130755524
GERMANY
ESAB GmbH
Solingen
Tel: +49 212 298 0
Fax: +49 212 298 204
GREAT BRITAIN
ESAB Group (UK) Ltd
Waltham Cross
Tel: +44 1992 76 85 15
Fax: +44 1992 71 58 03
ESAB Automation Ltd
Andover
Tel: +44 1264 33 22 33
Fax: +44 1264 33 20 74
HUNGARY
ESAB Kft
Budapest
Tel:+3612044182
Fax:+3612044186
ITALY
ESAB Saldatura S.p.A.
Mesero (Mi)
Tel:+3902979681
Fax:+390297289181
THE NETHERLANDS
ESAB Nederland B.V.
Utrecht
Tel: +31 30 248 59 22
Fax: +31 30 248 52 60
NORWAY
AS ESAB
Larvik
Tel:+4733121000
Fax:+4733115203
POLAND
ESAB Sp.z.o.o
Warszaw
Tel: +48 22 813 99 63
Fax: +48 22 813 98 81
PORTUGAL
ESAB Lda
Lisbon
Tel: +351 1 837 1527
Fax: +351 1 859 1277
SLOVAKIA
ESAB Slovakia s.r.o.
Bratislava
Tel:+421744882426
Fax:+421744888741
SPAIN
ESAB Ibérica S.A.
Alcobendas (Madrid)
Tel: +34 91 623 11 00
Fax: +34 91 661 51 83
SWEDEN
ESAB Sverige AB
Gothenburg
Tel:+4631509500
Fax:+4631509222
ESAB International AB
Gothenburg
Tel:+4631509000
Fax:+4631509360
SWITZERLAND
ESAB AG
Dietikon
Tel: +41 1 741 25 25
Fax: +41 1 740 30 55
North and South America
ARGENTINA
CONARCO
Buenos Aires
Tel: +54 11 4 753 4039
Fax: +54 11 4 753 6313
BRAZIL
ESAB S.A.
Contagem--MG
Tel: +55 31 3369 4333
Fax: +55 31 3369 4440
CANADA
ESAB Group Canada Inc.
Missisauga, Ontario
Tel: +1 905 670 02 20
Fax: +1 905 670 48 79
MEXICO
ESAB Mexico S.A.
Monterrey
Tel: +52 8 350 5959
Fax: +52 8 350 7554
USA
ESAB Welding & Cutting Products
Florence, SC
Tel: +1 843 669 44 11
Fax: +1 843 664 44 58
Asia/Pacific
CHINA
Shanghai ESAB A/P
Shanghai
Tel: +86 21 6539 7124
Fax: +86 21 6543 6622
INDIA
ESAB India Ltd
Calcutta
Tel: +91 33 478 45 17
Fax: +91 33 468 18 80
INDONESIA
P.T. Esabindo Pratama
Jakarta
Tel: +62 21 460 01 88
Fax: +62 21 461 29 29
MALAYSIA
ESAB (Malaysia) Snd Bhd
Selangor
Tel: +60 3 703 36 15
Fax: +60 3 703 35 52
SINGAPORE
ESAB Singapore Pte Ltd
Singapore
Tel: +65 861 43 22
Fax: +65 861 31 95
ESAB Asia/Pacific Pte Ltd
Singapore
Tel: +65 861 74 42
Fax: +65 863 08 39
SOUTH KOREA
ESAB SeAH Corporation
Kyung--Nam
Tel: +82 551 289 81 11
Fax: +82 551 289 88 63
UNITED ARAB EMIRATES
ESAB Middle East
Dubai
Tel: +971 4 338 88 29
Fax: +971 4 338 87 29
Representative offices
BULGARIA
ESAB Representative Office
Sofia
Tel/Fax: +359 2 974 42 88
EGYPT
ESAB Egypt
Dokki--Cairo
Tel: +20 2 390 96 69
Fax: +20 2 393 32 13
ROMANIA
ESAB Representative Office
Bucharest
Tel/Fax: +40 1 322 36 74
RUSSIA--CIS
ESAB Representative Office
Moscow
Tel:+70959379820
Fax: +7 095 937 95 80
ESAB Representative Office
St Petersburg
Tel:+78123254362
Fax: +7 812 325 66 85
Distributors
For addresses and phone
numbers to our distributors in
other countries, please visit our
home page
www.esab.co m
/