PA mounting
PA mounting
To remove PCB, push
clip forward
To remove Battery,
lift up
Fitted with
1 x ICR123
Rechargeable
750mA Battery
+ -
Power in 5V to 13V DC
Replace back tamper
plate if removed for
drilling holes through
Drill through appropriate pilot
holes in rear enclosure and mount
to wall
Mount Holes
mount with
2 x 1 inch No.8
security screws
2. Flat mounting
1. Corner mounting 3. Edge mounting
Base mounting diagrams.
Enrolling on a GSDi intrusion system
1.
2.
3.
4.
5.
6.
7.
8.
9.
On the system start enrolling: see GSDi installation manual for details.
Remove the front cover from GSDi-RF-RPT.
Remove battery Tab
Connect power (5 - 13V) to the Terminals, ie.:i70 Panel Aux Power
Press and hold the front tamper.
If removing PCB from the base, ensure that the back tamper is closed before
closing front tamper.
Wait about 5 seconds.
When the LED on the front lights, release the tamper switch.
- The sensor flashes the LED to indicate it is searching for the system.
- When it finds the system the Panel will display a message.
At the Panel click Finish or Test Device
- Test Device; Signal Range < Next > Status (Open /Tamper) < Next > Device
Name < > Area < Next > Device Setting < Next > Finish
Replace front cover on GSDi-RF-RPT and secure it with the fixing screw.
Note: Any device using the Repeater will show Signal Boostings.
N.B. USE RECHARGABLE BATTERY ONLY.
RPT opening
2 Operation Instructions 3
Installation Diagrams