Alcatel-Lucent 1643 AMS, 1643 AM Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Alcatel-Lucent 1643 AMS Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1643 Access Multiplexer AM / 1643
Access Multiplexer Small AMS
(Formerly Metropolis® AM /
Metropolis® AMS)
Release 1.0 through 7.2
Installation Guide
365-312-802R7.2
CC109635797
Issue 4
June 2007
Alcatel-Lucent - Proprietary
This document contains proprietary information of Alcatel-Lucent and
is not to be disclosed or used except in accordance with applicable agreements.
Copyright © 2007 Alcatel-Lucent
Unpublished and Not for Publication
All Rights Reserved
See notice on first age
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their
respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2007 Alcatel-Lucent. All Rights Reserved.
Notice
Every effort has been made to ensure that the information in this document was complete and accurate at the time of printing. However,
information is subject to change.
Release notification
This document describes AM and AMS release 7.2 and covers previous releases.
Compared to provided descriptions some of the legacy releases may vary due to the feature upgrades.
Safety
Always observe the Safety Instructions given in Chapter 1 when operating the system.
Please note that Alcatel-Lucent warranty is contingent upon the use of Alcatel-Lucent specified SFPs for AMS. Use of other SFPs is not
approved by Alcatel-Lucent and is fully at the customer’s own risk. Any warranty obligation of Alcatel-Lucent is extinguished when
non-Alcatel-Lucent specified SFPs are used.
Ordering information
The order number of this document is 365-312-802R7.2 (Issue 4).
Technical support
Please contact your Alcatel-Lucent Local Customer Support Team (LCS) for technical questions about the information in this document.
Information product support
To comment on this information product online, go to http://www.alcatel-lucent-info.com/comments or email your comments to
comments@alcatel-lucent.com.
See notice on first age
Alcatel-Lucent - Proprietary
See notice on first page
Contents
About this information product
Purpose
........................................................................................................................................................................................ xviixvii
Reason for reissue
................................................................................................................................................................... xviixvii
Safety information
..................................................................................................................................................................... xxxx
Intended audience
...................................................................................................................................................................... xxxx
How to use this information product
................................................................................................................................. xxxx
Conventions used
...................................................................................................................................................................... xxixxi
Related documentation
.......................................................................................................................................................... xxiixxii
Technical support
................................................................................................................................................................... xxiiixxiii
How to order
........................................................................................................................................................................... xxiiixxiii
How to comment
................................................................................................................................................................... xxiiixxiii
Part I: Physical and power installation
1 Safety
Overview
...................................................................................................................................................................................... 1-11-1
General notes on safety
Overview
...................................................................................................................................................................................... 1-31-3
Structure of hazard statements
............................................................................................................................................ 1-41-4
Basic safety aspects
................................................................................................................................................................. 1-81-8
Specific safety areas
Overview
...................................................................................................................................................................................... 1-91-9
Laser safety
.............................................................................................................................................................................. 1-101-10
Optical circuit pack specifications
.................................................................................................................................. 1-131-13
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
iii
Power supply safety instructions ..................................................................................................................................... 1-141-14
Electrostatic discharge
......................................................................................................................................................... 1-151-15
Conformity statements
......................................................................................................................................................... 1-161-16
2 General information
Overview
...................................................................................................................................................................................... 2-12-1
Hardware description
.............................................................................................................................................................. 2-22-2
Environmental considerations
........................................................................................................................................... 2-102-10
EMC/ESD information
........................................................................................................................................................ 2-122-12
ITM-CIT requirements
......................................................................................................................................................... 2-142-14
Required tools and test equipment
................................................................................................................................. 2-152-15
Sequence of steps
.................................................................................................................................................................. 2-162-16
3 Mechanical installation
Overview
...................................................................................................................................................................................... 3-13-1
1643 AM installation
Overview
...................................................................................................................................................................................... 3-23-2
Technical data for AM unit
.................................................................................................................................................. 3-33-3
Installation of an option card
.............................................................................................................................................. 3-73-7
Mounting the EMC bracket
................................................................................................................................................. 3-93-9
Technical data for fan unit
................................................................................................................................................. 3-103-10
AM unit installation
.............................................................................................................................................................. 3-123-12
1643 AMS installation
Overview
................................................................................................................................................................................... 3-193-19
Technical data for AMS unit
............................................................................................................................................. 3-203-20
Installation of an option card
............................................................................................................................................ 3-213-21
Mounting the EMC bracket
............................................................................................................................................... 3-233-23
Technical data for fan unit
................................................................................................................................................. 3-243-24
AMS unit installation
........................................................................................................................................................... 3-263-26
Contents
...................................................................................................................................................................................................................................
iv
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
4 System cabling
Overview
...................................................................................................................................................................................... 4-14-1
Power and ground cable installation
Overview
...................................................................................................................................................................................... 4-34-3
Power interfaces (AM unit)
................................................................................................................................................. 4-44-4
Power interfaces (AMS unit)
............................................................................................................................................... 4-64-6
Cabling with AC/DC converter
.......................................................................................................................................... 4-84-8
Ground wiring
......................................................................................................................................................................... 4-114-11
External cable installation
Overview
................................................................................................................................................................................... 4-124-12
Fan power interface
.............................................................................................................................................................. 4-134-13
Fan alarm and LED interface
........................................................................................................................................... 4-154-15
MDI/MDO interface
............................................................................................................................................................. 4-174-17
Timing interface
..................................................................................................................................................................... 4-234-23
Q-LAN interface (OMS)
..................................................................................................................................................... 4-254-25
ITM-CIT interface
................................................................................................................................................................. 4-274-27
EOW interfaces
....................................................................................................................................................................... 4-304-30
Option card cable installation
Overview
................................................................................................................................................................................... 4-324-32
E1 interfaces (Main board/X16E1-V3 card)
............................................................................................................... 4-334-33
DS1 interfaces (Main board/X16DS1 card)
................................................................................................................ 4-354-35
SHDSL interfaces (X12SHDSL-V2 card)
................................................................................................................... 4-374-37
E3 interfaces (X2E3 card)
.................................................................................................................................................. 4-404-40
DS3 interfaces (X2DS3 card)
........................................................................................................................................... 4-414-41
LAN interfaces (X4IP, X8PL and X5IP card)
........................................................................................................... 4-424-42
X.21 interfaces (X4X.21 card)
......................................................................................................................................... 4-454-45
STM-1e interfaces (X2STM1ETRIB card)
................................................................................................................. 4-474-47
Fiber cabling
Overview
................................................................................................................................................................................... 4-494-49
Contents
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
v
Optical interfaces (AM unit) ............................................................................................................................................. 4-504-50
Optical interfaces (AMS unit/X5IP card)
.................................................................................................................... 4-524-52
Aggregate interfaces (Main board)
................................................................................................................................. 4-554-55
Tributary interfaces (X2S11TRIB card)
....................................................................................................................... 4-574-57
5 Powering
Overview
...................................................................................................................................................................................... 5-15-1
Power initialisation
Overview
...................................................................................................................................................................................... 5-25-2
Switching on and testing supply voltage
........................................................................................................................ 5-35-3
Fan unit test
................................................................................................................................................................................ 5-45-4
Physical installation check
Overview
...................................................................................................................................................................................... 5-55-5
AM/AMS unit installation
.................................................................................................................................................... 5-65-6
Cable connections
.................................................................................................................................................................... 5-75-7
Physical and power installation exit checklist
............................................................................................................. 5-85-8
Part II: NE provisioning and stand-alone installation test
6 ITM-CIT installation and NE provisioning
Overview
...................................................................................................................................................................................... 6-16-1
Software installation
Overview
...................................................................................................................................................................................... 6-26-2
Installing ITM-CIT
.................................................................................................................................................................. 6-36-3
Installing the fast download application
......................................................................................................................... 6-66-6
Fast NE software download
................................................................................................................................................. 6-76-7
Connecting the ITM-CIT to the NE
.............................................................................................................................. 6-106-10
NE login procedure
............................................................................................................................................................... 6-126-12
Provisioning system parameters
Overview
................................................................................................................................................................................... 6-146-14
NE date and time
................................................................................................................................................................... 6-156-15
Contents
...................................................................................................................................................................................................................................
vi
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
Node creation .......................................................................................................................................................................... 6-176-17
Slot provisioning
.................................................................................................................................................................... 6-206-20
Confirm/Update the MIB
................................................................................................................................................... 6-226-22
7 Stand-alone test procedures
Overview
...................................................................................................................................................................................... 7-17-1
Test equipment and accessories
.......................................................................................................................................... 7-37-3
Preparation and test of the main unit
............................................................................................................................... 7-67-6
E1 tributary ports distribution wiring test
...................................................................................................................... 7-77-7
Line port connection to optical distribution frame test
............................................................................................ 7-97-9
PDH option card test
............................................................................................................................................................ 7-137-13
Optical STM-1 option card test
....................................................................................................................................... 7-167-16
X.21 option card test
............................................................................................................................................................ 7-197-19
X4IP, X8PL, and X5IP option card test
....................................................................................................................... 7-227-22
X12SHDSL-V2 option card test
...................................................................................................................................... 7-257-25
NE provisioning and stand alone installation test exit checklist
....................................................................... 7-287-28
Part III: Link testing
8 Link testing
Overview
...................................................................................................................................................................................... 8-18-1
Connecting the fiber cables
.................................................................................................................................................. 8-28-2
Remote login test
..................................................................................................................................................................... 8-48-4
BER test
....................................................................................................................................................................................... 8-68-6
Link testing exit checklist
..................................................................................................................................................... 8-88-8
9 Conclusion
Overview
...................................................................................................................................................................................... 9-19-1
Power supply measurements
................................................................................................................................................ 9-29-2
Optical output power measurements
................................................................................................................................ 9-39-3
Final checklist
............................................................................................................................................................................ 9-49-4
Completion form
....................................................................................................................................................................... 9-59-5
Contents
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
vii
A Mounting rules
Overview
..................................................................................................................................................................................... A-1A-1
AM/AMS units (DC powered)
.......................................................................................................................................... A-2A-2
AM/AMS units (AC powered)
.......................................................................................................................................... A-4A-4
B Installation trouble shooting
Overview
..................................................................................................................................................................................... B-1B-1
Power failure
............................................................................................................................................................................. B-2B-2
Installing the NE software
................................................................................................................................................... B-4B-4
Parameters for NE software installation
........................................................................................................................ B-7B-7
Software check (correct ISD)
............................................................................................................................................. B-9B-9
Fiber cleaning
......................................................................................................................................................................... B-10B-10
Removing the SFP modules
............................................................................................................................................. B-12B-12
C Cable assembly instructions
Overview
..................................................................................................................................................................................... C-1C-1
SUB-D connector
.................................................................................................................................................................... C-2C-2
Coax connector (1.6/5.6)
...................................................................................................................................................... C-5C-5
Mounting 4x2.5mm coax (75 Ω) to RJ45 connector
............................................................................................... C-8C-8
Glossary
Index
Contents
...................................................................................................................................................................................................................................
viii
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
List of tables
Part I: Physical and power installation
2 General information
2-1 Technical specifications (AC/DC converter)
................................................................................................ 2-22-2
2-2 Technical specifications (FSP12AMS)
............................................................................................................ 2-32-3
2-3 Available option cards
............................................................................................................................................ 2-72-7
2-4 Environmental conditions
................................................................................................................................... 2-102-10
2-5 Required tools
......................................................................................................................................................... 2-152-15
2-6 Required test equipment
..................................................................................................................................... 2-152-15
3 Mechanical installation
3-1 Technical specifications (AM unit)
.................................................................................................................. 3-33-3
3-2 Technical specifications (fan unit)
.................................................................................................................. 3-103-10
3-3 Technical specifications (AMS unit)
............................................................................................................. 3-203-20
3-4 Technical specifications (fan unit)
.................................................................................................................. 3-243-24
4 System cabling
4-1 Pin assignment (power cables, AM unit)
....................................................................................................... 4-44-4
4-2 Pin assignment (power cables, AMS unit)
.................................................................................................... 4-64-6
4-3 Parts (DIN rail)
......................................................................................................................................................... 4-94-9
4-4 Pin assignment (fan power cable)
.................................................................................................................. 4-134-13
4-5 Pin assignment (fan alarm cable)
................................................................................................................... 4-154-15
4-6 Pin assignment (MDI/MDO cable)
................................................................................................................ 4-194-19
4-7 Pin assignment (timing cable)
.......................................................................................................................... 4-234-23
4-8 Pin assignment (Q-LAN cable)
....................................................................................................................... 4-254-25
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
ix
4-9 Pin assignment (ITM-CIT cable) .................................................................................................................... 4-274-27
4-10 Pin assignment (EOW cables, valid for both connectors)
.................................................................... 4-304-30
4-11 Pin assignment (E1 cables)
............................................................................................................................... 4-334-33
4-12 Pin assignment (DS1 cables)
............................................................................................................................ 4-354-35
4-13 Pin assignment (SHDSL cables)
..................................................................................................................... 4-374-37
4-14 Pin assignment (LAN cables - E/FE)
........................................................................................................... 4-424-42
4-15 Pin assignment (LAN cable - GE)
................................................................................................................. 4-434-43
4-16 Pin assignment (X.21 cables)
........................................................................................................................... 4-454-45
4-17 Components (STM-1e cable)
............................................................................................................................ 4-474-47
4-18 Optical specifications
........................................................................................................................................... 4-504-50
4-19 Optical SFP specifications
................................................................................................................................. 4-534-53
List of tables
...................................................................................................................................................................................................................................
x
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
List of figures
Part I: Physical and power installation
2 General information
2-1 AC/DC converter
..................................................................................................................................................... 2-22-2
2-2 Remote Power Supply box
.................................................................................................................................. 2-32-3
2-3 Optical SFP module
................................................................................................................................................ 2-62-6
2-4 SFP155E module
...................................................................................................................................................... 2-62-6
2-5 Dust plug
..................................................................................................................................................................... 2-72-7
2-6 Example of an option card
................................................................................................................................... 2-92-9
3 Mechanical installation
3-1 Front view (AM unit)
............................................................................................................................................. 3-43-4
3-2 AM rear view with different option cards mounted
.................................................................................. 3-53-5
3-3 Location of an AM option card
......................................................................................................................... 3-83-8
3-4 Installed AM option card
...................................................................................................................................... 3-83-8
3-5 Mounting the EMC bracket (AM unit)
........................................................................................................... 3-93-9
3-6 Fan unit
...................................................................................................................................................................... 3-113-11
3-7 Fixing wall mounting brackets (AM unit)
.................................................................................................. 3-133-13
3-8 Vertical wall mounting (AM unit)
.................................................................................................................. 3-133-13
3-9 Horizontal wall mounting (AM unit)
............................................................................................................ 3-143-14
3-10 Fixing horizontal rack brackets (AM unit)
................................................................................................. 3-153-15
3-11 Bracket mounting (AM unit)
............................................................................................................................ 3-163-16
3-12 Vertical mounting (AM unit)
............................................................................................................................ 3-163-16
3-13 Mounted fan unit
................................................................................................................................................... 3-183-18
....................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
xi
3-14 Front view (AMS unit) ....................................................................................................................................... 3-203-20
3-15 Installation of an AMS option card
............................................................................................................... 3-223-22
3-16 Mounting the EMC bracket (AMS unit)
..................................................................................................... 3-233-23
3-17 Fan unit
...................................................................................................................................................................... 3-253-25
3-18 Fixing wall mounting brackets (AMS unit)
............................................................................................... 3-273-27
3-19 Vertical wall mounting (AMS unit)
............................................................................................................... 3-283-28
3-20 Horizontal wall mounting (AMS unit)
......................................................................................................... 3-293-29
3-21 Fixing additional brackets to the AMS unit (if required)
..................................................................... 3-303-30
3-22 Mounting position for MADM compact racks, Wavestar ADM 16/1 racks and DACS racks
............................................................................................................................................................................ 3-303-303-30
3-23 Mounting position for MADM universal racks and ETSI racks (depth 300 mm)
..................... 3-313-31
3-24 Mounting position for ADM 16/1 racks and ETSI racks (600 mm x 600 mm)
......................... 3-323-32
3-25 Mounting position for 19-inch racks
............................................................................................................. 3-333-33
3-26 Mounting position for ETSI-2 (LambdaUnite) racks (back-to-back, depth 600 mm)
.............. 3-343-34
3-27 Mounted AMS brackets
...................................................................................................................................... 3-353-35
3-28 Vertical AMS mounting (with bars)
............................................................................................................... 3-363-36
3-29 Fixing fan unit and brackets (AMS unit)
.................................................................................................... 3-373-37
3-30 Street cabinet mounting (AMS unit)
............................................................................................................. 3-373-37
4 System cabling
4-1 DC connector (AM unit)
....................................................................................................................................... 4-44-4
4-2 DC connection (AM unit)
.................................................................................................................................... 4-54-5
4-3 AC connection (AM unit)
.................................................................................................................................... 4-54-5
4-4 DC connector (AMS unit)
.................................................................................................................................... 4-64-6
4-5 DC connection (AMS unit)
.................................................................................................................................. 4-74-7
4-6 AC connection (AMS unit)
.................................................................................................................................. 4-74-7
4-7 Cabling with AC/DC converter
.......................................................................................................................... 4-84-8
4-8 DIN rail with one power supply
........................................................................................................................ 4-84-8
4-9 DIN rail with two power supplies
.................................................................................................................... 4-94-9
4-10 DIN rail without power supply (direct feed)
................................................................................................ 4-94-9
List of figures
...................................................................................................................................................................................................................................
xii
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
4-11 Fan power connector ............................................................................................................................................ 4-134-13
4-12 Fan power cable
..................................................................................................................................................... 4-144-14
4-13 Fan alarm and LED connector
......................................................................................................................... 4-154-15
4-14 Fan alarm cable
...................................................................................................................................................... 4-164-16
4-15 MDI circuit
............................................................................................................................................................... 4-174-17
4-16 MDI implementation
............................................................................................................................................ 4-184-18
4-17 MDO circuit
............................................................................................................................................................. 4-194-19
4-18 MDI/MDO connector
........................................................................................................................................... 4-194-19
4-19 MDI/MDO cable (AM unit)
............................................................................................................................. 4-214-21
4-20 MDI/MDO cable (AMS unit)
........................................................................................................................... 4-214-21
4-21 MDI/MDO cable (AMS unit to Remote Power Supply (FSP) unit)
............................................... 4-224-22
4-22 Timing connector
................................................................................................................................................... 4-234-23
4-23 Timing cable (AM unit)
...................................................................................................................................... 4-244-24
4-24 Timing cable (AMS unit)
................................................................................................................................... 4-244-24
4-25 Q-LAN connector
.................................................................................................................................................. 4-254-25
4-26 Q-LAN cable (AM unit)
..................................................................................................................................... 4-264-26
4-27 Q-LAN cable (AMS unit)
.................................................................................................................................. 4-264-26
4-28 ITM-CIT connector
............................................................................................................................................... 4-274-27
4-29 ITM-CIT cable (AM unit)
................................................................................................................................. 4-284-28
4-30 ITM-CIT cable (AMS unit)
............................................................................................................................... 4-284-28
4-31 ITM-CIT cable connection
................................................................................................................................ 4-294-29
4-32 EOW connector
...................................................................................................................................................... 4-304-30
4-33 EOW cables
............................................................................................................................................................. 4-314-31
4-34 E1 connector
............................................................................................................................................................ 4-334-33
4-35 E1 cables
................................................................................................................................................................... 4-344-34
4-36 DS1 connector
........................................................................................................................................................ 4-354-35
4-37 DS1 cables
................................................................................................................................................................ 4-364-36
4-38 SHDSL connector
.................................................................................................................................................. 4-374-37
4-39 SHDSL cables
......................................................................................................................................................... 4-394-39
List of figures
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
xiii
4-40 E3 cables ................................................................................................................................................................... 4-404-40
4-41 DS3 cables
................................................................................................................................................................ 4-414-41
4-42 LAN connector
....................................................................................................................................................... 4-424-42
4-43 Cable design (LAN cable - GE)
..................................................................................................................... 4-434-43
4-44 LAN cables (X4IP card)
..................................................................................................................................... 4-444-44
4-45 LAN cables (X8PL card)
................................................................................................................................... 4-444-44
4-46 X.21 connector
....................................................................................................................................................... 4-454-45
4-47 X.21 cables
............................................................................................................................................................... 4-464-46
4-48 Cable design (STM-1e cable)
........................................................................................................................... 4-474-47
4-49 STM-1e cables
........................................................................................................................................................ 4-484-48
4-50 Optical connectors
................................................................................................................................................. 4-504-50
4-51 Optical SFP module
.............................................................................................................................................. 4-524-52
4-52 Dust plug
................................................................................................................................................................... 4-534-53
4-53 Aggregate fiber cables (AM unit)
.................................................................................................................. 4-554-55
4-54 Aggregate fiber cables (AMS unit)
................................................................................................................ 4-564-56
4-55 Tributary fiber cables
........................................................................................................................................... 4-574-57
Part II: NE provisioning and stand-alone installation test
6 ITM-CIT installation and NE provisioning
6-1 Connection with crossed Ethernet cable (AM unit)
.................................................................................. 6-76-7
6-2 Connection with crossed Ethernet cable (AMS unit)
............................................................................... 6-86-8
6-3 ITM-CIT cable connection (AM unit)
.......................................................................................................... 6-106-10
6-4 ITM-CIT cable connection (AMS unit)
....................................................................................................... 6-116-11
7 Stand-alone test procedures
7-1 E1 tributary ports distribution wiring test
..................................................................................................... 7-77-7
7-2 Line port connection to optical distribution frame test
............................................................................ 7-97-9
7-3 PDH option card test
........................................................................................................................................... 7-137-13
7-4 Optical STM-1 option card test
....................................................................................................................... 7-167-16
7-5 X.21 option card test
............................................................................................................................................ 7-197-19
List of figures
...................................................................................................................................................................................................................................
xiv
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
7-6 X12SHDSL-V2 option card test ..................................................................................................................... 7-257-25
Part III: Link testing
8 Link testing
8-1 Remote login test
..................................................................................................................................................... 8-48-4
8-2 BER test
....................................................................................................................................................................... 8-68-6
A Mounting rules
A-1 Horizontal mounting (AM/AMS, DC)
........................................................................................................... A-2A-2
A-2 Vertical mounting (AM/AMS, DC)
................................................................................................................. A-3A-3
A-3 Vertical mounting (AM/AMS, AC)
................................................................................................................. A-4A-4
B Installation trouble shooting
B-1 Unlocking a MSA latch (type 1) SFP
.......................................................................................................... B-13B-13
B-2 Unlocking a MSA latch (type 2) SFP
.......................................................................................................... B-14B-14
B-3 Unlocking a bail latch (type 1) SFP
............................................................................................................. B-15B-15
B-4 Unlocking a bail latch (type 2) SFP
............................................................................................................. B-16B-16
C Cable assembly instructions
C-1 SUB-D assembly steps
.......................................................................................................................................... C-3C-3
C-2 Low frequency cable
............................................................................................................................................. C-4C-4
C-3 IMS assembly procedure
...................................................................................................................................... C-6C-6
C-4 Crimp tool and die
.................................................................................................................................................. C-7C-7
C-5 RJ45 connector
...................................................................................................................................................... C-11C-11
List of figures
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
Alcatel-Lucent - Proprietary
See notice on first page
xv
About this information productAbout this information product
Purpose
This manual provides information on the installation and configuration of 1643 AM
and 1643 AMS units. Furthermore, all steps for putting the system into operation are
also described.
Reason for reissue
This is the fourth issue of this guide for 1643 AM and 1643 AMS, Release 1.0 through
7.2.
Note
The 1643 AM / 1643 AMS Installation Guide contains images with old logos and will
be replaced in forthcoming releases.
Previous versions and features are listed below:
Release GA Features added
....................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
,
Alcatel-Lucent - Proprietary
See notice on first page
xvii
Ruby 1.0 December 2000
• One or Two STM-1 or two STM-4 optical line interface
pairs (transmit/receive)
• Upto sixteen 2 Mbit/s interface ports - G.703 interface -
G.704/G.706 interface
• Remote and local software downloading
• General VC-11/VC-12 SNC/N protection or VC-3
SNC/N protection
• 1+1 MSP protection (STM-1 aggregate only) in terminal
applications
• Performance Monitoring
• E1 or DS1 or E3 or DS3 or X.21 loopbacks
• Cross-connect loopbacks
• Four Miscellaneous Discrete Inputs (MDI)
• Four Miscellaneous Discrete Outputs (MDO)
• Dual fiber pair working
• IP Tunneling in the DCC channels for the management
of elements (TCP/IP protocol)
• Space-efficient for simple and rapid installation within
street cabinets or in customer premises
• Supported by the user-friendly Integrated Transmission
Management (ITM) network management and element
management systems
• AC/DC or DC/DC converter
• Working in large temperature range
• Optional additional sixteen 1.5 Mbit/s ports
• Optional additional sixteen 2 Mbit/s ports
• Optional additional two 34 Mbit/s ports
• Optional additional two 45 Mbit/s ports
• Optional additional four 2 Mbit/s X.21 ports
• Optional additional four 10/100Base-T LAN interfaces
Topaz 2.0 July 2001
• Optional additional two optical STM-1 tributary signals
Pearl 2.2 July 2002
• Optional additional two electrical STM-1 tributary
signals
• Spanning tree protocol
Garnet 3.1 May 2003
• Rapid spanning tree protocol
Garnet 3.2 July 2003
• introduction of 1643 AMS
• introduction of Network Termination Unit (NTU)
• Optional additional twelve SHDSL interfaces
About this information product
...................................................................................................................................................................................................................................
xviii
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
,
Venus 4.0 September 2003
• X8PL option card
• LCAS functionality for VC-12 and VC-3
• AITS operation (DCC
m
)
• Transparent DCC
r
Earth 5.0 April 2004
• Support of SNMP management
• Advanced SFP data retrieve capability
• Enhanced VLAN tagging
• Enhanced Ethernet port provisioning
• Provisionable LSP size
Mars 6.1 March 2005
• Enhanced flow classification (Port, VID, UP) on E/FE
units
• QoS in IEEE 802.1Q & IEEE 802.1ad mode on E/FE
units, i.e. flow classification, rate control and traffic
class handling
• Oversubscription in IEEE mode
• SHDSL Performance Monitoring
• SHDSL enhancements
• Port Loopback alarming
• J0 support on STM-n lines
• E1 non-intrusive performance monitoring
• E1 PDH AIS
• 1643 AMS with integrated AC power supply
Uranus 7.1 November 2006
• Optional TransLAN card - X5IP, Remote Power Supply
support
• Ethernet PM counter enhancements
• PM counter for Congestion monitoring
• Round trip time/delay measurement
• Provisionable CBS
• Flow classification based on DA-MAC and
IP-TOS/DSCP
• SHDSL enhancements
Miranda 7.2 February 2007 The following features are implemented in this release:
• Alarm Severity Assignment Profile (ASAP)
• X5IP option card enhancements
• Outloops on Ethernet ports in repeater mode
• Performance Monitoring
• VC-4-4c cross connection
• Supported by the Lucent OMS Release 5.0.2 and
Wavestar
®
ITM-CIT - Release 18.0
About this information product
...................................................................................................................................................................................................................................
365-312-802R7.2
Issue 4, June 2007
,
Alcatel-Lucent - Proprietary
See notice on first page
xix
Safety information
This information product contains hazard statements for your safety. Hazard statements
are given at points where safety consequences to personnel, equipment, and operation
may exist. Failure to follow these statements may result in serious consequences.
Intended audience
This manual is intended for users who wish to install, configure and cable 1643 AM
and 1643 AMS units including all accessories.
This requires that the installation staff has a basic knowledge of SDH and Ethernet
technology. Working on the equipment described in this manual requires also special
training of the personnel.
How to use this information product
This manual is divided into the following sections with a brief description of the
contents of each major part/chapter/appendix:
About this document describes the purpose, intended audience, reason for reissue,
and organisation of this document. This section references related documentation and
explains how to order, make comments or recommend changes to this document.
Part I – Physical and power installation
• Chapter 1, Safety
This chapter provides all relevant information and safety guidelines to safeguard
against personal injury. Furthermore, this chapter may be useful to prevent material
damage to the equipment.
• Chapter 2, General information
This chapter provides all facts which must be known before the system can be
installed, such as environmental requirements, ITM-CIT requirements, EMC/ESD
information, etc.
• Chapter 3, Mechanical installation
This chapter provides all information needed to install 1643 AM and 1643 AMS
units.
• Chapter 4, System cabling
This chapter provides all tasks for a complete system cabling.
• Chapter 5, Powering
This chapter describes the system powering and some final tests which should be
performed to end the physical installation part.
Part II – NE provisioning and stand alone installation test
• Chapter 6, ITM-CIT installation and NE provisioning
This chapter describes the ITM-CIT and NE software installation and the initial NE
provisioning via ITM-CIT.
• Chapter 7, Stand alone test procedures
This chapter provides all tests which must be performed to verify the proper
working of the units/NEs.
About this information product
...................................................................................................................................................................................................................................
xx
Alcatel-Lucent - Proprietary
See notice on first page
365-312-802R7.2
Issue 4, June 2007
,
1/278