Convotherm Designer's Handbook 4 Owner's manual

Type
Owner's manual
Combi steamer
Convotherm 4
Designer's Handbook CE - Original, ENG
Your meal. Our mission.
The Convotherm 4 Designer Handbook
This Designer handbook is a reference source. Based on our document portfolio, it draws together all the
technical information relevant to you in a single manual.
"Convotherm 4 – Designed around you" means that we offer the widest range of combi steamers on the mar‐
ket.
Our combi steamers come in seven sizes each offering two types of controls, with a choice of boiler or steam
injection and of course electric or gas appliance. You can also customize these 52 standard models with va‐
rious options such as our patented disappearing door.
The technical documentation to accompany such a wide product range is equally comprehensive. We there‐
fore decided to make it as easy as possible for you to find the technical information you need by providing
our Designer handbook. Here you will find the following clearly-presented information:
technical data
consumption figures (e.g. cleaning agent consumption)
emissions data (e.g. dissipated heat)
guidance on setting up and installing the appliance
a summary of certification and declarations of conformity, and much more.
You can also download the Designer handbook from our open Download Center,
which you can enter from our homepage www.convotherm.com. In the Download Center, simply click on
"Manuals" to find the document you require. Of course you can also find here the DWG, DXF and BIM files
for our products and all other documents needed for your design.
Table of Contents
1 General information 8
2 An overview of Convotherm 4 9
2.1 A summary of the appliances 9
2.2 Convotherm easyTouch range 10
2.3 Convotherm easyDial range 11
3 Technical data for the combi steamers 12
3.1 Electric appliances 12
3.1.1 Dimensions 12
3.1.2 Weights 12
3.1.3 Electrical supply 14
3.2 Gas appliances 18
3.2.1 Dimensions 18
3.2.2 Weights 18
3.2.3 Heat output 20
3.2.4 Electrical supply 21
3.3 Water figures 25
3.3.1 Water supply 25
3.3.2 Water quality 25
3.4 Emissions 27
3.4.1 Dissipated heat 27
3.4.2 Sound levels 27
3.4.3 Exhaust gas values 28
3.4.4 Exhaust gas output rate 28
3.5 Loading weights and capacities 29
3.5.1 Maximum loads 29
3.5.2 Container capacities 29
3.5.3 Plate banquet capacities 29
3.5.4 Capacities for banquet system 30
3.5.5 Capacities according to food type 30
4 Consumption figures 31
4.1 Gas consumption 31
4.2 Water consumption 31
4.3 Cleaning agent consumption for fully automatic oven cleaning 33
4.3.1 Canister dispensing 33
4.3.2 Single-measure dispensing 36
5 Setting up the appliance 39
5.1 Requirements for the installation location 39
5.1.1 Minimum dimensions for conveying the appliance 39
5.1.2 Setting up table-top units 39
5.1.3 Setting up floor-standing units 40
5.1.4 Area around the appliance 40
5.1.5 Supporting surface 41
5.2 Space required 41
5.2.1 Safety clearances 41
5.2.2 Space required for right-hinged door 42
5.2.3 Space required for disappearing door 43
5.2.4 Minimum vertical clearance 44
5.3 Accessories 45
Table of Contents
Designer's Handbook 5
5.3.1 Appliance stands 45
5.3.2 Heat shield 47
6 Installations 48
6.1 Electrical installation 48
6.1.1 Installation regulations and customer-installed components 48
6.1.2 Mains supply connection 48
6.1.3 Residual-current device 49
6.1.4 Energy optimization system 49
6.2 Gas installation 50
6.2.1 Gas connection 50
6.2.2 Exhaust gas extraction system 51
6.3 Water connection 52
6.3.1 Installation regulations and customer-installed components 52
6.3.2 Connection diagram without water treatment 53
6.3.3 Connection diagram with water treatment 54
6.3.4 Accessories 55
6.3.5 Using Filter Care to monitor the water treatment system 57
6.4 Wastewater connection 58
6.4.1 Installation regulations and customer-installed components 58
6.4.2 Drain connection for table-top units 58
6.4.3 Drain connection for floor-standing units 59
6.4.4 Wastewater temperature 59
6.4.5 Accessories 59
6.5 Installing the fully automatic oven cleaning system 60
6.5.1 Cleaning methods 60
6.5.2 Cleaning using canister dispensing 61
6.5.3 Cleaning using single-measure dispensing 62
6.5.4 Cleaning agent 63
6.5.5 Accessories 64
7 Appliance options and accessories 66
7.1 Convotherm 4 stacking kits 66
7.1.1 Using stacking kits for Convotherm 4 66
7.1.2 Combinations 67
7.1.3 Weights 68
7.2 ConvoVent and ConvoVent+ condensation hoods for the Convotherm 4 69
7.2.1 Using condensation hoods 69
7.2.2 ConvoVent 4 70
7.2.3 ConvoVent 4+ 70
7.2.4 Technical Data 71
7.2.5 Accessories 72
7.3 Convotherm 4 built-in vapour condenser (optional) 73
7.4 Convotherm 4 software solutions 74
7.4.1 ConvoLink 74
7.4.2 Networking 75
7.5 ConvoSmoke - smoker model 76
7.6 ConvoGrill - grill model 77
7.7 Convotherm 4 Prison model 78
7.8 Convotherm 4 Marine model 79
8 Certification and EC Declaration of Conformity 80
8.1 Certification 80
8.2 Declaration of Conformity 83
8.2.1 EC Declaration of Conformity for electric appliances 83
Table of Contents
Designer's Handbook 6
8.2.2 EC Declaration of Conformity for gas appliances 84
Table of Contents
Designer's Handbook 7
1  General information
Purpose
This Designer handbook is intended to provide a summary of the Convotherm 4 combi steamers, their
accessories and appliance options. It is intended as a clear reference source for kitchen design purpo‐
ses and as a helpful reference for everyday use.
It is not an Installation manual, Operating manual or Repair manual. It is intended solely for design
and planning and must never be used as a substitute for these more specific manuals, which contain
far more detailed information.
Please refer to the Installation manual for further technical data and guidance on installation, positio‐
ning and setup.
Safety information relating to the combi steamer appears only in the Installation manual and the User
manual.
Who should read this manual
This manual is intended for kitchen designers.
Notation for decimal points
A decimal point is always used in order to achieve international standardization.
1 General information
Designer's Handbook 8
2  An overview of Convotherm 4
2.1  A summary of the appliances
A comparison of the controls
The Convotherm 4 combi steamers come in two essential designs, each in seven different sizes, with
a total of 56 different models to choose from.
Design Convotherm 4 easyTouch Convotherm 4 easyDial
Number of dishes/day from 40 to 500 from 40 to 500
Dimension/GN 6+1 x 1/1 to 20 x 2/1 6+1 x 1/1 to 20 x 2/1
Table-top appliances models 6.10, 6.20, 10.10, 10.20 6.10, 6.20, 10.10, 10.20
Floor-standing appliance models 12.20, 20.10, 20.20 12.20, 20.10, 20.20
Model Boiler / injection system Boiler / injection system
Controls easyTouch easyDial
Energy Electric/Gas Electric/Gas
Standard features (selection)
ACS+ (Advanced Closed System+) x x
Crisp&Tasty (5 levels of moisture removal) x x
BakePro (5 levels for traditional baking) x x
HumidityPro (5 levels of humidification) x x
Fan speed (5 levels) x x
Cleaning system ConvoClean+ ConvoClean (optional)
Semi-automatic oven cleaning x x
Ethernet/LAN interface x o
HygienicCare Concept x x
User interface Full 9" touchscreen Digital display with C-Dial
Press&Go x -
TrayTimer load management x -
Regenerate Regenerate+ Regenerating function
Low-temperature cooking/Delta-T cooking x -
ecoCooking (energy-save function) x -
Cook&Hold x -
Max. no of cooking profiles/profile steps 399/20 99/9
On-screen help with video function x -
Multi-point core temperature probe x x
TriColor indicator ring x x
x = standard / - = not available / o = optional
2 An overview of Convotherm 4
Designer's Handbook 9
2.2  Convotherm easyTouch range
Overview of the easyTouch range
easyTouch controls TriColor indicator ring
Convotherm 4 easy‐
Touch features a full 9"
touchscreen for the la‐
test in convenient touch
control including a con‐
figurable user interface.
The TriColor indicator ring
displays the live operating
status and is ideal for at-a-
glance indication even
from distance.
Yellow stands for “in pre‐
paration”, red for “in pro‐
gress” and green for “rea‐
dy”.
Standard features (selection): Options:
ACS+ (Advanced Closed System+)
Crisp&Tasty (5 levels of moisture removal)
BakePro (5 levels for the traditional baking
function)
HumidityPro (5 levels of humidification)
Fan speed (5 levels)
Press&Go (automatic cooking)
ecoCooking (energy-save function)
Cook&Hold
On-screen help with video function
Right hinge
Regenerate+ (flexible function with prese‐
lect)
HygienicCare - antibacterial surfaces (con‐
trol panel, door handle, recoil shower head)
ConvoClean+ fully automatic oven cleaning
(eco / regular / express), with optional single-
measure dispensing
Semi-automatic oven cleaning
Preheat bridge integrated (floor-standing ap‐
pliances only)
USB port built into the control panel
Ethernet / LAN interface
Data storage for HACCP and pasteurization
figures
Disappearing door - more space as well as sa‐
fety at work
Sous-vide sensor, with external socket
Core temperature sensor, with external socket
Vapour condenser (built-in condensation hood)
available on request
ConvoSmoke food-smoking function (electrical
appliances only)
ConvoGrill grill model
Prison model
Marine version (electric appliances only)
2 An overview of Convotherm 4
Designer's Handbook 10
2.3  Convotherm easyDial range
Overview of the easyDial range
easyDial controls TriColor indicator ring
You can use the manu‐
al easyDial controls to
quickly configure your
own cooking profiles.
All the functions are
available in one level.
You can see everything
at a glance at all times -
even from a distance -
on the large brightly-lit
digital display with the
central Convotherm-Di‐
al (C-Dial) controls.
The TriColor indicator ring
displays the live operating
status and is ideal for at-a-
glance indication even
from distance.
Yellow stands for “in pre‐
paration”, red for “in pro‐
gress” and green for “rea‐
dy”.
Standard features (selection): Options:
ACS+ (Advanced Closed System+)
Crisp&Tasty (5 levels of moisture removal)
BakePro (5 levels for the traditional baking
function)
HumidityPro (5 levels of humidification)
Fan speed (5 levels)
Right hinge
Regenerating function: regenerate products
to their peak level
HygienicCare - antibacterial surfaces (con‐
trol panel, door handle, recoil shower head)
Semi-automatic oven cleaning
Preheat bridge integrated (floor-standing ap‐
pliances only)
USB port built into the control panel
Data storage for HACCP and pasteurization
figures
Disappearing door - more space as well as sa‐
fety at work
ConvoClean fully automatic oven cleaning (with
single-measure dispensing option)
Core temperature sensor, with external socket
Sous-vide sensor, with external socket
Ethernet / LAN interface
Vapour condenser (built-in condensation hood)
ConvoGrill grill model
Prison model
Marine version (electric appliances only)
2 An overview of Convotherm 4
Designer's Handbook 11
3  Technical data for the combi steamers
3.1  Electric appliances
3.1.1  Dimensions
Boiler/steam-injection appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Appliance including packaging
Width [mm] 1110 1345 1110 1345 1410 1165 1410
Height [mm] 1010 1010 1280 1280 1615 2150 2150
Depth [mm] 940 1140 940 1140 1170 970 1170
Appliance excluding packaging
Width for appliance with right-hinged
appliance door
[mm] 875 1120 875 1120 1135 890 1135
Width for appliances with disappea‐
ring door
[mm] 922 1167 922 1167 1182 937 1182
Height [mm] 786 786 1058 1058 1406 1942 1942
Depth with appliance door closed [mm] 792 992 792 992 1020 820 1020
Safety clearances
Rear [mm] 50 50 50 50 50 50 50
Right, for appliance with right-hinged
appliance door
[mm] 50 50 50 50 50 50 50
Right, for appliances with disappea‐
ring door
[mm] 50 50 50 50 50 50 50
Left
(larger gap recommended for servi‐
cing)
[mm] 50 50 50 50 50 50 50
Top (for ventilation) [mm] 500 500 500 500 500 500 500
3.1.2  Weights
Boiler appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Weight excluding packaging
excluding ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 115 170 135 184 250 265 349
- Disappearing door [kg] 123 178 145 194 265 285 369
including ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 121 176 141 190 256 272 356
- Disappearing door [kg] 129 160 151 200 271 292 376
including ConvoClean / ConvoClean+, including ConvoSmoker
- Right-hinged door [kg] 126 181 146 195 - - -
- Disappearing door [kg] 134 189 156 205 - - -
Weight of packaging
Weight of packaging [kg] 25 30 30 35 45 40 48
3 Technical data for the combi steamers
Designer's Handbook 12
Steam-injection appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Weight excluding packaging
excluding ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 105 158 123 169 235 250 331
- Disappearing door [kg] 113 166 133 179 250 270 351
including ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 111 164 129 175 241 257 340
- Disappearing door [kg] 125 172 139 185 256 277 359
including ConvoClean / ConvoClean+, including ConvoSmoker
- Right-hinged door [kg] 116 169 134 180 - - -
- Disappearing door [kg] 124 177 144 190 - - -
Weight of packaging
Weight of packaging [kg] 25 30 30 35 45 40 48
3 Technical data for the combi steamers
Designer's Handbook 13
3.1.3  Electrical supply
Boiler appliances (single-phase FC)
6.10 6.20 10.10 10.20 12.20 20.10 20.20
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption [kW] 11.0 19.5 19.5 33.7 33.7 38.9 67.3
Convection power [kW] 10.6 19.1 19.1 33.3 33.3 38.1 66.5
Steam power [kW] 9.1 18.1 18.1 27.2 31.6 31.6 40.2
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 15.9 28.1 28.1 48.7 48.7 56.2 97.3
Fuse rating [A] 16 35 35 50 50 63 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5
m in length.
[mm
2
]
5G4 5G6
5G6 5G16 5G16 5G16 5G35
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3~ 230 V 50/60Hz (3/PE)
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.2 66.4
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.0
Steam power [kW] 9.0 18.0 18.0 27.0 31.3 31.3 39.9
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 27.4 48.5 48.5 84.0 84.0 96.0 166.9
Fuse rating [A] 35 50 50 100 100 100 200
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6 4G16 4G16 4G35 4G35 4G35 4G70
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3~ 200 V 50/60Hz (3/PE)
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.2 66.4
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.0
Steam power [kW] 9.0 18.0 18.0 27.0 31.3 31.3 39.9
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 31.5 55.8 55.8 96.6 96.6 110.4 191.9
Fuse rating [A] 35 63 63 100 100 125 200
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6 4G16 4G16 4G35 4G35 4G50 4G95
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3 Technical data for the combi steamers
Designer's Handbook 14
Steam-injection appliances (single-phase FC)
6.10 6.20 10.10 10.20 12.20 20.10 20.20
3N~ 400V 50/60Hz (3/N/PE)
Rated power consumption [kW] 11.0 19.5 19.5 33.7 33.7 38.9 67.3
Convection power [kW] 10.6 19.1 19.1 33.3 33.3 38.1 66.5
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 15.9 28.1 28.1 48.7 48.7 56.2 97.3
Fuse rating [A] 16 35 35 50 50 63 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
5G4 5G6 5G6 5G16 5G16 5G16 5G35
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3~ 230 V 50/60Hz (3/PE)
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.2 66.4
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.0
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 27.4 48.5 48.5 84.0 84.0 96.0 166.9
Fuse rating [A] 35 50 50 100 100 100 200
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6 4G16 4G16 4G35 4G35 4G35 4G70
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3~ 200 V 50/60Hz (3/PE)
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.2 66.4
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.0
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 31.5 55.8 55.8 96.6 96.6 110.4 191.9
Fuse rating [A] 35 63 63 100 100 125 200
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G6 4G16 4G16 4G35 4G35 4G50 4G95
Recommended residual-current de‐
vice
Type A A A A A A A
Optional residual-current device Type B/F B/F B/F B/F B/F B/F B/F
3 Technical data for the combi steamers
Designer's Handbook 15
Boiler appliances (three-phase FC)
6.10 6.20 10.10 10.20 12.20 20.10 20.20
3~ 400 V 50/60Hz
Rated power consumption [kW] 11.0 19.5 19.5 33.7 33.7 38.9 67.3
Convection power [kW] 10.6 19.1 19.1 33.3 33.3 38.1 66.5
Steam power [kW] 9.1 18.1 18.1 27.2 31.6 31.6 40.2
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 15.9 28.1 28.1 48.7 48.7 56.2 97.3
Fuse rating [A] 16 35 35 50 50 63 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
5G4 5G6 5G6 5G16 5G16 5G16 5G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3~ 440 V 60 Hz
Rated power consumption [kW] 9.2 16.3 16.3 28.2 28.2 32.6 56.3
Convection power [kW] 8.8 15.9 15.9 27.8 27.8 31.8 55.5
Steam power [kW] 7.6 15.1 15.1 22.7 26.3 26.3 33.6
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 12.1 21.4 21.4 37.0 37.0 42.8 73.9
Fuse rating [A] 16 25 25 50 50 50 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G4 4G6 4G6 4G16 4G16 4G16 4G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3~ 480 V 60 Hz
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.6 66.8
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.1
Steam power [kW] 9.0 18.0 18.0 27.0 31.3 31.3 39.9
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 13.1 23.3 23.3 40.3 40.3 46.5 80.5
Fuse rating [A] 16 25 25 50 50 50 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G4 4G6 4G6 4G16 4G16 4G16 4G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3 Technical data for the combi steamers
Designer's Handbook 16
Steam-injection appliances (three-phase FC)
6.10 6.20 10.10 10.20 12.20 20.10 20.20
3~ 400 V 50/60Hz
Rated power consumption [kW] 11.0 19.5 19.5 33.7 33.7 38.9 67.3
Convection power [kW] 10.6 19.1 19.1 33.3 33.3 38.1 66.5
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 15.9 28.1 28.1 48.7 48.7 56.2 97.3
Fuse rating [A] 16 35 35 50 50 63 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
5G4 5G6 5G6 5G16 5G16 5G16 5G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3~ 440 V 60 Hz
Rated power consumption [kW] 9.2 16.3 16.3 28.2 28.2 32.6 56.3
Convection power [kW] 8.8 15.9 15.9 27.8 27.8 31.8 55.5
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 12.1 21.4 21.4 37.0 37.0 42.8 73.9
Fuse rating [A] 16 25 25 50 50 50 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G4 4G6 4G6 4G16 4G16 4G16 4G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3~ 480 V 60 Hz
Rated power consumption [kW] 10.9 19.3 19.3 33.4 33.4 38.6 66.8
Convection power [kW] 10.5 18.9 18.9 33.0 33.0 37.8 66.1
Motor power [kW] 0.35 0.35 0.35 0.35 0.35 0.7 0.7
Rated current [A] 13.1 23.3 23.3 40.3 40.3 46.5 80.5
Fuse rating [A] 16 25 25 50 50 50 100
Recommended conductor cross-
section for wires laid uncovered in
air up to 5 m in length.
[mm
2
]
4G4 4G6 4G6 4G16 4G16 4G16 4G35
Recommended residual-current de‐
vice
Type B/F B/F B/F B/F B/F B/F B/F
3 Technical data for the combi steamers
Designer's Handbook 17
3.2  Gas appliances
3.2.1  Dimensions
Boiler/steam-injection appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Appliance including packaging
Width [mm] 1110 1345 1110 1345 1410 1165 1410
Height [mm] 1010 1010 1280 1280 1615 2150 2150
Depth [mm] 940 1140 940 1140 1170 970 1170
Appliance excluding packaging
Width for appliance with right-hinged
appliance door
[mm] 875 1120 875 1120 1135 890 1135
Width for appliances with disappea‐
ring door
[mm] 922 1167 922 1167 1182 937 1182
Height [mm] 786 786 1058 1058 1406 1942 1942
Depth with appliance door closed [mm] 792 992 792 992 1020 820 1020
Safety clearances
Rear [mm] 50 50 50 50 50 50 50
Right, for appliance with right-hinged
appliance door
[mm] 50 50 50 50 50 50 50
Right, for appliances with disappea‐
ring door
[mm] 50 50 50 50 50 50 50
Left
(larger gap recommended for servi‐
cing)
[mm] 50 50 50 50 50 50 50
Top (for ventilation) [mm] 1000 1000 1000 1000 1000 1000 1000
3.2.2  Weights
Boiler appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Weight excluding packaging
excluding ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 130 190 155 214 280 295 379
- Disappearing door [kg] 138 198 165 224 295 315 399
including ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 136 196 161 220 286 302 386
- Disappearing door [kg] 144 180 171 230 301 322 406
including ConvoClean / ConvoClean+, including ConvoSmoker
- Right-hinged door [kg] 141 201 166 225 - - -
- Disappearing door [kg] 149 209 176 235 - - -
Weight of packaging
Weight of packaging [kg] 25 30 30 35 45 40 48
3 Technical data for the combi steamers
Designer's Handbook 18
Steam-injection appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
Weight excluding packaging
excluding ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 113 168 133 184 250 265 346
- Disappearing door [kg] 121 176 143 194 265 285 366
including ConvoClean / ConvoClean+, excluding ConvoSmoker
- Right-hinged door [kg] 119 174 139 190 256 272 355
- Disappearing door [kg] 133 182 149 200 271 292 374
including ConvoClean / ConvoClean+, including ConvoSmoker
- Right-hinged door [kg] 124 179 144 195 - - -
- Disappearing door [kg] 132 187 154 205 - - -
Weight of packaging
Weight of packaging [kg] 25 30 30 35 45 40 48
3 Technical data for the combi steamers
Designer's Handbook 19
3.2.3  Heat output
Boiler/steam-injection appliances
6.10 6.20 10.10 10.20 12.20 20.10 20.20
G20: Natural gas 2H (E) (referred to heating value H
i
)
Convection burner [kW] 11 21 21 31 31 42 62
Boiler burner (for GB) [kW] 11 19 19 31 31 31 31
G25: Natural gas 2L (LL) (referred to heating value H
i
)
Convection burner [kW] 10.5 20 20 30 30 40 60
Boiler burner (for GB) [kW] 10.5 18 18 30 30 30 30
G30/G31: Propane 3P* (referred to heating value H
i
)
Convection burner [kW] 11.5 21 22 31 31 44 62
Boiler burner (for GB) [kW] 11.5 19 20 31 31 31 31
Natural gas (AUS/NZL)
Convection burner [MJ/h] 42 74 81 115 115 162 230
Boiler burner (for GB) [MJ/h] 41 74 71 122 122 122 122
Propane (AUS/NZL)
Convection burner [MJ/h] 42 74 81 115 115 162 230
Boiler burner (for GB) [MJ/h] 41 74 71 122 122 122 122
Natural gas 13A (JPN)
Convection burner [kW] 11 - 20 - 31 42 62
Boiler burner (for GB) [kW] 11 - 18 - 31 31 31
Propane (JPN)
Convection burner [kW] 11 - 21 - 31 42 62
Boiler burner (for GB) [kW] 11 - 19 - 31 31 31
3 Technical data for the combi steamers
Designer's Handbook 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87

Convotherm Designer's Handbook 4 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI