Marathon Computer FTvirtual IBM BladeCenter User manual

Category
Servers
Type
User manual

This manual is also suitable for

Marathon Technologies FTvirtual
Server
TM
and IBM BladeCenter
TM
Installing and Configuring a Fault-Tolerant Windows
Environment for Mission Critical Applications
Marathon Technologies Corporation
www.marathontechnologies.com
888.682.1142
Notices
Marathon Technologies Corporation reserves the right to make
improvements to this guide and the product it describes at any
time and without further notice.
Copyright
© Marathon Technologies Corporation. 1996-2005. All rights
reserved.
This guide is copyrighted, and all rights are reserved. No part of
this guide or the products it describes may be reproduced by any
means or in any form, without prior consent in writing from
Marathon Technologies Corporation.
Printed in the U.S.A.
U.S. Patent Numbers: 5,600,784; 5,615,403; 5,787,485;
5,790,397; 5,896,523; 5,956,474; 5,983,371; 6,038,685;
6,205,565; and 6,728,898.
European Patent Numbers: EP0974912; EP0731945;
EP0993633; EP0986784; and EP1000397.
Other patents pending.
Software Copyright Notice
The software described in this document is covered by the
following copyright:
© Marathon Technologies Corporation. 1996-2005.
Trademark Notice
Endurance, Marathon Assured Availability, Marathon
FTvirtual Server, and the Marathon logo are either regis-
tered trademarks or trademarks of Marathon Technolo-
gies Corporation in the United States and/or other
countries.
Microsoft, MS-DOS, and Windows are registered trade-
marks of Microsoft Corporation in the United States and/
or other countries.
IBM eServer BladeCenter and IBM are registered trade-
marks of the International Business Machines Corpora-
tion in the United States and/or other countries.
All other brands and product names are trademarks of
their respective companies or organizations.
Software Revision
The revision of the software that this document supports is
Revision 6.1.1.
This section describes the technical changes made in
this edition of the Marathon Technologies FTvirtual Serv-
er
TM
and IBM eServer BladeCenter
TM
- A Fault-Tolerant
Environment for Mission Critical Windows Applications
application note. Minor changes and editorial corrections
may also be included that are not identified.
Summary of changes
Summary of changes for
Marathon Technologies FTvirtual Server and IBM
eServer BladeCenter
TM
- A Fault-Tolerant Environment
for Mission Critical Windows
as created or modified on 9/2/05.
September 2005, First Edition
1.0.0
Marathon Technologies Corporation 1
Contents
Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
Copyright . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
Software Copyright Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
Trademark Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Software Revision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
September 2005, First Edition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .iv
CHAPTER 1 Introduction
Fault-Tolerant Computing for Mission Critical Windows Applications . . . . . . . . . . . . . . . . . . . . 1
The Trend Toward Blades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Mission-Critical Blades: The Need For Fault Tolerance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Marathon FTvirtual Server - Fault-Tolerance Through Software . . . . . . . . . . . . . . . . . . . . . . . . 3
Conclusion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 2 Planning and Preparation
Planning the Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FTvirtual Server Boot Disk Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Network Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CoServer and Switchbay Network Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure - Sample BladeCenter Network Adapter Switchbay Map. . . . . . . . . . . . . . . . . . . . . 7
Network Adapter Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table - 4 NIC Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table - 3 NIC Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table - 3 NIC Alternate Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table - 2 NIC Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Preparing to Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
BladeCenter Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
FTvirtual Server and Blade Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Identifying Network Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Mapping the Switchbays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Table - Adapter PCI-to-Switchbay Mappings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Contents
Contents
2 Marathon Technologies Corporation
CHAPTER 3 Installing the Endurance Software
Major Installation Tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Windows Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Installing Windows on the CoServers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Event Log Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Disk Partitioning and Formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Installing the FTvirtual Server Boot Disk on a Physical Disk . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Installing Endurance Software on the CoServers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Before You Begin the Software Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
CoServer 1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Starting the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Specify the Location of the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Configure the Network using the Endurance Network Setup Wizard . . . . . . . . . . . . . . . . . . . . 21
Table - Suggested CoServer1 CLink IP Addresses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
CoServer 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table - Suggested CoServer2 CLink IP Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Installing Windows on and Configuring the FTvirtual Server . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Select CoServer Devices for FTvirtual Server Use and Configure the FTvirtual Server Disk . 34
Install Windows on the FTvirtual Server Disk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Finish the Windows Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Install the Endurance FTvirtual Server Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Specify the Location of the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Finish the FTvirtual Server Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Verifying the FTvirtual Server Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
What to do Next . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Marathon Technologies Corporation 1
CHAPTER 1 Introduction
Fault-Tolerant Computing for Mission Critical
Windows Applications
The Trend Toward Blades
Blade configurations like the IBM BladeCenter have become popular
because they provide several key advantages over conventional pedestal
or rack-mounted servers. These advantages include:
Flexibility and Ease of Installation
Because blades get their electrical power and network interconnections
from the chassis, adding processing power to an existing chassis is as
simple as inserting the blade and configuring its software and network
address. No additional cabling or electrical power connections are
required.
Ease of Management
System management tools like the IBM Director permit hundreds of
blade servers to be maintained remotely through use of a single graphi-
cal console. This tool provides a common management view across
multiple servers in a chassis and enables a smaller IT staff to manage
the same number of servers.
This chapter discusses the key advantages of IBM BladeCenter and Mara-
thon Technologies FTvirtual Server and how they combine to create a truly
fault-tolerant environment for mission critical Windows applications.
Introduction
2 Marathon Technologies Corporation
Reduced Floor Space Usage in the Data Center
Modular design reduces cost through more efficient use of valuable floor
space. The increased density can significantly reduce the space require-
ments in a data center.
Reduced Cost of Power and Cooling
Blades servers integrate resources and share key components. Since
blades in a chassis share common power supplies, power is distributed
more efficiently and less heat is generated for a given amount of pro-
cessing power.
Increased Reliability and Availability
Since the BladeCenter may be configured with redundant hot-swap
power supplies and built-in network switches, it effectively eliminates
several key single points of failure and provides greater system availabil-
ity than conventional rack-mount servers. The BladeCenter also
reduces down-time due to server failure by making replacement of a
failed server easy.
Mission-Critical Blades: The Need For Fault Tolerance
As enterprises move more compute load to blade servers, blades are
becoming increasingly mission-critical. Because downtime has significant
associated costs - lost sales, decreased customer satisfaction, lost produc-
tivity - the need for a simple, affordable way to keep blades running continu-
ously is becoming urgent. Four trends are converging to further increase
the need for continuously available blades:
Improved server density and server consolidation increases the
potential risk to business operations in the event of downtime by
“putting all your eggs in one basket”
Increasingly stringent regulations require data retention and avail-
ability
More threats to security and physical systems
Increasing complexity of enterprise infrastructure, and impact of
system downtime
Marathon Technologies Corporation 3
Marathon
FTvirtual Server
- Fault-Tolerance Through Software
To address the need for continuous availability of mission-critical applica-
tions, Marathon Technologies has designed its FTvirtual Server software to
work with blade server configurations as well as traditional servers.
Marathon software harnesses the redundancy provided by two BladeCenter
servers to create a true, fault- tolerant environment for Windows applica-
tions.This is accomplished by loading the Marathon software on any two
blade servers and interconnecting them via the BladeCenter’s integrated
chassis switching matrix. The Marathon software synchronizes the two
servers and creates a virtual application environment that runs on both
servers simultaneously. If either server in the connected pair fails, the appli-
cation environment continues to function uninterrupted, using the process-
ing power of the other. Unlike typical clustering technologies which require
seconds or even minutes to “fail-over” application processing and may
incure data loss, there is no failover with Marathon software, so there is no
downtime.
The result is a truely fault-tolerant Windows environment for BladeCenter
configurations. Enterprises get all the cost savings and operational efficien-
cies of the BladeCenter while protecting their business-critical Windows
applications and data, even in the event of a blade failure.
Conclusion
Blade servers are helping companies save money and increase efficiency
and flexibility in their data centers. However, without adequate fault protec-
tion, these benefits are soon lost in the event of downtime. Marathon’s
FTvirtual Server software delivers a simple, affordable way to protect impor-
tant applications and data running on IBM eServer BladeCenter configura-
tions.
Introduction
4 Marathon Technologies Corporation
Marathon Technologies Corporation 5
CHAPTER 2 Planning and Preparation
Planning the Installation
Before starting the Endurance software installation you should consider
several major configuration related issues, which will effect the overall oper-
ation and capability of your FTvirtual Servers.
FTvirtual Server Boot Disk Options
The Endurance software allows the FTvirtual Server boot disk to be
installed on either a separate physical disk or as a Virtual disk. If your blade
configuration is limited to a single on-board physical disk you will need to
use a Virtual boot disk for the FTvirtual Server. A virtual boot disk allows
you to share a single physical disk as both the CoServer and the FTvirtual
Server Windows boot disk. Disk space is allocated to a file on the CoServer
disk. The content of the file is then formatted, partitioned, and used as the
FTvirtual Server boot disk.
This chapter describes BladeCenter features and options, key design con-
cepts, and basic configuration guidelines you should be aware of before
beginning to install and setup a BladeCenter FTvirtual Server.
Planning and Preparation
6 Marathon Technologies Corporation
Network Environment
The optimal FTvirtual Server configuration uses 4 network adapters per
blade to support CoServer communications and client access links critical
to applications. These links provide the mechanisms and transport for redi-
rected network I/O, FTvirtual Server communications and fault manage-
ment activities.
When using the optimal network configuration, two of the adapters in each
blade will support CoServer Links (CSLink) 1 and 2, which are primarily
used for disk mirroring and memory synchonization operations. A third
adapter in each blade is used for CoServer out-of-band remote administra-
tion and SNMP management activities. The fourth serves as a redirected
network link permitting the FTvirtual Server to satisfy client and application
I/O requests.
CoServer and Switchbay Network Connections
A sample BladeCenter network map depicting the connections for two
FTvirtual Server configurations (FTv1 and FTv3) is shown in Figure 1. This
configuration demonstrates the optimal BladeCenter FTvirtual Server con-
figuration, maximizing server fault-tolerance and network availability.
It should be mentioned that although each switchbay is internally intercon-
nected with each slot of the BladeCenter chassis, these additional connec-
tions have been left out of the diagram for the sake of simplicity.
Note that in this 4 NIC configuration switchbays 1 and 2 provide dedicated
CSLink 1 and CSLink 2 switching capability for each of the FTv CoServers.
These connections are made internally to the BladeServer chassis and
none of the external ports available on these two switches are used for
external connections.
Switchbays 3 and 4 are configured for FTvirtual Server Redirected and
Management use. The four external ports available on these switches are
used to connect the FTvirtual Server/s to the public network.
Marathon Technologies Corporation 7
FIGURE 1.
FTv1 CoServer 1
PCI 1:0:0 NIC
Switch Bay 1
CSLink 1 connections only
No external connections
PCI 1:0:1 NIC
PCI 2:2:1 NIC
PCI 2:2:0 NIC
Switch Bay 2
CSLink 2 connections only
No external connections
Switch Bay 3
Redirected for CoServer 1
Management for CoServer 2
Switch Bay 4
Redirected for CoServer 2
Management for CoServer 1
FTv1 CoServer 2
PCI 1:0:0 NIC
PCI 1:0:1 NIC
PCI 2:2:1 NIC
PCI 2:2:0 NIC
FTv3 CoServer 2
PCI 1:0:0 NIC
PCI 1:0:1 NIC
PCI 2:2:1 NIC
PCI 2:2:0 NIC
FTv3 CoServer 1
PCI 1:0:0 NIC
PCI 1:0:1 NIC
PCI 2:2:1 NIC
PCI 2:2:0 NIC
To
Network
To
Network
Blade Bays 1, 5, 9 are assumed to contain CoServer 1
Blade Bays 3, 7, 11 are assumed to contain CoServer 2
Blade Bay pairs 1 & 3, 5 & 7, 9 & 11 each make an Endurance system
FTv2 CoServer 1
FTv2 CoServer 2
Sample BladeCenter Network Adapter Switchbay Map
Planning and Preparation
8 Marathon Technologies Corporation
Network Adapter Configurations
Depending upon your specific switchbay and blade on-board device config-
uration, it is possible that fewer than 4 adapters will be available for use.
When planning a BladeCenter network configuration your primary concern
should be to maximize the availability of the redirected network links and
minimize utilization of external networks by the CoServer links.
To maximize the availability of the redirected links, different switches
should be used to connect the CoServers to the external network. To mini-
mize utilization of the external network by the CoServer links, both CoServ-
ers should use the same internal switch for a CSLink connection. Routing a
CSLink connection through the same switch will confine all associated traf-
fic to that switch. Several recommended network configurations using 4, 3,
and 2 network adapters are shown in the following tables.
TABLE 1. 4 NIC Configuration
Function CoServer 1 CoServer 2 Comment
CSLink 1 Switchbay 1 Switchbay 1 Internal Bandwidth
CSLink 2 Switchbay 2 Switchbay 2 Internal Bandwidth
Redirected Switchbay 3 Switchbay 4 Redundant External Connection
Manage Switchbay 4 Switchbay 3 Redundant External Connection
TABLE 2.
3 NIC Configuration
Function CoServer 1 CoServer 2 Comment
CSLink 1 Switchbay 1 Switchbay 1 Internal Bandwidth
Redirected Switchbay 2 Switchbay 3 Redundant External Connection
CSLink 2 Switchbay 3 Switchbay 2 Exposed network utilization
Requires network routed IP
addresss
TABLE 3.
3 NIC Alternate Configuration
Function CoServer 1 CoServer 2 Comment
CSLink 1 Switchbay 1 Switchbay 1 Internal Bandwidth
Redirected Switchbay 2 Switchbay 3 Redundant External Connection
Manage Switchbay 3 Switchbay 2 Redundant External Connection
Marathon Technologies Corporation 9
For More Information
For more information on setting-up network configurations, Virtual boot
disks and other preparation issues consult the following resources located
on your Marathon software distribution CD-ROM:
Administrator’s Guide
Upgrading Endurance Software
Configuration and Installation Guide
TABLE 4. 2 NIC Configuration
Function CoServer 1 CoServer 2 Comment
CSLink 1 Switchbay 1 Switchbay 2 Exposed network utilization.
Requires network routed IP
address.
Redirected Switchbay 2 Switchbay 1 Redundant External Connection
Planning and Preparation
10 Marathon Technologies Corporation
Preparing to Install
BladeCenter Options
An IBM eServer BladeCenter
may be configured using a variety of storage
and networking options. For example, the BladeCenter chassis using HS20
blade servers offers the following configuration features:
A rack-optimized 7U modular 14 slot chassis that can support a
total of 14 hot-swap BladeCenter HS20 blades.
A CD-ROM and floppy shared by all blade bays.
A maximum of two Management modules integrating remote man-
agement functions and a 14-port Keyboard/Video/Mouse switch.
Up to 4 Gigabit Ethernet Switch modules. Each switch has four
external ports as well as 14 internal ports (one to each bay).
HS20 hot-swappable blades supporting two XEON processors, 4-
port Gigabit Ethernet modules, on-board disks and/or a piggy-
backed SCSI drive Expansion Unit.
Marathon Technologies Corporation 11
FTvirtual Server and Blade Configuration
Each Endurance FTvirtual Server configuration is comprised of two blades.
Following installation of the Endurance software each will function as a
CoServer to create the FTvirtual Server environment.
Depending upon the specific configuration, a 14 slot BladeCenter chassis
can support a total of 7 Endurance FTvirtual Servers (2 slots per FTvirtual
Server), using single-slot blades configured with one or two on-board disks
and four network adapters. If each blade is configured with four network
adapters and a piggy-backed SCSI Expansion Unit option for increased
storage capacity, a total of 3 Endurance configurations (4 slots per FTvirtual
Server) may be supported.
It is important to note that the chassis slot position of a blade has no impact
on its function. After an Endurance system has been established, the
blades can be moved to any chassis slot and located in any order. Data
communications between Endurance configured blades is controlled by IP
addresses, which are unique to a blade and FTvirtual Server blade pair.
Identifying Network Components
To help simplify Endurance software installation it is suggested that you first
create a chart that maps blade configured network adapters to their corre-
sponding ethernet switchbay connection. Since this mapping may vary
across blade (HSxx) models, it is important that you identify these connec-
tions prior to installation. Later, during the network setup phase of the instal-
lation you will be able to correlate a CoServer assigned networking role to
its corresponding adapter and ethernet switchbay connection.
A specific network adapter must be identified by its unique PCI bus location
in the system in terms of:
“PCI bus b, device d, function f
Switchbays may be identified from the back of the BladeCenter cabinet by
the number of the particular bay they reside in.
Planning and Preparation
12 Marathon Technologies Corporation
Mapping the Switchbays
After installation of the Windows operating system on a blade you can fill-in
the switchbay mapping table for your particular configuration using the fol-
lowing procedure.
Note: Do not perform PCI-to-Switchbay mappings when blades
within the chassis are operating within a production
environment.
1. On one of the CoServer blades right-click My Network Places to view
the Network Connections dialog.
2. From the back of the BladeCenter cabinet select a switchbay and unplug
it.
3. Return to the CoServer console and observe the Network Connections
dialog and note which connection experiences a status change.
4. Right-click on the connection that changed status to display the Local
Area Connection Properties.
5. Click the Configure button to display the controller properties. Note the
switchbay number of the switch you unpluged and record the corre
-
sponding PCI location information for that adapter in Table 4. Plug the
switchbay back into its slot and wait for the connection status to return to
normal.
6. Repeat this procedure for each configured ethernet switchbay until you
have identified all connections. Since these connections will hold for like
blade models this mapping will work for all other configured blades.
TABLE 5. Adapter PCI-to-Switchbay Mappings
Blade Model Switchbay 1 Switchbay 2 Switchbay 3 Switchbay 4
Blade HS20
8832 Chassis
1:0:0 (b:d:f) 1:0:1 (b:d:f) 2:2:1 (b:d:f)
2:2:0 (b:d:f)
Blade HS20
8843 Chassis
5:1:0 5:1:1 6:1:0 6:1:1
Blade HSXX
88nn Chassis
Marathon Technologies Corporation 13
CHAPTER 3 Installing the Endurance
Software
Major Installation Tasks
The major installation tasks are:
1. Install Windows on both CoServers.
2. Install Endurance software on CoServer 1.
3. Install Endurance software on CoServer 2.
4. Install Windows on and configure the FTvirtual Server
This chapter describes in detail how to install and configure the Endurance
software on each of the BladeCenter CoServers to create the FTvirtual
Server.
Installing the Endurance Software
14 Marathon Technologies Corporation
Windows Installation
Before you begin the Endurance installation, install Windows and set the
size of the event logs.
Installing Windows on the CoServers
On both CoServers:
Install the appropriate Windows software and Service Packs. Refer to the
Endurance Release Notes for information about hardware and software
requirements, including Windows Security Updates.
Note: If the Manage Your Server or Configure Your Server window
appears, click Don’t display this page at logon, and then
dismiss the window.
Event Log Recommendations
On both CoServers:
For best results in tracking system events, make sure that the Application
Log and System Log on both CoServers are set to at least 16384 KB.
From Computer Management, select Event Viewer. For each log:
Right click, and select Properties.
If necessary, change the Maximum log size to at least 16384 KB. Verify
that the Overwrite events as needed box is checked.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

Marathon Computer FTvirtual IBM BladeCenter User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI