Datalogic WebSentinel™ PLUS Installation guide

Type
Installation guide

Datalogic WebSentinel™ PLUS is a server designed to work with the WebSentinel PLUS scan point monitoring system. It comes preloaded with software that allows it to connect to Datalogic scanning and dimensioning systems. The server has multiple ports for connecting to a static sorting/device network, a host network, a monitor, a mouse, and a keyboard. It also has USB 2.0 & 3.0 ports for connecting additional devices. The WebSentinel™ PLUS server can be configured to connect to a facility's Host network. It also allows for the creation of multiple user accounts with different levels of access.

Datalogic WebSentinel™ PLUS is a server designed to work with the WebSentinel PLUS scan point monitoring system. It comes preloaded with software that allows it to connect to Datalogic scanning and dimensioning systems. The server has multiple ports for connecting to a static sorting/device network, a host network, a monitor, a mouse, and a keyboard. It also has USB 2.0 & 3.0 ports for connecting additional devices. The WebSentinel™ PLUS server can be configured to connect to a facility's Host network. It also allows for the creation of multiple user accounts with different levels of access.

WebSentinel™ PLUS Server
Installation Manual
The WebSentinel PLUS Server is recommended by Datalogic for use with
WebSentinel PLUS scan point monitoring system. The WebSentinel PLUS
server comes with the software preloaded and ready to connect to
Datalogic scanning and dimensioning systems. This document provides
information for a successful mechanical installation. For complete
information on WebSentinel PLUS, see the WebSentinel PLUS User’s
Manual.
UNPACKING INSTRUCTIONS
Carefully unpack the server from its box, and retain the box and packing
material in case the server ever needs to be shipped back to Datalogic.
Make sure the box has the following contents:
WebSentinel PLUS Server PC with attached mounting brackets/
flanges
Power Supply
Power Cable
Mounting brackets (already attached)
GENERAL MOUNTING GUIDELINES
It is important that you follow these general precautions when installing,
setting up, operating, maintaining, troubleshooting, or replacing any
Datalogic products, parts or related equipment.
As you plan and install your WebSentinel PLUS Server, be sure to keep the
following guidelines in mind:
Determine the proper orientation and position the server. Mount
the server so connectors are accessible.
Leave adequate clearances (approximately 300 mm [12 inches])
for wiring around the server for cabling.
Route wires carefully to reduce or minimize electrical noise.
When power and communication wiring must cross, make their
intersection perpendicular.
Proper grounding limits the effects of noise due to Electro-
magnetic Interference (EMI). Make sure the mounting structure
and power access is properly grounded.
Figure 1: Mounting to Structure
MOUNTING DIMENSIONS
Figure 2: Mounting Dimensions
DATALOGIC WEBSENTINEL PLUS SERVER CONNECTIONS
Figure 3: Server Connections
1. Power – Power supply connection
2. Digital Video – Monitor connections (optional, see Digital to Analog
converter below)
3. LAN A – Connection to HOST Network
4. LAN B – Connection to Device Network
5. USB 2.0 & 3.0 – Mouse and Keyboard connection (optional, see
section 2.6 Accessories)
6. Power Switch
FIRST TIME STARTUP AND NETWORK CONFIGURATION
After the Datalogic server has been mounted, attach the power, monitor,
LAN 2 device network (and LAN 1 Host if used), keyboard, and mouse
cables as shown in section 2.5.1. The Datalogic WebSentinel PLUS server
uses a Linux operating system, which must be configured for your facility’s
static sorting/device network. If desired, the server can also configure to
connect to your facility’s Host network.
Use the following procedure to configure the network adapter settings.
1. Press the power switch to turn on the server. The Log In screen
appears.
2. Select remotemonitor from the drop-down list.
3. Enter the default password, asiroot, and click Log In. The Linux
desktop is displayed.
4. Click the start icon in the upper left corner of the desktop. A Linux
menu appears.
5. Select Settings from the right side of the menu box, and then select
Network Connections from the list on the left. The Network
Connections box opens.
6. Click Add. The Editing box opens.
7. Select the Ipv4 Settings tab.
8. Select Manual from the Method drop-down list.
IMPORTANT: The IP addresses entered must be
a static IP assignment. DO NOT USE DHCP
ADDRESS ASSIGNMENT for the sorting/device
network.
9. Click Add, and enter the Address (IP address), Netmask, and
Gateway in the fields provided. Contact the facility IT administrator for
the correct connection information.
10. Click Save.
11. If desired, add another connection for the facility Host network.
Mount the server to the
structure extrusion with
threaded screws
(920000080).
Mounin
g
Mountin
g
brackets
INITIAL ADMINISTRATOR LOGIN AND LICENSING
To Gain Access to WebSentinel PLUS:
1. Click the Firefox Web Browser icon on the desktop to open the
browser.
2. Enter the IP Address of the server (created in step 9 above) in the
browser address bar to access the WebSentinel PLUS Login window.
3. If the IP Address (URL) for the server does not match the default in the
WebSentinel PLUS software, an Access Denied window appears.
4. Click on the Server IP Address Config link. The Server IP Address
Config window opens.
5. Under IPAddress.properties, enter the server IP Address in the New
text field, and click Update IPAddress.properties.
6. Under Sites IP Address, select your site from the Update Site IP
Address drop-down list, enter the server IP Address in the text field,
and click Update IP Address in DB.
NOTE: The Global Master Database IP can be set
as localhost if the server is not in linked or Enterprise
mode. If it is, then that field must be set to the IP
Address of the WebSentinel PLUS server that serves
as the Master.
7. Click Reboot Server.
8. After the server reboots, click the Firefox Web Browser icon on the
desktop to open the browser.
9. Again enter the IP Address of the server in the browser address bar.
The WebSentinel PLUS Login window opens.
10. The system administrator can log into WebSentinel PLUS using the
default User ID Admin and Password Admin.
Upon initial log in, the License Management window will appear.
11. Obtain a License Key by sending an email to
[email protected], and include the following
information:
Name of the company or reference person to which the product
will be licensed.
Product Key displayed on the License Management window.
Product serial number found on the software package cover.
You will then receive a email reply with the License Key.
12. When you receive the email with the new License Key, copy the key
and paste it in the License Key field of the License Management
window.
13. Click Update License Key.
It is recommended that the system administrator immediately change
the Administrative password and set up system users (see the
WebSentinel PLUS User’s Manual).
System users can then obtain a User ID and Password from the system
administrator.
WEBSENTINEL PLUS SERVER ACCESSORIES
There are a few accessories that can be added to the Datalogic
WebSentinel PLUS server, including a monitor, keyboard/mouse, and
cabling.
ACCESSORY LIST PART NUMBER
KIT, MONITOR/KEYBRD/BRKT/USB HUB 93ACC0126
CBL,EXT,10FT,USB MOUSE/KEYBOARD 93ACC0108
ENC-3610 ENCLOSURE DIM CONTROLLER 93ACC0115
CABLE,NETWORK,2M,CAT6,DOUBLE-
SHIELDED,BLUE,ROHS EU 1000068706
CABLE,NETWORK,5M,CAT6,DOUBLE-
SHIELDED,BLUE,ROHS EU 1000068369
CABLE,NETWORK,10M,CAT6,DOUBLE-
SHIELDED,BLUE,ROHS EU 1000068707
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support through its
website. Log on to www.datalogic.com and click on the SUPPORT link
which gives you access to:
Downloads by selecting your product model from the dropdown list in the
Search by Product field for specific Data Sheets, Manuals, Software &
Utilities, and Drawings;
Repair Program for On-Line Return Material Authorizations (RMAs) plus
Repair Center contact information;
Customer Service containing details about Maintenance Agreements;
Technical Support through email or phone.
COMPLIANCE
CE COMPLIANCE
CE marking states the compliance of the product with essential
requirements listed in the applicable European directive. Since the
directives and applicable standards are subject to continuous updates, and
since Datalogic promptly adopts these updates, therefore the EU
declaration of conformity is a living document. The EU declaration of
conformity is available for competent authorities and customers through
Datalogic commercial reference contacts. Since April 20th, 2016 the main
European directives applicable to Datalogic products require inclusion of an
adequate analysis and assessment of the risk(s). This evaluation was
carried out in relation to the applicable points of the standards listed in the
Declaration of Conformity. Datalogic products are mainly designed for
integration purposes into more complex systems. For this reason it is under
the responsibility of the system integrator to do a new risk assessment
regarding the final installation.
WARNING: This is a Class A product. In a domestic environment
this product may cause radio interference in which case the user
may be required to take adequate measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written
approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his/her
own expense.
EAC COMPLIANCE
Customs Union:
The CU Conformity certification has been achieved; this allows the Product
to bear the Eurasian mark of conformity.
LEGAL NOTICE
© 2016-2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS
RESERVED. Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose,
without the express written permission of Datalogic S.p.A. and/or its
affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic
S.p.A. in many countries, including the U.S.A. and the E.U.
WebSetntinel PLUS is a trademark of Datalogic S.p.A. and/or its affiliates.
All other trademarks and brands are property of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions
contained herein, nor for incidental or consequential damages resulting
from the use of this material.
821004272 Rev. B
  • Page 1 1
  • Page 2 2

Datalogic WebSentinel™ PLUS Installation guide

Type
Installation guide

Datalogic WebSentinel™ PLUS is a server designed to work with the WebSentinel PLUS scan point monitoring system. It comes preloaded with software that allows it to connect to Datalogic scanning and dimensioning systems. The server has multiple ports for connecting to a static sorting/device network, a host network, a monitor, a mouse, and a keyboard. It also has USB 2.0 & 3.0 ports for connecting additional devices. The WebSentinel™ PLUS server can be configured to connect to a facility's Host network. It also allows for the creation of multiple user accounts with different levels of access.