HP 11i User manual

Type
User manual
ACC X.25 Data Analyzer Users Guide
Edition 1
HP 9000 Networking
Manufacturing Part Number : Z7345-90004
E0204
© Copyright 2004 Hewlett-Packard Company.
2
3
Legal Notices
The information in this document is subject to change without notice.
Hewlett-Packard makes no warranty of any kind with regard to this
manual, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Hewlett-Packard
shall not be held liable for errors contained herein or direct, indirect,
special, incidental or consequential damages in connection with the
furnishing, performance, or use of this material.
Warranty. A copy of the specific warranty terms applicable to your
Hewlett- Packard product and replacement parts can be obtained from
your local Sales and Service Office.
Restricted Rights Legend. Use, duplication or disclosure by the U.S.
Government is subject to restrictions as set forth in subparagraph (c) (1)
(ii) of the Rights in Technical Data and Computer Software clause at
DFARS 252.227-7013 for DOD agencies, and subparagraphs (c) (1) and
(c) (2) of the Commercial Computer Software Restricted Rights clause at
FAR 52.227-19 for other agencies.
HEWLETT-PACKARD COMPANY 3000 Hanover Street Palo Alto,
California 94304 U.S.A.
Use of this manual and flexible disk(s) or tape cartridge(s) supplied for
this pack is restricted to this product only. Additional copies of the
programs may be made for security and back-up purposes only. Resale of
the programs in their present form or with alterations, is expressly
prohibited.
Copyright Notices. ©copyright 1983-2000 Hewlett-Packard Company,
all rights reserved.
Reproduction, adaptation, or translation of this document without prior
written permission is prohibited, except as allowed under the copyright
laws.
©copyright 1979, 1980, 1983, 1985-93 Regents of the University of
California
4
This software is based in part on the Fourth Berkeley Software
Distribution under license from the Regents of the University of
California.
©copyright 1980, 1984, 1986 Novell, Inc.
©copyright 1986-1992 Sun Microsystems, Inc.
©copyright 1985-86, 1988 Massachusetts Institute of Technology.
©copyright 1989-93 The Open Software Foundation, Inc.
©copyright 1986 Digital Equipment Corporation.
©copyright 1990 Motorola, Inc.
©copyright 1990, 1991, 1992 Cornell University
©copyright 1989-1991 The University of Maryland
©copyright 1988 Carnegie Mellon University
©copyright 1989-1997 Data Connection Limited
Trademark Notices UNIX is a registered trademark in the United
States and other countries, licensed exclusively through X/Open
Company Limited.
X Window System is a trademark of the Massachusetts Institute of
Technology.
MS-DOS and Microsoft are U.S. registered trademarks of Microsoft
Corporation.
OSF/Motif is a trademark of the Open Software Foundation, Inc. in the
U.S. and other countries.
5
Publishing History
The manual publishing date and part number indicate its current
edition. The publishing date will change when a new edition is
published. Minor changes may be made without changing the publishing
date. The manual part number will change when extensive changes are
made.
Manual updates may be issued between editions to correct errors or
document product changes. To ensure that you receive the updated or
new editions, you should subscribe to the appropriate product support
service. See your HP sales representative for details.
First Edition February 2004 Release 1.0
6
7
Preface
This manual describes the Data Analyzer accessory product for the ACC
family of multiplexers.
Manual Organization
This manual contains the following chapters and appendices:
Chapter 1 Chapter 1, “Overview,” provides an overview of the
data analyzer, a description of data analyzer features,
and data analyzer requirements.
Chapter 2 Chapter 2,Installing the Data Analyzer,” describes
how to install analyzer Y-cables, install the analyzer
software, and configure the analyzer.
Chapter 3 Chapter 3, “Data Analyzer Commands, describes each
of the data analyzer program commands. Each
command is described in detail and followed by
example of use of the command.
Appendix A Appendix A, “Network Configuration,” provides
detailed information on setting up the network
configuration file.
Appendix B Appendix B, “Typical X.25 and Data Analyzer
Sessions,” provides the results of actual data analyzer
sessions that were run using this software.
8
Related Documentation
The documentation available for the Multiprotocol ACC family of
products includes the following hardware and software manuals:
Hardware Manuals
8 Channel PCI ACC Multiplexer Hardware Installation and
Reference Manual
Software Manuals
ACC Installation and Configuration Guide
ACC Utilities Reference Guide
ACC Programmer’s Reference Guide
ACC Error Guide
HDLC Frame Protocol Users Guide
ACC X.25 Protocol User’s Guide
ACC X.25 Data Analyzer User’s Guide
ACC HDLC/LAP-B (ABM) Protocol User’s Guide
HDLC-NRM (SDLC) Protocol User’s Guide
X.25/ACC Installation and Configuration Guide
X.25/ACC Update Guide
X.25/9000 User’s Guide
X.25/9000 Programmer’s Guide
9
Contents
1. Overview
Data Analyzer Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Data Analyzer Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Data Analyzer Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
2. Installing the Data Analyzer
Installing the Analyzer Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Software Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Verifying Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Configuring the Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Dynamic Set-Up of Analyzer Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3. Data Analyzer Commands
Detailed Command Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
exit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Examples. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Example. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
run. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Contents
10
Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
runc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
show . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
stopd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
A. Network Configuration
Setting Up the Network Configuration File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Mux Firmware Download File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Port Definitions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
ZLU Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Running TTGEN and Starting the ACC Mux. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Starting ACC Subsystem and Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Running PDISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Sample Network Configuration File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
B. Typical X.25 and Data Analyzer Sessions
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
General Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Chapter 1 11
1 Overview
This chapter provides an overview of the data analyzer, a description of
data analyzer features, and data analyzer requirements.
Overview
Data Analyzer Overview
Chapter 112
Data Analyzer Overview
The data analyzer is supplied with the ACC Base System product. It is a
software based tool that allows real-time capture and analysis of X.25
traffic on one or more X.25 links simultaneously. It runs within an
HP-UX based HP 9000 system. Although the data analyzer is designed to
monitor X.25 or ISDN traffic from the ACC products, it can be attached
to any RS-232 or V.35 X.25 connections with line speeds up to 1222 Kb/s.
Each X.25 connection to be monitored on an 8-Channel card requires two
ACC multiplexer ports, thus a single 8-channel ACC multiplexer card
can support up to four analyzer sessions. Two ports are required on the
8-channel PCI card only if a non-ACC X.25 link is being monitored. The
analyzer can provide up to 8 concurrent sessions by using the ports on
two or more 8-Channel ACC cards. For ISDN traffic analysis, each
connection requires only one sub-channel.
The Data Analyzer is composed of three major components:
HDLC frame receiver multiplexer firmware
HP-UX capture/filter daemon
Display and analysis program
Figure 1-1 on page 13 shows the relationships between these
components, as well as the unique 'software-only' input configuration
with respect to the 8-Channel PCI ACC products. Configuration
information is set up either in the ACC TTGEN configuration file, or
dynamically by means of the convenient runc command.
Overview
Data Analyzer Overview
Chapter 1 13
Figure 1-1 Overview of ACC based Data Analyzer
Capture / Filter
Daemon
Data capture
File(s)
Commands to
Filter
Configuration
information
pcapture
Uses software
access only
runc
8 port PCI &
mux card(s)
Display / Control
Program
Analyzer Application Software
Overview
Data Analyzer Overview
Chapter 114
Only one copy of the capture daemon runs in each HP 9000 system. It
handles all analyzer sessions. The control of these sessions comes from
one or more invocations of the Display program. The pdisplay program
is designed to work on any HP-UX TTY device. Several copies of the
pdisplay program can independently control several analyzer sessions
simultaneously, or one pdisplay program may control multiple sessions.
The pcapture program can monitor all traffic on a particular X.25 link,
or it can selectively monitor only traffic belonging to certain Virtual
Circuits (VCs) on a link. The VCs of interest are identified by their
Logical Channel Number (LCN); up to six filter LCNs may be specified
for each X.25 analyzer session. By using this filter option, the size of the
capture file can be minimized.
The pdisplay program also provides a filtering mechanism to select
events from the capture file by LCN. Both these filtering mechanisms are
independent. The pdisplay program also provides many options for
displaying the captured X.25 or ISDN traffic (see “display” on page 27 for
a detailed description of the display command).
Overview
Data Analyzer Features
Chapter 1 15
Data Analyzer Features
The following list summarizes the features offered by the ACC X.25 data
analyzer.
Simultaneous monitoring of up to 8 X.25 lines - up to 32 may be
configured
Line speeds of up to 2Mb/s supported on 8-channel PCI mux cards
V.35 and RS 232 support
Capture file size up to 2Gb (depends on the size of HP-UX disk
subsystem)
Pre-processing filtering by LCN available (up to 6 LCNs)
Real-time display of X.25 or ISDN events
Post-processing filtering by LCN number (up to 6 LCNs)
Review of capture files by event number or range
X.25 L2 LAP-B header decoding
X.25 Packet header decoding
X.25 facilities decoding
Raw data display in Hex, ASCII, and EBCDIC
Event number and time-stamp display
See Chapter 3, “Data Analyzer Commands,” on page 25 for detailed
descriptions of how to use the data analyzer commands.
Overview
Data Analyzer Requirements
Chapter 116
Data Analyzer Requirements
The data analyzer requires that the ACC Base System product has been
installed, including at least one ACC Interface card and (if the hardware
is 8-Channel) a selected multiplexer panel.
Chapter 2 17
2 Installing the Data Analyzer
Installing the Data Analyzer
Installing the Analyzer Software
Chapter 218
Installing the Analyzer Software
The data analyzer software is provided with the ACC Base Product,
which comes in SD-UX format.
Installation requires the following general steps:
1. Remove any previous version of the data analyzer software with
swremove.
2. Use swinstall to install the ACC base product (or just the data
analyzer software if ACC base software is already installed).
3. Check /var/adm/sw/swagent.log for any errors during install.
4. Configure the analyzer.
Software Removal
If a previous version of the ACC X.25 Protocol Analyzer product is
already on the target system, remove it before the new software is
installed.
CAUTION It is very important to follow the instructions, provided with the ACC
software that is currently installed in the system, to shut down and
remove that software. This procedure may change between major
releases of the ACC product.
Step 1. Log in to the system as superuser.
Step 2. Terminate the ACC Mux Subsystem by typing:
% zmasterd kill
Step 3. Run swremove to remove the ACC X.25 Protocol Analyzer product.
% swremove
Installing the Data Analyzer
Installing the Analyzer Software
Chapter 2 19
NOTE swremove will fail if any ACC daemon is still active. Terminate any
active ACC daemon indicated in the log file and try again.
Any or all of the ACC related products besides Data Analyzer can be
removed by selecting them and then marking them for removal. (Both
the terminal interface and the GUI interface for swremove behave the
same; only the means for selecting items differs.)
Step 4. Select the items to be removed in the “Software Selection Window” and
mark for removal, using the “Mark for Remove” function under the
“Actions” menu.
When all items are marked, select the “Remove(analysis)” action.
Open “Logfile” to view running status of the removal process, and follow
any screen prompts until the removal process is done.
Software Installation
The ACC Data Analyzer software is read from the HP-UX Application
CD-ROM, in superuser mode, using the swinstall utility. The steps are
shown below.
Step 1. Log in to the system as “root.”
Step 2. Place the media in a local or remote CD-ROM drive.
Step 3. Run swinstall, which behaves the same in the GUI interface as for the
terminal interface. When the “Specify Source” box opens, select “Source
Depot Type” to “Local CDROM,” or for a remote CD-ROM driver, select
for “Network Directory/CDROM” and set “Source Host Name...”. Select
“OK.”
Step 4. Select the ACC Base Product (or the bundle that contains this). If the
ACC Base Product is already installed, you may just select the Analyzer
fileset from the ACC Base Product (hit the [Return] key to step into the
product). Open the “Actions” menu and select “Mark for Install.”
Step 5. When this item has been marked, select “Install (analysis);” select “OK”
and proceed.
Installing the Data Analyzer
Installing the Analyzer Software
Chapter 220
The “Install (analysis)” window allows you to track summary progress of
the installation process. Use the “Logfile” feature to display a detailed
status, which is logged to /var/adm/sw/swagent.log.
Verifying Installation
Check the end of the swinstall log file /var/adm/sw/swagent.log to
ensure that there were no errors during the installation. If errors
occurred, correct the problem and repeat the swremove and swinstall
steps.
The Data Analyzer software contains a sample capture file. This file is
installed into the directory /var/opt/acc/log and is called sample.eve.
This file can be viewed using the pdisplay program. To try this, run
pdisplay from the shell prompt.
If neither the ZCOM subsystem nor the pcapture program are currently
up and running, the following message will be displayed:
$ pdisplay
Bad zinit call, error:ZCOM system is not started up
Bad zopen call, error:Must call ZINIT first
Bad zopen call, error:Must call ZINIT first
Bad zname call, error:Must call ZINIT first
***** Warning *****
Cannot find primary ZLU of pcapture - pcapture probably not running
Some functions of this program will not be available
***** Warning *****
Cannot get storage offset for label ANLYZR,Error:Must call ZINIT first
Display>
If the ZCOM subsystem is up and running but the pcapture daemon is
not running, the following message will be displayed:
$ pdisplay
***** Warning *****
Cannot find primary ZLU of pcapture - pcapture probably not running
Some functions of this program will not be available
***** Warning *****
Display>
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

HP 11i User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI