17
12
13*
14*
15*
16*
10*
11*
4
7
8
1
3
2
5
6
20
21
22
23
24
25
27
28
31
29
30
* D e pe nding on th e m ode l
* Nur be stim m te Mode lle
* Suivant le s m odèle s
* Solo pe r alcuni m ode lli
IMPO RTANT SAFEGUARD S
• Re ad th is ins truction book le t care fully.
• Be fore us ing th e appliance , ch e ck th at th e m ains pow e r
voltage corre s ponds to th e voltage s h ow n on th e rating
plate .
• D o not sw itch th e appliance on if it appe ars to be faulty
in any w ay or it h as a dam age d cord or plug. D o not try
to re pair th e appliance by yourse lf. For re pairs and
acce s s orie s w e are at your se rvice from Monday to
Friday from 8am to 6pm
• Alw ays re m ove th e plug from th e pow e r s ock e t w h e n
th e appliance is not in us e and be fore carrying out any
cle aning or m ainte nance ope rations.
• Ne ve r le ave th e appliance unatte nde d w h e n it is
sw itch e d on. Ke e p th e appliance out of re ach of
ch ildre n.
• Th is appliance is for dom e s tic us e only. Use as
de scribe d in th is ins truction book le t.
• D o not pull th e appliance by th e cord. D o not unplug by
pulling on th e cord. D o not use th e cle ane r w ith a
dam age d cable . If th e cable dam age d, it sh ould be
re place d at a se rvice ce nte r. Th is is not cove re d by th e
w arranty.
• D o not us e appliance on w e t s urface s or to vacuum
liq uids , m ud, ash and burning cigare tte butts . D o not
vacuum up any h igh ly flam m able or e xplosive
subs tance s or gas e s .
Th e se m ate rials can cause se rious dam age to th e
m otor - a dam age w h ich is not cove re d by th e
w arranty.
• D o not unplug th e vacuum cle ane r w ith w e t h ands .
• D o not ope rate th e vacuum cle ane r too clos e to h e ate rs
and radiators , stove s e tc.
• Be fore you start us ing th e vacuum cle ane r, ple ase
re m ove large or sh arp obje cts from th e floor to pre ve nt
dam age to th e dus t containe r and h ose .
INSTRUCTIO NS FO R USE
• Be fore placing into ope ration m ak e ce rtain th at th e
filte rs are in th e prope r position.
20 To conne ct th e h ose into th e suction inle t pus h it until it
click s .
20 To disconne ct th e h os e from th e s uction inle t pus h th e
button at th e e nd of th e h ose .
• Unw ind a sufficie nt le ngth of cab le and ins e rt th e plug
into th e pow e r sock e t. A YELLO W m ark on th e pow e r
cable sh ow s th e ide al cable le ngth . D o not e xte nd th e
cable be yond th e RED m ark .
• Pre s s th e O N/O FF button to sw itch th e appliance on.
O n initial s tart up full pow e r is re ach e d afte r
approxim ate ly 1-2 se conds.
• To re w ind th e pow e r cable , pre ss th e re w ind button w ith
foot, and guide th e cab le w ith h and to e nsure th at it
doe s not w h ip caus ing dam age .
• By m oving th e variable pow e r control, th e s uction
pow e r can be adjus te d.
MAINTENANCE
REMO VING TH E CO NTENTS O F TH E D UST CO NTAINER
Ne ve r ope rate th e cle ane r w ith out th e dust containe r
installe d.
Th e dust containe r m us t be e m ptie d if th e w indow of th e
dus t containe r indicator ch ange s into re d w h e n th e
cle ane r is ope rating at m axim um pow e r and th e nozzle
is rais e d from th e floor.
32 If th e dus tbin indicator is activate d th an firstly ch e ck th e
air inle t ch anne l of th e appliance . If it is clogge d by big
pie ce s of pape r, dus t, h air or oth e r m ate rials th e n cle an
it. If afte r cle aning th e dus tbin indicator s taye s
activate d ch e ck th e H EPA.
21 Re m ove th e dust containe r from th e cle ane r.
22 Re m ove th e filte r s e t from th e dust containe r by tak ing it
in th e w ay indicate d in th e icon.
23 Re m ove th e conte nts of th e dust containe r.
22 Put th e filte r s e t back into th e dus t containe r.
21 Put th e dust containe r back into th e cle ane r.
CLEANING TH E FILTERS
• Filte rs sh ould be re place d at le ast tw ice a ye ar or w h e n
th e y be com e vis ib ly soile d.
• D is conne ct from e le ctrical outle t be fore ch anging th e
filte rs .
Cle aning th e cartridge filte r
Alw ays ope rate th e cle ane r w ith th e cartridge filte r
installe d.
21 Re m ove th e dust containe r from th e cle ane r.
22 Re m ove th e filte r s e t from th e dust containe r by tak ing it
as indicate d in th e icon.
24 Re m ove th e cartridge filte r by turning it counte r -
clock w is e (A) and pull it out (B) as indicate d in th e icon.
25 Re m ove th e prote ctor m e s h from th e cartridge filte r.
26,27 Sh ak e th e dirt from th e filte r and th e m e s h into a bin,
if ne ce s s ary th e filte r and m e s h can be rinse d, w ith cold
w ate r, unde r a tap.
D ESCRIPTIO N O F PARTS
1. Suction inle t
2. D us t containe r indicator
3. Variable pow e r control
4. Cable re w ind button
5. O n/off sw itch
6. W h e e l
7. D us t containe r
8. Carrying h andle
9 . H ose
10. Te le s copic tube *
11. Me tal tube s *
12. D ual purpose floor
nozzle
13. Com bination cre vice
nozzle / brush *
14. U ph ols te ry nozzle *
15. H ard floor nozzle *
16. Turb o nozzle *
17. Cartridge filte r
18. Prote ctor m e s h
19 . Park ing position
* D e pe nding on th e m ode l
1
English
19
9
A
B
26
18
32