On-Q 364891-01 Owner's manual

Category
Networking
Type
Owner's manual
Page ii
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
WIRELESS ACCESS POINT
P/N 364887-01(In-Ceiling)
P/N 364891-01(In-Wall)
OWNER’S MANUAL
1307877 REV.B
Page ii
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
Federal Communications Commission Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of
the Federal Communications Commission (FCC) rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Reprinted from the Code of Federal Regulations #47, part 15.193, 1993. Washington DC: Office of the Federal
Register, National Archives and Records Administration, U.S. Government Printing Office.
Canadian Department of Communications
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus set out in
the Radio Interference Regulations of the Canadian Department of Communications.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est
conforme à la norme NMB-003 du Canada.
FCC Radio Frequency Exposure Caution Statement
In order to maintain compliance with the FCC RF exposure guidelines, this equipment should be installed and
operated with minimum distance 20cm between the radiator and your body. Use only with supplied antenna.
Unauthorized antenna, modification, or attachments could damage the transmitter and may violate FCC regulations.
Any changes of modifications not expressly approved by the grantee of this device could void the users authority to
operate the equipment.
Installation and use of this Wireless LAN device must be in strict accordance with the instructions included in the user
documentation provided with the product. Any changes or modifications (including the antennas) made to this device
that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. The
manufacturer is not responsible for any radio or television interference caused by unauthorized modification of this
device, or the substitution or attachment of connecting cables and equipment other than manufacturer specified. It is
the responsibility of the user to correct any interference caused by such unauthorized modification, substitution or
attachment. Manufacturer and its authorized resellers or distributors will assume no liability for any damage or
violation of government regulations arising from failing to comply with these guidelines.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna
or transmitter.
Declaration of Conformity (R&TTE directive 1999/5/EC)
The following items were completed and are considered relevant and sufficient:
Essential requirements as in [Article 3]
Protection requirements for health and safety as in [Article 3.1a]
Testing for electric safety according to [EN 60950]
Protection requirements for electromagnetic compatibility in [Article 3.1b]
Testing for electromagnetic compatibility in [EN 301 489-1] & [EN 301]
Page iii
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
Testing according to [489-17]
Effective use of the radio spectrum as in [Article 3.2]
Testing for radio test suites according to [EN 300 328-2]
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN
OR MOISTURE. THE UNIT MUST NOT BE EXPOSED TO DRIPPING OR SPLASHING WATER.
CAUTION: DO NOT OPEN THE UNIT. DO NOT PERFORM ANY SERVICING OTHER THAN THAT
CONTAINED IN THE INSTALLATION AND TROUBLESHOOTING INSTRUCTIONS. REFER ALL
SERVICING TO QUALIFIED SERVICE PERSONNEL.
CAUTION: THIS DEVICE MUST BE INSTALLED AND USED IN STRICT ACCORDANCE WITH THE
MANUFACTURER’S INSTRUCTIONS AS DESCRIBED IN THE USER DOCUMENTATION THAT
COMES WITH THE PRODUCT.
WARNING: POSTPONE INSTALLATION UNTIL THERE IS NO RISK OF THUNDERSTORM OR
LIGHTNING ACTIVITY IN THE AREA.
When using this device, basic safety precautions should always be followed to reduce the risk of fire, electric shock
and injury to persons, including the following:
Read all of the instructions {listed here and/or in the user manual} before you operate this equipment.
Give particular attention to all safety precautions.
Retain the instructions for future reference.
Comply with all warning and caution statements in the instructions.
Observe all warning and caution symbols that are affixed to this equipment.
Comply with all instructions that accompany this equipment.
Avoid using this product during an electrical storm. There may be a risk of electric shock from lightning. For
added protection for this product during a lightning storm, or when it is left unattended and unused for long
periods of time, unplug the power supply, and disconnect the Cat 5e to the WAP at the Power Inserter. This will
prevent damage to the product due to lightning and power surges. It is recommended that the customer install an
AC surge protector in the AC outlet to which this device is connected. This is to avoid damaging the equipment
by local lightning strikes and other electrical surges. A Data Surge Conditioning Unit is also available from On-
Q/Legrand (364598-01) to help protect the data connection from the Power Injector to the WAP.
Operate this product only from the type of power source indicated on the product’s marking label.
If you are not sure of the type of power supplied to your home, consult your dealer or local power company.
Upon completion of any service or repairs to this product, ask the service technician to perform safety checks to
determine that the product is in safe operating condition.
Installation of this product must be in accordance with national wiring codes and conform to local regulations.
Place Power Inserter to allow for easy access when disconnecting the power cord/adapter of the device from the AC
wall outlet.
Wipe the unit with a clean, dry cloth. Never use cleaning fluid or similar chemicals. Do not spray cleaners directly on
the unit or use forced air to remove dust.
When not utilizing the recommended 3 gang plastic switch & outlet box, do not directly cover the device, or block the
airflow to the device with insulation or any other objects.
Keep the device away from excessive heat and humidity and keep the device free from vibration and dust.
Page iv
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
TABLE OF CONTENTS
I. Introduction 1
II. Product Overview 2
A. Features 2
B. Components Included 2
C. Replacement Parts 2
D. Detailed Physical Description 2
III. Installation 5
A. Rough-In Steps 5
B. Trim-Out Steps 6
IV. Basic Configuration 8
A. Configuring a Network Interface Card to talk to a WAP 9
B. Logging on to the WAP 11
C. Initial Wireless Access Point Setup 12
D. Returning the PC to DHCP Control 14
V. Advanced Configuration 17
A. Wireless Interface Configuration 17
B. Wireless Bridge Configuration 18
C. Wireless Access Control Configuration 19
D. Wireless RADIUS Setting Configuration 20
E. Wireless Advanced Configuration 21
F. System Setup Global Settings 22
G. System Setup Operation Mode 23
H. System Setup Firmware Upgrade 23
I. System Setup Setting Management 24
J. System Setup Factory Default 24
K. System Status 25
L. Wireless Status 25
VI. Troubleshooting 26
A. Contact Information 26
B. Hardware Situations 26
C. Software Situations 29
VII. Glossary 31
Page 1
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
I. Introduction
The On-Q/Legrand Wireless Access Point (WAP) 802.11g In-Ceiling or In-Wall unit (shown in Figure
1) uses a radio transmission technology defined by the Institute of Electrical and Electronics
Engineers (IEEE). This standard is subdivided into distinct categories of speed and the frequency
spectrum used, designated by the lower case letter after the standard. Your On-Q WAP 802.11g
supports both the 802.11b and 802.11g specifications.
The 802.11b specification transmits data rates up to 11 Mbps while the 802.11g specification transmits
data rates up to 54 Mbps. These are theoretical speeds so your performance may vary. The radio
waves radiate out in a donut-shaped pattern. The waves travel through walls and floors, but
transmission power and distance are affected. The following chart shows how the wireless range is
different for each data rate and also depends on the local conditions:
Data Rate Open Area Closed Area
54 Mbps Up to 100 ft. Up to 60 ft.
11 Mbps Up to 900 ft. Up to 160 ft.
5.5 Mbps Up to 1300 ft. Up to 200 ft.
2 or 1 Mbps Up to 1500 ft. Up to 300 ft.
Typically, the best performance can be expected by positioning it in the ceiling or wall at a central
location on the top floor of the home or where a localized “hot spot” is desired.
The following recommendations help you achieve the best wireless performance environment:
Placing the WAP in the physical center of your network is the premium location because the
antenna radiates out the signal in all directions.
Placing the WAP in a higher location helps to disperse the signal cleanly, especially to receiving
locations on upper stories.
Direct line of sight achieves better performance, but obviously is not always achievable.
Try to avoid placing the WAP next to large solid or dense objects like walls, fireplaces, etc. This
helps the signal penetrate more cleanly.
Other wireless devices like televisions, radios, microwaves and 2.4 GHz cordless telephones can
interfere with the signal. Keep devices away from the unit.
Mirrors, especially silver-coated, negatively affect transmission performance.
Your On-Q WAP 802.11g is powered over the single Cat 5e cable that connects it to the service
provider. A power supply inserts power onto the Cat 5e cable through an inserter module, and then
this power is extracted for use at the WAP location. In this way, unsightly power cables are avoided at
the WAP location.
Figure 1
P/N 364887-01 P/N 364891-01
Page 2
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
II. Product Overview
A. Features
Compatibility with both 802.11g and 802.11b standards
Wireless security via Wired Equivalent Privacy (WEP) and WiFi Protected Access (WPA)
encryptions
Firmware upgrades available to stay current with latest specification
B. Components Included
The On-Q WAP 802.11g (either In-Ceiling or In-Wall version) includes the following components:
WAP Assembly
WAP Cover
WAP 24VDC Power Supply with AC cord
WAP Power Over Cat 5e Inserter Module
Cat 5e Jumper Cable
The WAP Owner’s Manual on CD
WAP IS Sheet and User Guide
C. Replacement Parts
Replacement parts available for the On-Q WAP 802.11g include:
WAP 24 VDC Power Supply with AC cord (P/N 364889-01)
WAP Power Over Cat 5 Inserter Module (P/N 364888-01)
D. On-Q WAP 802.11g Detailed Physical Description
The following information describes the physical characteristics of the WAP Assembly.
1. WAP Assembly Connections (P/N 364887-01 shown)
Figure 2 shows the WAP Assembly connection area including:
Cat 5e from Power Inserter in enclosure “INPUT” connection
2. Connection Area Detailed Description
Figure 2
Page 3
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
INPUT – This RJ-45 connector is where the Cat 5e cable from the Power Over Cat 5e
Inserter Module in the On-Q Enclosure plugs in. There is an Extractor Module in the WAP
Assembly that breaks out the required DC power from the data on the input Cat 5e cable
connection.
NOTE: Notice in Figure 2 that there is also a small factory installed jumper cable that
supplies the required DC power and data to the WAP assembly.
3. WAP Assembly Status Indications (P/N 364891-01 shown)
Figure 3 shows the WAP 802.11g Assembly status indicators, which are visible when the
WAP cover is properly installed:
4. Status Indicators Detailed Description:
Data Indicator
ON (Blue) – The device is connected to a data network.
OFF – The device is powered off or not connected to a data network.
Wireless Indicator
Blinking (Blue) – The device is transmitting or receiving data.
Power Indicator
ON (Blue) - The device is powered on and operating normally.
OFF – The device is powered off or performing a boot sequence.
Blinking (Blue) Firmware upgrade failed.
5. WAP 802.11g Reset Button Access
Figure 4 shows the WAP 802.11g with the cover removed to gain access to the Reset
Button. As shown, there is a tab that when pushed in the direction shown will activate the
Reset Button. Pushing and holding this tab for five seconds or more will return the unit to
factory hardware default condition. This is particularly handy if someone configured a security
level or IP Address by mistake that prohibits you from gaining access to the unit.
Figure 3
Powe
r
Wireless
Data
Page 4
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
NOTE: Although the WAP is shipped from On-Q with its IP address set to 192.168.40.1 (in
the On-Q product 192.168.40.xxx sub-network), if you push the reset button for five
seconds, the WAP is reset to the factory default IP address of 192.168.1.220, and will have
to be re-configured to the 192.168.40.xxx sub-network to work with the other On-Q
products.
6. WAP 802.11g Power Over Cat 5e Inserter Module
Figure 5 shows the WAP Inserter Module components:
Figure 5
24VDC in from Power Supply
Data and Power out to WAP
Data in from ISP
Figure 4
Page 5
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
III. Installation
The On-Q WAP 802.11g is best installed during new construction in two steps; at “rough-in” with
the other low voltage cabling such as TV and Phone, but prior to drywall being installed, and at
“trim-out” after the drywall is installed and painted. These steps are detailed below:
A. “Rough-in” steps:
1. A single Cat 5e should be run in the walls from a plastic triple gang box (not supplied) at
the location in the home where the On-Q Wireless Access Point (WAP) will be installed to
the location where the Power Inserter Module will be located (On-Q enclosure) leaving
extra cable at both ends.
NOTE: The preferred location for the WAP 802.11g is in the ceiling or wall of the top
floor, centrally located in the home (see Figure 6). If multiple WAPs are used, they
should be located in overlapping wireless zones.
Figure 6
Page 6
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
B. “Trim-out” steps:
1. The Cat 5e cable that was run from the triple gang plastic box to the enclosure should be
pulled out of the box and terminated with an RJ-45 plug as shown in Figure 7.
NOTE: Use proper tools and standard TIA 568A rules to prep and terminate the Cat 5e
cable, such as the On-Q Cat 5 Cable Stripper (P/N 363292-01) and the On-Q EZ RJ45
Crimp Tool (P/N 364555-01).
2. It should then be plugged into the “INPUT” connector on the rear of the WAP Assembly as
shown in Figure 8.
3. The On-Q WAP 802.11g Assembly can then be screwed into the triple gang box and the
cover inserted, insuring that the LEDs on the WAP line up with the holes in the cover (see
Figure 9).
Figure 7
Figure 9
Figure 8
Page 7
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
4. In the structured wiring enclosure (see Figure 10) the Cat 5e from the WAP 802.11g can be
terminated with an RJ45 plug which is then connected directly to the output of the Power over
Cat 5e Inserter Module (P/N 36488-01).
5. A supplied Cat 5e patch cable is then connected from the input RJ-45 jack of the Power over
Cat 5e Inserter Module to one of the LAN ports on the On-Q or third party Router, or directly
to a Broadband Modem.
6. The Power over Cat 5e Inserter Module is powered with a 24 Volt DC power supply which
needs to be plugged in to an AC source.
7. When the 24 VDC Power Supply is plugged in to an active AC Source, verify that the Power
LED is lit on the Power Inserter.
8. Next, verify that the Power LED is lit on the WAP.
9. If you connected to an active network, verify that the Network Activity LED is lit on the
network access device and on the WAP.
10. Then, verify the Wireless LED is lit on the WAP.
Figure 10 Data/Power
out to WAP
Data in from ISP
Cat 5e
patch cable
Power Over
Cat5e Inserter
Module
Router/
Switch
Page 8
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
IV. Basic Configuration
The On-Q WAP 802.11g is typically configured in one of two ways; (1) From a portable PC connected
through the “Data In” port of the Power Inserter Module in the enclosure which is then connected
through its “Data/Power Out” port to a Cat 5e cable to the WAP, or (2) From a PC in one of the rooms
of the house, connected through an outlet in the room to the enclosure where it is patched to the
“Data In” port of the Power Inserter Module in the enclosure which is then connected through its
“Data/Power Out” port to a Cat 5e cable to the WAP (see Figure 11). In either case, the PC must
have an Ethernet Network Interface Card to communicate with the WAP.
NOTE: The On-Q WAP 802.11g can also be configured from a PC containing a Wireless Network
Interface Card for your desktop PC, or wireless PCMCIA card for your laptop PC, but this is not
recommended because it is not secure until you have configured security levels on the WAP
NOTE: Before configuring the On-Q WAP 802.11g, you must first temporarily configure your
computer (with installed Ethernet Network Interface Card) to talk to the WAP. Your On-Q WAP
comes from On-Q configured with a specific IP address (192.168.40.1), which is in the On-Q
product sub-network (192.168.40.xxx) for other networking products from On-Q. But, if it was reset
at any time, its hardware default IP address is 192.168.1.220, so your PC’s Ethernet Card must be
assigned an IP address, (like 192.168.40.10 or 192.168.1.10 as appropriate), on the same sub-
network to talk to and configure the WAP. Giving the PC a specific IP address is also called
assigning it a Static IP address, as compared to a Dynamic IP address that is typically assigned
by a service provider through a process called Dynamic Host Configuration Protocol (DHCP).
NOTE: Before doing any PC IP Address re-configuration, make sure you first write down all of the
current IP settings. If your PC is running XP, you may want to first create a manual system restore
point (under Accessories/System Tools/System Restore).
NOTE: After initially configuring the WAP, using that Static IP Address that you assign, you may
need to return the PC’s IP Address setting to be dynamically assigned by DHCP, if that is what the
service provider requires. If you are using a router, you will also want to change your WAP’s IP
address and Gateway settings to be on the same sub-network as the router.
Figure 11
Page 9
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
A. Configuring a Windows XP Ethernet Network Interface Card to talk to the WAP
This section includes information on configuring computers with the Windows XP operating
system (differences for Windows 2000 and Vista will be sited).
NOTE: This configuration assumes you have retained the default interface for Windows XP. If
you are running the “Classic” interface, please note any sited differences for Windows 2000 or
Vista.
1. Click Start.
2. Select Control Panel.
(For Windows 2000, select Settings first)
3. Double-click Network and Dial-Up Connections.
(For Vista double click Network and Sharing Center)
4. Double-click Local Area Connection. The Local Area Connection Status window appears
(see Figure 12).
(For Vista, click View Status next to Local Area Connection)
5. Click the Properties button to go to the Local Area Connection Properties screen.
(For Vista, you may need to click on Continue under the User Account Control popup)
Figure 12
Page 10
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
6. Ensure the box next to Internet Protocol (TCP/IP) is selected (see Figure 13).
(For Vista, use Internet Protocol Version 4 (TCP/IPv4)
7. Click to highlight Internet Protocol (TCP/IP) and click the Properties button to go to the
Internet Protocol (TCP/IP) Properties screen.
8. Click on “Use the following IP Address:” so that the circle is filled (see Figure 14).
Figure 13
Figure 14
Page 11
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
9. For a new WAP from On-Q on the 192.168.40.xxx sub-network, enter 192.168.40.10 into the
IP Address field, or for a WAP that has been reset, enter 192.168.1.10 into the IP Address
field.
10. Enter 255.255.255.0 into the Subnet Mask field.
11. Click OK twice to exit and save your settings.
(For Windows 2000 you will have to restart the computer to save these settings).
12. After the reboot (if appropriate), proceed to the next section to set up the WAP security
settings.
B. Logging on to the WAP
1. Once the PC’s Ethernet Interface Card is configured on the WAP’s sub-network, open your
web browser and Enter into the URL field http://192.168.40.1 (the WAP’s IP address on the
On-Q sub-network) or http://192.168.1.220 (the WAP’s IP address after a hardware reset)
and press Enter (see Figure 15).
The login screen will appear (see Figure 16).
2. Enter the User ID. The default setting is ”admin”, without the quotation marks.
3. Enter the Password. The default setting is “admin”, without the quotation marks and click on
“OK”.
Figure 15
Figure 16
htt
p
://192.168.1.220
Page 12
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
NOTE: Once you have logged in, for security reasons, you may want to change the logon
Password. Be sure to document the new Password. For details on changing your
Password see the System Setup section under Advanced Settings.
C. Initial Wireless AP Setup
Follow these procedures to setup your On-Q WAP and make it part of your Home Network.
1. When you logon the WAP, the Quick Setup screen is displayed (see Figure 17). Click on
Advanced Setting.
NOTE: As shown in Figure 17, the On-Q WAP can act as one of four different devices.
On-Q utilizes it as an Access Point (or AP) for the On-Q WAP application and will
concentrate on that portion of its functionality for the rest of this documentation.
2. Once you have selected Advanced Setting, you will see a screen (see Figure 18) that
allows you to select any of the Advanced Settings by clicking on one from the list down the
left side of the screen. At this point click on System Setup.
Figure 17
Figure 18
Page 13
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
3. When you click on System Setup, a drop down menu will appear under System Setup (see
Figure 19) that enables you to configure global settings (like Password or the language used
throughout the rest of the configuration). Notice this is also where you perform Firmware
Upgrades and another way of returning to factory hardware defaults. At this point, click on
Operation Mode to further define the device as an Access Point.
4. Click on Operation Mode and change the device from Home Gateway to Access Point by
clicking in the circle next to the Access Point area. Then click on Apply at the lower right
corner of the screen. (see Figure 20).
Figure 20
Figure 19
Page 14
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
5. Next you need to change how the On-Q WAP gets its IP Address (manually instead of
automatically) and give it an IP address that will work with the rest of the On-Q Data Products
in the 192.168.40.xxx sub-network. Click on “IP Config” from the list on the left of the screen
and you will see the IP Config – LAN screen (see Figure 21).
6. First, insure the answer to the Get IP Automatically? question is No rather than Yes, as you
want to manually give your WAP an IP address in the On-Q sub-network (see Figure 21).
7. Then type in your preferred IP Address (192.168.40.1) as shown in Figure 21.
8. Then click on Apply and finally Finish. This completes the initial Wireless Access Point
configuration, which allows your WAP to work with the rest of the Data Products in your On-Q
Home Network. The rest of this documentation relates to the other configurable parameters
of the On-Q WAP.
D. Returning the PC used to configure the WAP to DHCP control
1. Click Start.
2. Select Control Panel.
(For Windows 2000, select Settings first)
3. Double-click Network and Dial-Up Connections.
(For Vista double click Network and Sharing Center)
4. Double-click Local Area Connection. The Local Area Connection Status window appears
(see Figure 22).
(For Vista, click View Status next to Local Area Connection)
Figure 21
Page 15
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
5. Click the Properties button to go to the Local Area Connection Properties screen (see
Figure 23).
(For Vista, you may need to click on Continue under the User Account Control popup)
6. Ensure the box next to Internet Protocol (TCP/IP) is selected (see Figure 23).
(For Vista, use Internet Protocol Version 4 (TCP/IPv4)
Figure 22
Figure 23
Page 16
301 Fulling Mill Road, Suite G ©Copyright 2007 by On-Q/Legrand, Inc All Rights Reserved.
Middletown, PA 17057 www.onqlegrand.com
(800)-321-2343
NOTE: Although this series of steps is used to re-configure the PC from direct WAP
configuration back to its previous use as a DHCP controlled PC on the Router network,
they can also be used to configure the WAP Network Interface Card for DHCP control
by selecting the WAP NIC at the top of this screen.
7. Click to highlight Internet Protocol (TCP/IP) and click the Properties button to go to the
Internet Protocol (TCP/IP) Properties screen (see Figure 24).
8. Select Obtain an IP address automatically (see Figure 24).
9. Click OK twice to exit and save your settings.
(For Windows 2000 you will have to restart the computer to save these settings).
10. After the reboot (if appropriate), your PC should be now be ready for operation as before,
directly through the On-Q Router, or through the On-Q WAP (if a Wireless NIC card was
installed).
Figure 24
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43

On-Q 364891-01 Owner's manual

Category
Networking
Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI