2
INNOVATIVE HEARTH PRODUCTS • OUTDOOR GAS FIREPLACES • GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
Printed in U.S.A. © 2019 Innovative Hearth Products
P/N 900989-00 Rev. NC 05/2019
Innovative Hearth Products (IHP) reserves the right to make changes at any time, without notice,
in design, materials, specifications, prices and also to discontinue colors, styles and products.
Consult your local distributor for fireplace code information.
1769 East Lawrence Street • Russellville, AL 35654
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact INNOVATIVE HEARTH PRODUCTS
at IHP.us.com.
REFERENCE INFORMATION
Burner Orifice Sizes
Elevation 0-4500 feet ( 0-1372 meters)
Model Nat.Gas
drill size (inches)
Propane
drill size (inches)
StarLiteLX36 / VRE3236 3.25mm (.128") #49 (.073")
StarLiteLX42 / VRE3242 3.25mm (.128") #49 (.073")
Table 3
BTU Input (BTU/Hr)
Model No. Input Rate (BTU/Hr)
Natural Gas
StarLiteLX36ZEN / VRE3236ZEN 30,000 to 45,000
StarLiteLX42ZEN / VRE3242ZEN 30,000 to 45,000
Propane Gas (LP)
StarLiteLX42ZEP / VRE3242ZEP 32,000 to 41,000
StarLiteLX42ZEP / VRE3242ZEP 32,000 to 41,000
Table 4
Manifold Gas Supply Pressure (all models)
Fuel # High
Natural Gas 3.5" WC (0.87 kPa)
Propane 10.0" WC (2.49 kPa)
Table 2
Inlet Gas Supply Pressure (all models)
Fuel # Minimum Maximum
Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa)
Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa)
Table 1
WARNING: Test all gas piping and connections,
internal and external to unit, for leaks after install-
ing or servicing. Correct leaks at once.
WARNING: Never use an open flame to check
for a leak. Apply noncorrosive leak detection fluid
to all joints. Bubbles forming show a leak. Correct
all leaks at once.
FINAL PREPARATION
1. Leak check gas control and any connections you’ve made before
operating appliance. Refer to Checking Gas Connections in owner’s
manual.