  • Hello! I am an AI chatbot trained to assist you with the Aquatic Industries 1363-BFS LH Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
— 1 —
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
Items Included
Shower
Tools Needed
ADA/ANSI COMPLIANT BARRIER-FREE SHOWER STALLS
For roll-in showers with a flat threshold, build up or recess the bathroom floor 3/4” less the thickness of the finished floor. For beveled
thresholds, build up or recess the bathroom floor 3/4” less the thickness of the finished floor, ensuring that the finished floor meets the
base of the bevel at the threshold.
It is recommended that the bathroom floor outside ADA clear floor space be designed with a floor drain to alleviate any water over spray
that may escape the shower stall.
Product illustration may not
be representative of your unit.
3/16” Drill Bit
3-1/2” Drill Bit
1” Drill Bit
Phillips Screw Bit
#8 X 1”
Pan Head Screws
100% Mildew Resistant
Silicone Sealant
Square
Notched Trowel
(For use on non-level
floor applications only.)
Level
Hammer
Tape Measure
Drill
Aquatic products may be specified as Lasco Bathware.
— 2
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
NOTICE: Please inspect the unit thoroughly before installation to make sure it has not been damaged during transportation.
Under no circumstances should a damaged unit be installed. Neither Aquatic nor the distributor will be responsible for removal
or reinstallation costs should a replacement be necessary due to installation of a damaged unit.
PRE-INSTALLATION PLANNING
1. Unit must be placed within bathroom area before completion of door framing or, if preferred, studs may be omitted or knocked-
out to permit unit placement.
2. Review job print and Aquatic rough-in dimensions; verify all key dimensions against actual job conditions .
3. Make sure framed-in alcove is of proper size, square and plumb; check floor for levelness.
4. If alcove floor is not completely level, foundation materials [non-shrink grout] are mandatory under the bottom of each unit to
solidify for wheelchair support.
5. If fire-rated alcove is required, approved finish material must be in place prior to unit installation to meet fire safety requirements
of local building code and/or FHA/HUD Minimum Property Standards.
NOTE: Finished alcove must have interior dimensions
shown on rough-in diagram to permit installation of unit.
6. Provide 6” (150mm) floor opening for 2” (50mm) IPS and drain connection.
7. To avoid obstruction, make sure that supply lines and valve plumbing are not strapped to studs and do not project into
alcove. Also, drain pipe must not project above floor level prior to installation.
8. Make sure all plumbing is complete and to code.
9. To prevent scuffing while installing unit, cover the entire bottom of the unit with a piece of cardboard or other protective material.
10. Fasten drain fitting to unit before installing [see manufacturer’s instructions].
Fasteners for wood framing—1
1
2” galvanized roofing nails or #10 x 1
1
2” self-tapping washer head screws;
for concrete or block walls—1” concrete nails and nailing tool;
for steel studs (18 ga.)—drill flanges and studs with
5
32” carbide bit and use #12 x 1 sheet metal screws.
INSTALLATION PROCEDURE
For non-level alcove floor applications, prepare a foundation material mix
(industrial plaster, mortar mix) and spread throughout the alcove oor with a
square notched tile trowel. The foundation materials should spread around the
drain and extend to the perimeter of the shower oor.
6“Dia.
Rough In
Rough
Center
Overall Width
Overall
Depth
1
Foundation Material
Square
Notched Trowel
2
Note: If fire-rated alcove is required, approved finish materials must be
in place prior to unit installation to meet fire safety requirements of local
building codes and/or FHA/HUD Minimum Property Standards.
Check dimension of alcove; make sure walls are square and plumb and floor
is level. For completely level floor, proceed to Step 3.
— 3
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
3 4
5
Mark fitting locations. (Refer to measurements from step 3.) Using a hole saw
(fine tooth or abrasive grit cutting edge), make necessary openings for filler and
valves, drilling from inside (smooth side) out.
If mounting fittings — from stable reference points (back wall studs, floor)
measure the locations of spout and valves. Note measurements.
INSTALLATION PROCEDURE, CONT.
Check for level.
6
7 8
Fasten panel to framing at every stud and eight inches vertically through
nailing flange.
Cover the entire bottom of the unit with a piece of cardboard or other
protective material. Pre-drill pilot holes and fasten unit to floor starting in the
center of the base flange moving outward every 8 inches.
Place the unit directly on level floor (or on top of foundation materials) with
drain fitting over and onto waste pipe with threshold firmly on the floor.
A
ssure waste pipe protrudes well into drain fitting. Maintain proper floor
slope towards drain.
— 4
Aquatic • 8101 E. Kaiser Blvd. • Anaheim, CA 92808 • (800) 877-2005 • FAX (714) 998-5340 • www.aquaticbath.com
InstallationData
Accessible Showers with Pre-leveled Base
Fax on Demand # 2907
9. Make final connections to supply lines and waste pipe in accordance with plumbing code requirements. Strap water lines and
valve/s to studs.
CLEAN-UP
1. Do not remove warranty/maintenance adhered label.
Leave on unit for owner/occupant per code requirement.
2. Prevent staining. Remove all debris before plumbing leak test. Use sponge with warm water and liquid detergent. Rinse, drain and wipe
clean. Do not use abrasive cleansers such as scouring powders, steel wool, metal scrapers, sand paper or anything else that might mar,
dull or scratch the finish.
3. Plaster and latex paint may be removed with warm water, liquid detergent and brittle brush or plastic scraper. Glues, tars and enamels
may be removed with acetone or paint thinner. Do not use turpentine or laquer thinner. Do not use excessive heat or any caustic solvents
or chemicals.
4. Dull areas and light scratches may be removed by buffing with a light colored automotive rubbing compound and buffing pad. Entire unit can be
waxed with light colored automotive wax. Do not wax bottom of unit.
5. See user maintenance label for more details.
USER MAINTENANCE INSTRUCTIONS
IMPORTANT! Use only recommended cleaners and procedures described herein. Use of other materials and methods may damage
your bath fixture and void the warranty.
1. For normal cleaning: Never use abrasive cleaners such as scouring powders or pads, steel wool, scrapers, sandpaper or anything else that
could scratch or dull the surface of your Aquatic unit. Instead, use warm water and liquid detergents or non-abrasive cleansers, especially
those bathroom cleaners recommended for cleaning fiberglass.
2. To keep your Aquatic bath fixture sparkling clean: Apply a coat of good quality automotive paste wax or polish and buff to a high shine
with a soft cloth or towel. Repeat every six months for easier cleaning and long lasting protection.
NOTE: DO NOT WAX textured, slip-resistant standing surface of the unit bottom. This could result in greater risk of slipping and personal injury.
3. To restore a scratched or dull unit: Use an automotive polishing compound applied with a clean cotton rag. Rub scratches and dull areas
vigorously. Wipe off residues. Follow with automotive wax treatment described above.
4. To remove adhesive: Try 3-M Natural Cleaner, De-Solv-It or similar materials. If residues remain, saturate a small, white, cotton rag with
nail polish remover (naphtha or acetone) and rub vigorously until the adhesive dissolves and disappears. These solvents are highly
flammable and must be used sparingly and with caution. Do not smoke or permit others to do so. Make sure all nearby heating devices
(including pilot lights) are extinguished. Do not allow solvent to go down the drain. Make sure not to contact plastic drain grates or other
synthetic materials.
5. Rubber Mats: If you use a rubber “anti-skid” mat, make sure to remove it from the unit after each use to avoid harm to the surface finish.
6. Hard Water: Water in certain regions, if not wiped up after bathing/showering, may cause fading of some bath fixture colors. This is a
natural occurrence beyond Aquatic ’s control. (See Warranty)
CAUTION: When using any cleaning or polishing materials, make sure to read and follow all package instructions carefully. Wear
rubber gloves at all times and avoid contact with eyes, skin, clothing, rugs and furnishings. Make sure all residues are rinsed off thoroughly.
1521 No. Cooper, Ste. 500
Arlington, TX 76011
PH: 800-945-2726, 817-801-8300
FAX: 866-544-5353
Customer Service | Technical Services | Warranty Services
LITID2907
/