Construction Metals CMIHB34 Operating instructions

Type
Operating instructions
ADJUSTABLE PIPE FLASHING #CMIHB34
INSTALLATION GUIDELINES
These basic installation guidelines are for use with typical or standard applications. It is always recommended to seek advice from a licensed
professional, and to check with your local building inspector or building permit office for approvals and possible variations that may apply.
CAUTION!
Working above grade is inherently dangerous, be sure that proper fall protection measures are in place.
When working with power tools and sheet metal, gloves and eye protection are absolutely required.
Hard Plastic Base with Adjustable Elastomer Collar • 3 inch & 4 inch
Do not use petroleum based mastics, sealing compounds or paint on elastomer collar or hard plastic base
Using the pull tabs, adjust the size of the opening to fit
the pipe.
1. After shingling up to the pipe, slide flashing down over pipe.
3. Secure flange with 6 roofing nails. 4. Continue shingling above the vent pipe to complete the
installation. The tight neoprene seal means there's no need for
any sealant at the base of the pipe.
3-4 ADJUSTABLE FLASHING
Leave all tabs intact for 3 in. pipes
Remove Pull Tab for 4" pipes
FLANGE
HARD BASE
PULL TAB
ELASTOMER
COLLAR
(A)
HB34 Flange: 12" x 15.5"
3
2
1
  • Page 1 1