Premier 120094 Installation guide

Category
Sanitary ware
Type
Installation guide
6. 7.
4.
2b.
INSTALLATION STEPS: Tub & Shower faucets
1.
5.
3.
2a.
Cleaning:
To maintain and protect the fine luster of all products .clean with a softdamp cloth
only .DO NOT USE detergents or cleanser as they may harm the protective finish.
Model Number: 120091 &120092 & 120093 &120094
Plumber's putty
Brand Tub & Shower Faucets Tools:
Groove joint pliers
Adjustable wrench Pipe wrench
screwdriver
Basin wrench
Pipe tape
INSTALLATION
8.
Place handle on valve stem and turn handle to
full on mixed position. Turn on hot and cold
water lines to full open for one minute each.
Check for leakage. Shut off water at faucet.
Remove the handle.
SUPPLY CONNECTION LAYOUT
Wrap plumber's tape around pipe threads in a
clockwise direction. Connect water supplies to left
(hot) and right (cold) valve body inlets. Connect
shower outlet pipe (2B) and tub outlet pipe (2C) to
valve body . Connect Pipe Elbow (2A) (not
included) to the end of the pipe.
SHUT OFF WATER SUPPLY.
Verify that the hole sizes and positions of
holes in the wall are correct.
Recommended component measurements.
A.Shower and / or spout outlet hole:
1-1/4" diameter.
B.Valve access hole: 6 inch diameter.
C. Recommended valve depth to finished
wall: 2" min. to 2-1/2"max.
Be sure that the black template plate's surface is flush
with the finished exterior surface of the wall. Be sure to
position the valve body correctly in wall. "UP" marking
up. The 8" Minimum from the valve body to the tub
spout is required for proper operation.
FOR SHOWER ARM INSTALLATION.
Insert the long end of the shower arm (3B)
through the flange (3A) then wrap plumber's
tape to both sides of shower arm. Screw long
end of the shower arm into pipe elbow inside
the wall.
FLUSHING
For Tub and Shower Combinations:
Turn on Hot and Cold water supply lines
allowing water to flow from tub spout outlet (4B)
until all foreign matter has cleared the line.
For Shower Only Combinations:
Turn on Hot and Cold water supply lines
allowing water to flow from shower outlet (4A)
until all foreign matter has cleared the line.
Pressure must be approximately equal on both
Hot and Cold sides for valve to function
properly.
FOR TUB SPOUT INSTALLATION
Install tub spout. Thread spout onto threaded
connection clockwise until the spout becomes
flush with the finished wall.
Thread sealant may be required depending on
your installation method. All thread sealants
may be found at your local hardware store.
Before installing escutcheon, remove the plastic
cap from plaster guard by twisting cap in a
clockwise direction. Remove the screw from the
inverter.
SHOWER ONLY SUPPLY CONNECTION LAYOUT
Wrap plumber's tape around pipe threads in a
clockwise direction.
Connect water supplies to left (hot) and right (cold)
valve body inlets.
Connect Shower Outlet Pipe (2B) to valve body. Plug
bottom outlet (2D) with plug (2E). Connect Pipe
Elbow (2A) (not included) to the end of the pipe.
Install escutcheon (8A) onto valve and then insert
screws (8B) to attach to valve body. Insert screw
(8C) into inverter. Place handle seat (8D) onto the
valve and secure with set screw (8E). Install handle
assembly (8F). Attach shower (8G) to shower
flange.
4B
4A
2E
2D
2A
2B
2C
2B
2A
rotational limit stop
stop on cartridge
colder
hotter
Tub&Shower
30"
8" Min.
Shower Only
48"
1 1/4" Dia
1 1/4" Dia
48"
6" Dia
30"
Shower Only
Tub&Shower
ADJUSTING WATER TEMPERATURE
Turn on water so that cold water is as cold as it will
get and hot water is as hot as it will get. Remove
the Rotational Limit Stop from the valve by sliding
it off the stem. Place handle back on stem and
rotate fully counterclockwise to the hottest position.
Place a thermometer in a plastic tumbler and hold
in the water stream. If the water temperature is
above 120° F, the Rotational Limit Stop must be
rotated counterclockwise to decrease temperature.
Reinstall the stop by sliding it back on to the stem
before reinstalling the handle.
MAKE SURE COLD WATER FLOWS FROM THE
VALVE FIRST.
MAKE SURE WATER (AT THE HOTTEST FLOW)
DOES NOT EXCEED THE TEMPERATURE LIMIT
ALLOWED BY YOUR PLUMBING CODES (120° F
OR 110° F).
7.
3A
3B
8A
8B
8C
8D
8E 8F
8G
Parts List
120091 &120092 & 120093 &120094
1
NO.
286
Shower Arm 287
Shower Head
1
247
Handle
9 1
994695
13
14
Cartridge
11
10
12 994722
285
Integral Stop
Shower Flange 1
1
1
1
1
994692 5 Handle Adapter Kit
6
8
7 994442
281
283
Screws
Escutcheon
Sleeve
2
3
4
259
20
O-ring
Set Screw 280
Handle Seat 1
1
1
1
1
1
1
PART NO.PART DESCRIPTION
MODEL NO.120093 QTY.
O-ring 282
15
Plug 284 1
1
2
3
456
7
89
10
11
12
13
14
15
16
16 Spout 288 1
994692 5
287
Shower Head 1
15
Handle Adapter Kit
Shower Arm
Shower Flange
Integral Stop
Escutcheon
Cartridge
Plug
10
11
12
14
13
Screws
O-ring
Sleeve
6
7
9
8
994695 1
1
1
1
1
286
285
284
994722
1
1
1
282
283
281
994442 1
1
PART DESCRIPTION
MODEL NO.120091
Set Screw
Handle Seat
2 O-ring
1
NO.
Handle
4
3 1
1
QTY.
1
1
280
259
247
PART NO.
20
1
Escutcheon 296 7
1
284
Plug
12
15 Shower Head
Spout
16
Shower Flange
14
13 Shower Arm 1
300 1
301
1
1
298
299
Integral Stop
10
11 Cartridge
O-ring
Sleeve
8
9 1
1
994722
994695
282 1
297 1
Handle Adapter Kit
Handle Seat
4
Screws
6
5
Set Screw
O-ring
3
2
1
295
1
1
994442
994692
1
1
20
259
MODEL NO.120094
PART DESCRIPTION
Handle
NO.
1 QTY.
1
PART NO.
255
994442 1
6 Screws
994722 1
11 Integral Stop
14 Shower Arm
15 Shower Head
Shower Flange
13 Plug
12
299 1
1
300
1
1
298
284
9 O-ring
10 Cartridge
8 Sleeve
Escutcheon
7
1
1
282
994695
1
1
297
296
1 1 Handle
Handle Adapter Kit
3 Set Screw
5
4 Handle Seat
2 O-ring 20 1
1
1
295
994692
1
259
255
MODEL NO.120092
PART DESCRIPTIONNO.QTY.PART NO.
  • Page 1 1
  • Page 2 2

Premier 120094 Installation guide

Category
Sanitary ware
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI