ABSCO ZA30292HK User guide

Type
User guide
CONCRETE SLAB
PAGE 1
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed
Assembly Instructions
Model: 30292H
10mm
50mm
WHEN LAYING YOUR CONCRETE
SLAB, CHAMFER THE 50mm EDGES
DOWNWARDS BY 10mm.
50mm
THIS WILL ENSURE THAT
CLEAR FROM YOUR SHED
WATER RUN OFF IS KEPT
FRONT: 3.00m
SIDE: 2.92m
WALL HEIGHT: 2.035m
GABLE HEIGHT: 2.300m
We thank you for choosing an Australian Made Shed. For further assistance please
visit our detailed instructional video library at http://www.absco.com.au/videos.php
At ABSCO Industries we are always looking to be number ONE, so please let us
know what you think of our instructions. Feedback makes us better.
3100mm
3020mm
FOR CONSTRUCTION IN
NON-CYCLONIC AREAS
WIND RATING: W33N (N2)
SITE PREPARATION
GENERAL INSTRUCTIONS
A NOTE ON SAFETY
The site for the shed must be level.
It is recommended that the shed be set on a concrete slab and anchored
down appropriately (refer page 15 for details).
Anchor sets are not supplied as standard items with this product.
Before commencing any assembly, read through these instructions in
detail to gain a thorough understanding of assembly methods and
associated details.
Unpack the carton and carefully identify and check off all the parts
against the parts described and illustrated on pages three to five.
Some parts may have sharp edges. It is advisable to wear gloves when
handling these items and safety glasses if drilling holes. Sensible shoes
are highly recommended.
Do not erect your shed in windy conditions, ensure that the shed is
securely anchored to a solid foundation immediately after construction is
completed.
It is highly recommended to erect the shed with two or more people.
TOOLS REQUIRED
PAGE 2
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
3mm
4mm
OPTIONAL
Absco Highlander Shed - Model: 30292H
PAGE 3
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
COMPONENT
DESCRIPTION
PART
No.
CHECK
COMPONENT
DESCRIPTION
PART
No.
CHECK
QTY QTY
2
6
2
2
2
4
1
1
4
2
4
1
1
1
2
2
1
2
2
2
STEEL SHEET
2034mm X 773mm
H31
STEEL SHEET
1546mm X 773mm
44L
STEEL SHEET
1546mm X 773mm
45A
STEEL SHEET
2034mm X 711mm
H34
STEEL SHEET
2034mm X 731mm
HRC
GABLE L/H
L=1475mm
16L
GABLE R/H
L=1475mm
16R
13A
BRACE
L: 393mm
77A
CHANNEL
L = 2993mm
55C
CHANNEL
L = 2993mm
77B
CHANNEL
L = 2993mm
81B
CHANNEL
L = 2993mm
81A
CHANNEL
L = 2993mm
59A
CHANNEL
L = 2919mm
81G
CHANNEL
L = 2919mm
78A
CHANNEL
L = 1568mm
COMPONENTS PACKING LIST - CHECK OFF ALL COMPONENTS
STEEL SHEET
1546mm X 773mm
44R
STEEL SHEET
2034mm X 773mm
H30
STEEL SHEET
1974mm X 773mm
F
STEEL SHEET
1974mm X 773mm
E
PAGE 4
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
1
12A
2
DOOR
STRAP
L: 165mm
14A
2
CAP GABLE
L: 170mm
12
4mm CSK SCREW &
NUT SECURE HINGES
TO DOOR
8
4mm NUT & BOLT SET
SECURE TWO
PADBOLTS TO DOOR
SHEET
220
SELF TAPPING
SCREWS
3
DOOR
PADBOLT
2
DOOR
PADBOLT
HASP
18
3mm POP RIVETS SECURE
HINGES TO DOOR
(ALTERNATIVE FIXING
METHOD)
1
ASSEMBLY
INSTRUCTIONS
COMPONENT
DESCRIPTION
PART
No.
CHECK
COMPONENT
DESCRIPTION
PART
No.
CHECK
QTY QTY
CONTENTS OF FITTINGS PACKET
COMPONENTS PACKING LIST - (CONT.) CHECK OFF ALL COMPONENTS
22A
4
4
1
21
2
1
4
1
79A
CHANNEL
L = 1568mm
HC1
CHANNEL WITH HINGES
L = 1974mm
HC2
CHANNEL
L = 1974mm
58C
CHANNEL
L = 773mm
97A
RIDGE
BEAM
L = 2993mm
HJ1
JAMB L= 2034mm
90A
JAMB L= 1568mm
91A
JAMB L= 1120mm
HJ3
JAMB L= 1974mm
87B
LIP TRIM L= 1546mm
Absco Highlander Shed - Model: 30292H
VIEW OF ROOF COMPONENTS
PAGE 5
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
VIEW OF WALL COMPONENTS
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander
Shed - Model: 30292H
PAGE 6
HRC
H31
H31
HRC
H34
E
F
H34
HRC
H31
13A
H31
HRC
H30
H31
13A
H31
H30
81G
59A
77B
16R
16L
59A
16R
77A
91A
55C
79A
91A
HJ1
HJ1
90A
16L
81B
81G
22A
PAGE 7
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
ABSCO ASSEMBLY INTRODUCTION
FASTENING SYMBOLS
The snap-tite assembly system locks all perimeter channels to all roof and wall
sheets without the need for tools and fasteners .
To pre-assemble the four wall panels
and two roof panels, the perimeter
channels are secured to the top and
bottom of each panel using the
snaptite system, as detailed on the
following pages wherever you see
the symbol.
Position sheets on timbers,
trestles or partly over edge of
concrete slab.
Each perimeter channel must finish flush
with the edges of the sheets. the snap-tite
system allows adjustment for this
process by simply tapping the channel
along the sheets until each end is neatly
flush.
Join components together with one screw at this
location only, as some channel sections have extra
holes that are not required for this model of garden
shed
Do not join components together at this location yet,
as the screw may obstruct further assembly of other
components
4mm NUT & BOLT SET
3mm POP RIVETS
PUSH
PUSH
HIGH SIDE
HIGH SIDE
PUSH
HIGH SIDE
HIGH SIDE
After joining sheets together,
position channel over one end of the
sheets, gently tapping it over the
snaptite lugs, working along the
sheets to the other end.
HIGH SIDE
SNAP
T TE
i
PAGE 8
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
DOOR PANEL ASSEMBLY
20mm FLANGE
58C
58C
FOUR HOLE SET
FOR PADBOLT
CONNECTION
58C
12A
HC1
HC1
15mm FLANGE
E
F
E
F
58C
HC2
HJ3
REAR PANEL ASSEMBLY
SIDE PANEL ASSEMBLY
(2 Required)
PAGE 9
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
H30
H31
H31
H30
77B
81B
Absco Highlander Shed - Model: 30292H
59A
81G
SMALL PAN
H31
H31
SMALL PAN
2 x PRE-PUNCHED
HOLES TO THIS
END OF EACH
SHEET WITH PART
NO. 81A FITTED
ROOF PANEL ASSEMBLY
(2 Required)
PAGE 10
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
44L
45A
45A
44R
87B
81A
78A
87B
FRONT PANEL ASSEMBLY
PAGE 11
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
HJ1
HJ1
77A
90A
79A
55C
H34
H34
DOOR PANEL ASSEMBLY
NOTE: The two holes required to connect the padbolt hasp for each door have not been pre-punched, to allow for
proper alignment. position each hasp centrally over the padbolt shaft, and drill 3mm holes and secure with screws
NOTE: Nuts and bolts (supplied) may be used instead of
pop rivets (supplied) by simply enlarging the hinge hole
sets in the jamb using a 4mm drill bit
PAGE 12
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
91A
91A
E
F
Absco Highlander Shed - Model: 30292H
PANEL CONSTRUCTION
NOTE: Take care to ensure that both front
and rear wall panels are not positioned
upside down. the top channel of each
panel is pre-punched for attaching roof
sheets, the bottom channels are not.
SIDE WALL PANEL CHANNELS
FIT INTO THE NOTCHED
FRONT AND REAR WALL
PANEL CHANNELS
CHANNEL TYPE 78A
THIS END
CHANNEL TYPE
81A THIS END
PAGE 13
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
97A
Absco Highlander Shed - Model: 30292H
ROOF CONSTRUCTION
PAGE 14
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
Absco Highlander Shed - Model: 30292H
37mm
SECURE RIDGE BEAM TO
GABLE SECTIONS WITH
TWO SCREWS AT EACH
END. SECURE EACH ROOF
PANEL WITH ONE SCREW
IN EACH CORNER ONLY
AT THIS STAGE
ROOR OVERHANGS
ALL WALL PANELS
BY 37mm
OUTSIDE VIEW
INSIDE VIEW
INSIDE VIEW
AFTER THE ROOF PANELS
HAVE BEEN SECURED, FIT
TWO GABLE BRACES (13A)
FROM THE TOP WALL
CHANNEL TO THE UNDERSIDE
OF THE RIDGE BEAM AT 45
DEGREES AS SHOWN TO
BOTH GABLE WALLS.
2 X GABLE
BRACE
(13A)
FINAL CONSTRUCTION
BEND THE TOP AND
BOTTOM FLANGES AS
SHOWN, THEN HOOK THE
BOTTOM FLANGES UNDER
THE TOP CHANNEL AND
SCREW THE TOP FLANGES
FOR BOTH AS SHOWN
GABLE CAPS
PAGE 15
ABSCO INDUSTRIES ASSEMBLY INSTRUCTION - MODEL: 30292H 26/11/10
14A
- EACH ANCHOR CONSISTS OF ONE NUT, BOLT,
DYNABOLT AND STEEL ANGLE
- DRILL A 10mm HOLE INTO
THE WALL SHEET
- DRILL A 10mm HOLE INTO THE
CONCRETE
ANCHORING OF SHED
Absco Highlander Shed - Model: 30292H
LOCATION OF 12
CONCRETE ANCHORS
STEEL
ANGLE
WALL
SHEET
BOLT & NUT
SLAB
DYNABOLT
PRODUCT WARRANTY
Congratulations on your purchase of an ABSCO Product.
ABSCO SHEDS are made using high quality Bluescope™ Australian made Zincalume™ or
Colorbond Steel™.
We are pleased to advise we warrant that this steel will not rust, crack, flake peel or blister for
20 years from date of purchase.
This warranty does not apply to surface deterioration of panels caused by ‘Swarf” (Tiny particles
of steel debris left from cutting, grinding or drilling operations) that has not been removed after
building construction, or as a result of contact with damp soil, chemicals, fertilisers or other
corrosive substances.
This warranty covers any shed used for normal domestic use and installed in accordance with
the installation instructions. The warranty does NOT cover Damage caused by storms, wind, rain
snow or poor foundations.
This warranty does NOT cover ABSCO products installed in severe coastal, industrial or other
highly corrosive environments. The warranty does not cover fasteners (screws, nuts, bolts,
rivets, hasps or bolts).
The warranty is limited to replacement and delivery of components and does not include any
labour or installation costs.
The warranty applies to the exclusion of all other representations, guarantees or warranties
express or implied, our goods come with guarantees that cannot be excluded under the
Australian consumer law and is not transferable
For further information go to http://www.consumerlaw.gov.au.
Please retain a proof of purchase (sales docket or invoice) or register your warranty within 30
days of purchase here: www.absco.com.au/register_warranty.php
In the unlikely event a warranty claim is made it must be supported by photographic evidence
together with proof of purchase documentation (or on-line registration of purchase) and
forwarded to ABSCO INDUSTRIES, PO BOX 119 ACACIA RIDGE QLD AUSTRALIA 4110
Issued January 2011
ABSCO STEEL BUILDINGS- STORAGE GUIDELINES
ABSCO steel buildings include garden sheds, storage units, aviaries, garages and carports.
ABSCO steel buildings are designed to be weatherproof for normal weather conditions. In the
event of extreme weather conditions such as heavy rain, combined with high wind gusts, the
ridge capping, sheeting joins, screw fixings etc., may exhibit minor deformations which may
allow some water entry. These areas should be checked regularly to ensure that maximum
strength and protection is maintained.
Other weather conditions such as extreme heat and extreme cold, moist or dry air can influence
the effects of concrete floor moisture and/or condensation on the underside of the roof sheets.
ABSCO SHEDS and storage units are primarily used for storage of garden equipment such as
lawnmowers, wheelbarrows, garden tools etc. Storage items that might be adversely affected
by any of the above conditions may require additional protection such as being sealed or
covered by plastic sheets and/or stacked above the concrete floor on timber slats.
Waterproof sealants may be used to offer further protection where required around joins and
screw fixings, as can rubber door seals and other products which are available from most
hardware outlets.
Placement of waterproof sealants (silicone) between the base of the shed and concrete slab is
not recommended, as this process can have a reverse effect, preventing excess water from
escaping, resulting with water accumulating and being trapped inside the shed.
Absco accepts no responsibility for water entry, floor moisture, condensation or the condition
of the Contents inside your Absco steel building arising from any of the pre-mentioned weather
conditions.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17

ABSCO ZA30292HK User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI