  • Hello! I am an AI chatbot trained to assist you with the Astria Fireplaces Mega Flame Mossy Oak LMF 24/30/36 MO Instruction Sheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Figure 1 - Measurement ''A''
Measurement “A”
Glass Door Frame
Measurement “A”
Fireplace Opening
1. Measure width of fi replace opening or glass door frame (see
Measurement "A", Figure 1).
Use work space below to fi gure proper size for fi replace hood.
Measurement "A"
Subtract 24 inches (width of hood center section)
Subtotal =
Divided by 2
Measurement "B" =
Measurement "B" is the distance from the outside edges of center-
hood section to outside edges of adjustable outer-hood sections
(see Figure 2). When adjustable outer sections are extended to
this measurement, hood will be correct size. The overall width
of the hood will equal the width of the fi replace opening. If you
have glass doors and would like the hood to hang beyond the
edge of the door frame, add 1/2 inch to measurement "B". Make
sure that hood provides room for opening doors.
2. If hood is brass, remove all protective fi lm from brass.
3. Place center-hood section face down on a smooth, soft surface.
4. Measure in from outside ends of adjustable outer-hood sec-
tions. Place a piece of tape on bent-under fl ange of adjustable
outer-hood sections to mark the distance of Measurement "B"
(see Figure 3).
BLACK FIREPLACE HOOD KIT
[FOR USE WITH MODELS: BLAZE&GLOW18/24, TRIFLAME18/24, MAGNIFLAME24/30. MULTI-SIDED27 NORTHERNOAK27, DUAL-FLAME EOS18, MONTEBELLO18/24,
SHERIDAN18/24, MNF24/30/36, GLOW-RAMP BGE18/2436, MULTI-SIDED FVFM27, VF18/24, DUAL-BURNER VD1824, SINGLE-BURNER LVS18/24, WHISPERINGOAK24,
BILTMORE18/24/30, RIVERCYN24, WHITEMTN24, SOMERSET27 FVFM27]
BLACK FIREPLACE HOOD KIT
P/N 127316-01
Rev. B, 03/2017
HEARTH PRODUCTS
KITS AND ACCESSORIES
Cat. No. Model Description
F1764 GA6050 Black Fireplace Hood Kit
KIT CONTENTS
1 ea. Fireplace Hood (consists of center-hood section and two adjustable
outer-hood sections)
4 ea. Sheet Metal Screws
4 ea. Masonry Screws
2 ea. Mounting Brackets
1 ea. Instruction Sheet, English
1 ea. Instruction Sheet, Spanish
REQUIRED TOOLS AND SUPPLIES
Phillips Screwdriver
GENERAL INFORMATION
These GA6050 hood kit is designed to be fi tted to the face of the
appliance at the top of the fi rebox opening. In addition to providing
an aesthetically pleasing appearance to your appliance installation,
the hood reduces heat effects to decorative mantels and fi nish
materials located directly above the fi replace and reduces the Mantel
/ Trim clearances (see the Installation and Operation Manual).
READ ALL THE STEPS BEFORE STARTING THE INSTALLATION
THE APPLIANCE MUST BE OFF AND COLD BEFORE BEGINNING.
ALL WARNINGS, PRECAUTIONS AND INSTRUCTIONS IN THE
INSTALLATION AND OPERATION MANUAL PROVIDED WITH THE
APPLIANCE APPLY TO THESE INSTRUCTIONS.
If you encounter any problems, need clarifi cation of these instructions
or are not qualifi ed to properly install this kit, contact you local
distributor or dealer.
If any of these parts are missing or damaged, contact your dealer or
IHP.us.com for referral information.
SIZING THE FIREPLACE HOOD TO THE FIREPLACE
OPENING OR GLASS DOOR FRAME
Remove the contents of the fi replace hood kit. Check for any missing
or damaged parts. If any parts are missing or damaged, promptly
inform the dealer where you purchased this kit.
The fi replace hood is adjustable from 28 to 48 inches. You must open
hood wide enough to cover the entire fi replace opening. You can
open hood wider if desired. For best appearance, make sure center
section of hood is centered with the fi replace opening.
Follow the following instructions to properly size the fi replace hood.
IHP.us.com 127316-01B
2
INSTALLING HOOD TO MASONRY FIREPLACE
Follow the instructions below that best describes your fi replace.
1. Loosen clamps that hold glass door frame to fi replace. Slide the
mounting brackets behind the glass door frame (see Figure 5).
Place brackets near ends of horizontal glass door frame. Note:
If frame is too tall, the bottom of mounting bracket will not slide
under lintel (top) of fi replace. If so, cut mounting bracket off at
point "B" (see Figure 6). Slide mounting bracket into glass door
frame (see Figure 7).
2. Tighten glass door lintel clamps. This will secure the mounting
brackets.
3. Slide the hood over the mounting brackets (see Figure 8).
5. Slide the adjustable outer-hood sections into the center section.
Stop when edge of center-hood section is even with tape (see
Figure 4).
6. Place pieces of tape across adjustable outer-hood sections and
center-hood section to hold in place.
IMPORTANT: You must remove tape before operating your fi replace.
Figure 4 - Adjust Outer-Hood Section
Figure 5 - Placement of Mounting Bracket
Figure 7- Mounting Bracket for Tall Frame
Figure 8- Hood Placement
Figure 6 - Mounting Bracket
Figure 3 - Mark for Measurement ''B''
Figure 2 - Measurement ''B''
Measurement '' B''
Adjustable Outer-
Hood Section
Tape
Measurement "B" Adjustable
Outer-Hood Sections
Center Hood
Section
Edge of Center-
Hood section
Mounting
Bracket
Glass
Door
Frame
B
ABottom of
Mounting
Bracket
Mounting
Bracket
Glass
Door
Frame
Mounting
Bracket
Hood
127316-01B 3
IHP.us.com
MASONRY WITHOUT GLASS DOORS
1. Tape the mounting brackets near the ends of the fi replace
opening. Make sure to position brackets as shown in Figure 9.
2. Mark screw locations on fi replace lintel through the slots on
bottom of each mounting bracket.
Figure 9 - Positioning Brackets for Masonry Fireplace
without Glass Doors
Mounting
Bracket
Masonry
Screw
Lintel
1. Remove mounting brackets and drill a 5/32 inch diameter hole
into fi replace lintel at each marked location.
2. Use the masonry screws provided to fasten brackets to lintel
(see Figure 9).
3. Slide hood over mounting brackets (see Figure 10).
Figure 10 - Hood Placement for Masonry Fireplace
Hood
Mounting
Brackets
WARNING
Many manufactured fi replaces have louver openings
for ventilation. Do not cover any louver openings with
replace hood. Do not mount fi replace hood above
any louver openings. Only mount fi replace hood
below louver openings. Covering louver openings
or mounting fi replace hood above louver openings
will cause the fi replace to overheat and could cause
property damage, personal injury, or death due to fi re.
You may need to alter or discard the mounting brackets to install
the fi replace hood to the manufactured fi replace.
INSTALLING HOOD ABOVE MANUFACTURED
FIREPLACE OPENING
1. Cut mounting bracket off at point "A" (see Figure 6, Page 2).
2. Tape mounting bracket to fi replace housing. Make sure top of
bracket is six inches above fi replace opening (see Figure 11).
3. Mark screw locations through slots in mounting bracket.
4. Remove mounting brackets and drill a 1/8 inch diameter hole
into fi replace housing at each marked location.
5. Use the sheet metal screws provided to fasten brackets to
replace housing (see Figure 11).
6. Slide hood over mounting brackets (see Figure 11).
INSTALLING HOOD TO MANUFACTURED FIREPLACE
Figure 11 - Installing Hood Above Opening on Manufactured
Fireplace
6"
Mounting
Brackets
Manufactured
Fireplace
Fireplace Opening
IHP.us.com
4
INSTALLING INTO MANUFACTURED FIREPLACE
OPENING
1. Discard the mounting brackets.
2. Place the hood inside the fi replace opening as shown in Figure 12.
3. Hold the hood in place and drill four holes through hood and
into channel on the fi replace opening (see Figure 13). Make sure
holes are evenly spaced and cover most of the hood's length.
4. Use the sheet metal screws provided to fasten the hood to the
replace opening.
Figure 12 - Installing Hood into Opening of Manufactured
Fireplace
Figure 13 - Screw Placement
Manufactured
Fireplace
Fireplace Opening
Fireplace
Opening
Approximate Screw
Locations
Fireplace
Cross
Section
Fireplace
Opening
Manufactured Fireplace
Manufactured
Fireplace
Fireplace
Hood
Printed in U.S.A. © 2014 Innovative Hearth Products
P/N 127316-01 Rev. B 03/2017
IHP reserves the right to make changes at any time, without notice, in design, materials, specifi ca-
tions, prices and also to discontinue colors, styles and products. Consult your local distributor
for fi replace code information.
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210
WARNING
Fireplace hood becomes very hot during fi replace
operation. Do not touch fi replace hood. Severe burns
could occur.
OPERATING FIREPLACE WITH FIREPLACE HOOD
IMPORTANT: Remove all tape used when installing fi replace hood
before operating fi replace.
/