Datalogic WebSentinel Quick start guide

Type
Quick start guide

Datalogic WebSentinel is an advanced monitor and information collection application that serves as a supervisory software solution for monitoring operational activities of reading devices via a web browser-based interface. It provides visibility to enterprise-controlled automated systems, offering a high-level view of site, facility, scan point, and device performance, as well as package information.

Datalogic WebSentinel is an advanced monitor and information collection application that serves as a supervisory software solution for monitoring operational activities of reading devices via a web browser-based interface. It provides visibility to enterprise-controlled automated systems, offering a high-level view of site, facility, scan point, and device performance, as well as package information.

821012810 (Rev. A) August 2023
WebSentinel, WebSentinel PLUS and WebSentinel PLUS
Investigator are trademarks of Datalogic S.p.A. and/ or its
affiliates. All other brand and product names may be trade-
marks of their respective owners.
Patents
See www.patents.datalogic.com for patent list.
This product is covered by one or more of the following
patents: Utility patents: EP2517148B1, EP2649555B1,
EP3016028B1, US10762405, US11314959, US8888003,
US8915443, US9361503, US9798948, ZL200980163411.X,
ZL201080071124.9
Datalogic S.r.l.
Via San Vitalino 13
40012 Calderara di Reno (BO)
Italy
Tel. +39 051 3147011
Fax +39 051 3147205
©2023 Datalogic S.p.A. and/or its affiliates
All rights reserved. Without limiting the rights under copyri-
ght, no part of this documentation may be reproduced, sto-
red in or introduced into a retrieval system, or transmitted
in any form or by any means, or for any purpose, without
the express written permission of Datalogic S.p.A. and/or its
affiliates.
Owners of Datalogic products are hereby granted a
non-exclusive, revocable license to reproduce and transmit
this documentation for the purchaser's own internal busi-
ness purposes. Purchaser shall not remove or alter any pro-
prietary notices, including copyright notices, contained in this
documentation and shall ensure that all notices appear on
any reproductions of the documentation.
Electronic versions of this document may be downloaded
from the Datalogic website (www.datalogic.com). If you visit
our website and would like to make comments or sugge-
stions about this or other Datalogic publications, please let
us know via the "Contact" page.
Disclaimer
Datalogic has taken reasonable measures to provide infor-
mation in this manual that is complete and accurate, howe-
ver, Datalogic shall not be liable for technical or editorial
errors or omissions contained herein, nor for incidental or
consequential damages resulting from the use of this mate-
rial. Datalogic reserves the right to change any specification
at any time without prior notice.
Trademarks
Datalogic and the Datalogic logo are registered trademarks
of Datalogic S.p.A. in many countries, including the U.S.A.
and the E.U.
Support Through the Website
Datalogic provides several services as well as techni-
cal support through its website.
Log on to www.datalogic.com.
For quick access, from the home page click on the
search icon , and type in the name of the pro-
duct you’re looking for. This allows you access to
download Data Sheets, Manuals, Soware & Utilities,
and Drawings.
Hover over the Support & Service menu for access to
Services and Technical Support.
WebSentinel PLUS
Premium
QUICK START GUIDE
Installation
©2023 Datalogic S.p.A. and/or its affiliates
• All rights reserved • Without limiting the rights
under copyright, no part of this documentation
may be reproduced, stored in or introduced into
a retrieval system, or transmitted in any form or
by any means, or for any purpose, without the
express written permission of Datalogic S.p.A.
and/or its affiliates • Datalogic and the Datalogic
logo are registered trademarks of Datalogic S.p.A.
in many countries, including the U.S. and the E.U.
www.datalogic.com
WEBSENTINEL PLUS
OVERVIEW
WebSentinel PLUS is an advanced monitor and infor-
mation collection application. It serves as a super-
visory soware solution for monitoring operational
activities of reading devices via a single web brow-
ser-based interface. It provides visibility to enterprise
controlled automated systems at a high level view of
Site, Facility, Scan Point and Device performance and
Package information.
Investigator
Investigator is a soware add-on to Datalogic’s Web-
Sentinel PLUS tool. It provides no read classification
and bar code grading for each barcode read during
normal operations. No Read classification post pro-
cessing saves images of No Reads and sorts them
into categories to determine No Read root causes.
Bar code grading estimates trends in printing qua-
lity to determine decreasing quality before labels
become no reads.
PREMIUM Ready-to-Use Server
Both WebSentinel PLUS and Investigator are already
installed on this Linux based server. The Premium
Server provides the capacity to run WebSentinel
PLUS and Investigator for optimum performance.
It provides more RAM and Internal memory as well
as faster processing. A removalbe 1 TB drive is also
provided.
Documentation for guiding you through the complete
installation process for WebSentinel PLUS and Inve-
stigator can be found in the DOCUMENTATION folder
on your PREIMUM server.
To access the folder you must first connect power, a
monitor, mouse and keyboard. To complete this pro-
cess, follow the steps on the back of this Quick Start
Guide.
WebSentinel PLUS Product Reference Guide
y See Chapter 2: Installing WebSentinel PLUS
Ready to Use Server
y See Chapter 5: Connecting Datalogic Devices to
WebSentinel PLUS
Investigator Product Reference Guide
GETTING STARTED WITH THE
PREMIUM SERVER
Carefully unpack the server from its box, and retain
the box and packing material in case the server ever
needs to be shipped back to Datalogic. Make sure the
box has the following contents:
y WebSentinel PLUS Server PC
y Power Supply
y Power Cable
y Remove all the components from their packa-
ging; check their integrity and compare them
with the packing documents.
WIRING TO THE SERVER
The important server connections used by WebSen-
tinel PLUS to access DOCUMENTATION are shown:
1. Make sure the Power Switch is ON aer power is
applied.
2. Connect the Mouse and Keyboard to one of the
available USB ports
3. Connect the Monitor to the (DP) Display Port
4. Connect the Power Cord to WebSentinel PLUS Ter-
minal Block
5. Connect the Power Cord to the Power supply
6. Connect the Monitor and Server to Power
!
"
#
$
%
&
ab $$
CONNECTING THE POWER CORD
The Power connector for the WebSentinel PLUS Premium Terminal is a Termina Block. Flying
leads need to be connected to the Power Connector Terminal Block
4a .White wire needs to be inserted into the third pin portion of the terminal block
4b. Brown wire needs to be inserted into the first pin portion of the terminal block
4c. Secure the terminal block to the server using the attached screws
c
$c
$
  • Page 1 1
  • Page 2 2

Datalogic WebSentinel Quick start guide

Type
Quick start guide

Datalogic WebSentinel is an advanced monitor and information collection application that serves as a supervisory software solution for monitoring operational activities of reading devices via a web browser-based interface. It provides visibility to enterprise-controlled automated systems, offering a high-level view of site, facility, scan point, and device performance, as well as package information.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI