AERF SRM L User manual

Type
User manual
220V
POWER SUPPLY
RELAY 1 OUTPUT RELAY 2 OUTPUT
C1 Common relay 1
NC1 Normally closed
NO1 Normally open
C1 Common relay 2
NC2 Normally closed
NO2 Normally open
1 2
RELAY
COMMON
4 5 6
RELAY
COMMON
7 8 9
1. APPLICATIONS
2. CONNECTIONS
- Smart control product range, intelligent code, safe, reliable and cannot be copied.
- Receiver for any automatic system.
- Multy function selection.
- Option to use Smart transmitters with Hopping Code or fixed code.
3. OPTIONS
HOPPING CODE /
FIXED CODE
RELAY 1 FLIP-FLOP /
RELAY 1 PULSE
RADIO
PROGRAMMING
OPTION FUNCTION
RELAYS /
PREDETERMINED
FUNCTIONS
- Assigns each relays according to the order of memorization of the first two codes. The first
transmitter button pressed is assigned to the 1st relay. The second button pressed is
assigned to the second relay.
- Allows the transmitters radio programming and transmitters manual programming. (see
points 4. y 4.1)
- Allows only the transmitter manual programming. (see point 4.)
- Relay 1 flip-flop mode. Activated Deactivated Activated …, according to signal.
-Relay 1 Pulse mode. Relay maintains activated during signal reception (Deadman).
- Hopping code.
- Fixed code.
- Default relays assignment:
Function (button) 1, first relay. Function (button) 2, second relay.
1
2
3
4
ON
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
GB
SRM H Instruction Manual
1 - 2
SRM H
20/05/14
RELAY 1 OUTPUT RELAY 2 OUTPUT
1 2
1 2
POWER SUPPLY
24V
AC/DC
AC/DC
12V
RELAY
COMÚN
3 4 5
RELAY
COMÚN
6 7 8
12/24
AC/DC
SRM L Instruction Manual
C1 Common relay 1
NC1 Normally closed
NO1 Normally open
C1 Common relay 2
NC2 Normally closed
NO2 Normally open
SRM L
4.1 TRANSMITTER RADIO PROGRAMMING
4.2 MEMORY RESET
4. TRANSMITTER MANUAL PROGRAMMATION
GB
PROG.
1.5s
PROG.
1 X BIP 1 X BIP
RELEASE
PRESS BUTTON
PROG. EMIS
10s
SAVE & EXIT
2 X BIPS
WAIT
PRESS BUTTON
ON
LED ON
OFF
LED OFF
1 X BIP1 X BIP
MUST HAVE A
TRANSMITTER RECORDED
IN A RECEIVER
1.5s
10s
PUSH
BUTTON
RELEASE
WAIT
PUSH A
SPECIAL
FUNCTION
A
A
B
A
SAVE & EXIT2 X BIPS
ON
LED ON
OFF
LED OFF
1 X BIP
SAVE & EXIT
2 X BIPS
PROG.
1.5s
PULSAR
PROG.
10s
PROG.
5s
WAIT
RELEASE
# BIPS
KEEP IT
PRESSED
ON
LED ON
OFF
LED OFF
WARNING!!
- Equipment installation and start-up, can only be executed
by qualified personal.
CE DECLARATION OF CONFORMITY
Aplicaciones electrónicas y de Radiofrecuencia S.L Pol. Sot dels Pradals C/ Sot dels pradals, 4 08500
Vic (Barcelona) B61840732 DECLARES, under her own responsibility that product It is designed and
manufactured in accordance with the directives LV 2006/95/CE of Low Voltage, EMC 2004/108/CE of
Electromagnetic Compatibility , 2006/42/CE Machines directive and is designed to control doors in
accordance with standard EN13241-1 (2004) and complies with the requirements of the R&TTE
99/05/CE European parliament directive of March 9th 1999. This directive was transposed to the
Spanish legislation by means of Real Decree 1890/2000 in November 20th of 2000, directive 1999/5/CE
spectrum radio electric protection, electromagnetic compatibility directive 2004/108/CE. For more
information visit the website www.aerf.eu
Power 230V AC +/- 10%
Max. Power consumption 0.5A (230v) 65mA(12V) 80mA(24V)
Outputs:
Fixed outputs 2 Relay 1A/30V
Available codes 2.097.152.281 Millions
Encryption technology Hopping code
Key Encryption 64 bits
Detection of errors during transmission 2 CRC bits
Error detection 31/255/1000 different codes
Number of codes Self learning
Fuction selection:
1 relay Memorizes in function of the code
2 relays or more Predeterminated function or program
Latch relays Position 1 programable
Frecuency 433.92MHz OR 868,35MHz
Certificates ETS300-220/ETS300-683
Spurious emissions < -57dBm
Sensitivity < -104dBm
Range 60m
Access control YES
Temperature 0 to 70º
Antenna 17cm / 8,5cm
TECHNICAL SPECIFICATIONS
2 - 2
SRM H
20/05/14
65mA(12V) 80mA(24V)
12/24 V AC +/- 10%
SRM L