H3C S7500E-XS Series Installation guide

Category
Network switches
Type
Installation guide
H3C S7500E-XS Switch Series
Installation Guide
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Software version: 6W100-20150730
Copyright © 2015, Hangzhou H3C Technologies Co., Ltd. and its licensors
All rights reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior
written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , H3CS, H3CIE, H3CNE, Aolynk, , H
3
Care, , IRF, NetPilot, Netflow,
SecEngine, SecPath, SecCenter, SecBlade, Comware, ITCMM and HUASAN are trademarks of
Hangzhou H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Environmental protection
This product has been designed to comply with the environmental protection requirements. The storage,
use, and disposal of this product must meet the applicable national laws and regulations.
Preface
H3C S7500E-XS Switch Series Installation Guide describes the appearance, installation, power-on,
maintenance, and troubleshooting of the S7500E-XS Switch Series.
This preface includes:
• Audience.
• Conventions.
• About the H3C S7500E-XS documentation set
• Obtaining documentation.
• Technical support.
• Documentation feedback.
Audience
This documentation is intended for:
• Network planners.
• Field technical support and servicing engineers.
• Network administrators working with the S7500E-XS series.
Conventions
This section describes the conventions used in this documentation set.
Command conventions
Convention Descri
p
tion
Boldface Bold text represents commands and keywords that you enter literally as shown.
Italic Italic text represents arguments that you replace with actual values.
[ ] Square brackets enclose syntax choices (keywords or arguments) that are optional.
{ x | y | ... }
Braces enclose a set of required syntax choices separated by vertical bars, from which
you select one.
[ x | y | ... ]
Square brackets enclose a set of optional syntax choices separated by vertical bars, from
which you select one or none.
{ x | y | ... } *
Asterisk marked braces enclose a set of required syntax choices separated by vertical
bars, from which you select at least one.
[ x | y | ... ] *
Asterisk marked square brackets enclose optional syntax choices separated by vertical
bars, from which you select one choice, multiple choices, or none.
&<1-n>
The argument or keyword and argument combination before the ampersand (&) sign can
be entered 1 to n times.
# A line that starts with a pound (#) sign is comments.
GUI conventions
Convention Descri
p
tion
Boldface
Window names, button names, field names, and menu items are in Boldface. For
example, the New User window appears; click OK.
> Multi-level menus are separated by angle brackets. For example, File > Create > Folder.
Symbols
Convention Descri
p
tion
WARNING
An alert that calls attention to important information that if not understood or followed can
result in personal injury.
CAUTION
An alert that calls attention to important information that if not understood or followed can
result in data loss, data corruption, or damage to hardware or software.
IMPORTANT
An alert that calls attention to essential information.
NOTE
An alert that contains additional or supplementary information.
TIP
An alert that provides helpful information.
Network topology icons
Represents a generic network device, such as a router, switch, or firewall.
Represents a routing-capable device, such as a router or Layer 3 switch.
Represents a generic switch, such as a Layer 2 or Layer 3 switch, or a router that supports
Layer 2 forwarding and other Layer 2 features.
Represents an access controller, a unified wired-WLAN module, or the access controller
engine on a unified wired-WLAN switch.
Represents an access point.
Represents a mesh access point.
Represents omnidirectional signals.
Represents directional signals.
Represents a security product, such as a firewall, UTM, multiservice security gateway, or
load-balancing device.
Represents a security card, such as a firewall, load-balancing, NetStream, SSL VPN, IPS,
or ACG card.
Port numbering in examples
The port numbers in this document are for illustration only and might be unavailable on your device.




About the H3C S7500E-XS documentation set
The H3C S7500E-XS documentation set includes:
Cate
g
or
y
Documents
Pur
p
oses
Hardware specifications
and installation
Compliance and safety
manual
Provides regulatory information and the safety
instructions that must be followed during installation.
Installation quick start Provides basic installation instructions.
Installation guide
Provides a complete guide to hardware installation
and hardware specifications.
Interface cards user
manual
Describes the appearance, specifications, and
installation and removal of interface cards.
Software configuration
Configuration guides
Describe software features and configuration
procedures.
Command references
Provide a quick reference to all available
commands.
Obtaining documentation
Access the most up-to-date H3C product documentation on the World Wide Web
at http://www.h3c.com
.
Click the following links to obtain different categories of product documentation:
[Technical Documents]
—Provides hardware installation, software upgrading, and software feature
configuration and maintenance documentation.
[Products & Solutions]
—Provides information about products and technologies, as well as solutions.
[Software Download]
—Provides the documentation released with the software version.
Technical support
http://www.h3c.com
Documentation feedback
You can e-mail your comments about product documentation to info@h3c.com.
We appreciate your comments.
i
Contents
Preparing for installation ············································································································································· 1
Safety recommendations ·················································································································································· 1
Examining the installation site ········································································································································· 1
Temperature/humidity ············································································································································· 2
Cleanliness ································································································································································ 2
EMI ············································································································································································· 2
Laser safety ································································································································································ 3
Installation tools ································································································································································· 3
Installing the switch ······················································································································································ 4
Installing the switch in a 19-inch rack ····························································································································· 5
Installation accessories ············································································································································ 5
Rack-mounting procedures at a glance ·················································································································· 6
Attaching the mounting brackets, chassis rails, and grounding cable to the chassis ······································· 7
Attaching the slide rails to the rack ····················································································································· 11
Mounting the switch in the rack ··························································································································· 12
Grounding the switch ···················································································································································· 14
Grounding the switch with a grounding strip ····································································································· 15
Grounding the switch by using the AC power cord ·························································································· 16
Installing/removing a fan tray ······································································································································ 16
Installing a fan tray ··············································································································································· 17
Removing a fan tray ·············································································································································· 18
Installing/removing a power module ··························································································································· 19
Installing a power module ···································································································································· 20
Removing a power module ·································································································································· 21
Connecting the power cord ·········································································································································· 22
Connecting the LSVM1AC650 power module ·································································································· 22
Connecting the LSVM1DC650 power module ·································································································· 23
Installing/Removing an interface card ················································································································ 23
Verifying the installation ················································································································································ 25
Accessing the switch for the first time ······················································································································· 26
Setting up the configuration environment ···················································································································· 26
Connecting the console cable ······································································································································ 26
Serial console cable ·············································································································································· 26
USB mini console cable ········································································································································ 27
Connection procedure ·········································································································································· 27
Setting terminal parameters ·········································································································································· 29
Powering on the switch·················································································································································· 30
Setting up an IRF fabric ············································································································································· 31
IRF fabric setup flowchart ·············································································································································· 31
Planning IRF fabric setup ··············································································································································· 32
Planning IRF fabric size and the installation site ································································································ 32
Identifying the master switch and planning IRF member IDs ············································································ 32
Planning IRF topology and connections ·············································································································· 33
Identifying physical IRF ports on the member switches ····················································································· 34
Planning the cabling scheme ······························································································································· 34
Configuring basic IRF settings ······································································································································· 35
Connecting the physical IRF ports ································································································································ 36
ii
Accessing the IRF fabric to verify the configuration ··································································································· 36
Maintenance and troubleshooting ···························································································································· 37
Power module failure ····················································································································································· 37
Fan tray failure ······························································································································································· 37
Configuration terminal problems ·································································································································· 38
No display on the configuration terminal ··········································································································· 38
Garbled display on the configuration terminal ·································································································· 38
Appendix A Chassis views and technical specifications ························································································ 39
Chassis views ································································································································································· 39
S7502E-XS ····························································································································································· 39
S7504E-XS ····························································································································································· 40
Technical specifications ················································································································································· 41
Appendix B FRUs and compatibility matrixes ·········································································································· 43
Power modules ······························································································································································· 43
Fan trays ·········································································································································································· 44
Interface cards ································································································································································ 44
Appendix C Ports and LEDs ······································································································································ 46
Ports ················································································································································································· 46
Console port ·························································································································································· 46
Management Ethernet port ··································································································································· 46
USB port ································································································································································· 47
SFP+ port ································································································································································ 47
QSFP+ port ···························································································································································· 49
1/10GBase-T autosensing Ethernet port ············································································································ 50
LEDs ················································································································································································· 51
System status LED··················································································································································· 51
SFP+ port LED ························································································································································ 51
QSFP+ port LED ····················································································································································· 52
Management Ethernet port LEDs ·························································································································· 52
1/10GBase-T autosensing Ethernet port LEDs ··································································································· 53
Power status LED ···················································································································································· 53
Fan tray alarm LEDs ·············································································································································· 53
Appendix D Cooling system ······································································································································ 55
S7502E-XS cooling system············································································································································ 55
S7504E-XS cooling system············································································································································ 55
Index ··········································································································································································· 57
1
Preparing for installation
The H3C S7500E-XS Switch Series includes the following models:
• S7502E-XS.
• S7504E-XS.
Safety recommendations
To avoid any equipment damage or bodily injury caused by incorrect use, read the following safety
recommendations before installation. Note that the recommendations do not cover every possible
hazardous condition.
• Before cleaning the switch, remove all power cords from the switch. Do not clean the switch with wet
cloth or liquid.
• Do not place the switch near water or in a damp environment. Prevent water or moisture from
entering the switch chassis.
• Do not place the switch on an unstable case or desk. The switch might be severely damaged in case
of a fall.
• Ensure good ventilation of the equipment room and keep the air inlet and outlet vents of the switch
free of obstruction.
• Connect the yellow-green protection grounding cable before power-on.
• Make sure the operating voltage is in the required range.
• To avoid electrical shocks, do not open the chassis while the switch is operating or when the switch
is just powered off.
• When replacing FRUs, including power modules, fan trays, and interface cards, wear an ESD wrist
strap to avoid damaging the units.
Examining the installation site
The switch must be used indoors.
Mount your switch in a rack and verify the following items:
• Adequate clearance is reserved at the air inlet and outlet vents for ventilation.
• The rack has a good ventilation system.
• Identify the hot aisle and cold aisle at the installation site, and make sure ambient air flows into the
switch from the cold aisle and exhausts to the hot aisle.
• Identify the airflow designs of neighboring devices, and prevent hot air flowing out of the bottom
device from entering the top device.
• The rack is sturdy enough to support the switch and its accessories.
• The rack is reliably grounded.
To ensure correct operation and long service life of your switch, install it in an environment that meets the
requirements described in the following subsections.
2
Temperature/humidity
Maintain appropriate temperature and humidity in the equipment room.
• Lasting high relative humidity can cause poor insulation, electricity creepage, mechanical property
change of materials, and metal corrosion.
• Lasting low relative humidity can cause washer contraction and ESD and cause problems including
loose screws and circuit failure.
• High temperature can accelerate the aging of insulation materials and significantly lower the
reliability and lifespan of the switch.
For the temperature and humidity requirements of different switch models, see "Appendix A Chassis
v
iews and technical specifications."
Cleanliness
Dust buildup on the chassis might result in electrostatic adsorption, which causes poor contact of metal
components and contact points, especially when indoor relative humidity is low. In the worst case,
electrostatic adsorption can cause communication failure.
Table 1 Dust concentration limit in the equipment room
Substance Concentration limit (particles/m³)
Dust
≤ 3 x 10
4
(no visible dust on the tabletop over three days)
NOTE:
Dust diameter ≥ 5 μm
The equipment room must also meet strict limits on salts, acids, and sulfides to eliminate corrosion and
premature aging of components, as shown in Table 2.
Table 2 Harmful gas li
mits in the equipment room
Gas Maximum concentration (mg/m
3
)
SO
2
0.2
H
2
S 0.006
NH
3
0.05
Cl
2
0.01
EMI
All electromagnetic interference (EMI) sources, from outside or inside of the switch and application
system, adversely affect the switch in the following ways:
• A conduction pattern of capacitance coupling.
• Inductance coupling.
• Electromagnetic wave radiation.
• Common impedance (including the grounding system) coupling.
3
To prevent EMI, perform the following tasks:
• If AC power is used, use a single-phase three-wire power receptacle with protection earth (PE) to
filter interference from the power grid.
• Keep the switch far away from radio transmitting stations, radar stations, and high-frequency
devices.
• Use electromagnetic shielding, for example, shielded interface cables, when necessary.
Laser safety
W
ARNING!
Do not stare into any fiber port when the switch has power. The laser li
g
ht emitted from the optical fiber
might hurt your eyes.
The switch is a Class 1 laser device.
Installation tools
No installation tools are provided with the switch. Prepare the following tools yourself:
• Phillips screwdriver.
• ESD wrist strap.
• Marker.
4
Installing the switch
CAUTION:
Keep the tamper-proof seal on a mountin
g
screw on the chassis cover intact, and if you want to open the
chassis, contact H3C for permission. Otherwise, H3C shall not be liable for any consequence caused
thereby.
Figure 1 Hardware installation flow
Ground the switch
Install the switch
Start
Connect the power cords
Verify the installation
Switch on the circuit
breakers to power on the
switch
Operating correctly?
Switch off the circuit
breakers to power off the
switch
Resolve the problem
No
Yes
Install fan trays
Install power modules
Install interface cards?
No
Yes
Install interface cards
Operating correctly? Resolve the problem
Yes
No
End
5
Installing the switch in a 19-inch rack
IMPORTANT:
To close the rack door easily, make sure the rack depth is a minimum of 1000 mm (39.37 in).
Installation accessories
Table 3 Installation accessories
Switch
model
Mounting brackets
(provided)
Cable management
brackets
Rack mounting rail kit (provided)
S7502E-XS
1U high, one pair.
See Figure 2.
N/A
1U high, includ
ing one pair of chassis rails
and one pair of slide rails. See Figure 4.
S7504E-XS
2U high, one pair.
See Figure 3.
One pair (provided).
See Figure 3.
2U high, including one pair of chassis rails
and one pair of slide rails. See Figure 5.
Figure 2 Mounting brackets for the S7502E-XS switch
Figure 3 Mounting brackets for the S7504E-XS switch
(1) Cable management bracket (2) Mounting bracket
1 2
6
Figure 4 1U rack mounting rail kit
(1) Chassis rail (2) Slide rail
Figure 5 2U rack mounting rail kit
(1) Chassis rail (2) Slide rail
Rack-mounting procedures at a glance
Figure 6 Rack-mounting procedure
NOTE:
If a rack shelf is available, you can put the switch on the rack shelf, slide the switch to an appropriate
location, and attach the switch to the rack with the mounting brackets.
Follow these guidelines when you install the switch in a 19-inch rack:
• The distance between the front and rear posts of the rack must meet the requirements described
in Table 4.
• T
o secure the switch to the rack, you must install not only mounting brackets, but also chassis rails
and slide rails.
1 2
7
Table 4 Distance requirements between the front and rear rack posts
Switch model Installation method
Minimum distance
between the front and
rear rack posts
Maximum distance
between the front and
rear rack posts
S7502E-XS
Using provided
mounting brackets
and chassis rails
520 mm (20.47 in) 789 mm (31.06 in)
S7504E-XS
Using provided
mounting brackets
and chassis rails
518 mm (20.39 in) 888 mm (34.96 in)
Attaching the mounting brackets, chassis rails, and grounding
cable to the chassis
The switch has one mounting position near the network ports and one mounting position near the power
modules for mounting brackets.
The S7504E-XS switch provides three grounding points: primary grounding point (with a grounding sign),
auxiliary grounding point 1, and auxiliary grounding point 2. The S7502E-XS switch provides two
grounding points: primary grounding point (with a grounding sign) and auxiliary grounding point 1.
Figure 7 Mounting and grounding positions on the S7504E-XS switch
(1) Auxiliary grounding point 2 (2) Power module-side mounting position
(3) Network-port-side mountin
position
(4)
A
uxiliary
g
roundin
g
point 1
(5) Primary
g
roundin
g
point
8
Figure 8 Mounting and grounding positions on the S7502E-XS switch
(1) Power module-side mountin
position
(2) Primary
g
roundin
g
point
(3) Auxiliary grounding point 1 (4) Network-port-side mounting position
Attaching the mounting brackets and chassis rails to the chassis
1. Align the mounting brackets with the screw holes in the chassis. Use M4 screws (provided) to
attach the mounting brackets to the chassis.
{ To install the mounting brackets at the power module-side mounting position, see Figure 9
and Figure 10.
{ To install the mounting brackets at the network port-side mounting position, see Figure 11
and Figure 12.
2. Align the
chassis rails with the rail mounting holes in the chassis:
{ If the mounting brackets are in the power module-side mounting position, align the chassis rails
with the screw holes at the front of the side panels (see Figure 9 and Figure 10).
{ If the mounting brackets are in the network port-side mounting position, align the chassis rails
with the screw holes at the rear of the side panels (see Figure 11 and Figure 12).
3. Use M4 screws (provided) to attach the chassis rails to the chassis.
NOTE:
• Secure the mounting brackets and chassis rails to both sides of the chassis in the same way.
• To install the mounting brackets at the network port-side mounting position on the S7502E-XS and
S7504E-XS switches, use the four screw holes nearest to the network port side. To install the mountin
g
brackets at the power module-side mounting position on the S7502E-XS and S7504E-XS switches, use
the four screw holes nearest to the power module side.
9
Figure 9 Attaching the mounting brackets and chassis rails to the S7502E-XS switch (power
module-side mounting position for the mounting brackets)
Figure 10 Attaching the mounting brackets and chassis rails to the S7504E-XS switch (power
module-side mounting position for the mounting brackets)
Figure 11 Attaching the mounting brackets and chassis rails to the S7502E-XS switch (network
port-side mounting position for the mounting brackets)
10
Figure 12 Attaching the mounting brackets and chassis rails to the S7504E-XS switch (network
port-side mounting position for the mounting brackets)
Connecting the grounding cable to the chassis
CAUTION:
Select grounding points as required. The primary grounding point and auxiliary grounding point 1 are
located on the left side panel. If you use one of these grounding points, you must connect the
g
roundin
g
cable to the grounding point before you mount the switch in the rack.
H3C recommends that you use the primary grounding point or auxiliary grounding point 1 because the
grounding cable and grounding screw that come with the switch are suitable only for these two
grounding points.
To use auxiliary grounding point 2, prepare a grounding cable yourself.
This section uses the primary grounding point on the S7502E-XS switch as an example.
To connect the grounding cable to a grounding point:
1. Choose a grounding point.
2. Unpack the grounding cable and grounding screws.
You can use the cable and screws shipped with the switch only for connecting to the primary
grounding point or auxiliary grounding point 1.
3. Align the two-hole grounding lug at one end of the cable with the grounding holes of the
grounding point, insert the grounding screws into the holes, and tighten the screws with a
screwdriver, as shown in Figure 13.
11
Figure 13 Attaching the grounding cable to the primary grounding point on the S7502E-XS switch
Attaching the slide rails to the rack
The procedures are the same for attaching 1U and 2U slide rails to the rack. This section uses the 1U
slide rails as an example.
To attach the slide rails to the rack:
1. Identify the rack attachment position for the slide rails.
2. Install cage nuts (user-supplied) in the mounting holes in the rack posts.
3. Align the screw holes in one slide rail with the cage nuts in the rack post on one side, and use
screws (user-supplied) to attach the slide rail to the rack, as shown in Figure 14.
4. Repeat the pr
eceding steps to attach the other slide rail to the rack post on the other side.
Keep the two slide rails at the same height so the slide rails can attach into the chassis rails.
Figure 14 Installing the 1U slide rails
12
Mounting the switch in the rack
This task requires two people.
To mount the switch in the rack:
1. Wear an ESD wrist strap and make sure it makes good skin contact and is reliably grounded.
2. Verify that the mounting brackets and chassis rails have been securely attached to the switch
chassis.
3. Verify that the slide rails have been correctly attached to the rear rack posts.
4. Install cage nuts (user-supplied) to the front rack posts and make sure they are at the same level as
the slide rails.
5. One person performs the following operations:
a. Supporting the bottom of the switch, aligns the chassis rails with the slide rails on the rack
posts.
b. Pushes the switch slowly to slide the chassis rails along the slide rails until the mounting
brackets are flush with the rack posts.
6. Another person uses screws (user-supplied) to attach the mounting brackets to the rack.
To secure the switch in the rack, make sure the front ends of the slide rails reach out of the chassis
rails.
Figure 15 Mounting the S7502E-XS switch in the rack (power module-side mounting position for the
mounting brackets)
13
Figure 16 Mounting the S7502E-XS switch in the rack (network port-side mounting position for the
mounting brackets)
Figure 17 Mounting the S7504E-XS switch in the rack (power module-side mounting position for the
mounting brackets)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64