13.2.12 WIMA
1
These installation instructions apply to the models:
Identification plate
Open the appliance door. The identification plate is located on the left trim panel (see
illustration).
Connection plate
The connection plate is located on the connection cable.
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
Connection cable
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
Oven
Combi-steam cooker:
43A, 49A, 21020, 21026
59A
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.
To ensure good ventilation, the niche in which the appliance stands must have a supply air opening of at least 25 cm
2
.
This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual
current device (RCD) having a rated residual operating current not exceeding 30 mA.
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
230V~ 16A
400V2N~ 10A
L2 schwarz, black,
noir, nero
L1 braun, brown,
brun, marrone
N blau, blue, bleu, blu
gelb/grün,
yellow/green,
jaune/vert,
giallo/verde
N blau, blue, bleu, blu
gelb/grün,
yellow/green,
jaune/vert,
giallo/verde
L1 braun + schwarz,
brown + black,
brun + noir,
marrone + nero
Installation instructions
Oven / Combi-steam cooker
Construction type 60-450
J43A.113-1
13.2.12 WIMA
2
Installing
1. Place appliance in front of the niche and connect connection cable in accordance with connection plate.
2. Carefully slide appliance into the niche until it is flush with the front of the cabinets, ensuring that the mains cable is not pinched.
3. Open appliance door and fasten the sides from the front with the 4 enclosed screws S.
Installation combinations
Installation
It is not possible to install the appliance above an extractor oven because of the extraction pipes that lead upwards.
If a second appliance is installed in the same niche (above or below), use bracket set 60 W to support the upper appliance.
Above oven Below oven Above warming drawer
=
=
50
346
(567)
454
596
548
~85˚
min. 550
600
560–568
20
~45
548
S
S
X
450
Detail X
450
Niche
454
Appliance
W
450600
1050
50
560–568
min. 550
W
594456
1050
min. 550
50
560–568
W
450144
594
50
560–568
min. 550
  • Page 1 1
  • Page 2 2

V-ZUG 59A Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI