22. Open Windows Explorer and identify the USB Flash Drive. Right click
on the drive name and select Eject from the drop-down list. A Safe To
Remove Hardware message bubble will appear.
23. Remove the USB Flash Drive and reboot the server.
POST INSTALLATION BACKGROUND CONFIGURATION
After WebSentinel PLUS has been installed on the server computer, there
are a few system settings that need to be adjusted for proper function.
Add MariaDB executables to PATH
1. Click the Windows Start icon, right click on Computer, and select
Properties.
2. From the Windows System window, click Advanced System
Settings. The System Properties window opens.
3. Click Environment Variables. The Environment Variables window
opens.
4. Select Path under System variables, and click Edit. The Edit
System Variables box pops up.
5. Open Windows Explorer and navigate to C:\Program File…\MariaDB
5.5\bin. Highlight the file path, and press CTRL- C to copy it.
6. Return to the Edit System Variables box. In the Variable value text
field, add a semicolon to the end of any text already in the field, and
then paste the path information that was copied in the previous step
after the semicolon, by pressing CTRL-V.
7. Click OK. Then continue clicking OK to close the open system
windows.
Configure the Network Adapter
1. From the desktop (Windows 7 or Windows 8), click the Start button,
and then select Control Panel.
2. Enter adapter in the search box, and then from the results, under
Network and Sharing Center, click View network connections.
3. Right-click sorting network Connection (you must know the name of
the connection for your system), and then select Properties.
4. Select the Networking tab. Select Internet Protocol Version 4
(TCP/IPv4), and then click Properties.
5. Select the Use the following IP address option button.
6. In the IP address field, type the first 3 octets of the actual IP address
of the sorting network (this may be the device network or image
network. If you don’t know the IP address, contact the system IT
administrator.)
7. For the last octet, type a number that differs from the last octet in the
sorting network’s IP address. The actual number used is not important
as long as it does not match that of the sorting network.
Example: If the sorting network’s IP Address is 192.168.0.145, set
your server’s IP Address to 192.168.0.146.
8. In the Subnet mask field, type 255.255.255.0
9. The Default gateway is empty.
10. Click OK.
Set Up the FTP Server
1. Open FileZilla by double clicking the desktop icon.
2. At the Connect to Server window, click OK.
3. Select Edit > Users from menu bar. The Users window opens.
4. Under Page, select General, and under Users, click Add.
5. Enter the user account name ftpuser.
6. Select the Password check box, and enter the password asiroot.
7. Under Page, select Shared Folders and click Add.
8. Browse for folder C:\RemoteMonitor\images, and click OK.
9. Select all of the Files and Directories check boxes to grant all
read/write permissions.
10. Click Set as home directory.
NOTE: The shared folder added and Set as home
directory is the directory where camera images will be
stored.
11. Repeat the steps above to create another user with the username
anonymous and a password anonymous.
After WebSentinel PLUS and the other necessary components have been
installed and configured, connect to WebSentinel PLUS through a browser
to configure your facility and scan point connections (see the WebSentinel
PLUS User’s Manual, Chapter 4).
WebSentinel PLUS and Windows Operating System Firewall
An administrator level user may need to configure the machine's firewall
rules to allow WebSentinel PLUS applications to operate. This can be done
after installation by registering these applications as an allowed program in
the built-in firewall's allowed programs list. The firewall modifications can be
made from the Windows Control Panel and Windows Firewall, but
accessing these controls will differ depending on the operating system
version being used. If you cannot access the controls or if a different firewall
is used, contact your IT department. The firewall should be modified to
allow the following programs and ports.
Private and public network selections for the applications must be allowed.
If an application is not listed, add the executable file and directory path.
INITIAL ADMINISTRATOR LOGIN AND LICENSING
To Gain Access to WebSentinel PLUS:
1. Open a browser and enter the server IP address in the address bar.
Use the server IP Address created earlier under Configure the
Network Adapter.
2. If the IP Address (URL) for the server does not match the default in the
WebSentinel PLUS software, an Access Denied window appears.
3. Click on the Server IP Address Config link in the Access Denied
window. The Server IP Address Config window opens (see the
WebSentinel PLUS User’s Manual).
4. Under IPAddress.properties on the Server IP Address Config
window, enter the server’s IP Address in the New text field, and click
Update IPAddress.properties.
5. Under Sites IP Address, select your site from the Update Site IP
Address drop-down list, enter the server IP Address in the text field,
and click Update IP Address in DB.
NOTE: The Global Master Database IP on the Server
IP Address Config window can be set as localhost if
the server is not in linked or Enterprise mode. If it is,
then that field must be set to the IP Address of the
WebSentinel PLUS server that serves as the Master.
6. Click Reboot Server.
7. After the server reboots, open a browser and enter the WebSentinel
PLUS server address in the address bar (see step 1 above). The
WebSentinel PLUS Login window opens.
8. The system administrator can log into WebSentinel PLUS using the
default User ID Admin and Password Admin.
Upon initial log in, click Generate Product Key. The License
Management window appears.
9. Obtain a License Key by sending an email to
swlicense.automation@datalogic.com, and include the following
information: Name of the company or reference person to which the
product will be licensed; Product Key displayed on the License
Management window; Product serial number found on the software
package cover.
You will then receive a email reply with the new License Key.
10. When you receive the email with the new License Key, copy the key
and paste it in the License Key field of the License Management
window.
11. Click Update License Key.
12. Log in again.
It is recommended that the system administrator immediately change the
Administrative password, and set up system users (see the WebSentinel
PLUS User’s Manual). System users can then obtain a User ID and
Password from the system administrator.
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support through its
website. Log on to www.datalogic.com and click on the PRODUCT >
UNATTENDED SCANNING SYSTEMS > SOFTWARE category link. From
this page you can select the software you are looking for and will be
provided access to the following downloads including Data Sheets,
Manuals, Software & Utilities, and Drawings: Repair Program for On-Line
Return Material Authorizations (RMAs) plus Repair Center contact
information; Service Program containing details about Maintenance
Agreements; Technical Support through email or phone.
LEGAL NOTICE
© 2016-2017 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED.
Without limiting the rights under copyright, no part of this documentation may be
reproduced, stored in or introduced into a retrieval system, or transmitted in any form
or by any means, or for any purpose, without the express written permission of
Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in
many countries, including the U.S.A. and the E.U.
WebSetntinel PLUS is a trademark of Datalogic S.p.A. and/or its affiliates. All other
trademarks and brands are property of their respective owners.
Datalogic shall not be liable for technical or editorial errors or omissions contained
herein, nor for incidental or consequential damages resulting from the use of this
material. 821004262 Rev. B